Records from 1991 to 2016. Most recent: inspection, 15 July 2016.
Inspection history · 28
15 July 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5941963
10 August 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5211524
8 August 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 4949550
6 August 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4946060
10 November 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3888897
9 November 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3885513
9 November 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3888161
20 April 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3187470
5 February 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3142357
10 April 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2904903
23 March 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2608216
21 November 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1708991
20 March 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1495192
15 January 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728647
6 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275513
29 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 445096
14 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 421529
22 September 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 408259
17 September 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 395371
10 October 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383683
17 October 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 371511
7 February 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 364326
24 August 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 360540
25 November 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 476203
28 April 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 350427
21 October 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 536819
10 April 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 343054
2 April 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 342942
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 November 2010
Resolved
Main electrical conduit trunk line on main deck holed and wasted. Wastage located on junction boxes forward and aft of cargo hold #3.
Action required: 705 - Other - as specified
Due 24 November 2010
Resolved 12 November 2010
Resolution: Class wrote a condition to approve temp repairs and have it renewed in next dry-docking period.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 November 2010
Resolved
High Temp cooker return line from MDE has a soft patch.
Action required: 705 - Other - as specified
Due 24 November 2010
Resolved 12 November 2010
Resolution: class attested to repairs
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 November 2010
Resolved
E-Gen exhaust piping holed and wasted.
Action required: 705 - Other - as specified
Due 24 November 2010
Resolved 12 November 2010
Resolution: Class attested to repairs made by crew.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 November 2010
Resolved
High suction sea strainer missing bolts. Strainer only had 7 of the 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2010
Resolved 12 November 2010
Resolution: Crew put in the missing bolts, and class attested to the repair.
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 9 November 2010
Resolved
Hospital space was being used as sleeping quarters.
Condition: Placed in Improper Service
Due 10 November 2010
Resolved 10 November 2010
Resolution: Corrected on the spot. Extra crew member was brought on to help with an engine overhaul, upon arrival to port extra crew member was disembarked.
Lifesaving › Inflatable Liferafts
Issued 20 March 2002
Resolved
All liferafts (05) total were taken off for past due annual servicing. Vessel to fax copy of servicing report, to include verification liferafts on board, to MSO Philly office; prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2002
Resolution: Rcvd fax regarding the satisfactory servicing & verfication of all required liferafts on board.
Documentation › Logs/Records
Issued 20 March 2002
Resolved
The person in charge (Ch. Engineer) of the oil record book, on board the vessel failed to record required entries in the same; regarding the vessel's bunkering ops, from Jul-Dec'01. LEGACY COMPONENT DESC: Oil Record Book
Action required: 705 - Other - as specified
Resolved 20 March 2002
Resolution: The Master & Ch. Engineer were both instructed to ensure ALL required operations (including bunkering) were entered into the vessel''s oil record book.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 March 2002
Resolved
Broken rails were observed on the open main deck; located on the Port/Fwd, Port/Stern, & Stbd/Mid-Section areas. The damage was due to past container off-loading/loading operation(s). Vessel to have all broken rails repaired during next scheduled drydock to the satisfaction of class. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 November 2002
Resolution: Class sent fax attesting to repairs of broken hand-rails to MSO Philadelphia via facsimile.
Lifesaving
Issued 14 October 1998
Resolved
PROVIDE PROOF OF SOLAS APPROVAL OR PREVIOUS FLAG ADMINISTRATION APPROVAL OFPERSONAL LIFE JACKETS PRIOR TO VESSEL DEPARTURE FROM PORT.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Navigation
Issued 24 August 1993
Resolved
COPY OF U.S. INLAND NAVIGATION RULES NOT ON BOARD.
Condition: Unknown
Due 25 August 1993
Resolved 30 August 1993
Documentation
Issued 2 April 1991
Resolved
33CFR155.720 Vessel had no oil transfer procedures on board._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991