WESTBANK

WESTBANK is a 1991 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in March 2025, along with 18 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 24 March 2025.

Built
1991
Last inspected
24 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 March 2025
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

361200
Flag
UNITED STATES
Maury page id
psix-361200

Documentation record

Registered dimensions (L × B × D)26.0 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS INC · SOMERSET, MA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSTATEN ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

24 March 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8098684
10 June 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932209
22 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7720143
28 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658340
15 June 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7479531
14 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7224772
15 April 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175529
21 April 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941462
18 July 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6754341
28 May 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697131
16 May 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6417686
22 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6183304
10 May 2017 Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6142995
20 February 2017 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6093867
25 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5861705

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. System did not automatically shut down engine when performing simulation test. 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2025
Resolution: Operator provided satisfactory video evidence of associated engine shutdown. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 March 2025 Resolved
Through hull fittings and shutoff valves shall be metal. 02 through hull fittings serving the bilge pump overboard discharges on the port bow of the vessel are non-metallic. 46 CFR 182.40-1(a)(3) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025 Resolved
Where rigid nonmetallic material is permitted for use in piping systems by this subpart, the following restrictions shall be adhered to: (4) The material specification shall show that the rigid nonmetallic material possesses characteristics adequate for its intended service and environment. Piping serving the FWD bilge overboard discharge is dry-rotted and in an un-serviceable condition, requiring replacement. 46 CFR 182.40-1(a)(4) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 March 2025 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. 02 fuel fill hoses are missing static bonding arrangements. 46 CFR 182.20-30(d) "OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of 02 fuel fill hoses with proper static bonding arrangments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Electric Submersible bilge pump located in the forepeak space is installed to automatically operate via a float switch. There was no visual indicator at the operating station to indicate when bilge pump is operating. 46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of Visual indicator at the operating station to indicate when bilge pump is operating.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 March 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy is missing vessel's name. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of VSL's name stynciled on to Ring Life Buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Portable fire extinguisher located FWD of helm is missing a proper bracket. Proper mounting bracket noted on extinguisher is required to be an approved installation. 46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of properly mounted bracket for fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024 Resolved
VESSEL REQUIRED TO DISPLAY PROPER NAVIGATION LIGHTS IAW INLAND NAVIGATION RULES / COLREGS. STERN LIGHT WAS INOPERABLE. REPAIR / REPLACE PRIOR TO OPERATING AT NIGHT OR IN RESTRICTED VISIBILITY. 33CFR83.20(b)
Action required: 705 - Other - as specified
Resolved 9 July 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 June 2024 Resolved
INSTALLED PRE-ENGINEERED / FIRE-BOY FIRE SUPPRESSION SYSTEM IS REQURIED TO SECURE ENGINE UPON ACTIVATION. DURING INSPCT. FIRE-BOY DID NOT SECURE ENGINE DURING TESTING. REPAIR / REPLACE TO [name withheld] 07 DAYS. 46CR420
Action required: 705 - Other - as specified
Resolved 9 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024 No resolution recorded
RIGID NON-METALLIC PIPING (PVC) NOT PERMITTED IN VITAL SYSTEMS. BILGE DEWATERING HOSE (ELECTRIC SUBMERSIBLE) EXITED HULL W/IN APPROX. 10" OF WATER-LINE VIA PVC ELBOW [UPSTREAM OF METALLIC BALL VALVE]. REPAIR / REPLACE PRIOR TO CREDIT DRYDOCK.
Action required: 705 - Other - as specified
Due 31 March 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
A portable hand bilge pump must be capable of discharging overboard. Install discharge hose to portable hand bilge pump so water can be discharged overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2021 Resolved
Provide servicing documentation for portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Install light at operating station to indicate automatic bilge pump operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of indicator light
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 June 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of cover installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019 Resolved
Install shutoff valves on all overboard discharges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2019 Resolved
Secure all electrical wires out of bilge at forward Rule pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 May 2019 Resolved
Secure all fasteners in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 April 2016 Resolved
AF01- Repair grounding wire near raw water strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 10 May 2016
Resolution: Received confirmation from the operator that the grounding wire was repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.