Records from 1991 to 2025. Most recent: inspection, 24 March 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
24 March 2025
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8098684
10 June 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932209
22 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7720143
28 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658340
15 June 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7479531
14 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7224772
15 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175529
21 April 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941462
18 July 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6754341
28 May 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697131
16 May 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6417686
22 June 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6183304
10 May 2017
Plan Review "T" Boat · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6142995
20 February 2017
Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6093867
25 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5861705
2 April 2009
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3445112
2 May 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3204824
29 March 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2897642
29 September 2006
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2790051
24 March 2005
MARPOL Annex V Examination · Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2318611
25 May 2004
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2077546
17 September 2003
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1907566
4 April 2003
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1774597
26 September 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1697680
23 May 2002
MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1620857
24 July 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074998
16 May 2001
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1449468
28 February 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058553
3 May 2000
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379055
24 April 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051824
29 October 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 799829
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786850
24 April 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123833
13 April 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788680
30 April 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1099672
30 April 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776902
30 April 1996
MARPOL Annex V Examination · Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082797
26 April 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177211
29 April 1994
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860500
22 June 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845909
13 May 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848435
13 May 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137437
18 May 1992
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261421
18 June 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244555
18 June 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248114
18 April 1991
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227566
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. System did not automatically shut down engine when performing simulation test.
46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2025
Resolution: Operator provided satisfactory video evidence of associated engine shutdown. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 March 2025
Resolved
Through hull fittings and shutoff valves shall be metal. 02 through hull fittings serving the bilge pump overboard discharges on the port bow of the vessel are non-metallic.
46 CFR 182.40-1(a)(3)
"OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025
Resolved
Where rigid nonmetallic material is permitted for use in piping systems by this subpart, the following restrictions shall be adhered to: (4) The material specification shall show that the rigid nonmetallic material possesses characteristics adequate for its intended service and environment. Piping serving the FWD bilge overboard discharge is dry-rotted and in an un-serviceable condition, requiring replacement.
46 CFR 182.40-1(a)(4)
"OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 March 2025
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. 02 fuel fill hoses are missing static bonding arrangements.
46 CFR 182.20-30(d)
"OLD-T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of 02 fuel fill hoses with proper static bonding arrangments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Electric Submersible bilge pump located in the forepeak space is installed to automatically operate via a float switch. There was no visual indicator at the operating station to indicate when bilge pump is operating.
46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of Visual indicator at the operating station to indicate when bilge pump is operating.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 March 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy is missing vessel's name.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of VSL's name stynciled on to Ring Life Buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2025
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Portable fire extinguisher located FWD of helm is missing a proper bracket. Proper mounting bracket noted on extinguisher is required to be an approved installation.
46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: Recieved satisfactory photo evidence of properly mounted bracket for fire extinguisher.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024
Resolved
VESSEL REQUIRED TO DISPLAY PROPER NAVIGATION LIGHTS IAW INLAND NAVIGATION RULES / COLREGS. STERN LIGHT WAS INOPERABLE. REPAIR / REPLACE PRIOR TO OPERATING AT NIGHT OR IN RESTRICTED VISIBILITY.
33CFR83.20(b)
Action required: 705 - Other - as specified
Resolved 9 July 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 June 2024
Resolved
INSTALLED PRE-ENGINEERED / FIRE-BOY FIRE SUPPRESSION SYSTEM IS REQURIED TO SECURE ENGINE UPON ACTIVATION. DURING INSPCT. FIRE-BOY DID NOT SECURE ENGINE DURING TESTING. REPAIR / REPLACE TO [name withheld] 07 DAYS.
46CR420
Action required: 705 - Other - as specified
Resolved 9 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024
No resolution recorded
RIGID NON-METALLIC PIPING (PVC) NOT PERMITTED IN VITAL SYSTEMS. BILGE DEWATERING HOSE (ELECTRIC SUBMERSIBLE) EXITED HULL W/IN APPROX. 10" OF WATER-LINE VIA PVC ELBOW [UPSTREAM OF METALLIC BALL VALVE]. REPAIR / REPLACE PRIOR TO CREDIT DRYDOCK.
Action required: 705 - Other - as specified
Due 31 March 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021
Resolved
A portable hand bilge pump must be capable of discharging overboard. Install discharge hose to portable hand bilge pump so water can be discharged overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2021
Resolved
Provide servicing documentation for portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Install light at operating station to indicate automatic bilge pump operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of indicator light
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 June 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 19 July 2021
Resolution: received video via email showing proof of cover installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2019
Resolved
Install shutoff valves on all overboard discharges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2019
Resolved
Secure all electrical wires out of bilge at forward Rule pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 May 2019
Resolved
Secure all fasteners in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 April 2016
Resolved
AF01- Repair grounding wire near raw water strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 10 May 2016
Resolution: Received confirmation from the operator that the grounding wire was repaired.
Stability › Unintentional Flooding › General
Issued 29 March 2007
Resolved
Replace seal on lazarette hatch cover.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Stability › Weathertight Integrity › General
Issued 29 March 2007
Resolved
Repair broken hinge on engine cover.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 March 2007
Resolved
Make sea-strainer ready for inspection.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 September 2006
Resolved
Replace waterlight for ring buoy. Daytime ops only until cleared.
Due 14 October 2006
Resolved 8 May 2007
Lifesaving › Hand Flares › Expired
Issued 29 September 2006
Resolved
Provide 3 hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2005
Resolved
Provide servicing certificates for fixed and portable fire extinguishing equipment.
Due 18 May 2005
Resolved 20 May 2005
Resolution: Viewed updated/valid servicing certificates.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 March 2005
Resolved
Provide new copy of Emergency Instruction list. Copy o/b vsl is damaged.
Due 18 May 2005
Resolved 20 May 2005
Resolution: New copy of Emergency Instruction list posted o/b vsl.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 March 2005
Resolved
Provide new retro-reflective tape on all (27) adult lifejackets, and (2) child lifejackets.
Due 18 May 2005
Resolved 10 June 2005
Resolution: Viewed new retro tape on all jackets.
Engineering › Steering Gear System › Rudder
Issued 24 March 2005
Resolved
Repair leakage at rudder post.
Due 18 May 2005
Resolved 20 May 2005
Resolution: Got vsl underway to test for leakage, master made several hard turns, and there was no evidence of a leak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2005
Resolved
Properly terminate (2) dead - end wires in forepeak.
Due 18 May 2005
Resolved 30 June 2005
Resolution: Dead end wires have been properly terminated.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2005
Resolved
Provide original Certificate of Inspection.
Due 18 May 2005
Resolved 4 October 2005
Resolution: Vsl owner unable to find original COI, required owner to submit letter stating that the lost COI. Transferred to ACTIVITY #2507528 (def check)
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 May 2004
Resolved
Log monthly fire & MOB drills in bridge\training log.
Due 7 June 2004
Resolved 2 November 2004
Resolution: Fire & MOB drills logged.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 May 2004
Resolved
Provide current 2004 tides\current tables.
Due 7 June 2004
Resolved 2 November 2004
Resolution: 2004 tides\current tables onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2004
Resolved
Prove proper operation of port nav light, vessel restricted from night ops until repaired.
Due 7 June 2004
Resolved 2 November 2004
Resolution: Port nav light repaired and fully operational.
Lifesaving › Hand Flares › Quantity
Issued 25 May 2004
Resolved
Provide signaling devices (3 red flares\3 orange smoke)
Due 7 June 2004
Resolved 2 November 2004
Resolution: Signaling devices onboard.
Lifesaving › Lifebuoys
Issued 17 September 2003
Resolved
Install retroreflective tape to ring life buoy.
Due 24 September 2003
Resolved 19 March 2004
Lifesaving › Lifebuoys
Issued 17 September 2003
Resolved
Properly attach waterlight lanyard & lifeline to ring life buoy.
Due 24 September 2003
Resolved 19 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 September 2003
Resolved
Provide CG approved first aid kit or one which contains contents indicated at 46CFR160.041. LEGACY COMPONENT DESC: Medicine Chest
Due 24 September 2003
Resolved 19 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 17 September 2003
Resolved
Provide lifejacket donning placard.
Due 24 September 2003
Resolved 19 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 September 2003
Resolved
Extend distribution line to fixed fire extinguishing system 2" past last orifices (2). Pressure test piping (600 PSI) following installation. LEGACY COMPONENT DESC: Piping
Due 17 October 2003
Resolved 30 March 2004
Resolution: Rcvd fax fm Dr. Scalici indicating piping tested (Lund Fire Products Company, Inc. Certificate).
Operations/Management › Other Criminal/Civil Violations
Issued 4 April 2003
Resolved
Vessel failed to complete required hull exams. LEGACY COMPONENT DESC: Missed Required Hull Exams
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 4 April 2003
Resolved
Install cover to expansion tank.
Due 23 May 2003
Resolved 19 March 2004
Accommodation/Occupational Safety › Ventilation
Issued 23 May 2002
Resolved
Provide means to secure engine room ventilation. LEGACY COMPONENT DESC: engine room
Due 26 September 2002
Resolved 26 September 2002
Lifesaving › Lifebuoys
Issued 23 May 2002
Resolved
Ensure waterlight line to ring buoy is 3 to 6 feet in length and attached to the body of the ring buoy with a corrosion resistant clip.
Due 26 September 2002
Resolved 26 September 2002
Engineering › Bilge Water Management System
Issued 23 May 2002
Resolved
Install positive stop closure valve to discharge hose to rule submersible bilge pump. LEGACY COMPONENT DESC: Valve
Due 26 September 2002
Resolved 26 September 2002
Engineering › Bilge Water Management System
Issued 23 May 2002
Resolved
Provide portable hand bilge pump. LEGACY COMPONENT DESC: Pump
Due 26 September 2002
Resolved 26 September 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2002
Resolved
Provide servicing report of fixed fire extinguisher system.
Due 26 September 2002
Resolved 26 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 May 2002
Resolved
Repair leak to main engine raw water suction near through hull fitting. LEGACY COMPONENT DESC: Valve
Due 26 September 2002
Resolved 26 September 2002
Engineering › Fuel Oil Service System
Issued 23 May 2002
Resolved
Replace fuel vent screen with 30 x 30 mesh. LEGACY COMPONENT DESC: Vent Pipe
Due 26 September 2002
Resolved 26 September 2002
Construction/Loadline
Issued 16 May 2001
Resolved
Dogging mechanizm on aft most scuttle inop. Provide proof of proper operation.
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Fire Fighting
Issued 16 May 2001
Resolved
Annual servicing not completed on fixed and portable fire extinguishers. Prove proper servicing.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Fire Fighting
Issued 16 May 2001
Resolved
Provide 3, 2.5 gallon fire buckets. Stencil "fire bucket" and attach a lanyard.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 16 May 2001
Resolved
Provide bilge high level alarm and indicating light in bilge.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001
Resolved
Post lifejacket donning placard.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001
Resolved
Separate childrens and adult life jackets.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 16 May 2001
Resolved
Provide proof of manoverboard drills by utilizing a log book.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 29 October 1999
Resolved
Replace expired distress signals.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Electrical
Issued 29 October 1999
Resolved
Provide enclosure for one of the batteries. (The other one is ok).
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999
Resolved
Repair broken bonding wire on rudder post.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Provide control heads appropriate to the CO2 bottles (50lb heads on 25lb bottles).
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Provide hydrostatic test for CO2 bottles.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Construction/Loadline
Issued 29 October 1999
Resolved
Renew bilge system flexible lines with lines suitable for service, meeting SAE J-1942.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Construction/Loadline
Issued 29 October 1999
Resolved
Provide bilge high level alarm.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Documentation
Issued 29 October 1999
Resolved
Prove compliance with rules pertaining to drug and alcohol testing.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Documentation
Issued 29 October 1999
Resolved
Provide all vessel documents for examination.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999
Resolved
Renew life ring buoy, line, and light. 60 ft. of black or UV resistant line and attach floating water light with corrosion resistant clip.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999
Resolved
Segregate child size life preservers from adult.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999
Resolved
Provide donning instructions for life preservers.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Weight test portable fire extinguishers.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Provide plans for review/approval of newly installed CO2 fire extinguishingsystem.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Renew improper A100 fittings with A300 fittings on CO2 system.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Renew improper A53-furnace welded piping with seamless or electron beam welded (A53-S or ERW) or (A106-S or ERW)
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 29 October 1999
Resolved
Provide operational tests and 600psi static test of CO2 system in presence of attending USCG Inspector.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Fire Fighting
Issued 22 January 1999
Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999
Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 22 January 1999
Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Documentation
Issued 22 June 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 22 June 1993
Resolved
PROVIDE COPY OF DOCUMENTATION CERTIFICATE TO [name withheld] OF VALID CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 13 May 1993
Resolved
PROVIDE COPY OF DOCUMENTATION CERTIFICATE TO [name withheld] OF VALID CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 13 May 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 18 April 1991
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991