MAURY USCG vessel records Sign in
← All vessels

MARLIN

MARLIN is a 1987 tank ship. The Coast Guard has recorded 24 inspections since 1991, most recently in October 2007, along with 16 deficiencies and 1 operational control.

Records from 1991 to 2007. Most recent: inspection, 21 October 2007.

Built
1987
Last inspected
21 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8420610 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
361225
Flag
MARSHALL ISLANDS
—
Maury page id
psix-361225

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (1991–2007)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it83870 - Dead Weight, Ton
98800 - Displacement, Ton
43733 - Regulatory (Subpart C or D), Gross Ton
43733 - Convention (Subpart B), Gross Ton
26601 - Regulatory (Subpart C or D), Net Ton
26601 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

21 October 2007 ISPS II Exam · MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3082358
23 January 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2571797
23 January 2006 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2571837
1 April 2005 COC-TVE Annual
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2324305
7 June 2004 MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2090868
10 March 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2021920
9 March 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2021333
7 February 2004 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2002295
17 January 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1479398
12 January 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1476338
11 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291745
11 July 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1403419
26 February 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 426014
3 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425224
1 February 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 424302
20 March 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 413676
20 March 1998 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1113611
8 March 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413426
8 March 1998 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1109094
11 August 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 394228
27 April 1994 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 858364
20 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 352109
20 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1260984
3 February 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1218346

Deficiency record · 16

Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 7 February 2004 Resolved
SUBMIT IN WRITING TO NYCMI DISCHARGE PLAN FOR DISCHARGING THROUGH SLOP DISCHARGE LINE DUE TO TEMPORARY REPAIR IN PIPE PRIOR TO TRANSFER OPERATIONS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2004
Pollution Prevention/Response › Prevention Equipment
Issued 7 February 2004 Resolved
MAKE PERMANENT REPAIRS TO CRACK IN SLOP TANK PIPING SYSTEM IWO STBD MANIFOLD PRIOR TO NEXT US PORT TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2004
Resolution: Received Class report from Det Norske Veritas showing item has been corrected.
Deck/Cargo
Issued 7 February 2004 Resolved
PRIOR TO NEXT US PORT MAKE ALL PROPER REPAIRS TO RAILINGS AND CATWALKS THAT WERE DAMAGED IN WEATHER TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: RAILINGS/CATWALKS
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2004
Resolution: Received Class report from Det Norske Veritas showing item has been corrected.
Deck/Cargo
Issued 7 February 2004 Resolved
PRIOR TO CARGO OPERATIONS FROM #3 STBD CARGO TANK MAKE PROPER REPAIRS TO FRAMO PIPING SYSTEM LEGACY COMPONENT DESC: FRAMO HYD SYETEM
Action required: 705 - Other - as specified
Resolved 10 March 2004
Resolution: SMALL PIN SIZED HOLE WAS FOUND ON THE AFT SIDE OF THE VALVE BODY, WHICH WAS CAUSING HYDRAULIC OIL TO LEAK. VALVE HAS BEEN REPLACED AND FOUND SATISFACTORY BY CLASS.
Lifesaving › Inflatable Liferafts
Issued 7 February 2004 Resolved
PRIOR TO DEPARTURE FROM PORT OF NY MAKE PROPER REPAIRS TO FORWARD LIFE BRACKET
Action required: 705 - Other - as specified
Resolved 10 March 2004
Resolution: LIFERAFT WAS REPLACED . THE RAFT WAS PROPERLY INSTALLED AND FOUND IN GOOD ORDER TO THE SATISFACTION OF CLASS.
Deck/Cargo
Issued 7 February 2004 Resolved
PRIOR TO NEXT U.S PORT MAKE ALL REPAIRS TO ALL PIPING ( HEATLINE,WATER TANK CLEANING) ON FORWARD PART OF SHIP THAT WAS DAMAGED IN WEATHER LEGACY COMPONENT DESC: PIPING/MISC
Action required: 705 - Other - as specified
Resolved 9 March 2004
Resolution: Received Class report from Det Norske Veritas showing item has been corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 7 February 2004 Resolved
PRIOR TO NEXT US PORT MAKE PROPER REPAIRS, LEADING INTO SEWAGE TANK LEGACY COMPONENT DESC: Sewage System Tank
Action required: 705 - Other - as specified
Resolved 9 March 2004
Resolution: Received Class report from Det Norske Veritas showing item has been corrected.
Deck/Cargo
Issued 26 February 1999 Resolved
Prior to next VCS ops ensure high vapor pressure alarm meets 46 CFR 39.20- 13. To be completed to the satisfaction of class (DNV).
Condition: Unknown
Due 27 February 1999
Resolved 11 January 2002
Resolution: FAX FROM AGENT WITH DNV SURVEY
Navigation
Issued 1 February 1999 Resolved
ECHO DEPTH SOUNDER INOPERABLE. 33 CFR 164.35(h)
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Construction/Loadline
Issued 1 February 1999 Resolved
LOAD LINE NOT PERMANENTLY AFFIXED OR IN CONTRASTING COLORS. ICLL REG 8
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Deck/Cargo
Issued 8 March 1998 Resolved
IGS #2 BLOWER BYPASS VALVE INOPERABLE.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Engineering
Issued 8 March 1998 Resolved
THE STARBOARD SLUDGE TANK PV TEST VALVE WAS DISCONNECTED.
Condition: Unknown
Due 20 March 1998
Resolved 20 March 1998
Electrical
Issued 8 March 1998 Resolved
EMERGENCY BUS-TIE BREAKER AT EMERGENCY SWITCH BOAD IS BROKEN.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 20 July 1992 Resolved
THE VESSELS SECONDARY STEERING CONTROL SYSTEM COULD NOT BE BROUGHT INTO OPERATION FROM THE BRIDGE AS REQUIRED BY 33 C.F.R. 164.39(d)(1). THE MASTERSAID IT HAD WORKED THE PREVIOUS NIGHT WHEN THE PRE-ARRIVAL TESTS WERE DONE BUT AGREED THAT THE SYSTEM WAS NOT WORKING DURING OUR INSPECTION.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Deck/Cargo
Issued 20 July 1992 Resolved
SHOW PROPER OPERATION OF NO. 2 PORT P/V VALVE.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Navigation
Issued 3 February 1991 Resolved
Demonstrate proper operation of the 3 cm radar at next U.S. port.
Condition: Unknown
Due 3 February 1991
Resolved 3 February 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.