Records from 1991 to 2008. Most recent: inspection, 16 July 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
16 July 2008
MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3267712
29 April 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2633243
20 June 2005
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2396601
24 April 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2334927
25 February 2004
Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2007867
30 April 2002
Passenger/Freight Vessel Examination · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1608781
6 June 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 429432
16 October 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 408785
2 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402074
6 March 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 401252
10 February 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 341809
Fire Fighting › Means of Escape › Doorways
Issued 22 June 2005
Resolved
Fire escape doors in machinery spaces and escape corridors must be self closing, to include doors in main control and all escape trunks
Action required: 15 - Rectify deficiencies by next port
Due 22 July 2005
Resolved 29 April 2006
Resolution: After reviewing the Fire Control Plan noticed that Main Control was not a class "A" boundary. Therefore, not requiring self-closing doors.
Electrical › Electric Generation Source (service) › Generator
Issued 24 April 2005
Resolved
#1 SSDG needs maintenance allowing it to operate with a full electrical load. SOLAS 74/78 Ch.2-I Reg. 41
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 May 2005
Resolved 22 June 2005
Resolution: #1 SSDG repaired and in proper working order.
Fire Fighting
Issued 6 June 1999
Resolved
FIRE FIGHTING DRILL CONDUCTED IMPROPERLY, LIFE LINES TANGLED, ELEC. POWER NOT SECURED, EQUIPMENT NOT PROPERLY DEPLOYED. VIOLATION OF SOLAS 74(AMD) REG III-18
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 6 June 1999
Resolved
PARACHUTE FLARES ON BOARD DO NOT MEET SOLAS 74 (AMD) CH3 REG 35. SEE DEFICIENCY CITATION SOLAS 74(AMD) REG III - 6.3
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Lifesaving
Issued 6 June 1999
Resolved
FLARES, SMOKE AND FLARES, ROCKET ON LIFE BOATS DO NOT MEET SOLAS 74(AMD) REG 35, 36, AND 37. SEE SOLAS 74(AMD) REG# 41.8
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 16 October 1997
Resolved
SIDEPORT LOCATED ON THE STARBOARD SIDE BETWEEN FRAMES 85 AND 87 AT THE WATERLINE IS INDENTED AND TEMPORARILY REPAIRED WITH CEMENT. PERMANENT REPAIRS TO BE MADE TO THE SATISFACTION OF CLASS AND A CLASS SURVEYORS REPORT SHALL BE PROVIDED THE THE OCMI PRIOR TO THE NEXT US PORT.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Lifesaving
Issued 6 March 1997
Resolved
PROVIDE WATERLIGHTS FOR ALL IMMERSION SUITS I.A.W. SOLAS 74 AMENDED III/33.1.4.
Condition: Unknown
Due 10 March 1997
Resolved 11 March 1997
Construction/Loadline
Issued 6 March 1997
Resolved
REPAINT LOADLINE AND DRAFT MARKS IN CONTRASTING COLORS PRIOR TO REENTRY INTO U.S. WATERS.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Navigation
Issued 6 March 1997
Resolved
PROVIDE CURRENT TIDE TABLES, TIDAL CURRENT TABLES AND LIGHT LIST PRIOR TO DEPARTURE FOR PORT OF DUTCH HARBOR.
Condition: Unknown
Due 10 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 6 March 1997
Resolved
REMOVE HOLDBACK HOOKS FROM ALL STAIRWAY A-60 DOORS I.A.W. SOLAS 74 AMENDED_x001C_II-2/47.2 REQUIREMENTS.
Condition: Unknown
Due 10 March 1997
Resolved 11 March 1997