MAURY USCG vessel records Sign in
← All vessels

APACHE MAIDEN

APACHE MAIDEN is a 1986 freight ship. The Coast Guard has recorded 26 inspections since 1991, most recently in May 2007, along with 12 deficiencies and 2 operational controls.

Records from 1991 to 2007. Most recent: inspection, 26 May 2007.

Built
1986
Last inspected
26 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8608781 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
361621
Flag
PANAMA
—
Maury page id
psix-361621

Inspections, by type

…with no type recorded24
Years with a record 10 calendar years (1991–2007)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23325 - Dead Weight, Ton
14499 - Regulatory (Subpart C or D), Gross Ton
8539 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

26 May 2007 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2940723
30 March 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2612548
8 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2599083
10 February 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2582912
9 February 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2582153
4 June 2001 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 290421
25 June 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430066
15 August 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 394267
26 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 386249
20 September 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 382912
2 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 379906
27 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 373619
27 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 849125
15 July 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 682950
14 July 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 368503
2 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 436305
8 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 682951
27 October 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 465758
9 July 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 479367
2 July 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 359275
20 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 446929
6 December 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 354930
28 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 537551
8 May 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 350524
3 May 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 350550
13 April 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 343164

Deficiency record · 12

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 May 2007 Resolved
Discovered one-way value connected to the oily water separator. Verify pipe connection in accordance with oily water separator diagram and provide classification society report to U.S. Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 July 2007
Resolution: Sector San Juan received a class report from NKK stating that the one-way valve leading off the overboard discharge line is a siphon break and the design does not allow oily bilge to bypass the OWS. NKK has advised company to keep piping system as is.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 February 2006 Resolved
Radar not properly functioning. Granted LOD to depart San Juan.
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 26 May 2007
Resolution: Inspectors verified proper operation of both radars during PII/ISPSII exam on 26MAY2007 in San Juan, PR.
Construction/Loadline › Penetrations › Gasket
Issued 9 February 2006 Resolved
Shaft seal not in proper operation; leakage estimated at several gallons perday. To be repaired within 14 days to the satisfaction of Class/Flag.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2006
Resolved 26 May 2007
Resolution: Sector San Juan verified proper operation of shaft seal without leakage.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 February 2006 Resolved
Inoperative primary radar observed by CG Inspectors after vessel entered San Juan Harbor; COTP Order issued and LOU obtained - see "Operational Control." To be repaired prior to departure to the satisfaction of Class/Flag.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2006
Lifesaving › Lifeboat Equipment › Food Ration
Issued 9 February 2006 Resolved
Expired lifeboat food rations; to be replaced prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2006
Navigation
Issued 15 August 1996 Resolved
PROVIDE A CURRENT COPY OF THE TIDE TABLES ON BOARD VESSEL. VESSEL DID HAVEA COPY OF BA VOL 2, BUT IT WAS FOR 1995. VESESEL DIDN'T HAVE A CURRENT COPYOF TIDE TABLES FOR ENTERING THE PORT OF SAVANNAH.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Navigation
Issued 15 August 1996 Resolved
PROVIDE THE TIDAL CURRENT TABLES ON BOARD. VESSEL HAD A 1995 COPY OF BA TIDAL CURRENT TABLES ON BOARD. VESSEL DID NOT HAVE ON BOARD A CURRENT COPY OF THE TIDAL CURRENT TABLES FOR ENTERING THE PORT OF SAVANNAH.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Accommodation/Occupational Safety
Issued 2 July 1995 Resolved
Make permanent repairs to flange/pump interface at bottom of sewage collection pump, prior to returning to a U. S. port, per SOLAS CHPT II-1 REG 26(1).
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Construction/Loadline
Issued 2 July 1995 Resolved
Make permanent repairs to deck drain overboard piping immediately above thesea valve, port lower level, prior to returning to a U. S. port, per SOLAS CHPT II-1 REG 26(1).
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Navigation
Issued 14 July 1994 Resolved
The vessel was in violation of 33 CFR 164.33 when they did not have the 1994 Tidal Current Tables on board for the area transitted.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 14 July 1994 Resolved
The vessel was in violation of 33 CFR 164.33 when both Coast Pilots on board the vessel were outdated and missing corrections that pertained to the vessels transit in the Savannah River.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 14 July 1994 Resolved
The vessel was in violation of 33 CFR 164.33 when they did not have any 1994 Tide Tables on board for the area transited.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.