WESTBANK

WESTBANK is a 1991 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1991, most recently in March 2025, along with 79 deficiencies — 1 with no resolution recorded —.

Records from 1991 to 2025. Most recent: inspection, 24 March 2025.

Built
1991
Last inspected
24 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

361200
Flag
UNITED STATES
—
Maury page id
psix-361200

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 29 calendar years (1991–2025)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)26.0 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS INC · SOMERSET, MA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSTATEN ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX6307MMSI not assigned · expired · voluntarily equipped · granted 23 July 1997, cancelled 22 September 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

24 March 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8098684
10 June 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932209
22 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7720143
28 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658340
15 June 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7479531
14 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7224772
15 April 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175529
21 April 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941462
18 July 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6754341
28 May 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697131
16 May 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6417686
22 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6183304
10 May 2017 Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6142995
20 February 2017 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6093867
25 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5861705
2 April 2009 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3445112
2 May 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3204824
29 March 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2897642
29 September 2006 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2790051
24 March 2005 MARPOL Annex V Examination · Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2318611
25 May 2004 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2077546
17 September 2003 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1907566
4 April 2003 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1774597
26 September 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1697680
23 May 2002 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1620857
24 July 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074998
16 May 2001 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1449468
28 February 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058553
3 May 2000 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379055
24 April 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051824
29 October 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 799829
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786850
24 April 1998 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123833
13 April 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788680
30 April 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1099672
30 April 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776902
30 April 1996 MARPOL Annex V Examination · Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082797
26 April 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177211
29 April 1994 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860500
22 June 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845909
13 May 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848435
13 May 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137437
18 May 1992 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261421
18 June 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244555
18 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248114
18 April 1991 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227566

Deficiency record · 79

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. System did not automatically shut down engine when performing simulation test. 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2025
Resolution: Operator provided satisfactory video evidence of associated engine shutdown. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 March 2025 Resolved
Through hull fittings and shutoff valves shall be metal. 02 through hull fittings serving the bilge pump overboard discharges on the port bow of the vessel are non-metallic. 46 CFR 182.40-1(a)(3) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025 Resolved
Where rigid nonmetallic material is permitted for use in piping systems by this subpart, the following restrictions shall be adhered to: (4) The material specification shall show that the rigid nonmetallic material possesses characteristics adequate for its intended service and environment. Piping serving the FWD bilge overboard discharge is dry-rotted and in an un-serviceable condition, requiring replacement. 46 CFR 182.40-1(a)(4) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 March 2025 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. 02 fuel fill hoses are missing static bonding arrangements. 46 CFR 182.20-30(d) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of 02 fuel fill hoses with proper static bonding arrangments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Electric Submersible bilge pump located in the forepeak space is installed to automatically operate via a float switch. There was no visual indicator at the operating station to indicate when bilge pump is operating. 46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of Visual indicator at the operating station to indicate when bilge pump is operating.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 March 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy is missing vessel's name. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of VSL's name stynciled on to Ring Life Buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Portable fire extinguisher located FWD of helm is missing a proper bracket. Proper mounting bracket noted on extinguisher is required to be an approved installation. 46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of properly mounted bracket for fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024 Resolved
VESSEL REQUIRED TO DISPLAY PROPER NAVIGATION LIGHTS IAW INLAND NAVIGATION RULES / COLREGS. STERN LIGHT WAS INOPERABLE. REPAIR / REPLACE PRIOR TO OPERATING AT NIGHT OR IN RESTRICTED VISIBILITY. 33CFR83.20(b)
Action required: 705 - Other - as specified
Resolved 9 July 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 June 2024 Resolved
INSTALLED PRE-ENGINEERED / FIRE-BOY FIRE SUPPRESSION SYSTEM IS REQURIED TO SECURE ENGINE UPON ACTIVATION. DURING INSPCT. FIRE-BOY DID NOT SECURE ENGINE DURING TESTING. REPAIR / REPLACE TO [name withheld] 07 DAYS. 46CR420
Action required: 705 - Other - as specified
Resolved 9 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024 No resolution recorded
RIGID NON-METALLIC PIPING (PVC) NOT PERMITTED IN VITAL SYSTEMS. BILGE DEWATERING HOSE (ELECTRIC SUBMERSIBLE) EXITED HULL W/IN APPROX. 10" OF WATER-LINE VIA PVC ELBOW [UPSTREAM OF METALLIC BALL VALVE]. REPAIR / REPLACE PRIOR TO CREDIT DRYDOCK.
Action required: 705 - Other - as specified
Due 31 March 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
A portable hand bilge pump must be capable of discharging overboard. Install discharge hose to portable hand bilge pump so water can be discharged overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2021 Resolved
Provide servicing documentation for portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Install light at operating station to indicate automatic bilge pump operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of indicator light
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 June 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of cover installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019 Resolved
Install shutoff valves on all overboard discharges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2019 Resolved
Secure all electrical wires out of bilge at forward Rule pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 May 2019 Resolved
Secure all fasteners in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 April 2016 Resolved
AF01- Repair grounding wire near raw water strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 10 May 2016
Resolution: Received confirmation from the operator that the grounding wire was repaired.
Stability › Unintentional Flooding › General
Issued 29 March 2007 Resolved
Replace seal on lazarette hatch cover.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Stability › Weathertight Integrity › General
Issued 29 March 2007 Resolved
Repair broken hinge on engine cover.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 March 2007 Resolved
Make sea-strainer ready for inspection.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 September 2006 Resolved
Replace waterlight for ring buoy. Daytime ops only until cleared.
Due 14 October 2006
Resolved 8 May 2007
Lifesaving › Hand Flares › Expired
Issued 29 September 2006 Resolved
Provide 3 hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2005 Resolved
Provide servicing certificates for fixed and portable fire extinguishing equipment.
Due 18 May 2005
Resolved 20 May 2005
Resolution: Viewed updated/valid servicing certificates.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 March 2005 Resolved
Provide new copy of Emergency Instruction list. Copy o/b vsl is damaged.
Due 18 May 2005
Resolved 20 May 2005
Resolution: New copy of Emergency Instruction list posted o/b vsl.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 March 2005 Resolved
Provide new retro-reflective tape on all (27) adult lifejackets, and (2) child lifejackets.
Due 18 May 2005
Resolved 10 June 2005
Resolution: Viewed new retro tape on all jackets.
Engineering › Steering Gear System › Rudder
Issued 24 March 2005 Resolved
Repair leakage at rudder post.
Due 18 May 2005
Resolved 20 May 2005
Resolution: Got vsl underway to test for leakage, master made several hard turns, and there was no evidence of a leak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2005 Resolved
Properly terminate (2) dead - end wires in forepeak.
Due 18 May 2005
Resolved 30 June 2005
Resolution: Dead end wires have been properly terminated.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2005 Resolved
Provide original Certificate of Inspection.
Due 18 May 2005
Resolved 4 October 2005
Resolution: Vsl owner unable to find original COI, required owner to submit letter stating that the lost COI. Transferred to ACTIVITY #2507528 (def check)
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 May 2004 Resolved
Log monthly fire & MOB drills in bridge\training log.
Due 7 June 2004
Resolved 2 November 2004
Resolution: Fire & MOB drills logged.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 May 2004 Resolved
Provide current 2004 tides\current tables.
Due 7 June 2004
Resolved 2 November 2004
Resolution: 2004 tides\current tables onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2004 Resolved
Prove proper operation of port nav light, vessel restricted from night ops until repaired.
Due 7 June 2004
Resolved 2 November 2004
Resolution: Port nav light repaired and fully operational.
Lifesaving › Hand Flares › Quantity
Issued 25 May 2004 Resolved
Provide signaling devices (3 red flares\3 orange smoke)
Due 7 June 2004
Resolved 2 November 2004
Resolution: Signaling devices onboard.
Lifesaving › Lifebuoys
Issued 17 September 2003 Resolved
Install retroreflective tape to ring life buoy.
Due 24 September 2003
Resolved 19 March 2004
Lifesaving › Lifebuoys
Issued 17 September 2003 Resolved
Properly attach waterlight lanyard & lifeline to ring life buoy.
Due 24 September 2003
Resolved 19 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 September 2003 Resolved
Provide CG approved first aid kit or one which contains contents indicated at 46CFR160.041. LEGACY COMPONENT DESC: Medicine Chest
Due 24 September 2003
Resolved 19 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 17 September 2003 Resolved
Provide lifejacket donning placard.
Due 24 September 2003
Resolved 19 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 September 2003 Resolved
Extend distribution line to fixed fire extinguishing system 2" past last orifices (2). Pressure test piping (600 PSI) following installation. LEGACY COMPONENT DESC: Piping
Due 17 October 2003
Resolved 30 March 2004
Resolution: Rcvd fax fm Dr. Scalici indicating piping tested (Lund Fire Products Company, Inc. Certificate).
Operations/Management › Other Criminal/Civil Violations
Issued 4 April 2003 Resolved
Vessel failed to complete required hull exams. LEGACY COMPONENT DESC: Missed Required Hull Exams
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 4 April 2003 Resolved
Install cover to expansion tank.
Due 23 May 2003
Resolved 19 March 2004
Accommodation/Occupational Safety › Ventilation
Issued 23 May 2002 Resolved
Provide means to secure engine room ventilation. LEGACY COMPONENT DESC: engine room
Due 26 September 2002
Resolved 26 September 2002
Lifesaving › Lifebuoys
Issued 23 May 2002 Resolved
Ensure waterlight line to ring buoy is 3 to 6 feet in length and attached to the body of the ring buoy with a corrosion resistant clip.
Due 26 September 2002
Resolved 26 September 2002
Engineering › Bilge Water Management System
Issued 23 May 2002 Resolved
Install positive stop closure valve to discharge hose to rule submersible bilge pump. LEGACY COMPONENT DESC: Valve
Due 26 September 2002
Resolved 26 September 2002
Engineering › Bilge Water Management System
Issued 23 May 2002 Resolved
Provide portable hand bilge pump. LEGACY COMPONENT DESC: Pump
Due 26 September 2002
Resolved 26 September 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2002 Resolved
Provide servicing report of fixed fire extinguisher system.
Due 26 September 2002
Resolved 26 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2002 Resolved
Repair leak to main engine raw water suction near through hull fitting. LEGACY COMPONENT DESC: Valve
Due 26 September 2002
Resolved 26 September 2002
Engineering › Fuel Oil Service System
Issued 23 May 2002 Resolved
Replace fuel vent screen with 30 x 30 mesh. LEGACY COMPONENT DESC: Vent Pipe
Due 26 September 2002
Resolved 26 September 2002
Construction/Loadline
Issued 16 May 2001 Resolved
Dogging mechanizm on aft most scuttle inop. Provide proof of proper operation.
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Fire Fighting
Issued 16 May 2001 Resolved
Annual servicing not completed on fixed and portable fire extinguishers. Prove proper servicing.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Fire Fighting
Issued 16 May 2001 Resolved
Provide 3, 2.5 gallon fire buckets. Stencil "fire bucket" and attach a lanyard.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 16 May 2001 Resolved
Provide bilge high level alarm and indicating light in bilge.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001 Resolved
Post lifejacket donning placard.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001 Resolved
Separate childrens and adult life jackets.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001 Resolved
Provide proof of manoverboard drills by utilizing a log book.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 29 October 1999 Resolved
Replace expired distress signals.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Electrical
Issued 29 October 1999 Resolved
Provide enclosure for one of the batteries. (The other one is ok).
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999 Resolved
Repair broken bonding wire on rudder post.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Provide control heads appropriate to the CO2 bottles (50lb heads on 25lb bottles).
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Provide hydrostatic test for CO2 bottles.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Construction/Loadline
Issued 29 October 1999 Resolved
Renew bilge system flexible lines with lines suitable for service, meeting SAE J-1942.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Construction/Loadline
Issued 29 October 1999 Resolved
Provide bilge high level alarm.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Documentation
Issued 29 October 1999 Resolved
Prove compliance with rules pertaining to drug and alcohol testing.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Documentation
Issued 29 October 1999 Resolved
Provide all vessel documents for examination.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999 Resolved
Renew life ring buoy, line, and light. 60 ft. of black or UV resistant line and attach floating water light with corrosion resistant clip.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999 Resolved
Segregate child size life preservers from adult.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999 Resolved
Provide donning instructions for life preservers.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Weight test portable fire extinguishers.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Provide plans for review/approval of newly installed CO2 fire extinguishingsystem.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Renew improper A100 fittings with A300 fittings on CO2 system.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Renew improper A53-furnace welded piping with seamless or electron beam welded (A53-S or ERW) or (A106-S or ERW)
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999 Resolved
Provide operational tests and 600psi static test of CO2 system in presence of attending USCG Inspector.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 22 January 1999 Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999 Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999 Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Documentation
Issued 22 June 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 22 June 1993 Resolved
PROVIDE COPY OF DOCUMENTATION CERTIFICATE TO [name withheld] OF VALID CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 13 May 1993 Resolved
PROVIDE COPY OF DOCUMENTATION CERTIFICATE TO [name withheld] OF VALID CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 13 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 18 April 1991 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991