Records from 2011 to 2025. Most recent: inspection, 6 June 2025.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 6.5 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARRO YACHTS INC · ARUNDEL, ME, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBATH, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
6 June 2025
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8153760
19 December 2024
Construction Oversight · Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8049584
15 August 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7981979
8 May 2023
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7684600
16 August 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7538053
2 August 2022
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7523728
2 August 2022
Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7528707
23 June 2022
DAPI Audit
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7484982
31 August 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7301345
29 December 2020
Construction Oversight · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7135806
24 June 2020
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6985828
15 November 2018
Drydock Exam · Administrative Inspection · Construction Oversight · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6583617
2 July 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6464347
7 February 2018
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6351045
8 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6241523
26 January 2017
Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6082457
31 October 2016
Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6034148
26 July 2016
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5954367
26 July 2016
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5973654
24 May 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5885521
21 March 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5837403
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2022
Resolved
Fireboy system: Tested engine shut-downs when fireboy simulated discharged. Engines secured, but could be restarted when not in override.
Waiting for tech report.
Action required: 705 - Other - as specified
Due 19 September 2022
Resolved 9 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 August 2021
Resolved
Bulkhead penetration on forward bulkhead of engine room unable to provide vapor barrier.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 8 October 2021
Resolution: Barriers properly caulked.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 August 2021
Resolved
Provide proof that the smoke/heat detectors in engine room have been tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 7 September 2021
Resolution: Third party report from AAA fire servicing company provided. System serviced in May.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2021
Resolved
Hoses on engine did not have double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 8 October 2021
Resolution: Double clamps provided.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 August 2021
Resolved
Labels for fuel shut offs were peeling off the deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 8 October 2021
Resolution: Fuel shut offs labelled.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 31 August 2021
Resolved
Crew needed coaching for engine room fire drill. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 14 September 2021
Resolved 31 August 2021
Resolution: Provided training at time of inspection and crew knows what to do in the event of an engine room fire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2020
Resolved
Life ring lines not routed around body of life ring.
Due 9 July 2020
Resolved 7 August 2020
Resolution: Life rings fixed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 June 2020
Resolved
Master could not provide license or FCC operators permit.
Due 9 July 2020
Resolved 7 August 2020
Resolution: Captain provided permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2020
Resolved
Vessel did not have a valid COI and was operating.
Due 25 June 2020
Resolved 25 June 2020
Resolution: Issued vessel new COI at completion of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 25 June 2020
Resolved
Vessel could not provide a current FCC Safety Radio Telephony Cert.
Due 9 July 2020
Resolved 7 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 June 2020
Resolved
Crew could not demonstrate operation of all bilge alarms. Engine room and Laz alarms never went off.
Due 9 July 2020
Resolved 7 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2020
Resolved
Child life jackets not properly segregated from adult life jackets on seond deck.
Due 9 July 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2020
Resolved
Crew could not demonstrate proper operation of pre-engineered firefighting system automatic engine shut offs and overide.
Due 9 July 2020
Resolved 7 August 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 June 2020
Resolved
Holes in wateretight bulkheads from old wiring harnesses. Make all watertight bulkheads watertight.
Due 9 July 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020
Resolved
MI noted various unauthorized portable lighting systems on vessel. Remove all unauthorized lights and electric,
Due 9 July 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020
Resolved
Fuel filters had drain plugs on bottom. Remove/plug as needed to prevent fuel spills/fire hazard.
Due 9 July 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2020
Resolved
Label Fuel Shut-offs on main deck.
Due 9 July 2020
Resolved 7 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2019
Resolved
Charts not current or corrected; maintain current or corrected charts. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 6 August 2019
Resolution: Charts Provided
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 10 July 2019
Resolved
Emergency Instruction List not posted, as per 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 6 August 2019
Resolution: Emergency Instructions Posted
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 10 July 2019
Resolved
Waste Management Plan not posted; WMP to be posted IAW 33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 6 August 2019
Resolution: Waste Management Plan posted
Operations/Management › Vessel Activity › Underway
Issued 26 July 2016
Resolved
Prior to operating the vessel complete damage survey.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2016
Resolved 27 July 2016