JO ASPEN is a 1991 tank ship. The Coast Guard has recorded 78 inspections since 1991, most recently in January 2010, along with 51 deficiencies — 1 with no resolution recorded — and 13 operational controls.

Records from 1991 to 2010. Most recent: inspection, 6 January 2010.

Built
1991
Last inspected
6 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8900294 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
360922
Flag
NORWAY
—
Maury page id
psix-360922

Inspections, by type

…with no type recorded45
…past their stated due date1
Years with a record 19 calendar years (1991–2010)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12637 - Dead Weight, Ton
17020 - Displacement, Ton
7922 - Simplified, Gross Ton
7984 - Convention (Subpart B), Gross Ton
4131 - Convention (Subpart B), Net Ton
4031 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 78

6 January 2010 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3659473
30 December 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3656919
25 December 2009 PII Safety Exam · ISPS II Exam · COC-TVE Renew · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3655225
25 December 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3655283
22 December 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3654260
29 March 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3442112
2 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3426657
27 February 2009 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3425296
21 February 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3413724
13 November 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362023
12 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362129
11 November 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3361053
27 October 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3351989
19 October 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3352370
8 October 2008 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3342310
21 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3274674
15 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3116148
12 December 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3114051
19 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3100818
13 November 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097744
13 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097859
7 November 2007 PII Safety Exam · MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3094440
10 April 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2907053
25 March 2007 MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2894349
5 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2882338
30 October 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2810662
19 October 2006 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2804156
17 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2716391
4 December 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2545580
26 September 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2501100
26 September 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2501653
24 September 2005 MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2497852
14 October 2004 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2223865
10 September 2003 MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1901645
4 September 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1896810
20 August 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1881614
20 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293927
20 April 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 289370
10 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281993
10 September 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1053648
27 December 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 436158
12 December 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1467172
13 October 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433670
13 October 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433776
28 May 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 73947
7 October 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 420924
7 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 802315
7 May 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 336
9 January 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411702
28 October 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409375
10 February 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400447
10 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398275
8 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399603
17 September 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 441787
17 September 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1134088
1 April 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389694
28 March 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 454825
5 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383432
28 October 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 371852
2 September 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400074
25 August 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 865366
14 August 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 369368
14 August 1994 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1174447
17 September 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 360910
31 March 1993 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147221
3 February 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963128
28 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355894
18 November 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 488452
5 November 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1134327
26 May 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 351245
26 May 1992 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1256118
14 January 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 348231
21 November 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 676467
28 October 1991 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1249280
26 October 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 458444
22 October 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 442240
29 March 1991 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 342866
29 March 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253599

Deficiency record · 51

Navigation › Collision/Grounding Avoidance › Radar
Issued 30 December 2009 Resolved
Received and granted inbound deviation request for inoperable primary radar. Vessel must submit technician report attesting to the proper operable condition of x-band radar prior to departure from the Port of Houston.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2009
Resolved 6 January 2010
Resolution: Received technician report attesting to the proper operation of the primary radar.
Construction/Loadline › Structures › Superstructure
Issued 25 December 2009 Resolved
Deck railing on stbdside adjacent to cargo hold 7S is detached. The missing railing creates a hazard where someone or something could fall off of the vessel during inclement conditions. Deck railing on port adjacent to 3P cargo tank missing a section. The two hazards were communicated to [name withheld] railing to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2010
Resolution: Rec''d report from certificate issuing authority attesting to the railing adajacent to Cargo Tank 4P as replaced and rewelded.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 25 December 2009 Resolved
Audible alarm heard on vessel where cargo transfer is controlled is present. Alarm for overfill protection inaudible from cargo deck area. Vsl is to maintain a watchstander in cargo control room per SMS. Repair alarm to the satisfaction of class prior to next port.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 December 2009
Resolution: Deficiency resolved on the spot. Attending PSCO heard and saw alarm from cargo deck area.
Deck/Cargo › Ballast › Piping
Issued 25 December 2009 No resolution recorded
Fixed sounding for 6S ballast tank is inoperable. Line in way of on deck gauge is detached. [name withheld] was informed to monitor condition of tank. Repair fixed sounding to the satisfaction of class.
Action required: 705 - Other - as specified
Due 25 January 2010 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-electric) › Cylinder Head
Issued 2 March 2009 Resolved
One exhaust valve of main engine cylinder was stuck.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Tech report submitted attesting to replacement of the cylinder head.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 November 2008 Resolved
12NOV08: Vessel experienced a Power Irregularity due to exhaust leaks on the portside M/E.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2008
Resolved 13 November 2008
Resolution: Received a class report from DNV stating that the exhaust system on the portside M/E was repaired and tested with satisfactory results.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 8 October 2008 Resolved
Diesel generator #1 inoperable due to a faulty circuit breaker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2008
Resolution: DNV Class surveyor cleared deficiency. Circuit breaker was repaired and 2 required generator sets running satisfactory. See "Class Report" attached in documents.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 8 October 2008 Resolved
Vessel's controllable pitch propeller system leaking approzimately 20 gallons of lube oil per day.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2008
Resolution: Vessel hired diver to check controllable pitch propeller for leak. There was no leak found. See "Dive Report" attached in documents.
Electrical › Electric Generation Source (service) › Generator
Issued 8 October 2008 Resolved
This is a Condition of Class. The ship's #1 and #2 shaft generators are OOC. The ship has 2 diesel generators that provides main source of power and have been tested satisfactory. Vessel met minimum requirements for 2 independent operating generators. See "Class Report" attached in documents.
Action required: 705 - Other - as specified
Due 12 February 2009
Resolved 27 October 2008
Resolution: Received proper documentation from Det Norske Veritas rectifying the deficiency.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 8 October 2008 Resolved
This is a Condition of Class. CPP system to be monitored during voyage to next port of call and any loss of oil to be reported to DNV.
Action required: 705 - Other - as specified
Due 30 October 2008
Resolved 27 October 2008
Resolution: Received proper documentation from Det Norske Veritas rectifying the deficiency.
Lifesaving › Lifeboat › Hull
Issued 7 November 2007 Resolved
During Abandon Ship Drill, the Starboard lifeboat hit the Davit Arms causing numerous scrapes and insets to the boat's hull. Prior to departure from the Port of NY/NJ make permanent repairs to the lifeboat, launch and recover lifeboat in the presence of class, and have class inspect the falls to ensure the lifeboat will be ready for immediate use in case of emergency. See narrative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2007
Resolution: Received Class report from DNV stating that permanent repairs are to be completed by 22NOV2007 or prior to leaving next port of call.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 November 2007 Resolved
Several fittings on the vessel's Explosion Proof Lighting Fixtures in the Cargo Area are deteriorated. Replace fittings IWO lighting fixtures.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 8 November 2007
Resolution: Class verified replacement of fittings.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 7 November 2007 Resolved
The casing for the High Level Alarm on the #7P Cargo Tank is holed & wasted. Replace casing.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2007
Resolved 13 November 2007
Resolution: Cleared by class (DNV) report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 October 2006 Resolved
Provide Draeger Tubes for Hexane Cargo at next U.S. Port
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: Received class report from Det Norkse Veritas satisfying requirement.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 October 2006 Resolved
Provide Draeger Tubes for Olifin Cargoes at next U.S. Port
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: Received class report from Det Norkse Veritas satisfying requirement.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 October 2006 Resolved
Provide Calibration gas of 50 PPM CO at next US port.
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: Received class report from Det Norkse Veritas satisfying requirement.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 October 2006 Resolved
Provide calibration gas for 8% by volume Butane at next US port.
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: Received class report from Det Norkse Veritas satisfying requirement.
Electrical › Electric Generation Source (service) › Generator
Issued 17 July 2006 Resolved
Vessel shall provide class report attesting to satisfactory repair or replacment of both auxilary generators.
Condition: Unknown
Due 31 October 2006
Resolved 21 October 2006
Resolution: Classification attested to installation of temporary generator set. Generator to be repaired upon return to Sweden.
Engineering › Steam Boiler (propulsion) › Gauge Glass
Issued 24 September 2005 Resolved
Renew boiler burner gauges prior to their use.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 26 September 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 September 2005 Resolved
Make repairs to 3 port deep valve. Until corrected, cargo operation in 3 port are prohibited.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 26 September 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 September 2005 Resolved
Make proper repairs to port side stripping line to the satisfaction of class.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 4 December 2005
Resolution: Received class report from DNV satisfying requirement.
Construction/Loadline › Markings › Load Line Mark
Issued 24 September 2005 Resolved
Freshen load line and draft marks.
Action required: 15 - Rectify deficiencies by next port
Resolved 4 December 2005
Resolution: Received proper documentation from Master satisfying requirement.
Lifesaving › Lifeboat › Markings
Issued 24 September 2005 Resolved
Renew retro reflective tape on the starboard lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2005
Lifesaving › Launching Appliances › Davit
Issued 24 September 2005 Resolved
Free frozen davit (starboard lifeboat) wheels and make repairs to port and starboard lifeboat limit switch.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 4 December 2005
Resolution: Received class report from DNV satisfying requirement.
Fire Fighting › Fire Hoses › Number
Issued 24 September 2005 Resolved
Provide adequate number of fire hoses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2005
Deck/Cargo › Holds/Tanks
Issued 20 August 2003 Resolved
Tank over fill and high level alarms located on main deck, not operational alarms and indicator operated at main control pannel. Repair to the satidfaction of Class. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 4 September 2003
Resolution: Recieved class report fron DNV statisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 August 2003 Resolved
Expansion joint located above cargo tank entrance 7c deformed. Replace as original. Repair to the satisfaction Class. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 20 September 2003
Resolved 4 September 2003
Resolution: Recieved class report fron DNV statisfying requirement.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 20 August 2003 Resolved
Fax receipt for smoke/light missing from bridge wing.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 20 August 2003
Resolution: Receipt fax to Coast Guard Activities Baltimore.
Fire Fighting › Miscellaneous Items
Issued 20 August 2003 Resolved
Update Fire Control plan to reflect proper symbols for EEBDs. To the satisfaction of Class.
Action required: 705 - Other - as specified
Due 20 September 2003
Resolved 4 September 2003
Resolution: Recieved class report fron DNV statisfying requirement.
Construction/Loadline
Issued 10 September 2000 Resolved
INOPERABLE PUMP TO OILY WATER SEPERATOR.
Condition: Unknown
Due 21 November 2000
Resolved 21 November 2000
Deck/Cargo
Issued 28 October 1997 Resolved
Demonstrate proper operation of high level alarms, both visual and audible,on the open deck._x001C_ _x001C_ 46 CFR 153.409
Condition: Unknown
Due 8 November 1997
Resolved 29 October 1997
Deck/Cargo
Issued 28 October 1997 Resolved
Demonstrate proper operation of overflow alarm, both visual and audible, onthe open deck._x001C_ _x001C_ 46 CFR 153.408
Condition: Unknown
Due 8 November 1997
Resolved 29 October 1997
Deck/Cargo
Issued 25 August 1994 Resolved
PRIOR TO USING THE VCS, PROVIDE LOCAL COAST GUARD WITH DOCUMENTATION OF PERSONNEL TRAINING ON VAPOR COLLECTION SYSTEM AS PER 46 CFR 39.10-11.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Fire Fighting
Issued 25 August 1994 Resolved
PRIOR TO LOADING ANY CARGOES REQUIRING POLAR SOLVENT FOAM AS PER 46 CFR 153, DEMONSTRATE APPROPRIATE FOAM ON BOARD.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Deck/Cargo
Issued 25 August 1994 Resolved
PRIOR TO LOADING CARGOES THAT REQUIRE VAPOR COLLECTION SYSTEM, DEMONSTRATE HIGH AND LOW VAPOR PRESSURE ALARMS AS PER 46 CFR 39.20-13.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Deck/Cargo
Issued 25 August 1994 Resolved
PRIOR TO LOADING CARGOES THAT REQUIRE OVERFLOW ALARM, INSTALL AN AUDIBLE ALARM ON DECK THAT IS INDEPENDENT OF THE HIGH LEVEL ALARM SYSTEM AS PER 46 CFR 153.408(g).
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Documentation
Issued 14 August 1994 Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE REVISED IMO CERTIFICATE OF FITNESS DOCUMENTATION FOR REISSUANCE OF SUBCHAPTER O ENDORSEMENT TO THE USCG MARINE SAFETY CENTER. **SPECIAL INSTRUCTION** AT NEXT U.S. PORT CONTACT THE COGNIZANT OCMI FOR ISSUANCE OF SUBCHAPTER O ENDORSEMENT.
Condition: Unknown
Due 14 September 1994
Resolved 8 September 1994
Documentation
Issued 14 August 1994 Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE DOCUMENTATION ON BOARD SHOWING JO ASPEN SHIPPING LTD AS THE LEGAL OPERATOR AND FINANCIALLY RESPOSIBLE PER 33CFR130. *SPECIAL INSTR* IF OPERATOR IS CHANGED TO ANY CO. OTHER THAN THAT NOTED, RENEWAL OF COFR MUST BE MADE PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 14 September 1994
Resolved 8 September 1994
Deck/Cargo
Issued 14 August 1994 Resolved
NO CARGO TO BE LOADED INTO CARGO TANK 3 PORT IN U.S. WATERS UNTIL HIGH LEVEL ALARM HAS BEEN REPAIRED AND DEMONSTRATED TO COGNIZANT OCMI. 46CFR153.409
Condition: Unknown
Due 14 August 1994
Resolved 14 August 1994
Lifesaving
Issued 14 August 1994 Resolved
PROVIDE WEAK-LINKS FOR THE PORT AND STARBOARD 25 PERSON INFLATABLE LIFERAFTS. SOLAS 74 (AS AMENDED) CHAPTER III, REGULATION 29.
Condition: Unknown
Due 14 September 1994
Resolved 8 September 1994
Fire Fighting
Issued 14 August 1994 Resolved
PROVIDE 4 BOLTS, 4 NUTS AND 8 WASHERS FOR THE VESSEL'S INTERNATIONAL SHORE CONNECTION. SOLAS 74 (AS AMENDED), CHAPTER II-2, REGULATION 19.
Condition: Unknown
Due 14 September 1994
Resolved 8 September 1994
Accommodation/Occupational Safety
Issued 14 August 1994 Resolved
REPAIR ALL HYDRAULIC LEAKS IN FORECASTLE AND WIPE OIL OFF THE DECK. ILO 147.ART.3.
Condition: Unknown
Due 14 September 1994
Resolved 8 September 1994
Deck/Cargo
Issued 14 August 1994 Resolved
PRIOR TO NEXT U.S. PORT VISIT, INSTALL THE REQUIRED ON DECK AUDIBLE HIGH LEVEL ALARM. 46CFR153.409
Condition: Unknown
Due 14 August 1994
Resolved 14 August 1994
Fire Fighting
Issued 26 May 1992 Resolved
PROVIDE PROPER RACKS FOR N2 CYLINDERS
Condition: Unknown
Due 26 May 1992
Resolved 26 May 1992
Fire Fighting
Issued 26 May 1992 Resolved
DOCUMENT RECENT TESTING OF FAOM AND FIXED CO2 SYSTEM.
Condition: Unknown
Due 26 May 1992
Resolved 26 May 1992
Lifesaving
Issued 26 May 1992 Resolved
PROVIDE ADEQUATE SIGNS FOR EYEWASH - MANIFOLD AREA.
Condition: Unknown
Due 26 May 1992
Resolved 26 May 1992
Lifesaving
Issued 26 May 1992 Resolved
REPAIR STAIRTOWER DOORS.
Condition: Unknown
Due 26 May 1992
Resolved 26 May 1992
Documentation
Issued 29 March 1991 Resolved
PROVIDE COPIES OF US CFR PT. 40 AND 140-155.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Deck/Cargo
Issued 29 March 1991 Resolved
PROVE PROPER OPERATION OF IGS SYSTEM PRIOR TO CARRYING CARGOES THAT REQUIREINERTING.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Fire Fighting
Issued 29 March 1991 Resolved
LABEL ALL FIRE STATIONS.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Deck/Cargo
Issued 29 March 1991 Resolved
REPLACE ALL FUEL OIL VENT FLAME SCREENS.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991

Ownership record