Registered dimensions (L × B × D)55.8 ft × 17.0 ft × 6.5 ft
Registered tonnagegross 41 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBODEGA BAY, CA
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 8 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Net Ton 41 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
18 May 2026Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8375360
18 February 2025COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8075955
20 May 2024Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7915546
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 18 February 2025Resolved
At each inspection for certification...quarters, toilet and washing spaces...and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. MI identified that the toilet discharge flexible hose and surrounding piping for the toilet water supply line, located in the aft port-section of the engine room, had a consistent drip which worsened while the vessel was underway. Conduct repairs to the satisfaction of the Attending Marine Inspector, prior to the conclusion of vessel's next dry dock examination.
46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 21 February 2025
Resolution: Operator identified the source of the leak, and provided evidence to MI's satisfaction.
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General Description of the drill scenario and training topics. (46 CFR 185.520)
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1)Date of the drill and training; and (2)General Description of the drill scenario and training topics. Vessel was missing logs pertaining to fire fighting drills. Vessel owner and operator shall ensure that, moving forward, all required drills are properly entered into the vessel log. (46 CFR 185.524)
The master of the vessel shall ensure that: The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel was missing all required logs pertaining to drills; the last recorded drill in the vessel logbook was documented for January 2014. (46 CFR 185.728)
Vessel owner and operator shall ensure that, moving forward, all required drills are properly entered into the vessel log.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 February 2025
Resolution: Spoke with operators while onboard to remind them to properly format and log each drills onboard the vessel. Operators do not frequently use this vessel as a primary in their ownership.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 February 2025Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Paper charts on board last update reflected being in 2021. Provide up to date charts on board.
46 CFR 184.420
Action required: 10 - Deficiency Rectified
Resolved 27 February 2025
Resolution: Operator provided photo of charts.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 February 2020Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The vessel's onboard EPIRB had an expired battery. Replace the EPIRB battery IAW manufacterer's instructions.
46CFR180.64
Action required: 705 - Other - as specified
Due 9 March 2020
Resolved 1 March 2020
Resolution: Operator provided picture of EPIRB installed onboard the vessel and registered.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 June 2019Resolved
Each vessel that operatoes on the high seas must have on board a FCC Type Category 1, 406 MHz EPIRB installed to automatically float free and activate. The vessel's EPIRB battery was expired, and the hydrosatic release was expired.
46CFR180.64
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Owner procured new EPIRB and hydrostatic release.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 17 August 2017Resolved
Vessel has plastic waste receptacles in an lounge area. 46 CFR 177.30-7 (d)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 17 August 2017
Resolution: Trash Cans were removed from lounge area.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 August 2017Resolved
Heater supply valve from fuel tank has loose and unabled to be tightened. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 17 August 2017
Resolution: Crewmember turned nut around on valve stem and resecured valve handle to valve body. Handle properly secured.
SSDG failed to start. Batteries are dead and owner is unable to start the SSDG. Engine is required to be started and pre-engineered system emergency shutdown is required prior to Master using SSDG with passengers onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 19 September 2017
Resolution: Observed Engine Shutdown when testing pre-engineered firefighting system.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 17 August 2017Resolved
Batteries in lights are expired. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 17 August 2017
Resolution: Batteries were replaced.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.