← All vessels
HAIG POINT III
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named HAIG POINT III
HAIG POINT III is a 1991 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1991, most recently in April 2026, along with 40 deficiencies, 3 operational controls and 1 casualty investigation in 2005.
Records from 1991 to 2026. Most recent: inspection, 28 April 2026.
- Built
- 1991
- Last inspected
- 28 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 40 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2005
Identity
973643
WDJ8243
360580
Flag
UNITED STATES
367140710
Maury page id
psix-360580
Inspections, by type
…with no type recorded1
Years with a record
32 calendar years (1991–2026)
The 59 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)35.8 ft × 12.7 ft × 7.5 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFLYE POINT MARINE, INC. · BROOKLIN, ME, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDAUFUSKIE ISLAND, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
22 - Simplified, Gross Ton
22 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK5975MMSI 368070060 · cancelled · compulsorily equipped · granted 15 December 2018, cancelled 14 February 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDJ8243MMSI 367140710 · active · compulsorily equipped · granted 30 November 2017, expires 30 November 2027
WDD4140MMSI 367140710 · expired · compulsorily equipped · granted 20 September 2006, cancelled 26 November 2016
WCW8659MMSI not assigned · expired · compulsorily equipped · granted 13 September 1996, cancelled 13 November 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 59
28 April 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8358874
7 November 2025
Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8265828
23 August 2025
In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8216373
11 March 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8093708
30 April 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7905845
18 March 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7880800
16 November 2023
Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7825861
14 February 2023
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7582740
27 January 2023
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7627903
25 January 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7385816
9 November 2021
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7344654
7 December 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7104096
19 March 2020
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6893637
14 November 2019
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6855606
5 February 2019
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6624391
1 December 2016
COI Inspection · Plan Review "T" Boat · Simplified Stability Test · Hull Examination · Construction Oversight · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6060542
21 January 2016
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5801983
19 November 2015
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5865554
25 June 2014
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4901918
22 February 2012
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4249681
15 December 2010
Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3911294
3 February 2010
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3673233
6 April 2009
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3447044
15 January 2009
Construction Oversight
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3395213
16 December 2008
Administrative Inspection · Drydock Exam · Deficiency Check · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3380538
1 April 2008
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3175354
4 June 2007
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2947183
16 April 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2908734
3 March 2006
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2595433
7 June 2005
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2397034
10 March 2005
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2307086
31 January 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2292292
22 March 2004
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2028882
21 May 2003
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1797301
3 April 2003
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1767174
20 March 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1495841
22 June 2001
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406965
26 March 2001
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1060406
26 March 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1429512
22 March 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1412065
30 June 1999
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1457670
15 April 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 788718
24 March 1999
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1395149
29 April 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 790306
23 March 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1378324
22 July 1997
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1418185
25 March 1997
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1450012
2 April 1996
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1414603
12 May 1995
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1427061
29 March 1995
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1417750
29 March 1994
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1459859
3 November 1993
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1470374
11 August 1993
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1156084
31 March 1993
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1370571
2 October 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1393870
6 April 1992
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 945881
11 October 1991
Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 939250
10 April 1991
Initial Certification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 932823
2 April 1991
Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 922336
Deficiency record · 40
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 August 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction.
Railing on starboard quarter is damaged due to a collision with a recreational vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 August 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Vessel hull found to have damage around both starboard side through hull penetrations. Repairs must be completed prior to the issuance of drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 August 2025
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may require the vessel to be drydocked or taken out of service to assess the extent of the damage.
Vessel must conduct drydock to the satisfaction of the attending marine inspector prior to carriage of passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (d) External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Port and starboard fuel tanks have been leaking #2 marine diesel into the bilge for approx. three weeks. Find source of leak and conduct pressure test of F/O tanks at 5 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2022
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. The exhaust elbow at the turbocharger is leaking exhaust into the passenger compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2022
Resolved
Except as otherwise provided in paragraphs (b), (c), (d), and (e) of this section, all engines must be water cooled and meet the requirements of this paragraph.
(1) The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. During operational test of the propulsion engine, the expansion tank cap was leaking coolant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2022
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Conduct a pressure test of the propulsion engine's jacket water cooling system according to manufacturer instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2022
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously. The aft railing was missing twelve fasteners for the railing mounts at various locations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 January 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. The high water level alarm in the steering compartment did not actuate when tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has only 25 Serviceable Life Jackets. Total Persons allowed is reduced to 25.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2020
Resolved
Ring Buoys must be have the name of a vessel marked or painted in clearly legible letters and numbers and be approved in accordance with §160.050 in subchapter Q of this chapter, Retro reflective tape is missing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 December 2020
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Aft hatch leading to Steering gear compartment is leaking during hose test.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 March 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessels markings for both port and starboard side are missing. The vessel will be restricted from carrying passengers after April 19, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR185.608
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2020
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual alarm at the operating station to indicate a high water level not working for Lazzerette. The vessel will be restricted from carrying passengers after April 19, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR182.530(a) and 46CFR182.115(d)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 March 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessels Aspirin, Antiseptic Towelettes, Large Gauze Compress, Burn Gel, Ammonia Inhalants, Eye Wash, Triangular Bandage are expired. The vessel will be restricted from carrying passengers after April 19, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR184.710 and 46CFR184.115(c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2019
Resolved
Fuel shut off sign
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2019
Resolved
Bilge hand pump inoperable
Electrical › Lighting (service) › Lighting Fixture
Issued 30 November 2017
Resolved
Replace 12 volt lighting fixtures in main salon with approved fixtures.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 November 2017
Resolved
Properly mark forward emergency escape.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 November 2015
Resolved
Repalce 40 amp breaker on genset with 35 amp breaker.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 June 2014
Resolved
Label exterior of bow both port and starboard with vessel name. Cite: 46 CFR 67.123
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 June 2014
Resolved
Label lifebuoys with vessel name, and replace/repair water light. Vessel limited to daytime operation until water light works properly. Cite: 46 CFR 180.70(d) & 46 CFR 185.604(b)
Fire Fighting › Means of Escape › Doorways
Issued 26 June 2014
Resolved
Replace/repair latch on door leading into the house. Cite: 46 CFR 177.15-1(a)
Electrical › Electric Supply System (service) › Cable
Issued 6 April 2009
Resolved
Properly cap off or remove dead end wires located in both the engine room space and the forward head.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 6 April 2009
Resolved
Properly repair port quarter railing.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 December 2008
Resolved
Properly repair or renew vessels' stbd fuel tank i.a.w. 46 CFR182.440. Final inspection of fuel tank and installation must be witnessed and approved by the attending CG Marine Inspector prior to carrying passengers.
Stability › Watertight Integrity › General
Issued 14 June 2007
Resolved
Vessel had a pinhole in the lazarette where they rub rail did not have all the screws in it.
Construction/Loadline › Hull › Stringer
Issued 7 June 2005
Resolved
Provide survey report for moisture content on E/R port stringer reglassed area.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 June 2005
Resolved
Make all sea valves available for inspection.
Construction/Loadline › Hull › Stiffener
Issued 7 June 2005
Resolved
Repair rotted overhead wood stiffener in E/R next to port MDE.
Construction/Loadline › Hull › Hull Plating
Issued 7 June 2005
Resolved
Remove old transducer from FWd STBS hull and repair glass to satisfaction of marine inspector.
Construction/Loadline
Issued 24 March 1999
Resolved
Install audible alarm for lazarette bilge system.
Fire Fighting
Issued 24 March 1999
Resolved
Prove proper operation of generator blower shutdown as required for fixed fire extiguishing system.
Engineering
Issued 24 March 1999
Resolved
Prove proper operation of loss of cooling alarm for wet exhaust system. Visible and audible alarm are required at the operating station.
Fire Fighting
Issued 23 March 1998
Resolved
Provide servicing of all portable fire fighting appliances as required by 46 CFR 176.810.
Fire Fighting
Issued 29 March 1994
Resolved
Service installed fixed HALON system and make repairs to shutdown for generator when HALON system used.
Construction/Loadline
Issued 6 April 1992
Resolved
VSL NEEDS CAPTURE DEVICE INSTALLED ON HATCH OVER LAZARETTE.
Lifesaving
Issued 6 April 1992
Resolved
VSL NEEDS 3 ADULT TYPE I PFDS.
Fire Fighting
Issued 10 April 1991
Resolved
DEMONSTRATE PROPER OPERATION OF THE POWER VENTALATION SHUTDOWN BY THE FIXEDHALON SYSTEM.
Lifesaving
Issued 10 April 1991
Resolved
TOTAL PERSONS ALLOWED IS LIMITED TO THIRTY-TWO (32) UNTIL TWO (2) ADDITIONAL COAST GUARD APPROVED TYPE 1 ADULT SIZE LIFE PRESERVERS ARE PROVIDED, FOPR A TOTAL OF THIRTY-FOUR (34).
Casualty record · 1
31 January 2005Routine · role: Involved in a Marine Casualty · activity 2292292
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.