MAURY USCG vessel records
← All vessels

DEMOLEN

Built
Not recorded
Last inspected
25 June 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 25 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2001–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
356 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-36100
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

25 June 2026 Excursion Permit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8413609
30 April 2026 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8358520
17 September 2025 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8235883
16 June 2025 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8160239
22 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8116800
8 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7976780
1 December 2023 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7832243
17 November 2023 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7826483
31 July 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7767885
1 August 2022 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7522107
20 May 2021 Initial Certification · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7506592
6 February 2012 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4239832
5 September 2001 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 45974

Deficiency record · 20

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 September 2025 Resolved
Each towing vessel operating on oceans, coastwise, limited coastwise, or beyond 3 nautical miles from shore upon the Great Lakes must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon (EPIRB) that meets the requirements of 47 CFR part 80. EPRIB battery expired. Replace battery and limit operations to within 3NM until replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2025
Resolved 30 April 2026
Resolution: EPRIB replaced battery
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions. Vessel Captain reported a failure of generator electrical down-voltage regulator. Repair or replace failed down-voltage regulator within 14 days. 46 CFR 143.400(a) & (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 7 May 2025
Resolution: Galco electronics replaced voltage regulator and provided work reciept.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2024 Resolved
All fixed fired extinguishing systems must be inspected or tested at least once every 12 months. Vessel shall have its fixed fire system serviced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: Fire system was serviced. Report provided the the USCG.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 July 2023 Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. EPIRB hydrostatic release unit found expired. Replace unit. If immediate replacement cannot be provided create temporary instructions and maintain on board readiness to manually deploy unit in case of emergency.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2023
Resolved 24 August 2023
Resolution: Received photographs indicating replacement of HRU.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 31 July 2023 Resolved
Each U.S. flag vessel subject to the Great Lakes Agreement must have an inspection of the required radiotelephone installation at least once every 13 months. This inspection must be made while the vessel is in active service or within not more than one month before the date on which it is placed in service. GL inspection not conducted. Provide inspection report. 47 CFR 80.953(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2023
Resolved 1 December 2023
Resolution: Received copy of GLA certificate issued by technician.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 July 2022 Resolved
THE RESULTS OF THE INSPECTIONS REQUIRED BY 33CFR164.76 MUST E DOCUMENTED IN THE TVR OR OFFICIAL LOGBOOK (TOWING GEAR) 46 CFR 140.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 31 August 2022
Resolution: Received email from Master stating they were logging the inspections in the TVR
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 July 2022 Resolved
EPIRB REGISTRATION IS EXPIRED VESSEL LIMITED TO 3MILES FROM SHORE 46 CFR 80.1061
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 31 August 2022
Resolution: Recieved proof of Gov't EPIRB registration into the PRMS database. Updated vessel details with registration number.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2022 Resolved
A TOWING VESSEL 79' OR MORE MUST CARRY FOUR LIFEBUOYS WITH ON EACH SIDE OF THE OPERATING STATION. 1. MUST HAVE LIFELINE SECURED AROUND THE BODY 2. MUST HAVE APPROVED FLOATING WATERLIGHT 46 CFR 141.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 20 September 2022
Resolution: Lifebuoys are installed satisfactorily
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2022 Resolved
EACH TOWING VESSEL MUST CARRY AT LEAST ONE APPROVED LIFEJACKET WITH LIGHT AND WHISTLE. ADDITIONALLY, A SUFFICIENT NUMBER OF ADDITIONAL LIFEJACKETS MUST BE CARRIED AT MANNED WATCHSTATIONS 46 CFR 141.340
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2022
Resolution: Sufficient lifejackets are properly stowed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2022 Resolved
EXPIRED CONTENTS FOUND IN FIRST AID KIT 46 CFR 140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Recieved statement from Master that expired items were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 July 2022 Resolved
CHARTS USED FOR NAVIGATION MUST BE UPDATED 46 CFR 140.705
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Received statement from Master that they obtained new charts, accessed LNM, and updated GPS charts through WiFi
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 July 2022 Resolved
ODORIZING WINTERGREEN REQUIRED ON SYSTEMS INSTALLED AFTER JULY 9, 2013. INSTALL WARNING AS NECESSARY FOR SPACES STORING CO2 46 CFR 76.15-60 78.47-11c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 9 November 2022
Resolution: Recieved confirmation from the vessel that a wintergreen odorizing agent has been added into the fixed CO2 system on board by Healey Fire Protection
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 July 2022 Resolved
MAINTAIN IMMERSION SUITS IAW MANUFACTURER'S INSTRUCTIONS 46 CFR 141.350
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Recieved statement from Master stating they inpsected and waxed zippers IAW man. instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 July 2022 Resolved
REPLACE HYDROSTATIC RELEASE-SHELF LIFE IS PAST 5 YEARS 46 CFR 141.305(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2022
Resolution: Hydro release for liferaft was found installed satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2022 Resolved
PORTABLE FIRE EXTINGUISHERS MUST BE MAINTAINED IAW NFPA 10. GALLEY EXTINGUISHER-SHOW DOCUMENTATION OF 6 YEAR SERVICE PROVIDE APPROVED BRACKETS PLACE A 40:B EXTINGUISHER AT EACH FLAMMABLE STORAGE LOCKER 46 CFR 142.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2023
Resolved 17 November 2023
Resolution: Confirmed rectification via visual inspection and fire servicing records during 2023 annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2022 Resolved
PRESSURE RELIEF VALVES MUST BE TESTED TWICE EVERY 5 YEARS. VESSEL DOES NOT HAVE PROCEDURES FOR TESTING. SETTING IS UNKNOWN. ENSURE ALL OTHER TESTS REQUIRED BY THIS PART ARE COMPLETED AND LOGGED 46 CFR 143.245
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 17 October 2022
Resolution: New safety relief valves have been installed and tested satisfactorily. See narrative for further detail.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2022 Resolved
ALL SAFETY EQUIPMENT SHALL BE READY FOR USE AND MAINTAINED IAW MANUFACTURER. AED'S ARE NOT INSPECTED MONTHLY.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Master sent photos of monthly inspections log being completed as well as satisfactory battery check.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2022 Resolved
ELECTRICAL SYSTEMS AND EQUIPMENT MUST FUNCTION PROPERLY AND MINIMIZE FAILURES, FIRE, AND SHOCK HAZARDS. PLACE CVER OVER BATTERY IN WHEELHOUSE, REMOVE DEAD END WIRING, PLACE CONNECTIONS IN AN ENCLOSURE, PROVIDE PROPER SUPORTS FOR WIRING, VITAL EQUIPMENT SHALL BE PROPERLY WIRED. 46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Received photos of areas of concern addressed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 July 2022 Resolved
ENSURE CO2 IS SERVICED IAW 142.240
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2022 Resolved
LABEL OUT OF COMMISSION SYSTEMS INCLUDING EMERGENCY SHUT DOWNS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2022
Resolution: Recieved email from Master stating the engine shut down system has been labeled out of service. Plans are in the works to reestablish this system.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.