MAURY USCG vessel records Sign in
← All vessels

SALTY TOO

SALTY TOO is a 1991 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1991, most recently in May 2026, along with 82 deficiencies, 5 operational controls and 4 casualty investigations between 2016 and 2026.

Records from 1991 to 2026. Most recent: inspection, 24 May 2026.

Built
1991
Last inspected
24 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3099
361298
Flag
UNITED STATES
368398940
Maury page id
psix-361298

Inspections, by type

…with no type recorded10
Years with a record 29 calendar years (1991–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER BOATS INC · FT PIERCE, FL, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJUPITER, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9399MMSI 368398940 · active · compulsorily equipped · granted 28 December 2024, expires 28 December 2034
WDH7550MMSI 367649290 · expired · compulsorily equipped · granted 5 December 2014, cancelled 8 February 2025
WDB3099MMSI 366883380 · expired · compulsorily equipped · granted 27 February 2003, cancelled 4 May 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

24 May 2026 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8397534
4 March 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8319507
14 January 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8058850
14 June 2024 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7934828
23 April 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7900135
12 April 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7667206
15 June 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7478019
14 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7430778
7 April 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7170243
6 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7072454
2 June 2020 Deficiency Check · Internal Structural Exam · In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6966113
16 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6940125
24 January 2020 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6890739
24 April 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6669159
29 June 2018 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 6499329
23 May 2018 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6421468
4 May 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6405621
7 July 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6204112
4 May 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6138635
13 May 2016 Internal Structural Exam · Damage Survey · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5878339
13 May 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5881387
27 February 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5881245
27 February 2016 Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5881393
25 February 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5821630
22 August 2015 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5225790
22 August 2015 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5233753
10 May 2007 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2915265
18 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2901777
19 March 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890529
20 June 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2685631
9 March 2005 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292757
24 February 2005 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2311752
24 March 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2049078
2 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2016465
11 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1754060
27 February 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1746347
21 May 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1618927
4 April 2002 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 1601658
9 April 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1075234
20 March 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063124
14 March 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452773
20 July 2000 Type not recorded
No type recorded · CGC POINT LOBOS · USCG Heartland District (CGD-H) · Activity 1515945
9 March 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1049177
2 October 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1352949
9 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386452
4 January 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416816
15 December 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032451
27 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 74658
26 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1418318
28 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092317
17 March 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390475
23 December 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094549
17 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847004
10 September 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949578
14 July 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183491
12 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1182177
12 June 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186138
6 December 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827764
20 June 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024805
15 June 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1017307
7 September 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1143331
6 September 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836482
18 December 1992 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 825591
19 June 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251494
3 May 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940238

Deficiency record · 82

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2025 Resolved
A vessel on which a pre-engineered fire extinguishing system is installed must have a means to reset devices used to automatically shut down engines. Engines unable to restart upon reseting system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2025
Resolution: Repaired, tested. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 January 2025 Resolved
The marine employer must have sufficient alcohol testing devices readily accessible. Devices expired. Vessel must be able to conduct alcohol tests within 2 hours.
Action required: 705 - Other - as specified
Resolved 16 January 2025
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2025 Resolved
All vessels must have nav lights in compliance with Nav Rules. Port light and anchor light are inoperable. Vessel restricted to daylight operations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 January 2025
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. V birth pump Indicator is inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 5 February 2025
Resolution: Tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 January 2025 Resolved
As appropriate for the intended voyage, a vessel must carry up-to-date: U.S. Coast Pilot [name withheld] List, Tides tables, and Current tables. Extracts from publications may be provided. Publications missing from vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 27 January 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro tape weathered and non-reflective.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 27 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025 Resolved
Flexible hose runs must be protected from mechanical damage. Fuel hoses missing supports and are rubbing on vessel causing some chafing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 5 February 2025
Resolution: Supports installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and vessel from electrical hazards. Electrical cables missing hangers and are just laying in the bilge. Some dead end cables in machinery space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025
Resolved 5 February 2025
Resolution: Supports installed. Dead end cables removed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 April 2024 Resolved
A vessel on which a pre-engineered system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down engines. System reset/override is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2024
Resolution: Fireboy bezel replaced. system tested. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 April 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Alcohol tested devices are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 April 2024 Resolved
A submersible electric bilge pump may be used provided that: The pump is permanently mounted. E/R bilge pump not mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 7 June 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 April 2024 Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents. First-aid kit had expired content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 7 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personal contact with energized parts. vessel has dead-end cables located in E/R and in Wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 7 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 April 2024 Resolved
A hatch exposed to the weather must be watertight. Fwd hatch not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 7 June 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 April 2023 Resolved
EPIRB's hydrostatic release is expired. Replace with current release. Operations restricted to no more than 3 miles from shore. 46 CFR 185.740
Action required: 705 - Other - as specified
Resolved 20 April 2023
Resolution: HRU replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 April 2023 Resolved
Stern navigation light is inoperable. Repair replace light prior to operating at night. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: Stern light operates SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2023 Resolved
1 adult life jacket in non-serviceable condition. Replace life jacket with approved type. Total persons reduced to 15. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: 1 adult life jacket replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2023 Resolved
Both bilge high level visual alarms are inoperable. Repair/replace visual alarms. 46 CFR 182.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 4 May 2023
Resolution: Visual alarms operate SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2023 Resolved
Portable fire extinguisher in v-berth is not mounted. Properly mount forward portable fire extinguisher. 46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 4 May 2023
Resolution: Extinguisher mounted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2023 Resolved
Navigation publication not onboard; rovide current publications. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 20 April 2023
Resolution: Pubs onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2021 Resolved
Fuel hose at fuel tank has excessive chaffing and must be replaced. Replace fuel hose and fittings with SAE J-1942 hose and SAE J-1475 fittings prior to carrying passengers. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Hose replaced SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021 Resolved
Vessel doesn't have a masthead light. Masthead light to be installed prior to carrying passengers. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Masthead light installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2021 Resolved
Missing 2-A fire extinguisher for accomodation space. Install required portable fire extinguisher prior to carrying passengers. 46 CFR 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Fire extinguisher onboard.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2021 Resolved
Vents for machinery space do not have closures. Provide some type closure device to both machinery space vents prior to carrying passengers. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Closure devices provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
Batteries do not have covers to prevent water splash. Install non-conductive covers over batteries. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 25 May 2021
Resolution: Covers installed on batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
Battery terminal connections found loose. Tighten and install permanent type connectors at all battery terminal connections. 46 CFR 183.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 23 May 2021
Resolution: Battery connections secured with permanent type connectors.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 April 2021 Resolved
Forward compartment bench area below emergency exit is wasted making step up to exit unsafe. Repair wasted area to the satisfaction of marine inspector. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 23 May 2021
Resolution: Bench repaired SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2021 Resolved
High water level visual alarms inoperable for both spaces. Repair alarms to allow operator to see and hear alarms when engergized. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 23 May 2021
Resolution: Alarms operate SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 October 2020 Resolved
Vessel does not have a Ceritificate of Documentation. Passenger operations suspended until a valid COD is issued. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2020
Resolution: COD issued.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2020 Resolved
Bilge high level alarms no separated to indicate the space of the high water level. Provide an audible and visual alarm for each required space and label alarm to indicate which space has high water level. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 8 July 2020
Resolution: Bilge alarms SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 June 2020 Resolved
VHF radio is not connected to GPS nor it GPS integrated. Connect radio to GPS or provide a GPS integrated radio onboard. 47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 8 July 2020
Resolution: Radio connected to GPS.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 June 2020 Resolved
All required certificates and documents not onboard. Provide all certs and docs prior to carrying passengers. 46 CFR 176.302
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2020
Resolution: Certs and Docs provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2020 Resolved
Prove proper operation of high water alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2020
Resolution: Proved proper operation of high water alarms.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2020 Resolved
Prove proper operation of high water alarms lights.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2020
Resolution: Installed new hight water alarm lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 January 2020 Resolved
Provide current hydrostatic release for epirb.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2020
Resolution: Provided new hydrostatic release for epirb.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 May 2019 Resolved
Install rail courses or equivalent at port, starboard and transom embarkation stations. 46 CFR 177.900
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 11 July 2019
Resolution: Rail equivalent installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 30 April 2019 Resolved
Found soft spots in flying bridge deck. Make repairs to the satisfactory of attending marine inspector. 46 CFR 176.610 Temporary repairs made; make permanent repairs at dry-dock.
Action required: 705 - Other - as specified
Due 18 June 2019
Resolved 24 January 2020
Stability › Watertight Integrity › General
Issued 4 May 2017 Resolved
Install metallic plug in capped off through hull valve.
Action required: 705 - Other - as specified
Resolved 16 May 2017
Resolution: Plug installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 May 2017 Resolved
Install handle on fuel shutoff valve.
Action required: 705 - Other - as specified
Resolved 16 May 2017
Resolution: Installed handle on valve, working properly.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 4 May 2017 Resolved
Prove proper operation of emergency tiller.
Action required: 705 - Other - as specified
Resolved 16 May 2017
Resolution: Proved proper operation of emergency tiller.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 May 2016 Resolved
Replace broken shaft IAW approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2016
Resolution: Owner replaced shaft in kind.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 13 May 2016 Resolved
Replace propeller IAW approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2016
Resolution: Owner replaced propeller in kind.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 27 February 2016 Resolved
Prove proper operation of main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2016
Resolution: Proved proper operation of main engine.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 February 2016 Resolved
Prove proper operation of vessels high water
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2016
Resolution: Proved proper operation of high water alarms.
Communications › Audible Communications › Horn/Whistle
Issued 25 February 2016 Resolved
Prove proper operation of horn.
Due 4 March 2016
Resolved 25 February 2016
Resolution: Proved proper operation of vessels horn.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 February 2016 Resolved
Seal hole in forward engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2016
Resolution: Sealed hole in engine room bulkhead.
Engineering › Steering Gear System › Piping
Issued 22 August 2015 Resolved
Repair/replace loose hydraulic fitting for steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2015
Resolved 22 August 2015
Resolution: Hydraulic fitting was replaced. Conducted sea trial and steering test, all sat.
Communications › Radio Communications › EPIRB
Issued 10 May 2007 Resolved
Relocate the EPIRB to a float free location and properly install the hydrostatic release.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 6 January 2015
Resolution: Installed new epirb in float free arrangement.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 May 2007 Resolved
Provide a portable light at the operating station.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 6 January 2015
Resolution: Owner provided portable light at the operating station.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2007 Resolved
Provide and install battery boxes for the batteries in the engine room as per 183.350(e).
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 6 January 2015
Resolution: Owner installed new battery boxes.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2007 Resolved
Clear all of the CG-835 items issued on July 20, 2006
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 6 January 2015
Resolution: All items cleared from 2006.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 June 2006 Resolved
Provide a current lifesaving equipment maintenance and bridge log as required by 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Owner provided lifesaving equipment maintenance and bridge log.
Navigation › Piloting/Steering › Marine Charts
Issued 20 June 2006 Resolved
Provide on board vessel up-to-date charts, U.S. Coast Pilot, light list, tide and current tables as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Owner provided up to date chart and pubs.
Lifesaving › Hand Flares › Expired
Issued 20 June 2006 Resolved
Provide three red hand flares and three orange day smoke flares as required by 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 21 June 2006
Resolution: Provided three red hand flares and three orange day smoke flares.
Communications › Radio Communications › EPIRB
Issued 20 June 2006 Resolved
Provide a hydrostatic release for EPIRB as required by 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Provided new hydrostatic release.
Construction/Loadline › Structures › Superstructure
Issued 20 June 2006 Resolved
Gouge and reweld cracked weld located on the flying bridge structure.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Ground out crack and re-welded flying bridge structure.
Lifesaving › Lifefloat › Serviceable
Issued 20 June 2006 Resolved
Clean life float to remove all mold as required by 46CFR176.808 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Lifefloat was clean and servicable.
Lifesaving › Lifebuoys › Serviceable
Issued 20 June 2006 Resolved
Provide a ring life buoy as required by 46 CFR 180.70
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 21 June 2006
Resolution: Provided a ring life buoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2006 Resolved
Properly support all electrical wiring in engine room as required by 46 CFR 183.340 to the satisfaction of he attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 6 January 2015
Resolution: Added metal supports to wiring in the engine room.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2005 Resolved
Replace expired eyewash and aspirin in first aid kit as per 46 CFR 160.041-4
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 11 March 2005
Resolution: Owner purchased new eyewash and aspirin.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 March 2005 Resolved
Provide proof of deckhand's enrollment in a drug program as required by 46 CFR 16.203
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 11 March 2005
Resolution: Owner provided proof deckhands enrollment in Gulf Coast Consortium.
Lifesaving › Lifefloat › Retroreflective Material
Issued 9 March 2005 Resolved
Renew worn retroreflective tape on lifefloats IAW NVIC 2-63.
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 17 March 2005
Resolution: Owner renewed tape IAW NVIC 2-63.
Documentation › Certificates/Documents › FCC SSL
Issued 9 March 2005 Resolved
Provide FCC station license as required by 47 CFR 80.
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 10 March 2005
Resolution: Owner faxed station license for examination. SAT.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 March 2005 Resolved
Repair electrical feed for engine override following fire system discharge required by 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2005
Resolved 9 March 2005
Resolution: Owner repaired bad disconnect at distribution box. Operational tested override-SAT.
Accommodation/Occupational Safety
Issued 15 March 2004 Resolved
Provide visual indicator for high level alarms IAW 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge High Level Visual Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 March 2004
Resolved 24 March 2004
Resolution: Operator installed high water indicato light IAW 46 CFR 182.630.
Construction/Loadline › Penetrations › Gasket
Issued 21 May 2002 Resolved
Repair gasket on hatch.
Due 21 May 2002
Resolved 21 May 2002
Resolution: repaired during inspection.
Lifesaving
Issued 20 March 2001 Resolved
PROVIDE PROOF OF REGISTRATION FOR EPIRB AS REQUIRED BY 46 CFR 185.728
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Electrical
Issued 20 March 2001 Resolved
PROVIDE COVERS OVER TERMINAL BLOCKS IN ENGINE ROOM TO PREVENT SHOCK AS REQUIRED BY 46 CFR 183.10-20
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Navigation
Issued 17 March 1997 Resolved
PROVIDE UP TO DATE CHARTS OF THE OPERATING AREA IAW 46 CFR 184.420.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997 Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT OR PROVIDE ALL REQUIRED ITEMS AND PROPERLY MARK BOX IAW 46 CFR 160.041 AND 184.710.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Engineering
Issued 17 March 1997 Resolved
PROVIDE AND PROPERLY INSTALL A FLAME/SPRAY SHIELD ON THE MAIN ENGINE FUEL STRAINER IAW 46 CFR 182.455 (a) (3).
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997 Resolved
PROVIDE ONE (1) ADULT COAST GUARD APPROVED TYPE I PFD IAW 46 CFR 180.71.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997 Resolved
PROVIDE AND PROPERLY MARK SEPARATED CHILD PFD STORAGE IAW 46 CFR 180.78 (a)(5).
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Navigation
Issued 17 March 1997 Resolved
PROVE PROPER OPERATION OF THE COMPASS LIGHT IAW 46 CFR 184.402 (c).
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Navigation
Issued 17 March 1997 Resolved
PROVE PROPER OPERATION OF THE AUX/EMERGENCY STEERING SYSTEM (TILLER) IAW 46CFR 182.620.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Lifesaving
Issued 17 March 1997 Resolved
PROVIDE AND PROPERLY INSTALL RETRO REFLECTIVE TAPE ON THE LIFE RING BUOY IAW 46 CFR 185.604 (b) (1).
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Documentation
Issued 10 September 1996 Resolved
Provice evidence of a valid FCC radio safety certificate.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Accommodation/Occupational Safety
Issued 12 June 1995 Resolved
Repair or replace hatch in way of bow._x001C_ (unable to adequately secure)
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Navigation
Issued 15 June 1994 Resolved
Repair stern light and anchor light. Vessel is restricted to daylight operations only until lights are repaired.
Condition: Unknown
Due 30 June 1994
Resolved 6 July 1994
Electrical
Issued 6 September 1993 Resolved
Make proper electrical connections for the Marine Sanitation Device inside an electrical box. The guidelines for wiring are contained in 46 CFR 183.05-50.
Condition: Unknown
Due 20 September 1993
Resolved 11 September 1993
Electrical
Issued 6 September 1993 Resolved
Provide portable emergency lighting (flashlight is sufficient), as requiredby 46 CFR 184.30-1.
Condition: Unknown
Due 20 September 1993
Resolved 11 September 1993
Fire Fighting
Issued 6 September 1993 Resolved
Provide hand fire pump as required by 46 CFR 181-10-5, prior to operating vessel with passengers aboard.
Condition: Unknown
Due 20 September 1993
Resolved 11 September 1993

Casualty record · 4

27 February 2016Routine · role: Involved in a Marine Casualty · activity 5881245
13 May 2016Routine · role: Involved in a Marine Casualty · activity 5881387
7 July 2017Routine · role: Acknowledged Pollution Source · activity 6204112
24 May 2026Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8397534
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEA SCOUT (2016–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.