MAURY USCG vessel records
← All vessels

LIGHTNING

Built
1991
Last inspected
13 June 2017
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 13 June 2017
…with no type recorded22
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1992–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

359968
Flag
HONG KONG
Maury page id
psix-359968

Documentation record

Tonnage as PSIX records it8123 - Convention (Subpart B), Gross Ton
2436 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 78 inspections, each with its date, unit and type; 136 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 78

13 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6174925
29 July 2014 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4937393
20 May 2014 Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4862909
17 February 2014 Deficiency Check · Examination of Repairs
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4807497
16 September 2013 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4717770
9 November 2012 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4481803
12 October 2012 Damage Survey · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4462215
14 September 2011 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4144770
10 October 2010 Internal Structural Exam · Examination of Repairs
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3874159
23 August 2010 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3831402
28 May 2010 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3737019
24 September 2009 Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 3593599
24 July 2009 Administrative Inspection
Administrative · Activities Europe · Activity 3547144
25 March 2008 Type not recorded
No type recorded · Activities Europe · Activity 3170768
21 February 2008 Drydock Exam · Annual Inspection · Hull Examination
Physical examination · Activities Europe · Activity 3150914
23 March 2007 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 2893469
15 December 2005 Examination of Repairs · Deficiency Check · COI Inspection · MARPOL Annex I Examination · Internal Structural Exam · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2553354
7 April 2005 Annual Inspection
Physical examination · Activities Europe · Activity 2324356
7 April 2005 Type not recorded
No type recorded · Activities Europe · Activity 2328189
11 December 2004 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2257358
10 December 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2258450
29 October 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2230740
2 September 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2184548
29 July 2004 Re-Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2148814
7 January 2004 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1977716
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979906
5 May 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1787196
28 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1764622
23 January 2003 Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1734471
7 November 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1702304
28 February 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1489979
28 January 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1481004
19 November 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1477009
12 October 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1076410
27 September 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1074458
30 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467295
16 January 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437816
3 October 2000 Permit to Proceed · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464970
21 June 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822119
30 May 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1379097
8 May 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048526
6 May 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436205
27 May 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378400
4 September 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1119971
7 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1089132
5 May 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 642047
14 March 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 488180
3 February 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 441167
26 November 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 457004
23 August 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1249171
30 July 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1086767
1 July 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1108202
13 June 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1189917
29 May 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1086283
5 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 70681
14 November 1995 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1425653
21 September 1995 Deficiency Check · Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1358914
10 September 1995 Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1190005
21 July 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1190049
13 June 1995 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1187292
5 April 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 842380
28 March 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 40933
30 January 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 828621
29 December 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 854695
7 December 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 118708
4 December 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1181931
20 October 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1181324
18 October 1994 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 869649
18 October 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1394257
17 October 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 43972
12 August 1994 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1174695
12 August 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469106
6 June 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415970
26 January 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1138025
2 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 40550
25 August 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1252418
12 June 1992 Inclining Experiment · Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1264909
5 May 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 941035

Deficiency record · 136

Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 July 2014 Resolved
The LP CO2 system was previously unapproved. Approval for the system was received on 26 January 2015 by the MSC. The approval letter requires local OCMI verification of 03 items including review of the U-1A form for the tank, installation of two PRVs, and inspection of non-galvanized piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2015
Resolved 24 March 2015
Resolution: Documentation and pictures were provided to verify the U-1A form and the installation of two PRVs. Inspection of galvanized piping will be completed at the vessels next annual inspection and it has been added as a special note.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 14 June 2014 Resolved
Fire detection system in main cargo hold is currently non-operational. Prove proper operation of fire detection system to the satisfaction of USCG Marine Inspector
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2014
Resolved 30 July 2014
Resolution: Fire alarm system has been repaired, serviced, and tested. Received technician''s report attesting to system being 100% operational.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 June 2014 Resolved
Low Pressure CO2 system refer unit failure alarms were not able to be tested. Determine testing procedures for refer unit alarms and prove operation to the satisfaction of USCG Marine Inspector.
Due 5 July 2014
Resolved 2 August 2014
Resolution: Received technician''s report attesting to repair, servicing, and testing of refrigeration unit alarms on LP CO2 system. Technician also liquid CO2 level gauge.
Construction/Loadline › Structures › Deck Plating
Issued 14 June 2014 Resolved
Gauging report produced by Chesteel Marine on 12 June 2014 indicates that a section of the deck plating between frames 10 and 13 on the starboard side of the car deck is corroded beyond allowable limits. Permanent repairs must be made to the subject area to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2015
Resolved 27 August 2014
Resolution: Subject area was cropped and renewed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 14 June 2014 Resolved
LP CO2 system onboard vessel is not specifically USCG approved. Provide all required documentation to USCG MSC and ENG-4 to gain approval of the installed system. Required submissions can be found in the ABS rules section 4 "Fixed Gas Fire-extinguishing Systems".
Due 14 July 2014
Resolved 27 January 2015
Resolution: Approval for the fixed CO2 system has been given by the MSC.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 February 2014 Resolved
Validate/verify LP CO2 system control, arrangement, instruction to USCG Approval. Historical record allude to USCG apporval, but no specific documentation and specific instructions are onboard. No stamped approved plans found. Plans found detail system somewhat differently than as installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 June 2014
Resolution: LP CO2 system is still not approved but Foss Intl. is making progress toward eventual certification. CG-835 has been revised to detail certification process step by step.
Fire Fighting › Fire Main › Condition
Issued 9 November 2012 Resolved
Provide repair plan for fractured blow down seachest line for firemain system. Prove proper operation of firemain system upon completion of repairs to the satisfaction of attending CG marine inspector, prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2012
Resolved 10 November 2012
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 October 2012 Resolved
Fire pump shaft seal failed leading to flooding of pump room and damage to associated electrical systems. Repair to satisfactio of attending marine insepctor prior to departure from Honolulu, HI.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2012
Resolved 9 November 2012
Electrical › Lighting (service) › Conductor
Issued 28 May 2010 Resolved
Close electrical junction box above CO2 control station after removing wire nuts and properly grounding armored cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2010
Resolved 23 August 2010
Resolution: Junction box was closed and proper connections made. Cables have been grounded to the junction box by reoving electrical tape.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 May 2010 Resolved
Replace line on lifebuoys with line that is black or dark in color in accordance with 46CFR 199.70(a)(3)(i).
Condition: Improper Installation
Due 28 June 2010
Resolved 23 August 2010
Resolution: Received photographic evidence that the line had been changed to the appropriate type and color.
Fire Fighting › Fire Main › Condition
Issued 28 May 2010 Resolved
Make permanent repairs to fire main stbd anchor house branch line. Pipe to be cropped to renewed to good metal. Temporary repairs to be maintained.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2010
Resolved 23 August 2010
Resolution: Received photographic evidence that the firemain was renewed in the wasted area.
Construction/Loadline › Structures › Door
Issued 28 May 2010 Resolved
Make permanent repairs to port and stbd anchor house watertight doors. Vessel to maintain adjustments to securing devices until permanent repairs are completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2010
Resolved 23 August 2010
Resolution: Received photographic evidence that the securing devices were corrected and the doors make a watertight fit.
Construction/Loadline › Structures › Deck Plating
Issued 28 May 2010 Resolved
Make proper electrical deck penetrations adjacent to door to fixed CO2 room. Sealer must be of an approved type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2010
Resolved 28 May 2010
Resolution: Penetration repaired using appropriate materials during the inspection.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 May 2010 Resolved
Properly blank electrical panels in swtchboard room.
Condition: Improper Installation
Due 28 May 2010
Resolved 28 May 2010
Resolution: Panels were being properly blanket at the time of inspectors departure.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 28 May 2010 Resolved
Provide plug in lube oil tank drain.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2010
Resolved 28 May 2010
Resolution: Plug has been installed.
Engineering › Fuel Oil Service System › Filter
Issued 28 May 2010 Resolved
Remove petcock from fuel filters and provide proper steel valve with plug.
Condition: Improper Installation
Due 28 June 2010
Resolved 28 May 2010
Resolution: Petcock was removed and plugged with steel plug. Valve is not required and will be installed at the C/E convenience.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 7 March 2008 Resolved
Company failed to give immediate notice following a marine casualty involving the collision with the vessel JEBEL ALI #6 in Umm Qusr port in Iraq on June 7, 2007.
Action required: 705 - Other - as specified
Resolved 1 October 2008
Resolution: NOV issued.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 7 March 2008 Resolved
The company failed to report a marine casualty in writing within five days to the OCMI following the vessel's collision with JEBEL ALI #6 in Umm Qasr port Iraq on June 7, 2007.
Action required: 705 - Other - as specified
Resolved 1 October 2008
Resolution: NOV issued.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Lack of Vessel Communication
Issued 7 March 2008 Resolved
Company made temporary repairs, without the knowledge of the OCMI, to the vessel's port side shell in between frames 17 and 18 as a result of a collision with JEBEL ALI #6 in Umm Qasr port Iraq on June 7, 2007.
Action required: 705 - Other - as specified
Resolved 1 October 2008
Resolution: NOV issued.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 March 2007 Resolved
CO2 system has no time delay on top release. Provide USCG or ABS acceptance of this arrangement.
Due 21 May 2007
Resolved 11 April 2007
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 March 2007 Resolved
Repair F/O containment for diesel fueling port and stbd. Current containment does not have a drain plug and is rotted.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 March 2007 Resolved
Repair/renew F/O containment for diesel fuel tank aft of the entrance to the CO2 room. Current containment is rotted and holed.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 23 March 2007 Resolved
Replace/Repair all flame screens on F/O vent heads.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Construction/Loadline › Hull › Bracket
Issued 23 March 2007 Resolved
Aft winch cable mount support brackets are rotted away. Replace as necessary
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 March 2007 Resolved
Label air receivers and gauges to match each other.
Due 21 May 2007
Resolved 11 April 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 March 2007 Resolved
Make the air receiver room water tight or provide documentation showing space does not need to be watertight.
Due 21 May 2007
Resolved 11 April 2007
Construction/Loadline › Structures › Deck Plating
Issued 23 March 2007 Resolved
Weather deck hand rail stanchions are rotted and several are broken. Replace as necessary.
Due 21 May 2007
Resolved 11 April 2007
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 23 March 2007 Resolved
Repair hydraulic leak on bow winch motor.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 March 2007 Resolved
Place inspection cover on CO2 tank.
Due 21 May 2007
Resolved 11 April 2007
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 23 March 2007 Resolved
Repair leaks and remove catch buckets from Port and Stbd deck winches.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 23 March 2007 Resolved
Remove paint from container on barge and place in paint locker.
Due 21 May 2007
Resolved 11 April 2007
Engineering › Compressed Air System (start air) › Valve
Issued 23 March 2007 Resolved
Remove pressure releif valves and have tested for proper setting
Due 21 May 2007
Resolved 11 April 2007
Stability › Watertight Integrity › General
Issued 23 March 2007 Resolved
Replace overboard discharge line in pump room bilge. The pipe currently has a large doubler on it.
Due 21 May 2007
Resolved 11 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2007 Resolved
Provide U/T gauging of the stbd pump room bulkhead.
Due 21 May 2007
Resolved 11 April 2007
Engineering › Fuel Oil Service System › Piping
Issued 23 March 2007 Resolved
Replace F/O pipe in locker by CO2 room.
Condition: Improper/Lack of Maintenance
Due 21 May 2007
Resolved 11 April 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 23 March 2007 Resolved
Remove vent for sewage tank and assosiated piping not in use.
Due 21 May 2007
Resolved 11 April 2007
Engineering › Diesel Engine (propulsion-electric) › Air Cleaner
Issued 23 March 2007 Resolved
Prove proper operation of both generators and all associated safeties without the use of starting aids. Currently the generators need to have the air filters removed and starting fluid injected.
Due 21 May 2007
Resolved 11 April 2007
Stability › Watertight Integrity › General
Issued 23 March 2007 Resolved
Remove expanding foam from wire runs and replace with marine/USCG approved packing material.
Due 21 May 2007
Resolved 11 April 2007
Engineering › Bilge Water Management System › Piping
Issued 23 March 2007 Resolved
Provide U/T gauging of the sea cheast line in the pump room.
Due 21 May 2007
Resolved 11 April 2007
Construction/Loadline › Structures › Deck Plating
Issued 23 March 2007 Resolved
Remove and replace rusted and holed deck plating in the pump room and all associated supports.
Due 21 May 2007
Resolved 11 April 2007
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 April 2005 Resolved
VESSEL FAILED TO HAVE ON BOARD THE ISSUED IOPP CERTIFICATE ISSUED BY MORMS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2005
Resolved 16 April 2005
Resolution: Original on board
Deck/Cargo › Ballast › Vents
Issued 7 April 2005 Resolved
Crop and renew wasted vent piping on stbd wing wall and renew vent check valve. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until Cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 7 April 2005 Resolved
Crop And renew port and stbd generator exhaust piping from deck up. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until Cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Deck/Cargo › Ballast › Vents
Issued 7 April 2005 Resolved
Open up port and stbd wing wall containments. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Accommodation/Occupational Safety › Ventilation › General
Issued 7 April 2005 Resolved
Crop and renew wasted supply ventilation trunk to cargo spaces on stbd side. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2005 Resolved
Replace fiberglass grating with steel in stbd anchor handling room. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 April 2005 Resolved
Install correct red lens on port side running light. Green lens is to be taped up until replacement is installed. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2005 Resolved
Weld hand rail to ladder. Ladder located on port side to wing wall. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Deck/Cargo › Ballast › Vents
Issued 7 April 2005 Resolved
Crop and renew wasted vents to the following tanks: 1P, 1C, 3P, 3C, 3S, 5P, and 5C. New piping is to be same as original. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2005 Resolved
Remove dead ended wire in Cargo hold forward stbd inway of chain locker. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Construction/Loadline › Structures › Deck Plating
Issued 7 April 2005 Resolved
Gouge and weld fracture on frame 30 at deck. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 7 April 2005 Resolved
Prove proper operation of parallel of barge generators and reverse power relays. 05 Jun 2005 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 7 April 2005 Resolved
Prove proper operation of port generator over speed. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Deck/Cargo › Cargo Stowage › General
Issued 7 April 2005 Resolved
Replace valve handles on all hydraulic deck winches. 05 Jun 2005 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 7 April 2005 Resolved
Update SOPEP to include requirements as required by 33 CFR 151.26(b)iii. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 7 April 2005 Resolved
Make bulkhead between cargo hold and machinery rooms equivalent to A-0. All unauthorized penetrations are to use approved penetrations systems. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 7 April 2005 Resolved
Install protective covers over CO2 activation valves to prevent tampering but still allow remote actuation in emergency. e.g. glass cover. 22Apr05 Reported Cleared Via mail with Photos, Items will remain opened until cleared by an attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 15 December 2005
Resolution: VERIFIED
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 December 2004 No resolution recorded
Vessel was involved with a collision with barge MMI605. Barge LIGHTNING sustained 1 hole on the bow abou 5 feet above water line. Also, sustained gash on port side of bow about 2 feet above water line. See narrative.
Action required: 705 - Other - as specified
Resolution: Attended barge. All damage was satisfactorily completed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 May 2003 Resolved
In the CO2 room above the ladder was an improper wire nutted wire splice without a junction box. Informed the master to have a proper junction box installed.
Condition: Improper Installation
Due 5 June 2003
Resolved 5 May 2003
Resolution: Contractor was called on scene and installed a junction box.
Engineering
Issued 28 March 2003 Resolved
Repair source of, and clean up excessive leakage from the hydraulic unit just fwd of the stbd generator room.
Due 28 April 2003
Resolved 5 May 2003
Resolution: Repaired source of leakage and cleaned up excessive oil on deck.
Engineering
Issued 28 March 2003 Resolved
Install sight glass guards on the hydraulic head tank above the hydraulic unit.
Condition: Unknown
Due 28 April 2003
Resolved 5 May 2003
Resolution: Sight glass guards were installed on the sight glass.
Construction/Loadline › Penetrations
Issued 28 March 2003 Resolved
Repair penetration that is open on a water tight bulkhead between the aft end of the cargo bay and the stairwell in the aft center portion of the vessel.
Due 28 April 2003
Resolved 5 May 2003
Resolution: Penetration was welded closed.
Electrical › Electric Generation Source (service)
Issued 28 March 2003 Resolved
Repair electrical connection to the jacket water heater on the stbd generator.
Condition: Unknown
Due 28 April 2003
Resolved 5 May 2003
Resolution: Connection was re-installed properly so that it was tight fitting with no bare wires showing.
Construction/Loadline › Structures
Issued 28 March 2003 Resolved
Repair the missing studs that hold the water tight cover on the manhole to the #7 stbd void. LEGACY COMPONENT DESC: Manhole
Due 28 April 2003
Resolved 5 May 2003
Resolution: New studs were welded on so the cover could be properly bolted down and made water tight.
Construction/Loadline › Penetrations
Issued 28 March 2003 Resolved
Install a mechanical plug on the "drain hole" in the cargo bay deck just below fire station #9. LEGACY COMPONENT DESC: Pipe Flange
Due 28 April 2003
Resolved 5 May 2003
Resolution: Mechanical plug was installed in the drain hole.
Fire Fighting
Issued 28 March 2003 Resolved
Replace the ax handle on the ax in the port side aft cargo bay by the door leading to the pump room.
Due 28 April 2003
Resolved 5 May 2003
Resolution: Fire ax was replaced with another.
Lifesaving › Lifebuoys
Issued 28 March 2003 Resolved
Replace retroreflective tape on the stbd forward life ring.
Due 28 April 2003
Resolved 5 May 2003
Resolution: Life ring was replaced with another.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 March 2003 Resolved
Replace life line on life ring on port aft corner of vessel.
Due 28 April 2003
Resolved 28 March 2003
Resolution: The entire ring was replaced before the end of the inspection.
Fire Fighting › Fire Hoses › Condition
Issued 28 March 2003 Resolved
Replace fire hose in pump room and remove damaged hose from vessel.
Due 28 April 2003
Resolved 28 March 2003
Resolution: Hose was replaced amd old hose had ends cut off by the end of the inspection.
Construction/Loadline › Hull
Issued 18 February 2003 Resolved
Make proper repairs to ballast pipe in No. 4 center ballast tank to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Ballast Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2003
Resolution: Examined repair and witnessed hydro test of pipe.
Construction/Loadline
Issued 18 February 2003 Resolved
Make proper repair to the fuel oil crossover pipe and prove repairs to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Fuel Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2003
Resolution: Examined repair and witnessed dye penetrant test of welds.
Construction/Loadline › Hull
Issued 18 February 2003 Resolved
Make No. 7 port and starboard void available for internal examination. LEGACY COMPONENT DESC: Internal Structure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2003
Resolution: Completed internal structural examination of void.
Construction/Loadline
Issued 18 February 2003 Resolved
Make proper repairs to centerline non-tight bulkhead in bow rake marked by ABS, and provide gauging report of collision bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2003
Resolution: Examined gaugine report from Q-Sea and found within allowances for wastages. ABS listed the 1" hole in the centerline non-tight bulkhead as an open item for completion of the hull survey.
Construction/Loadline
Issued 18 February 2003 Resolved
Properly clean and replace bilge strainers in machinery space. LEGACY COMPONENT DESC: Bilge strainers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 February 2003
Resolution: Examined both bilge strainers and found clean and properly installed.
Construction/Loadline › Structures
Issued 23 January 2003 Resolved
Make all voids and tanks available and ready for inspection by de-scaling and de-mucking.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2003
Resolved 20 February 2003
Resolution: Completed examination of all tanks and voids.
Engineering › Bilge Water Management System
Issued 23 January 2003 Resolved
Provide means of remotely operating valve forward of collision bulkhead as required by 46 CFR 56.50-1 (b) (1). LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2003
Resolved 19 February 2003
Resolution: Examined the reach rod and operation of valve.
Deck/Cargo
Issued 28 January 2002 Resolved
PROVIDE HYDROSTATIC HOSE TEST FOR FUEL HOSES OR REMOVE HOSES FROM BARGE. LEGACY COMPONENT DESC: FUEL HOSE
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Removed fuel hose from barge.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 January 2002 Resolved
PROVIDE TWO NEW CO2 DIFUSER HEADS IN CARGO BAY. LEGACY COMPONENT DESC: Nozzle
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2002
Resolved 30 January 2002
Resolution: Installed two new diffuser heads for fixed co2 in cargo space.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 January 2002 Resolved
PROVIDE SERVICING CERTIFICATE FOR ALL PORTABLE FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Servicing certificate for portable fire extinguisher were provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 January 2002 Resolved
PROVIDE SERVICING CERTIFICATE FOR FIXED CO2 EXTINGUISHING SYSTEM.
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Servicing certificate for fixed co2 system was provided.
Fire Fighting › Fire Hydrants
Issued 28 January 2002 Resolved
PROVIDE PROPER MARKINGS OF FIRE STATIONS AS REQUIRED BY 46 CFR 97.37-15
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: All fire stations were properly marked.
Engineering › Diesel Engine (propulsion-electric)
Issued 28 January 2002 Resolved
PROVIDE APPROVED FUEL FILTERS FOR PORT AND STBD GENERATOR AS REQUIRED BY 46 CFR 56.50-75. LEGACY COMPONENT DESC: FUEL FILTER
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Resolution: Sighted approved fuel filters mounted on port and stbd generators as required by 46 CFR 56.50-75.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 28 January 2002 Resolved
PROVIDE NAME PLATE DATA FOR PORT GENERATOR AS REQUIRED BY 46 CFR 111.12-5. LEGACY COMPONENT DESC: NAME PLATE DATA
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Resolution: Sighted new data plate mounted on port generator as required by 46 CFR 111.12-5.
Engineering › Diesel Engine (propulsion-electric)
Issued 28 January 2002 Resolved
PROVIDE GUARDS FOR BOTH GENERATORS EXHAUST EXPOSED TO MAIN DECK AS REQUIRED BY 46 CFR 111.12-5. LEGACY COMPONENT DESC: EXHAUST
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 28 February 2002
Resolution: Sighted new stainless steel guards, as required by 46 CFR 111.12-5, mounted over both generator exaust mufflers located on port and stbd maindeck.
Construction/Loadline › Structures
Issued 28 January 2002 Resolved
PROVIDE REPAIR PROPOSAL FOR CRACKS LOCATED ON THE PORT & STBD INBOARD BULKHEADS OF THE PORT & STBD GENERATOR SPACES. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Drill stopped both ends of cracks with 1/4" steel bit. Grinded cracks to create a 5/166" bevel on both sides. Then welded with 3/16" 7018 welding rods.
Construction/Loadline › Structures
Issued 28 January 2002 Resolved
REPAIR VENTILATION COVER ON MAIN DECK PUMP HOUSE AS REQUIRED BY 46 CFR 92.15-10(a). LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 30 January 2002
Resolution: Installed new ventilation cover.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 January 2002 Resolved
CROP AND RENEW WASTED STANCHIONS LOCATED ON STBD ACCESS TO MAIN DECK AS REQUIRED BY 92.25-5. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Cropped and renewed wasted stanchion.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 January 2002 Resolved
INSTALL LOWER RAIL COURSE IN WAY OF STBD GENERATOR EXHAUST 46 CFR 92.25-5.. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Resolution: Installed new rail course.
Construction/Loadline
Issued 27 September 2001 Resolved
Make the number 8 port void available for visual inspection by marine inspector.
Condition: Unknown
Due 27 September 2001
Resolved 27 September 2001
Construction/Loadline
Issued 27 September 2001 Resolved
Crop and renew suction ballast piping with doubler patches. Repairs to be tested and witnessed to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 27 September 2001
Resolved 27 September 2001
Electrical
Issued 30 May 2001 Resolved
Renew improper size/type electrical cable to water fountain located in aft stairwell leading to cargo bay. See 46 CFR 111.60.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Lifesaving
Issued 30 May 2001 Resolved
Install retaining bracket/strapping to newly installed potable water head tank located in the ballast pump room.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 30 May 2001 Resolved
Provide and/or update directory of circuits for each electrical distribution panels throughout the vessel. See 46 CFR 111.30-15
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 30 May 2001 Resolved
Install blank circuit breaker covers to 440 electrical distribution panel in switchboard compartment where circuit breakers are missing to prevent accidental shock. See 46 CFR 111.01-1
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Accommodation/Occupational Safety
Issued 30 May 2001 Resolved
Handrail located on portside ladder in cargo bay was broken at the weld to the deck. See 46CFR 42.15-75.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Documentation › Safety/Response Plans/Programs
Issued 30 May 2001 Resolved
Provide valid Shipboard Oil Pollution Emergency Plan(SOPEP) on board vessel as per 33 CFR 151.29 and MARPOL 73/78 Annex I. LEGACY COMPONENT DESC: SOPEP
Due 1 June 2001
Resolved 18 December 2001
Resolution: Sighted valid SOPEP issued 01JUN01 with an expiration date of 20FEB06.
Electrical
Issued 30 May 2001 Resolved
Renew electrical cable to emergency light located in the electical switchboard compartment. Prove operation of emergency light once repairs are completed. See 46 CFR 111.60
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 30 May 2001 Resolved
Renew or repair inoperable fire nozzle located at fire station #9 in the ballast pump room. See 46CFR 91.25-20 (a).
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 30 May 2001 Resolved
Install captive chains to all fire nozzle tips throughout the vessel._x001C_ See 46 CFR 91.25-20
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 30 May 2001 Resolved
Install guard over vent fan opening located in the ballast pumproom in accordance with 46 CFR 92.25-15.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 30 May 2001 Resolved
Locate,isolate and remove electrical ground indicated on the electrical switchboard. See 46Cfr 111.05-11.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Lifesaving
Issued 30 May 2001 Resolved
Remove flammable paint products in mid-stairwell area place in flammable storage area/locker. See 46CFR 92.05-10.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 30 May 2001 Resolved
Renew damaged section of CO2 control piping inway of epoxy patch located inaft stairway leading to cargo bay. See 46CFR 95.15-15.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 30 May 2001 Resolved
Repair/renew and prove operation of CO2 alarm in cargo bay. See 46CFR 95.15-30.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 30 May 2000 Resolved
LABEL CO2 STATION IN PORT ANCHOR HOUSE. "CO2 APPARATUS" IN 2IN LTRS.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Engineering
Issued 30 May 2000 Resolved
REPLACE AIR CLEANER HOUSING ON STBD GENERATOR.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Fire Fighting
Issued 30 May 2000 Resolved
REPLACE FIRE ALARM LIGHT W/ RED LENS.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Engineering
Issued 30 May 2000 Resolved
REPLACE HEAT SHIELD ON EXHAUST PIPING ON BOTH GENERATORS (ELBOWS).
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Fire Fighting
Issued 30 May 2000 Resolved
POST CO2 WARNING SIGNS IN CARGO BAY AT EYE LEVEL.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Fire Fighting
Issued 30 May 2000 Resolved
POST FIRE ALARM WARNING SIGN WORDED IAW 46 CFR 97.37-7.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Engineering
Issued 30 May 2000 Resolved
REPLACE PLASTIC WIRE TIES ON GENERATOR SETS & REPLACE W/ METAL CLAMPS.
Condition: Unknown
Due 21 June 2000
Resolved 29 September 2000
Accommodation/Occupational Safety
Issued 27 May 1998 Resolved
REPLACE CRACKED WINDOW IN WATERTIGHT DOOR SERVING STARBOARD AFTER GENERATORROOM PER 46 CFR 72.05-25.
Condition: Unknown
Due 27 June 1998
Resolved 3 July 1998
Electrical
Issued 27 May 1998 Resolved
PLUG ELECTRICAL ENTRANCES INTO PANEL IN PORT GENERATOR ROOM PER 46 CFR 111.40.
Condition: Unknown
Due 27 June 1998
Resolved 3 July 1998
Construction/Loadline
Issued 7 May 1997 Resolved
INSTALL REMOTE OPERATED VALVES FOR THE SEA CHESTS LOCATED IN TANK 6PA, OPERABLE ABOVE THE MAIN DECK.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Fire Fighting
Issued 29 May 1996 Resolved
Repair liquid level gauge in bulk CO2 system & provide documentation of annual servicing.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Engineering
Issued 29 May 1996 Resolved
Install containment around portable fuel tank for deck generator.
Condition: Unknown
Due 15 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 29 May 1996 Resolved
Remark deck line, port side.
Condition: Unknown
Due 15 June 1996
Resolved 13 June 1996
Engineering
Issued 29 May 1996 Resolved
Demonstrate remote shutdown, overspeed, low lube oil, high jacket water trips on port generator.
Condition: Unknown
Due 15 June 1996
Resolved 13 June 1996
Engineering
Issued 29 May 1996 Resolved
Demonstrate engine safety trips on deck generator.
Condition: Unknown
Due 15 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 13 June 1995 Resolved
COMPLETE WELDS ON THE 11TH AND 12TH SIDE LONGITUDINALS (FROM BOTTOM) IN WAYOF THE 4TH FRAME AFT FROM FORWARD BULKHEAD IN #4 PORT FORWARD BALLAST TANK.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Electrical
Issued 13 June 1995 Resolved
RENEW LIGHT FIXTURE LENS PORT SIDE AFT ON UPPER DECK.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Construction/Loadline
Issued 13 June 1995 Resolved
COMPLETE PERMANENT REPAIRS TO THE #5 CENTER BALLAST TANK. REPAIRS ARE TO BECOMPLETED TO THE SATISFACTION OF AN ATTENDING INSPECTOR AT THE VESSEL'S NEXT DRYDOCKING.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Construction/Loadline
Issued 13 June 1995 Resolved
RENEW BOLTS MISSING ON THE FOLLOWING MANHOLE COVERS: NO. 4 CENTER AFT(8), NO. 1 PORT & STBD FWD (6), NO. 2 CENTER FWD(13), NO. 3 CENTER FWD(7), NO. 2CENTER AFT(6), AND NO. 1 STBD AFT(5).
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Accommodation/Occupational Safety
Issued 13 June 1995 Resolved
REPAIR BROKEN UPPER RAIL ON UPPER DECK PORT SIDE MIDSHIPS.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Accommodation/Occupational Safety
Issued 13 June 1995 Resolved
RENEW BROKEN RAIL STANTION ON UPPER DECK FORWARD STBD SIDE.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Documentation
Issued 20 October 1994 Resolved
PROVIDE APPROVED REVISED TRIM AND STABILITY LETTER INCORPORATIONG 3RD TIER CONTAINER LOADING
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Fire Fighting
Issued 12 August 1994 Resolved
RENEW/REPAIR CO2 TANK LIQUID LEVEL GAUGE TO 12.5 TON LOW-PRESSURE CO2 TANK.
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Fire Fighting
Issued 12 August 1994 Resolved
COMPLETE INSTALLATION OF LOW-PRESSURE FIXED CO2 PIPING (DIRT TRAPS,DEAD-ENDEXTENSIONS AND CAPS) IN WAY OF CARGO HLD AS SHOWN ON APPROVED DWGS.
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Fire Fighting
Issued 6 June 1994 Resolved
SUBMIT PLANS TO THE USCG MARINE SAFETY CENTER AND RECEIVE APPROVAL FOR THELOW PRESSURE FIXED CO2 FIRE SUPPRESSION SYSTEM.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Electrical
Issued 6 June 1994 Resolved
UPON FINAL INSTALLATION OF GENERATOR SWITCH BOARD PANEL LOCATED IN PORT GENERATOR ROOM, PROVE PROPER OPERATION OF SYSTEM.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Construction/Loadline
Issued 6 June 1994 Resolved
CHALK TEST BOW DOOR AND EXAMINE GASKET FOR PROPER CONDITION.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Deck/Cargo
Issued 12 June 1992 Resolved
PERMANENTLY INSTALL APPROVED VENTS FOR CARGO DECK IN WAY OF FORWARD WEATHERDECK HOUSES.
Condition: Unknown
Due 12 July 1992
Resolved 9 September 1992
Fire Fighting
Issued 12 June 1992 Resolved
CHARGE AND PROVE PROPER OPERATION OF LOW PRESSURE FIXED CO2 FIRE FIGHTING SYSTEM PRIOR TO LOADING OF DECK CARGO.
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992
Deck/Cargo
Issued 12 June 1992 Resolved
PROPERLY STENCIL ALL CARGO HOSES.
Condition: Unknown
Due 12 July 1992
Resolved 9 September 1992
Construction/Loadline
Issued 12 June 1992 Resolved
PROVE PROPER OPERATION OF STARBOARD ANCHOR AND WINDLASS BY DROPPING AND WEIGHING ANCHOR.
Condition: Unknown
Due 12 July 1992
Resolved 9 September 1992
Electrical
Issued 12 June 1992 Resolved
INSTALL BLANKS IN ALL SWITCH BOX OPENINGS.
Condition: Unknown
Due 12 July 1992
Resolved 9 September 1992

Ownership record