MAURY USCG vessel records Sign in
← All vessels

SUSAN HUDSON

SUSAN HUDSON is a 1991 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1991, most recently in July 2026, along with 104 deficiencies and 1 operational control.

Records from 1991 to 2026. Most recent: inspection, 27 July 2026.

Built
1991
Last inspected
27 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI2503
360762
Flag
UNITED STATES
367678840
Maury page id
psix-360762

Inspections, by type

…with no type recorded10
Years with a record 29 calendar years (1991–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 37 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUSTOM DESIGN SERVICES · FULTON, TX, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
37 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP7993MMSI 367678840 · active · compulsorily equipped · granted 7 September 2024, expires 7 September 2034
WDI2503MMSI 367678840 · cancelled · compulsorily equipped · granted 16 June 2015, cancelled 9 May 2024
WAV3642MMSI 367117050 · expired · voluntarily equipped · granted 26 May 2006, cancelled 6 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

27 July 2026 Type not recorded
No type recorded · USCGC LAWRENCE O. LAWSON (WPC 1120) · USCG East District (CGD-E) · Activity 8449779
29 October 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8259445
7 May 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8130938
5 March 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8088786
21 January 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8066700
6 March 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7874901
14 December 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7838697
16 August 2023 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769624
12 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7667853
3 November 2022 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7587954
28 October 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7339523
27 September 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7321499
20 October 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7080965
22 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6839335
27 September 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6822797
9 April 2019 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659003
19 October 2017 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6290134
5 October 2017 Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6280270
5 January 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065968
19 November 2015 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5766929
2 August 2014 Hull Examination · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5143335
15 December 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3650554
28 April 2009 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3465191
15 April 2009 Annual Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3452914
26 February 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3156411
19 November 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3104693
9 April 2007 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2904591
26 February 2007 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2877674
7 December 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2547713
1 March 2005 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2300897
4 November 2004 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2234546
24 February 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2012144
7 November 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1945014
8 November 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702646
21 February 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1488021
8 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075697
16 April 2001 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1471247
5 October 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 102216
10 March 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418674
2 March 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1436336
21 October 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 23164
14 October 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 139569
9 March 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1381493
16 February 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1390940
27 March 1998 Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 787733
10 March 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121410
16 January 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1111444
8 April 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1106865
10 March 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1105412
14 May 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1084312
7 May 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082458
15 April 1996 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1081101
4 April 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1081103
28 November 1995 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 880918
20 April 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1340529
14 March 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 827372
5 April 1994 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1166561
12 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1164194
13 October 1993 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1148152
12 April 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 838085
19 October 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 937229
7 April 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1256264
31 March 1992 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258985
4 November 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1252192
11 June 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1017188
19 April 1991 Initial Certification · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1230309

Deficiency record · 104

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2025 Resolved
Short lengths of approved non metallic flexible hose, fixed by two hose clamps at each end of the hose, may be used at machinery connections for a keel cooler installation. MI observed starboard main engine keel cooler hose damaged resulting in slight drip of coolant in space. Replace hose to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2025
Resolved 5 March 2025
Resolution: Recevied, reviewed, and approved pictures showing keel cooler flexible hose has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2025 Resolved
The owner shall ensure vessel is equipped with a vessel master key control system. Vessel must have list of all crew (identified by position) allowed to access key and kept in a logbook with dates/times, rooms, and name/rank of crew member when crew utilizes master key (can be electronic, must be readily available).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2025
Resolved 5 March 2025
Resolution: Vessel has removed padlock key from head to meet the requirements of USC 3106
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022 Resolved
The cooling water strainer on the vessel's generator was zip-tied in place. Make appropriate permanent repairs ensuring that the strainer is secured. 46 CFR 182.10-1 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 2 December 2022
Resolution: Def cleared
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 October 2020 Resolved
A separate circuit, fused at the main distribution panel shall be provided for each radio-phone installation. Provide separate over current protection for each VHF radio installation. - 46 CFR 183.05-25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 9 November 2020
Resolution: Second VHF moved to spare circuit breaker in main panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2020 Resolved
Switches other than those mounted on the switchboard shall be of the enclosed type. Radio amplifier installed in wheelhouse had a circuit breaker hanging in the overhead creating a hazard. Amplifier was also not subject to plan review/approval process. Remove audio amplifier, circuit breaker and associated wiring. - 46 CFR 183.05-15(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 9 November 2020
Resolution: Amplifier and hanging circuit breaker removed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 October 2020 Resolved
Life floats need to be stowed in such a manner as to enable crew members to manually launch in an emergency. The current length of line attaching the top life float to the bottom life float does not allow a crew member to lower the top life float to the point of embarkation without also having to move the second life float along with it. - 46 CFR 180.130(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 9 November 2020
Resolution: Painter between life floats extended.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2020 Resolved
Emergency escape hatch is not labeled on the outside. Label hatch in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR". - 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 9 November 2020
Resolution: Proper labeling has been applied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2019 Resolved
Install positive shutoff valve at the hull penetration for the submersible bilge pump in the lazarrette. 46CFR182.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 23 October 2019
Resolution: Operator installed a 1/4 turn ball valve.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 October 2019 Resolved
Grind cracks found on the circular insert located in the forepeak. Make available for inspection, due December 15th, 2019. 46CFR176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 30 June 2020
Resolution: Cleared def, this was resolved at a follow up inspection last fall/winter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2019 Resolved
Remove cooler or install waterproof GFCI outlet to service cooler. Cap penetration in bulkhead. 46CFR183.10-20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 30 June 2020
Resolution: Cleared def, this was resolved at a follow up inspection last fall/winter.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 September 2019 Resolved
Provide spacers between life floats. - 46 CFR 180.137(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 9 October 2019
Resolution: Received photographs of the spacers from the O/O.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 April 2019 Resolved
Install life float. Passenger count limited to 22 persons until new life float provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 3 May 2019
Resolution: Owner purchased and installed new life float.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 April 2019 Resolved
Remove and replace #2 bilge alarm light bulb.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 3 May 2019
Resolution: Light bulb replaced.
Engineering › Bilge Water Management System › Not Operational
Issued 23 April 2018 Resolved
07126 Remove excessive oil from engine room bilge prior to carrying passengers. 46 CFR 182.100. 701 c.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2018
Resolved 24 April 2018
Resolution: Crew satisfactorily removed oil from bilge.
Engineering › Reduction Gearing/Clutches › Hose
Issued 23 April 2018 Resolved
09210 Replace hose on port reduction gear that is leaking. Find and repair oil leaks on both diesel engines by May 7, 2018. 46 CFR 182.100 16c.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 24 April 2018
Resolution: Leaks fixed and engine room was cleaned.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 October 2017 Resolved
PWG 01 Prove Proper operation of #3 Bilge High Water Level Alarm. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 19 October 2017
Resolution: Corrected on the spot
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 19 October 2017 Resolved
PWG 02 Replace/reinstall engine mount bolts underneath reduction gear port engine. 46CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 23 April 2018
Resolution: Bolts were reinstalled
Engineering › Fuel Oil Service System › Suction Strainer
Issued 19 October 2017 Resolved
PWG 03 Place metallic plug on bottom of starboard fuel strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 24 April 2018
Resolution: Crew installed plugs on bothe main engine strainers.
Construction/Loadline › Structures › Manhole
Issued 19 October 2017 Resolved
PWG 04 Place metallic securing cable on forepeak watertight hatch. 46CFR"Old S" 171.124(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 23 April 2018
Resolution: Metallic restaining cable installed on bth fore peak and acccomodation watertight hatches.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 19 October 2017 Resolved
PWG 05 Have all Captains obtain Marine Operators Permit from FCC before operating outside 20nm. 47 CFR 80.155
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: For documentation purposes. Vessel is on an OCEANs route but none of the normal captains have a Marine Operators Certificate.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 October 2017 Resolved
PWG 06 Be able to conduct post casualty alchol testing with in 2 hours. Alcohol test strip are expired. 46 CFR 16.240
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 October 2017 Resolved
PWG 07 - Log all Fire and Abandon Ship Drills. 46 CFR 185.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Corrected on the Spot
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2017 Resolved
PWG 08 - Log monthly, quarterly, and annual lifesaving equipment inspections. 46 CFR 185.726(d)
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Corrected on the spot
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2017 Resolved
PWG 09 - Log monthly EPIRB Checks. 46 CFR 185.728
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Corrected on the Spot.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 October 2017 Resolved
Waterlines penetrate the collision that are incable of being made watertight. Add valves immediately aft of collision bulke head on waterlines. 46 CFR "Old S" 171.090(g)(3)(ii)
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 24 April 2018
Engineering › Bilge Water Management System › Pump
Issued 5 January 2017 Resolved
Prove proper operation of fixed power bilge pumps. Engine driven bilge pump could not get suction from the E/R bilge. Rule pumps on board do not meet UL1113 standard. IAW 46CFR182.25-10(d).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2017
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 January 2017 Resolved
Provide approval documention for vessel marine sanitation device.
Due 5 February 2017
Resolved 26 January 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2017 Resolved
Make collision bulkhead watertight in way of missing plug IAW 46CFR179.310.
Due 20 October 2017
Resolved 19 October 2017
Resolution: Hole welded shut
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2017 Resolved
Provide updated navigational charts, light list, and coast pilot IAW 46CFR184.420.
Due 19 January 2017
Resolved 21 February 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 January 2017 Resolved
Provide updated FCC Safety Radiotelephony Certificate IAW 47CFR80.
Due 5 March 2017
Resolved 20 January 2017
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2017 Resolved
Remove dead end wiring in engine room and lazarette IAW 46CFR176.25-1.
Due 19 January 2017
Resolved 20 January 2017
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 5 January 2017 Resolved
Replace fuel hoses on generator with approved flex hose IAW 46CFR182.40-5.
Due 19 January 2017
Resolved 19 October 2017
Resolution: Hose satisfactorily replaced.
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 January 2017 Resolved
Repair hydraulic leaks on steering gear and throughout vessel, as discussed IAW 46CFR176.25-15.
Due 19 January 2017
Resolved 20 January 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 January 2017 Resolved
Replace hydraulic hoses on steering gear with approved flex hose and fittings IAW 46CFR182.40-5.
Due 19 January 2017
Resolved 6 April 2017
Resolution: Confirmed with CG-ENG that this hose is acceptable.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 January 2017 Resolved
Provide bonding wire for fuel fill IAW 46CFR182.20-30(d).
Due 19 January 2017
Resolved 20 January 2017
Resolution: This deficiency was issued in error due to a miscommunication regarding the contents of the tank.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 15 April 2009 Resolved
Install suitable exhaust lagging IWO MDE tubocharger exhaust discharges (port and STBD).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 28 April 2009
Resolution: Installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 February 2008 Resolved
Repair/replace missing light cover in fwd cabin space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 15 April 2009
Resolution: Corrected.
Lifesaving › Lifefloat › Netting
Issued 26 February 2008 Resolved
Repair/replace life float prior to getting under past the 3 miles from the boundary line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 15 April 2009
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 February 2008 Resolved
Renew/replace retro on two children’s life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 15 April 2009
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 February 2007 Resolved
Vessel failed to complete first annual exam as required by 46 CFR 176.100(a).
Action required: 705 - Other - as specified
Due 26 February 2007
Resolved 26 February 2007
Resolution: Completed satisfactory COI exam. LOW issued to Duke University Marine Lab, Lanier Mitchum
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 26 February 2007 Resolved
Provide proof of current first aid/CPR training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Current first aid/CPR card provided.
Communications › Audible Communications › Bell
Issued 26 February 2007 Resolved
Place on board proper sized bell.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Proper sized bell installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 February 2007 Resolved
Place on board current light list and tide tables.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Current light list and tide tables are now on board.
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 February 2007 Resolved
Replace retro-reflective tape on lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Retro-tape renewed on lifefloat.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 26 February 2007 Resolved
Renew stbd red gear morse control cable top bracket and clasp connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Stbd morse control cable top bracket and clasp connection renewed.
Engineering › Bilge Water Management System › Hose
Issued 26 February 2007 Resolved
Double clamp all vital system flexible hoses in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Double clamps installed on all vital systems in the engine room.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 26 February 2007 Resolved
Properly fasten/mount jacketwater pirping from keel coolers to main engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Jacketwater piping from keeler coolers properly mounted.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 February 2007 Resolved
Place on board current Certificate of Documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2007
Resolution: Current COD is now on board.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 26 February 2007 Resolved
Provide safety line for crewmember assisting in a man overboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 9 April 2007
Resolution: Safety line on board for crewmember to assist in a man overboard.
Engineering › Bilge Water Management System › Valve
Issued 7 December 2005 Resolved
Bilge overboard discharge missing valve in lazaret and engine room. Install valve IAW 46 CFR 179.350.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2006
Resolved 31 January 2006
Resolution: Check valves installed on overboard discharge piping in lazaret and engine room.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 7 December 2005 Resolved
Keel cooler piping system is required a shutoff valve IAW 46 CFR 182.422(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2006
Resolved 31 December 2005
Resolution: Shutoff valve (ball valve) installed on keel cooler piping system.
Stability › Watertight Integrity › General
Issued 7 December 2005 Resolved
Missing bottom weld on penetration through collision bulkhead. Collision bulkhead penetrations must be watertight IAW 46 CFR 179.310(a)(2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2006
Resolved 31 January 2006
Resolution: Bottom weld in place on penetration through collision bulkhead.
Lifesaving › Lifefloat › Markings
Issued 4 November 2004 Resolved
PROPERLY STENCIL AND RENEW RETROREFLECTIVE TAPE ON LIFE FLOAT.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2004
Resolution: RE-STENCILED VSL NAME AND REPLACED RETRO.
Construction/Loadline › Hull › Stiffener
Issued 24 February 2004 Resolved
REPLACE MISSING STIFFENER ON STBD SIDE CHINE.
Condition: Unknown
Due 1 March 2004
Resolved 3 May 2005
Fire Fighting › Fire Pumps › Power Source
Issued 24 February 2004 Resolved
REPLACE FAULTY FIRE PUMP CLUTCH AND TEST SAME.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 February 2004 Resolved
DOUBLE CLAMP PORT ENGINE FLEXIBLE EXHAUST CONNECTION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 3 May 2005
Construction/Loadline › Hull
Issued 21 February 2002 Resolved
Crop and renew two sections of bottom plate in rudder room approx 20"x7' each side of keel from stern forward. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2002
Navigation
Issued 16 April 2001 Resolved
MOVE STERN LIGHT SO THAT LIGHT IS VISIBLE FROM CLOSE ASTERN.
Condition: Unknown
Due 1 May 2001
Resolved 15 June 2001
Lifesaving
Issued 16 April 2001 Resolved
REPLACE HYDRO RELEASE ON THE 406 EPIRB. VESSEL LIMITED TO ONE MILE FROM LAND UNTIL REPLACED.
Condition: Unknown
Due 1 May 2001
Resolved 15 June 2001
Engineering
Issued 16 April 2001 Resolved
REPAIR WATER LEAK IN STBD MAIN ENGINE EXHAUST.
Condition: Unknown
Due 1 May 2001
Resolved 15 June 2001
Navigation
Issued 2 March 2000 Resolved
MAKE REPAIRS TO SINGLE SIDE BAND RADIO. VESSEL IS LIMITED TO TWENTY MILES OF COASTLINE UNTIL REPAIRS COMPLETED.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Lifesaving
Issued 10 March 1998 Resolved
REPLACE EXISTING FIRST AID KIT WITH ONE MEETING THE REQUIREMENTS OF 46 CFR 184.710
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Documentation
Issued 10 March 1998 Resolved
PROVIDE RECORD OF DRILLS AND RECORD OF MAINTENANCE OF FIREFIGHTING AND LIFESAVING EQUIPMENT.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1997 Resolved
REPAIR/REPLACE WIRE FRAME TO LIFEFLOAT WHERE SEPARATED, NO LATER THAN 10APR97.
Condition: Unknown
Due 10 March 1997
Resolved 10 March 1997
Documentation
Issued 10 March 1997 Resolved
PRIOR TO VESSEL OPERATING MORE THAN 1000 FT FROM SHORE, PROVIDE VALID RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 10 March 1997
Resolved 10 March 1997
Documentation
Issued 10 March 1997 Resolved
PROVIDE WASTE MANAGEMENT PLAN NO LATER THAN 10 APR 97.
Condition: Unknown
Due 10 March 1997
Resolved 10 March 1997
Lifesaving
Issued 7 May 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS MORE THAN ONE (1) MILE FROM LAND, PROVIDE ADEQUATE WEAK-LINL FOR (22) PERSON LIFE FLOAT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996 Resolved
PROVIDE ALTERNATE STOWAGE OF LIFE FLOAT TO ENSURE FLOAT-FREE OPERATION, NLT07 JUNE 1996.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996 Resolved
INSTALL GUARDS ON MAIN ENGINE BELT DRIVES NLT 07 JUNE 1996.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH MORE THAN (40) PERSONS, PROVIDE ADDITIONAL TYPE I PFD'S FOR ALL PERSONS ONBOARD.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Construction/Loadline
Issued 4 April 1996 Resolved
REPAIR FRACTURE IN LAZARETTE, 5TH FRAME AT STERN, IN WAY OF PORT SIDE DECK ANGLE BRACKET.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Construction/Loadline
Issued 4 April 1996 Resolved
REPAIR FRACTURE LOCATED ON STBD SIDE LAZARETTE, IN WAY OF 2ND FRAME BAY.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Lifesaving
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROPERLY STENCIL PFD STOWAGE TO INDICATE NUMBER/TYPE OF PFD'S (READILY VISIBLE).
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Fire Fighting
Issued 4 April 1996 Resolved
MAKE PERMANENT REPAIR TO FIRE MAIN WHERE TEMPORARY REPAIR EXISTS.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Engineering
Issued 4 April 1996 Resolved
REPOSITION VALVE FOR STBD M/E SEAWATER COOLING LINE.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Lifesaving
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS BEYOND (20)NM, PROVIDE EPIRB WITH CURRENT BATTERIES/HYDRO RELEASE.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Electrical
Issued 4 April 1996 Resolved
REPOSITION VALVE FOR SEAWATER COOLING INTAKE TO GENERATOR.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Lifesaving
Issued 4 April 1996 Resolved
STENCIL PADDLES FOR BUOYANT APPARATUS.
Condition: Unknown
Due 15 April 1996
Resolved 2 May 1996
Electrical
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, SECURE BATTERY BOXES.
Condition: Unknown
Due 4 April 1996
Resolved 2 May 1996
Electrical
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE APPROVED WIRING CONNECTIONS FORRULE PUMP IN AFT STEERING/FIRE PUMP IN ENGINE ROOM.
Condition: Unknown
Due 4 April 1996
Resolved 2 May 1996
Engineering
Issued 4 April 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE FLAME SCREEN FOR FUEL VENT.
Condition: Unknown
Due 4 April 1996
Resolved 2 May 1996
Lifesaving
Issued 14 March 1995 Resolved
REPLACE/REPAIR DETERIORATED LIFE FLOAT.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 14 March 1995 Resolved
PROVIDE THREE CHILDS PFDS TO REPLACE REJECTED UNITS, VESSEL IS RESTRICTED TO THE CARRIAGE OF TWO CHILDREN UNTIL SATISFIED._x001C_
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Fire Fighting
Issued 14 March 1995 Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHERS AS PER NFPA-10.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Construction/Loadline
Issued 5 April 1994 Resolved
REPLACE PLASTIC THRU HULL FITTING PORT SIDE STEERING COMPT WITH METALIC TYPE.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 5 April 1994 Resolved
RENEW WASTED B-II FIRE EXTINGUISHERS FOR ENGINE ROOM.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 5 April 1994 Resolved
MAKE BULKHEAD PENETRATION IN #2 VOID, PORT SIDE WATERTIGHT.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 5 April 1994 Resolved
PROVIDE HOSE AND CLAMP TO BE FITTED TO HAND BILGE PUMP SO FWD PEAKTANK CAN BE PUMPED OUT.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 12 April 1993 Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE ENGINE ROOM.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Deck/Cargo
Issued 12 April 1993 Resolved
REPAIR LEAKING HYDRAULIC LINE IN THE ENGINE ROOM FOR EQUIPMENT BOOM CONTROL.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Engineering
Issued 12 April 1993 Resolved
REPLACE FUEL TANK VENT FLAME SCREEN.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Navigation
Issued 31 March 1992 Resolved
PROVE PROPER OPERATION OF THE SSB ON 2182 MHZ. VESSEL MAY NOT OPERATE MORE THAN 20 MILES FROM LAND.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Navigation
Issued 31 March 1992 Resolved
PROVIDE APPROVED NAVIGATION STERN AND ANCHOR LIGHT. VESSEL MAY NOT OPERATE AT NIGHT OR DURING PERIODS OF REDUCED VISIBILITY.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Lifesaving
Issued 31 March 1992 Resolved
PROPERLY MOUNT LIFEFLOAT IN A FLOAT FREE CONDITION.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Lifesaving
Issued 19 April 1991 Resolved
PROVIDE TWO ADDTIONAL RING-BOUYS TO BE USE AS SUBSTITUDE PRIMARY LIFE- SAVING DUE TO LIFE-FLOAT BEING A 20 MAN FLOAT.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
PROVIDE TWO ADULT AND TWO CHILD-SIZE LIFE PRESERVERS, TO BRING TOTAL PRE- SERVERS TO 44 ADULT AND 5 CHILD-SIZE JACKETS.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
PROVIDE TWO PADDLES W/VESSEL'S NAME STENCILED AS PART OF THE LIFEFLOAT'S EQUIPMENT.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Electrical
Issued 19 April 1991 Resolved
PROVIDE TWO HAND HELD FLASHLIGHTS/LANTERNS AS EMERGENCY LIGHTING.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
PROVIDE A FLOAT-FREE LINK W/LINE FOR THE LIFEFLOAT AND ATTACH IT TO THE VSL
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 19 April 1991 Resolved
MAKE AVAILABLE TO THE LOCAL COAST GUARD INSPECTOR THE MASTER'S AND THE LIC-SENCED MATE'S LICENSES.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 19 April 1991 Resolved
OBTAIN VALID FCC SAFETY CERTIFICATE AND STATION LICENSE.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
PROVIDE A WATERLIGHT FOR THE REQUIRED RING-BOUY.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Fire Fighting
Issued 19 April 1991 Resolved
PROVIDE AND MOUNT TWO B-II PORTABLE FIRE EXTINGUISHERS IN THE ENGINEROOM.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 19 April 1991 Resolved
POST IN THE PASSENGER CARRING COMPARTMENT A SAFETY INSTRUCTION PASENGER CHECK-OFF LIST.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.