Records from 1991 to 2000. Most recent: inspection, 11 March 2000.
Inspection history · 41
11 March 2000
Port Security Assessment
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 583744
8 March 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 729858
21 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 174255
15 December 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435831
15 December 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435833
1 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 434314
29 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 767736
28 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 211418
6 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428353
1 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 428237
20 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425808
18 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 422706
16 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418365
18 May 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 144720
9 October 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 409021
8 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405558
16 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 404809
23 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 58151
12 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398411
29 October 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396910
8 October 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396122
16 September 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 395460
27 April 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 390211
10 October 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383662
18 September 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382997
25 August 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 670335
23 August 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 162164
12 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 694359
9 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 8231
7 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360038
1 July 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 670334
29 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 361800
28 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 151260
1 April 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 442994
27 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358550
24 January 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 359082
3 December 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 152821
31 October 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 516216
28 August 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 352850
9 November 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 454427
5 August 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 345149
Unknown
Issued 11 March 2000
Resolved
Provide class report regarding cause for moderate leaking of oil from vessel (stern tube leak suspected). Sheen present. Place boom around entirevessel immediately.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Navigation
Issued 11 March 2000
Resolved
Prior to departure vessel must provide gyro compass servicing report that equipment is in good working order. USCG was not notified of failure.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Navigation
Issued 11 March 2000
Resolved
By 04APR00 conduct pre-arrival/departure tests in accordance with 33 C.F.R.164.25.
Condition: Unknown
Due 4 April 2000
Resolved 11 March 2000
Engineering
Issued 11 March 2000
Resolved
Prior to departure repair exhaust leak from generator into engineroom.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Lifesaving
Issued 11 March 2000
Resolved
Prior to departure clean engineroom completely and pump waste oil in bilgesto shore.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Unknown
Issued 11 March 2000
Resolved
Prior to departure conduct re-exam with the USCG.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Unknown
Issued 11 March 2000
Resolved
Prior to departure provide letter of undertaking in the amount of $65,000 for violations #1, #2, and #5.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Unknown
Issued 11 March 2000
Resolved
Prior to departure have class society address severe shaft vibration between 170-200 rpm's.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000
Deck/Cargo
Issued 1 November 1999
Resolved
CARGO HATCH AND ANCHOR WINDLESS PUMP HAS SOFT PATCH ON HYDRO LINE
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Fire Fighting
Issued 1 November 1999
Resolved
FIRE MAIN LINE IN PAINT LOCKER AND FOWARD STRB. GEAR LOCKER HAVE SOFT PATCHES.
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Lifesaving
Issued 1 November 1999
Resolved
#2 FIREMANS MASK MISSING HEAD STRAPS
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Navigation
Issued 1 May 1999
Resolved
GMDSS NOT INSTALLED ONBOARD
Condition: Unknown
Due 1 May 1999
Resolved 3 May 1999
Documentation
Issued 1 May 1999
Resolved
SAFE MANNING CERT DID NOT REFLECT GMDSS OPERATORS
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Navigation
Issued 20 February 1999
Resolved
GMDSS NOT INSTALLED ONBOARD._x001C_ _x001C_ SOLAS 92 REG IV/8
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Unknown
Issued 18 November 1998
Resolved
REMOVE ALL FLAMMABLES FROM AFT MAIN DECK STORAGE._x001C_ SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Lifesaving
Issued 18 November 1998
Resolved
PROVIDE EXPIRATION DATE MARKING FOR EPIRB HYDROSTATIC RELEASE._x001C_ SOLAS 74 (AMENDED) III/7
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Lifesaving
Issued 18 November 1998
Resolved
PROVIDE EXPIRATION DATE MARKING FOR STBD SMOKE SIGNAL._x001C_ SOLAS 60 III/21(e)(g)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Electrical
Issued 18 November 1998
Resolved
REPLACE OR REPAIR ELECTRICAL BREAKER FOR THE ELECTRICAL HATCH CONTROL CABINET FOR THE NO.1 HATCH COVER._x001C_ SOLAS 74 (UNAMENDED) REG II/27(a)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Navigation
Issued 18 November 1998
Resolved
SERVICE AND PROVIDE REPORT FOR GYRO COMPASS, DIFFERENTIAL OF 10 DEGREES FROM MAGNETIC COMPASS._x001C_ SOLAS 74 (AMENDED) V/12(d)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Navigation
Issued 18 November 1998
Resolved
PROVIDE WARNING STATEMENT FOR MANUEVERING FACT SHEET.
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Lifesaving
Issued 18 November 1998
Resolved
PROVIDE BATTERIES FOR ALL DEFECTIVE LIGHTS ON LIFE JACKETS._x001C_ SOLAS 74 (AMENDED) III/27.2
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 18 November 1998
Resolved
PRESSURE WASH ENGINE ROOM AND BILGES. PUMP TO APPROVED SHORE FACILITY AND PROVIDE RECEIPT._x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Electrical
Issued 18 November 1998
Resolved
RENEW AS ORIGINAL AND PROPERLY TERMINATE ALL LOOSE WIREING AND ELECTRICAL BOXES IN ENGINE ROOM._x001C_ SOLAS 60 REG II/27(a)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 18 November 1998
Resolved
SERVICE FIRE EXTINGUISHER STBD SIDE OF GENERATOR IN ENGINE ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Electrical
Issued 18 November 1998
Resolved
PROVIDE PROPER COVERS FOR VARIOS LIGHTS IN ENGINE ROOM._x001C_ SOLAS 74 (UNAMENDED) REG II/27(a)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Engineering
Issued 18 November 1998
Resolved
PROVIDE CLASS REPORT ON MATERIAL CONDITION OF ALL ENGINE ROOM PIPING, ELECTRICAL CONTROLS, AND LEAKING MAIN ENGINE AND GENERATORS._x001C_ SOLAS 74 (UNAMENDED) II-2/33(a)
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 18 November 1998
Resolved
REMOVE EXCESS STORAGE FROM FIXED CO2 STORAGE AFT STEERING._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Engineering
Issued 18 November 1998
Resolved
REMOVE ALL PAINTS AND FLAMMABLES FROM ENGINE ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Lifesaving
Issued 18 November 1998
Resolved
PROVIDE PROPER MARKING FOR EMERGENCY ESCAPE ROUTES FROM ENGINE ROOM._x001C_ SOLAS 74 (UNAMENDED) REG II-2/53
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 18 November 1998
Resolved
REPAIR AS ORIGINAL THROTTLE LINKAGE ON EMERGENCY FIRE PUMP. (CONSTANT MANUEL CONTROL)_x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Fire Fighting
Issued 18 November 1998
Resolved
PROPERLY ANNOTATE AND COLOR CODE FIRE CONTROL PLANS TO SHOW CLASS A AND B BULKHEADS._x001C_ SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Fire Fighting
Issued 18 November 1998
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT SIDE CIRCULATING PUMP._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Lifesaving
Issued 18 November 1998
Resolved
REPLACE CRACKED RING BUOY FOREWARD STBD SIDE FOC'SLE._x001C_ SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 22 November 1998
Resolved 24 November 1998
Engineering
Issued 18 November 1998
Resolved
REPAIR AND PROVE PROPER OPERATION OF OILY WATER SEPARATOR._x001C_ MARPOL 73/78 I/16 _x001C_ TO BE REPAIRED PRIOR TO 19DEC98 AS PER CLASS REPORT DATED 22NOV98.
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Fire Fighting
Issued 18 November 1998
Resolved
REPAIR AND PROVE PROPER OPERATION OF NO.1 MAIN FIRE PUMP/GENERAL SERVICE PUMP. (REPLACE PACKING GLAND) ALSO MAKE PERMANENT REPAIRS TO GUAGES._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Fire Fighting
Issued 18 November 1998
Resolved
REPAIR AND PROVE PROPER OPERATION OF NO.2 FIRE PUMP/GENERAL SERVICE PUMP._x001C_ ALSO REPLACE SHAFT, SHAFT IS BADLY SCORED. SOLAS 74 (AMENDED) II-2/21 _x001C_ TO BE REPAIRD BY 19DEC98 AS PER CONDITION OF CLASS REPORT DATED 22NOV98
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Engineering
Issued 18 November 1998
Resolved
RENEW AS ORIGINAL LEAKING LUBE OIL COOLING UNIT._x001C_ SOLAS 74 (AMENDED) II-2/33(a) _x001C_ TO BE CORRECTED PRIOR TO 19DEC98 AS PER CLASS REPORT DATED 22NOV98.
Condition: Unknown
Due 21 February 1999
Resolved 21 February 1999
Documentation
Issued 16 June 1998
Resolved
PROVIDE LEGIBLE COPY OF OIL TRANSFER PROCEDURES
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Documentation
Issued 16 June 1998
Resolved
PROVIDE DOCUMENTATION FROM CLASS SOCIETY ADDRESSING PERIODIC SURVEY DATE ONLL CERTIFICATE AND MARK LOADLINE ON HULL IAW LOADLINE CERTIFICATE.
Condition: Unknown
Due 16 June 1998
Resolved 22 July 1998
Documentation
Issued 16 June 1998
Resolved
PROVIDE DOCUMENTATION FROM CLASS SOCIETY ADDRESSING TANK CAP ON IOPP SUPPLEMENT
Condition: Unknown
Due 16 June 1998
Resolved 22 July 1998
Documentation
Issued 16 June 1998
Resolved
PROVIDE DRYDOCK INFORMATION TO CG
Condition: Unknown
Due 16 June 1998
Resolved 22 July 1998
Engineering
Issued 16 June 1998
Resolved
REPAIR EXCESSIVE MAIN DIESEL ENGINE F/W LEAK
Condition: Unknown
Due 16 June 1998
Resolved 22 July 1998
Documentation
Issued 16 June 1998
Resolved
PUMP OFF EXCESSIVE OILY WATER IN BILGE AND PROVIDE RECEIPT TO CG
Condition: Unknown
Due 16 June 1998
Resolved 22 July 1998
Construction/Loadline
Issued 9 October 1997
Resolved
MAKE PERMANENT REPAIR TO HOLE IN BULKHEAD BETWEEN ENGINEROOM AND CARGO HOLD.
Condition: Unknown
Due 9 October 1997
Resolved 20 October 1997
Electrical
Issued 9 October 1997
Resolved
REMOVE UNUSED WIRES FROM BEHIND AIR CONPRESSOR & FRONT HYDRAULIC WINCH PUMPAND BOAT DECK PORT SIDE.
Condition: Unknown
Due 30 October 1997
Resolved 20 October 1997
Electrical
Issued 9 October 1997
Resolved
REPLACE PIPE THAT CARRIES ELECTRIC CABLE TO CARGO HOLD HYDRAULIC PUMP & BOWWINCHES._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Electrical
Issued 9 October 1997
Resolved
PROPERLY STORE ELECTRIC WIRES VICINITY STOVE._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Lifesaving
Issued 9 October 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 October 1997
Resolved 20 October 1997
Electrical
Issued 9 October 1997
Resolved
MAKE WATERPROOF SWITCHBOX IN LAUNDRY ROOM._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 30 October 1997
Resolved 20 October 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
REPAIR HANDRAIL AT BOAT DECK STARBOARD SIDE BY CRANE REST STAND._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Deck/Cargo
Issued 9 October 1997
Resolved
REPAIR AFT CARGO HOLD ACCESS DOOR._x001C_ CORRECT TO SATISFACTION TO CLASS SOCIETY.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Engineering
Issued 9 October 1997
Resolved
REPAIR DOOR COVER FOR FUEL VENT COMPATMENT STARBOARD SIDE._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY. PROVIDE CLASS REPORT TO LOCAL COAST GUARD OFFICE.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Deck/Cargo
Issued 9 October 1997
Resolved
REPAIR HOSES TO CARGO HOLD HATCH LOCKS (HYDRAULICS).
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Electrical
Issued 9 October 1997
Resolved
REPAIR LIGHT LAMP IN PAINT LOCKER._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 30 October 1997
Resolved 20 October 1997
Deck/Cargo
Issued 9 October 1997
Resolved
REPAIR HYDRAULIC FLUID LEAK TO CARGO HOLD PUMP FWD & CARGO HOLD HATCH LOCKS._x001C_ REPAIR TO SATISFACTION OF CLASS SOCIETY. PROVIDE COPY OF CLASS REPORT TO LOCAL COAST GUARD OFFICE.
Condition: Unknown
Due 25 May 1998
Resolved 25 May 1998
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
REMOVE ALL OIL FROM DECK PLATES IN ENGINEROOM.
Condition: Unknown
Due 30 October 1997
Resolved 20 October 1997
Fire Fighting
Issued 9 October 1997
Resolved
INSTALL EMERGENCY LIGHTS MAIN DECK FIXTURES._x001C_ CORRECT TO SATISFACTION OF CLASS SOCIETY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1997
Resolved 20 October 1997
Electrical
Issued 16 June 1997
Resolved
FOUND THREE LIGHT COVERS IN ENGINE ROOM MISSING. [name withheld] HAD SPARES AND AGRRED TO REPLACE PRIOR TO SHIP'S DEPARTURE.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Lifesaving
Issued 16 June 1997
Resolved
HANDLE FOR RUDDER OF LIFEBOAT WAS CORRODED AND CRACKED BUT WAS STILL FUNCTIONAL. TOLD MASTER THAT RUDDER MUST BE REPLACED PRIOR TO RETURNING TO U.S. WATERS. MASTER PROVIDED COPY OF WORK ORDER AND TO BE CORRECTED AT THE YARD. CORRECTED ON 08JUL97.
Condition: Unknown
Due 16 June 1997
Resolved 8 July 1997
Fire Fighting
Issued 16 June 1997
Resolved
ONE PORTABLE CO2 FIRE EXTINGUISHER MISSING IN LIFEBOAT. 2ND OFFICER REPLACED FIRE EXTINGUISHER PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Lifesaving
Issued 16 June 1997
Resolved
FOUND FIRST AID KIT MISSING FROM LIFEBOAT. 2ND OFFICER RESTORED FIRST AID KIT PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Engineering
Issued 8 October 1996
Resolved
REPAIR MDE WATER JACKET LEAK LOWER STBD SIDE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Lifesaving
Issued 8 October 1996
Resolved
MISSING NO. 1 SIGNAL FLAG.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
REPAIR INSIDE DOOR HANDLE AND ALARM ON FREEZER. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Lifesaving
Issued 8 October 1996
Resolved
PORT AND STBD LIFEBOUYS ATTACHED TO THE SMOKE SIGNALS ON BRIDGE WING WERE STUCK TO THE BRACKET. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 8 October 1996
Resolved
REPLACE/REFILL EMPTY PORTABLE FIRE EXTINGUISHER IN THE BRIDGE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 8 October 1996
Resolved
DEFICIENCY DELETED FROM CG VSL BOARDING REPORT AND ADDED TO DEFICIENCY #4. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Electrical
Issued 8 October 1996
Resolved
FIX-RENEW LIGHTS FIXTURES, BRACKETS, LIGHTS COVERS, ELECTRICAL RECEPTICLES(JUNTION BOXES) THROUGH OUT THE MAIN DECK AND BRIDGE WEATHER DECK. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Lifesaving
Issued 8 October 1996
Resolved
(2) PERSONAL FLOTATION DEVICES IN THE BRIDGE WERE MISSING THE WHISTLES. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Navigation
Issued 8 October 1996
Resolved
STEERING GEAR WIRING CROSSED; SWITCH #1 PUMP IN BRIDGE OPERATES PUMP #2 IN STEERING ROOM AND VICE VERSA. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 8 October 1996
Resolved
DEFICIENCY DELETED FROM VESSEL BOARDIND REPORT DUE TO DUPLICITY IN ITEM #19OF THE SAME REPORT.
Condition: Unknown
Due 8 October 1996
Resolved 9 October 1996
Construction/Loadline
Issued 8 October 1996
Resolved
CORRECT LOADLINE CLASS SOCIETY MARKING ON HULL AND MAKE IT PERMANENT TO THEHULL. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Navigation
Issued 8 October 1996
Resolved
MANEUVERING FACT SHEET MISSING THE WARNING STATEMENT. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
GALLEY EXHAUST HOOD EXCESSIVELY COVER WITH GREASE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 8 October 1996
Resolved
REPAIR SLUDGE PIPE FRACTURE OVERHEAD ENGINE ROMM S/S OF SHAFT,BELOW S/S FUEL PURIFIER. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Electrical
Issued 8 October 1996
Resolved
REMOVE BARE WIRE OF DROP LIGHT IN ENGINE ROOM. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
REPAIR GUARDRAIL INSIDE THE STACK SPACE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 8 October 1996
Resolved
REPAIR VALVE AT FIRE STATION LOCATED ON MAIN DECK S/S AFT CRANE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 8 October 1996
Resolved
REPAIR WATER LEAK ON MAIN FIRE PUMP. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
INSTALL DOG WHERE MISSING ON HACTH TO EMERGENCY FIRE PUMP. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 8 October 1996
Resolved
REMOVE EXCESS OIL FROM BILGES. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Electrical
Issued 8 October 1996
Resolved
INSTALL RUBBER MAT AT ELECTRICAL CONTROL BOARD. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 8 October 1996
Resolved
INSTALL BLANK FLANGE ON PIPELINE BETWEEN SLUDGE PUMP DISCHARGE AND OWS OVERBOARD DISCHARGE. DEFICIENCY CLEARED ON 13OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Navigation
Issued 8 October 1996
Resolved
REPAIR THE 1" WOBBLE IN RUDDER STOCK ASSEMBLY AND RENEW PACKING MATERIAL TOAVOID TAKE ON WATER WHEN VESSEL HAS CARGO. DEFICIENCY WAS TEMPORARILY REPAIR TO SATISFACTION OF CLASS.
Condition: Unknown
Due 22 February 1997
Resolved 22 February 1997
Documentation
Issued 10 October 1995
Resolved
PROVIDE AN APPROVED SOPEP ON BOARD VESSEL PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 October 1995
Resolved 21 November 1995
Construction/Loadline
Issued 18 September 1995
Resolved
PROVIDE GAUGINGS FOR ALL HATCH COVERS AND SUBMIT FOR CLASS REVIEW AND ACCEPTANCE
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Documentation
Issued 18 September 1995
Resolved
PROVIDE SUPPLEMENT FOR SAFETY EQUIPMENT CERTIFICATE
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Engineering
Issued 18 September 1995
Resolved
PROVIDE FLAME SCREENS FOR ALL FUEL OIL/LUBE OIL TANK VENTS PRIOR TO NEXT USBUNKERING BUT NO LATER THAN 02OCT95
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Documentation
Issued 18 September 1995
Resolved
PROVIDE ON BOARD A SFE MANNING CERTIFICATE
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Lifesaving
Issued 18 September 1995
Resolved
PROPERLY MOUNT FLOAT FREE CAT I 406 EPIRB
Condition: Unknown
Due 18 September 1995
Resolved 21 September 1995
Fire Fighting
Issued 18 September 1995
Resolved
PROVIDE ONE SPARE BREATHING BOTTLE FOR EACH FIREMANS OUTFIT
Condition: Unknown
Due 18 September 1995
Resolved 21 September 1995
Documentation
Issued 18 September 1995
Resolved
PROVIDE SUPPLEMENTAL FOR IOPP CERTIFICATE
Condition: Unknown
Due 2 October 1995
Resolved 21 September 1995
Lifesaving
Issued 18 September 1995
Resolved
PROVIDE ONE ORANGE FLOATING SMOKE (QUICK ACTING) FOR EACH SIDE OF VESSEL BRIDGE AT RING BUOY
Condition: Unknown
Due 18 September 1995
Resolved 21 September 1995
Lifesaving
Issued 18 September 1995
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR PORT LIFEBOAT IAW SOLAS
Condition: Unknown
Due 18 September 1995
Resolved 21 September 1995
Lifesaving
Issued 18 September 1995
Resolved
PROVIDE SERVICING FOR STBD DUNLOP 20 PERSON SOLAS A LIFERAFT
Condition: Unknown
Due 18 September 1995
Resolved 21 September 1995
Documentation
Issued 29 June 1993
Resolved
A violation of 46 CFR 42.13-40(a) in that the deckline was not plainly visible. Vessel subject to U.S. regs as per 46 CFR 2.01-13(b).
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Documentation
Issued 29 June 1993
Resolved
The Rosamagdalena, a vessel with an oil capacity of greater than 250 barrels, failed to provide complete oil transfer procedures.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993