← All vessels
SUSAN HUDSON
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named SUSAN HUDSON
SUSAN HUDSON is a 1991 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1991, most recently in July 2026, along with 104 deficiencies and 1 operational control.
Records from 1991 to 2026. Most recent: inspection, 27 July 2026.
- Built
- 1991
- Last inspected
- 27 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 104 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
973891
WDI2503
360762
Flag
UNITED STATES
367678840
Maury page id
psix-360762
Inspections, by type
…with no type recorded10
Years with a record
29 calendar years (1991–2026)
The 66 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 37 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUSTOM DESIGN SERVICES · FULTON, TX, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
37 - Simplified, Gross Ton
37 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP7993MMSI 367678840 · active · compulsorily equipped · granted 7 September 2024, expires 7 September 2034
WDI2503MMSI 367678840 · cancelled · compulsorily equipped · granted 16 June 2015, cancelled 9 May 2024
WAV3642MMSI 367117050 · expired · voluntarily equipped · granted 26 May 2006, cancelled 6 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 66
27 July 2026
Type not recorded
No type recorded · USCGC LAWRENCE O. LAWSON (WPC 1120) · USCG East District (CGD-E) · Activity 8449779
29 October 2025
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8259445
7 May 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8130938
5 March 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8088786
21 January 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8066700
6 March 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7874901
14 December 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7838697
16 August 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769624
12 April 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7667853
3 November 2022
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7587954
28 October 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7339523
27 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7321499
20 October 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7080965
22 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6839335
27 September 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6822797
9 April 2019
Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659003
19 October 2017
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6290134
5 October 2017
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6280270
5 January 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065968
19 November 2015
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5766929
2 August 2014
Hull Examination · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5143335
15 December 2009
Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3650554
28 April 2009
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3465191
15 April 2009
Annual Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3452914
26 February 2008
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3156411
19 November 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3104693
9 April 2007
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2904591
26 February 2007
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2877674
7 December 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2547713
1 March 2005
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2300897
4 November 2004
Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2234546
24 February 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2012144
7 November 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1945014
8 November 2002
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702646
21 February 2002
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1488021
8 November 2001
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075697
16 April 2001
Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1471247
5 October 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 102216
10 March 2000
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418674
2 March 2000
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1436336
21 October 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 23164
14 October 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 139569
9 March 1999
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1381493
16 February 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1390940
27 March 1998
Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 787733
10 March 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121410
16 January 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1111444
8 April 1997
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1106865
10 March 1997
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1105412
14 May 1996
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1084312
7 May 1996
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082458
15 April 1996
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1081101
4 April 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1081103
28 November 1995
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 880918
20 April 1995
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1340529
14 March 1995
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 827372
5 April 1994
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1166561
12 January 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1164194
13 October 1993
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1148152
12 April 1993
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 838085
19 October 1992
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 937229
7 April 1992
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1256264
31 March 1992
Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258985
4 November 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1252192
11 June 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1017188
19 April 1991
Initial Certification · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1230309
Deficiency record · 104
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2025
Resolved
Short lengths of approved non metallic flexible hose, fixed by two hose clamps at each end of the hose, may be used at machinery connections for a keel cooler installation. MI observed starboard main engine keel cooler hose damaged resulting in slight drip of coolant in space. Replace hose to the satisfaction of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2025
Resolved
The owner shall ensure vessel is equipped with a vessel master key control system. Vessel must have list of all crew (identified by position) allowed to access key and kept in a logbook with dates/times, rooms, and name/rank of crew member when crew utilizes master key (can be electronic, must be readily available).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022
Resolved
The cooling water strainer on the vessel's generator was zip-tied in place. Make appropriate permanent repairs ensuring that the strainer is secured. 46 CFR 182.10-1 (Old T)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 October 2020
Resolved
A separate circuit, fused at the main distribution panel
shall be provided for each radio-phone installation.
Provide separate over current protection for each VHF
radio installation. - 46 CFR 183.05-25(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2020
Resolved
Switches other than those mounted on the switchboard
shall be of the enclosed type. Radio amplifier installed
in wheelhouse had a circuit breaker hanging in the
overhead creating a hazard. Amplifier was also not
subject to plan review/approval process. Remove audio
amplifier, circuit breaker and associated wiring. - 46 CFR 183.05-15(d)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 October 2020
Resolved
Life floats need to be stowed in such a manner as to
enable crew members to manually launch in an emergency.
The current length of line attaching the top life float
to the bottom life float does not allow a crew member to
lower the top life float to the point of embarkation
without also having to move the second life float along
with it. - 46 CFR 180.130(a)(7)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2020
Resolved
Emergency escape hatch is not labeled on the outside.
Label hatch in clearly legible letters at least 2 inches
high "EMERGENCY EXIT, KEEP CLEAR". - 46 CFR 185.606
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2019
Resolved
Install positive shutoff valve at the hull penetration for the submersible bilge pump in the lazarrette. 46CFR182.520(f)
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 October 2019
Resolved
Grind cracks found on the circular insert located in the forepeak. Make available for inspection, due December 15th, 2019. 46CFR176.700(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2019
Resolved
Remove cooler or install waterproof GFCI outlet to service cooler. Cap penetration in bulkhead. 46CFR183.10-20(a)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 September 2019
Resolved
Provide spacers between life floats. - 46 CFR 180.137(f)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 April 2019
Resolved
Install life float. Passenger count limited to 22 persons until new life float provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 April 2019
Resolved
Remove and replace #2 bilge alarm light bulb.
Engineering › Bilge Water Management System › Not Operational
Issued 23 April 2018
Resolved
07126 Remove excessive oil from engine room bilge prior to carrying passengers. 46 CFR 182.100. 701 c.
Engineering › Reduction Gearing/Clutches › Hose
Issued 23 April 2018
Resolved
09210 Replace hose on port reduction gear that is leaking. Find and repair oil leaks on both diesel engines by May 7, 2018. 46 CFR 182.100 16c.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 October 2017
Resolved
PWG 01 Prove Proper operation of #3 Bilge High Water Level Alarm. 46 CFR 182.530
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 19 October 2017
Resolved
PWG 02 Replace/reinstall engine mount bolts underneath reduction gear port engine. 46CFR 176.804
Engineering › Fuel Oil Service System › Suction Strainer
Issued 19 October 2017
Resolved
PWG 03 Place metallic plug on bottom of starboard fuel strainer
Construction/Loadline › Structures › Manhole
Issued 19 October 2017
Resolved
PWG 04 Place metallic securing cable on forepeak watertight hatch. 46CFR"Old S" 171.124(b)
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 19 October 2017
Resolved
PWG 05 Have all Captains obtain Marine Operators Permit from FCC before operating outside 20nm. 47 CFR 80.155
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 October 2017
Resolved
PWG 06 Be able to conduct post casualty alchol testing with in 2 hours. Alcohol test strip are expired. 46 CFR 16.240
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 October 2017
Resolved
PWG 07 - Log all Fire and Abandon Ship Drills. 46 CFR 185.530
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2017
Resolved
PWG 08 - Log monthly, quarterly, and annual lifesaving equipment inspections. 46 CFR 185.726(d)
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2017
Resolved
PWG 09 - Log monthly EPIRB Checks. 46 CFR 185.728
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 October 2017
Resolved
Waterlines penetrate the collision that are incable of being made watertight. Add valves immediately aft of collision bulke head on waterlines. 46 CFR "Old S" 171.090(g)(3)(ii)
Engineering › Bilge Water Management System › Pump
Issued 5 January 2017
Resolved
Prove proper operation of fixed power bilge pumps. Engine driven bilge pump could not get suction from the E/R bilge. Rule pumps on board do not meet UL1113 standard. IAW 46CFR182.25-10(d).
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 January 2017
Resolved
Provide approval documention for vessel marine sanitation device.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2017
Resolved
Make collision bulkhead watertight in way of missing plug IAW 46CFR179.310.
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2017
Resolved
Provide updated navigational charts, light list, and coast pilot IAW 46CFR184.420.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 January 2017
Resolved
Provide updated FCC Safety Radiotelephony Certificate IAW 47CFR80.
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2017
Resolved
Remove dead end wiring in engine room and lazarette IAW 46CFR176.25-1.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 5 January 2017
Resolved
Replace fuel hoses on generator with approved flex hose IAW 46CFR182.40-5.
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 January 2017
Resolved
Repair hydraulic leaks on steering gear and throughout vessel, as discussed IAW 46CFR176.25-15.
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 January 2017
Resolved
Replace hydraulic hoses on steering gear with approved flex hose and fittings IAW 46CFR182.40-5.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 January 2017
Resolved
Provide bonding wire for fuel fill IAW 46CFR182.20-30(d).
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 15 April 2009
Resolved
Install suitable exhaust lagging IWO MDE tubocharger exhaust discharges (port and STBD).
Electrical › Lighting (service) › Lighting Fixture
Issued 26 February 2008
Resolved
Repair/replace missing light cover in fwd cabin space.
Lifesaving › Lifefloat › Netting
Issued 26 February 2008
Resolved
Repair/replace life float prior to getting under past the 3 miles from the boundary line.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 February 2008
Resolved
Renew/replace retro on two children’s life jackets
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 February 2007
Resolved
Vessel failed to complete first annual exam as required by 46 CFR 176.100(a).
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 26 February 2007
Resolved
Provide proof of current first aid/CPR training.
Communications › Audible Communications › Bell
Issued 26 February 2007
Resolved
Place on board proper sized bell.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 February 2007
Resolved
Place on board current light list and tide tables.
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 February 2007
Resolved
Replace retro-reflective tape on lifefloat.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 26 February 2007
Resolved
Renew stbd red gear morse control cable top bracket and clasp connection.
Engineering › Bilge Water Management System › Hose
Issued 26 February 2007
Resolved
Double clamp all vital system flexible hoses in the engine room.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 26 February 2007
Resolved
Properly fasten/mount jacketwater pirping from keel coolers to main engines.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 February 2007
Resolved
Place on board current Certificate of Documentation.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 26 February 2007
Resolved
Provide safety line for crewmember assisting in a man overboard.
Engineering › Bilge Water Management System › Valve
Issued 7 December 2005
Resolved
Bilge overboard discharge missing valve in lazaret and engine room. Install valve IAW 46 CFR 179.350.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 7 December 2005
Resolved
Keel cooler piping system is required a shutoff valve IAW 46 CFR 182.422(b).
Stability › Watertight Integrity › General
Issued 7 December 2005
Resolved
Missing bottom weld on penetration through collision bulkhead. Collision bulkhead penetrations must be watertight IAW 46 CFR 179.310(a)(2).
Lifesaving › Lifefloat › Markings
Issued 4 November 2004
Resolved
PROPERLY STENCIL AND RENEW RETROREFLECTIVE TAPE ON LIFE FLOAT.
Construction/Loadline › Hull › Stiffener
Issued 24 February 2004
Resolved
REPLACE MISSING STIFFENER ON STBD SIDE CHINE.
Fire Fighting › Fire Pumps › Power Source
Issued 24 February 2004
Resolved
REPLACE FAULTY FIRE PUMP CLUTCH AND TEST SAME.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 February 2004
Resolved
DOUBLE CLAMP PORT ENGINE FLEXIBLE EXHAUST CONNECTION.
Construction/Loadline › Hull
Issued 21 February 2002
Resolved
Crop and renew two sections of bottom plate in rudder room approx 20"x7' each side of keel from stern forward. LEGACY COMPONENT DESC: Bottom Plating
Navigation
Issued 16 April 2001
Resolved
MOVE STERN LIGHT SO THAT LIGHT IS VISIBLE FROM CLOSE ASTERN.
Lifesaving
Issued 16 April 2001
Resolved
REPLACE HYDRO RELEASE ON THE 406 EPIRB. VESSEL LIMITED TO ONE MILE FROM LAND UNTIL REPLACED.
Engineering
Issued 16 April 2001
Resolved
REPAIR WATER LEAK IN STBD MAIN ENGINE EXHAUST.
Navigation
Issued 2 March 2000
Resolved
MAKE REPAIRS TO SINGLE SIDE BAND RADIO. VESSEL IS LIMITED TO TWENTY MILES OF COASTLINE UNTIL REPAIRS COMPLETED.
Lifesaving
Issued 10 March 1998
Resolved
REPLACE EXISTING FIRST AID KIT WITH ONE MEETING THE REQUIREMENTS OF 46 CFR 184.710
Documentation
Issued 10 March 1998
Resolved
PROVIDE RECORD OF DRILLS AND RECORD OF MAINTENANCE OF FIREFIGHTING AND LIFESAVING EQUIPMENT.
Lifesaving
Issued 10 March 1997
Resolved
REPAIR/REPLACE WIRE FRAME TO LIFEFLOAT WHERE SEPARATED, NO LATER THAN 10APR97.
Documentation
Issued 10 March 1997
Resolved
PRIOR TO VESSEL OPERATING MORE THAN 1000 FT FROM SHORE, PROVIDE VALID RADIOTELEPHONY CERTIFICATE.
Documentation
Issued 10 March 1997
Resolved
PROVIDE WASTE MANAGEMENT PLAN NO LATER THAN 10 APR 97.
Lifesaving
Issued 7 May 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS MORE THAN ONE (1) MILE FROM LAND, PROVIDE ADEQUATE WEAK-LINL FOR (22) PERSON LIFE FLOAT.
Lifesaving
Issued 7 May 1996
Resolved
PROVIDE ALTERNATE STOWAGE OF LIFE FLOAT TO ENSURE FLOAT-FREE OPERATION, NLT07 JUNE 1996.
Engineering
Issued 7 May 1996
Resolved
INSTALL GUARDS ON MAIN ENGINE BELT DRIVES NLT 07 JUNE 1996.
Lifesaving
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH MORE THAN (40) PERSONS, PROVIDE ADDITIONAL TYPE I PFD'S FOR ALL PERSONS ONBOARD.
Construction/Loadline
Issued 4 April 1996
Resolved
REPAIR FRACTURE IN LAZARETTE, 5TH FRAME AT STERN, IN WAY OF PORT SIDE DECK ANGLE BRACKET.
Construction/Loadline
Issued 4 April 1996
Resolved
REPAIR FRACTURE LOCATED ON STBD SIDE LAZARETTE, IN WAY OF 2ND FRAME BAY.
Lifesaving
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROPERLY STENCIL PFD STOWAGE TO INDICATE NUMBER/TYPE OF PFD'S (READILY VISIBLE).
Fire Fighting
Issued 4 April 1996
Resolved
MAKE PERMANENT REPAIR TO FIRE MAIN WHERE TEMPORARY REPAIR EXISTS.
Engineering
Issued 4 April 1996
Resolved
REPOSITION VALVE FOR STBD M/E SEAWATER COOLING LINE.
Lifesaving
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS BEYOND (20)NM, PROVIDE EPIRB WITH CURRENT BATTERIES/HYDRO RELEASE.
Electrical
Issued 4 April 1996
Resolved
REPOSITION VALVE FOR SEAWATER COOLING INTAKE TO GENERATOR.
Lifesaving
Issued 4 April 1996
Resolved
STENCIL PADDLES FOR BUOYANT APPARATUS.
Electrical
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, SECURE BATTERY BOXES.
Electrical
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE APPROVED WIRING CONNECTIONS FORRULE PUMP IN AFT STEERING/FIRE PUMP IN ENGINE ROOM.
Engineering
Issued 4 April 1996
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE FLAME SCREEN FOR FUEL VENT.
Lifesaving
Issued 14 March 1995
Resolved
REPLACE/REPAIR DETERIORATED LIFE FLOAT.
Lifesaving
Issued 14 March 1995
Resolved
PROVIDE THREE CHILDS PFDS TO REPLACE REJECTED UNITS, VESSEL IS RESTRICTED TO THE CARRIAGE OF TWO CHILDREN UNTIL SATISFIED._x001C_
Fire Fighting
Issued 14 March 1995
Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHERS AS PER NFPA-10.
Construction/Loadline
Issued 5 April 1994
Resolved
REPLACE PLASTIC THRU HULL FITTING PORT SIDE STEERING COMPT WITH METALIC TYPE.
Fire Fighting
Issued 5 April 1994
Resolved
RENEW WASTED B-II FIRE EXTINGUISHERS FOR ENGINE ROOM.
Construction/Loadline
Issued 5 April 1994
Resolved
MAKE BULKHEAD PENETRATION IN #2 VOID, PORT SIDE WATERTIGHT.
Construction/Loadline
Issued 5 April 1994
Resolved
PROVIDE HOSE AND CLAMP TO BE FITTED TO HAND BILGE PUMP SO FWD PEAKTANK CAN BE PUMPED OUT.
Fire Fighting
Issued 12 April 1993
Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE ENGINE ROOM.
Deck/Cargo
Issued 12 April 1993
Resolved
REPAIR LEAKING HYDRAULIC LINE IN THE ENGINE ROOM FOR EQUIPMENT BOOM CONTROL.
Engineering
Issued 12 April 1993
Resolved
REPLACE FUEL TANK VENT FLAME SCREEN.
Navigation
Issued 31 March 1992
Resolved
PROVE PROPER OPERATION OF THE SSB ON 2182 MHZ. VESSEL MAY NOT OPERATE MORE THAN 20 MILES FROM LAND.
Navigation
Issued 31 March 1992
Resolved
PROVIDE APPROVED NAVIGATION STERN AND ANCHOR LIGHT. VESSEL MAY NOT OPERATE AT NIGHT OR DURING PERIODS OF REDUCED VISIBILITY.
Lifesaving
Issued 31 March 1992
Resolved
PROPERLY MOUNT LIFEFLOAT IN A FLOAT FREE CONDITION.
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE TWO ADDTIONAL RING-BOUYS TO BE USE AS SUBSTITUDE PRIMARY LIFE- SAVING DUE TO LIFE-FLOAT BEING A 20 MAN FLOAT.
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE TWO ADULT AND TWO CHILD-SIZE LIFE PRESERVERS, TO BRING TOTAL PRE- SERVERS TO 44 ADULT AND 5 CHILD-SIZE JACKETS.
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE TWO PADDLES W/VESSEL'S NAME STENCILED AS PART OF THE LIFEFLOAT'S EQUIPMENT.
Electrical
Issued 19 April 1991
Resolved
PROVIDE TWO HAND HELD FLASHLIGHTS/LANTERNS AS EMERGENCY LIGHTING.
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE A FLOAT-FREE LINK W/LINE FOR THE LIFEFLOAT AND ATTACH IT TO THE VSL
Documentation
Issued 19 April 1991
Resolved
MAKE AVAILABLE TO THE LOCAL COAST GUARD INSPECTOR THE MASTER'S AND THE LIC-SENCED MATE'S LICENSES.
Documentation
Issued 19 April 1991
Resolved
OBTAIN VALID FCC SAFETY CERTIFICATE AND STATION LICENSE.
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE A WATERLIGHT FOR THE REQUIRED RING-BOUY.
Fire Fighting
Issued 19 April 1991
Resolved
PROVIDE AND MOUNT TWO B-II PORTABLE FIRE EXTINGUISHERS IN THE ENGINEROOM.
Documentation
Issued 19 April 1991
Resolved
POST IN THE PASSENGER CARRING COMPARTMENT A SAFETY INSTRUCTION PASENGER CHECK-OFF LIST.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.