Records from 1992 to 2026. Most recent: inspection, 25 March 2026.
Inspection history · 81
25 March 2026
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8332181
18 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8117446
25 March 2025
Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8099699
14 May 2024
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7913187
13 May 2024
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7911830
17 April 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7896879
14 November 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7826237
19 October 2023
Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7812854
7 August 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7762884
20 March 2023
Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7653759
12 December 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7609199
24 August 2022
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7542452
12 May 2022
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7448769
19 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7435105
9 August 2021
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7282060
20 May 2021
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7202291
24 August 2020
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7145918
7 June 2019
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6709988
10 January 2019
Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6608524
8 January 2019
COI Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6607903
3 May 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6403576
22 December 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6327931
19 July 2017
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6307666
28 June 2016
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6056738
27 April 2016
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860515
13 July 2015
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5184501
19 June 2012
Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4349516
11 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4349510
2 May 2012
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4300424
24 August 2011
Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4126109
7 July 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4074632
5 October 2010
Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3864067
3 October 2010
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3864780
22 April 2009
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3452323
19 August 2008
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3303170
12 August 2008
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3296889
30 April 2008
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3208749
23 April 2007
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2914071
14 April 2007
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2907802
11 April 2007
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2906006
30 March 2007
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2898649
29 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2897996
16 January 2007
COI Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2856737
5 September 2006
Hull Examination · Inclining Experiment · Construction Oversight
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2769529
22 February 2006
Construction Oversight
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2590856
15 May 2005
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2368404
24 March 2005
Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2338123
8 June 2004
Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2092752
19 September 2003
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1910255
19 August 2003
Periodic Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1890230
19 June 2003
Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1824750
14 December 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1724647
15 July 2001
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1076373
29 June 2001
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 680627
18 June 2001
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1464393
18 September 2000
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 133106
10 May 2000
Re-Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1470567
1 December 1999
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 104637
25 June 1999
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1450312
18 November 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 729823
12 September 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 177694
23 April 1998
Deficiency Check · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1126629
13 April 1998
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1123081
14 May 1997
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1364137
24 May 1996
Deficiency Check · Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359108
16 May 1996
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1082736
19 April 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1081291
18 April 1996
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1096561
18 April 1996
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431625
30 June 1995
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1190738
28 June 1995
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 880868
20 June 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1190552
30 May 1995
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 873531
13 May 1995
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1219213
11 May 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1428483
6 July 1994
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1133849
24 May 1993
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1145175
24 May 1993
Initial Certification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1389670
22 January 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 680626
4 January 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 18790
7 July 1992
Deadweight Survey · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1356132
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 April 2024
Resolved
Drills were not conducted due to weather. Conduct drills to include MOB, fire drill, and abandon ship.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 13 May 2024
Resolution: conducted satisfactory drills
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2024
Resolved
In stbd accommodation space, one deadend electrical cable was present, place in J-box or remove. Two j-boxes did not have a cover on them.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 13 May 2024
Resolution: All deadend wires were covered.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2024
Resolved
In engineer's stateroom, light was hanging by electrical wires, provide light fixture. Outlet was missing a cover, provide.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 13 May 2024
Resolution: repaired
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2024
Resolved
In the laundry room, the distribution panel had two openings, provide blanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 13 May 2024
Resolution: openings were blanked
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 August 2023
Resolved
No record of drills were found. The master shall conduct sufficient drills and five sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Log drills prior to conducting cargo ops. Fire drills : 46CFR185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
Resolution: received email showing logged drills
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2023
Resolved
Forward fire station leaks at flange. Repair/renew
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: gasket renewed, test sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2023
Resolved
Forward fire station valve is inoperable. Repair/renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: valve renewed, test sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 August 2023
Resolved
Engine room emergency escape was blocked. Ensure escape is clear.
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 7 August 2023
Resolution: pump sitting on escape was moved
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2023
Resolved
New portable fire extinguisher in engine room at bottom of ladder is not mounted. Mount extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: mounted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2023
Resolved
Remove portable lighting in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 27 September 2023
Resolution: Master stated lights removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2023
Resolved
Ensure the bottom of the distribution panel at the entrance to the engine room is blanked off.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: blank provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2023
Resolved
Remove or place in a J-box the three (03) dead end wires pointed out during the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: wires removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2023
Resolved
Captain's cabin - place a blank in the opening of the J-box in the overhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 29 August 2023
Resolution: blank added
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 7 August 2023
Resolved
(a) A vessel of more than 19.8 meters (65 feet) in length must carry at least one rescue boat unless the cognizant OCMI determines that:
(1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water;
(2) Recovery of a helpless person can be observed from the operating station; and
(3) The vessel does not regularly engage in operations that restrict its maneuverability. Currently vessel plans to use bow ramp to recover a helpless person, but that may not be ideal due to sea conditions. Provide additional options to recover a helpless person from the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 19 October 2023
Resolution: Conducted satisfactory MOB using jacobs cradle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2021
Resolved
Mount the following J-boxes: upper most weather deck and ER center overhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 23 August 2021
Resolution: received photos showing J-boxes mounted
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 August 2021
Resolved
Ensure EPIRB is float free until new housing is installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 22 September 2021
Resolution: Received photo and email of proper housing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2021
Resolved
Place deadend wires in captain's stateroom head in J-box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 23 August 2021
Resolution: received photo of wires in J-box
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2021
Resolved
Ensure smoke detector in engineer;s sateroom is operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 23 August 2021
Resolution: received photo showing installed smoke detector
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 August 2021
Resolved
ER generator - provide insulation on hot surfaces
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 23 August 2021
Resolution: received photo of installed insulation
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 11 August 2021
Resolved
Provide sewage discharge placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 22 September 2021
Resolution: Received photo of placard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 August 2021
Resolved
Provide emergency escape label in ER "EMERGENCY EXIT, KEEP CLEAR" on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 22 September 2021
Resolution: Received photo of label.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2021
Resolved
E-lights do not come on automatically. Ensure E-lights come on automatically when installed.
Action required: 10 - Deficiency Rectified
Resolved 11 August 2021
Resolution: corrected on the spot, vessel plans to redo electrical in fall 2021 and will make E-lighting meet regulations
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2021
Resolved
Fire pump pressure gauge is inoperable. Renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 23 August 2021
Resolution: received photo of renewed gauge
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 August 2021
Resolved
Vent covers for goosenecks vents for forward port house are missing. Provide covers for vents at next drydock.
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: added
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 11 August 2021
Resolved
Vessel is Oceans Route and is required a MF radio. Vessel only has VHF radio. Install MF radio/sat phone as required by FCC. Vessel restricted to no more than 20 NM from land. 47CFR80.905(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 23 August 2021
Resolution: received statement that SAT phone is installed and certs will be sent
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 August 2021
Resolved
Ensure vessel has FCC Radio Safety Cert and Bridge-to-bridge cert. 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 22 September 2021
Resolution: Received copy of cert.
09 - Working and Living Conditions › 091 - Living Conditions › Messroom (location)
Issued 11 August 2021
Resolved
Ensure stove has brackets to prevent movement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 22 September 2021
Resolution: Received photo of bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 August 2020
Resolved
Vessel to have adequate distress signals onboard for the vessels route and service. *Restricted to daylight operations only*
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 August 2020
Resolved
Stern light was found inoperable. Repair back into working condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 11 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 August 2020
Resolved
Fuel filters in the engine room need to be equipped with an approved flame bowls.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 11 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020
Resolved
The ring buoy light was found not to have a non-corrosive metallic clip.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 24 August 2020
Resolution: Replaced with a non-corrosive metallic clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020
Resolved
Lifejackets and immersion suits are to be properly labeled with quantity near the location of stowage.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 11 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 August 2020
Resolved
Emergency broadcast placard to be posted near the VHF radio.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 11 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Ring life buoy water light had wrong battery light, but was operational. Ensure correct battery is installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 7 June 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 May 2019
Resolved
Ensure valid FCC safety and bridge-to-bridge certs are on board
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2019
Resolved 7 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 May 2019
Resolved
Vessel did not have any alcohol test strips on board. Reviewed requirement for testing within two hours.
Action required: 10 - Deficiency Rectified
Due 31 May 2019
Resolved 7 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 May 2019
Resolved
Provide life jacket donning placards. Post conspicuously.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2019
Resolved 7 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2019
Resolved
#3 (fwd center) generator in engine room raw water sea valve leaks as well as sea strainer (one drip per second).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 7 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2019
Resolved
Vessel drydocked for ABS Loadline renewal and started making repairs without notifying the Coast Guard as required by 46CFR176.665.
Action required: 705 - Other - as specified
Resolved 10 January 2019
Resolution: Recommended a LOW
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 30 May 2018
Resolved
Vessel required to have chlorine tablets on board vessel prior to use/operation of newly installed type II marine sanitation device.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 29 May 2019
Lifesaving › Lifebuoys › Serviceable
Issued 3 May 2018
Resolved
Replace retro-reflective material on ringbouy located near the ramp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 May 2018
Communications › Radio Communications › EPIRB
Issued 3 May 2018
Resolved
Provide current NOAA reregistration for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 May 2018
Lifesaving › Hand Flares › Quantity
Issued 3 May 2018
Resolved
Vessel missing 02 smoke flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 May 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 May 2018
Resolved
Permanently mount fire extinguisher located in paint locker. Extinguisher nozzle is currently being held in place with duck tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 May 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 May 2018
Resolved
ort and Starboard fuel shut offs were found inoperable. Make repairs and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 May 2018
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 May 2018
Resolved
Vessels #2 generator was missing lagging on exhaust piping due to exhaust leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 29 May 2019
Documentation › Certificates/Documents › FCC SSL
Issued 19 July 2017
Resolved
FCC ship radio station authorization has expired. Renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2017
Resolved 3 May 2018
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 19 July 2017
Resolved
Master needs to obtain FCC marine radio operators permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2017
Resolved 3 May 2018
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 28 June 2016
Resolved
Provide FCC bridge to bridge certificate.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 6 July 2016
Lifesaving › Hand Flares › Expired
Issued 28 June 2016
Resolved
Replace expired distress signals.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 20 July 2016
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 June 2016
Resolved
Make repairs to fire detection in engine room.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 20 July 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 June 2016
Resolved
Replace expired alcohol test strips.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 20 July 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 July 2015
Resolved
Vessel Master to receive supervisory signs & symptons training.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 28 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2015
Resolved
Dead end or properly terminate wires beneath bridge console.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 28 June 2016
Personnel › Training › Familiarization Training
Issued 13 July 2015
Resolved
Update emergency procedures to vessel specific operations regarding use of ramp door and train crew.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 28 June 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 July 2015
Resolved
Renew outdated light list & coast pilot.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 28 June 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 July 2015
Resolved
Conduct underway MOB and Fire Drill w/ USCG onboard.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 28 June 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 19 June 2012
Resolved
Demonstrate proper operation of replacement engine prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2012
Resolved
Provide alcohol test strips for each member of crew.
Due 16 May 2012
Resolved 29 May 2012
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 2 May 2012
Resolved
Provide proof of first aid/CPR certification.
Due 1 July 2012
Resolved 18 June 2012
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 May 2012
Resolved
Replace/repair port L/O gauge on bridge.
Due 16 May 2012
Resolved 29 May 2012
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 May 2012
Resolved
Provide proof of required EPIRB testing.
Due 16 May 2012
Resolved 29 May 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2012
Resolved
Replace/repair anchor light.
Due 16 May 2012
Resolved 29 May 2012
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 2 May 2012
Resolved
Replace batteries in life jacket lights.
Due 16 May 2012
Resolved 29 May 2012
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 May 2012
Resolved
Provide 14 type 1 pfd's.
Due 16 May 2012
Resolved 29 May 2012
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2012
Resolved
Replace retro reflective tape on all ring buoys.
Due 16 May 2012
Resolved 29 May 2012
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2012
Resolved
Replace/repair aft ring buoy.
Due 16 May 2012
Resolved 29 May 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2012
Resolved
Replace batteries in ring buoy light.
Due 16 May 2012
Resolved 29 May 2012
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 2 May 2012
Resolved
Secure f/o transfer boost pump in E/R.
Due 16 May 2012
Resolved 29 May 2012
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 May 2012
Resolved
Replace electrical receptacle on fwd center E/R bulkhead.
Due 16 May 2012
Resolved 29 May 2012
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 2 May 2012
Resolved
Hard wire stbd E/R emergency lighting.
Due 16 May 2012
Resolved 29 May 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 May 2012
Resolved
Provide serviced fire extinguisher for paint locker.
Due 16 May 2012
Resolved 29 May 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 5 October 2010
Resolved
Port MDE threw rod/cracked block
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2011
Resolution: In-kind engine installed, tested sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 April 2009
Resolved
Provide current COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Communications › Radio Communications › EPIRB
Issued 22 April 2009
Resolved
Provide proof of current NOAA registration for EPIRB.
Due 22 April 2009
Resolved 22 April 2009
Lifesaving › Inflatable Liferafts › Not on Board
Issued 22 April 2009
Resolved
Vessel is restricted to carrying no more than 10 persons on board (POB) due to only having a 10 person life raft. Vessel must have 100% lifesaving.
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Vsl has 14 person liferaft installed.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 22 April 2009
Resolved
Properly mark vessel name on all PFD's.
Action required: 705 - Other - as specified
Resolved 22 April 2009
Stability › Unintentional Flooding › General
Issued 22 April 2009
Resolved
Properly cap overboard line in way of STBD side FWD engine room.
Action required: 705 - Other - as specified
Resolved 22 April 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 April 2009
Resolved
Properly support batteries and cover to protect from falling objects (3 ea).
Action required: 705 - Other - as specified
Resolved 22 April 2009
Electrical › Electric Supply System (service) › Cable
Issued 24 March 2005
Resolved
Required correct installation of wiring to the hot water heaters
Condition: Improper Installation
Due 24 April 2005
Resolved 3 April 2005
Documentation › Certificates/Documents › International Load Line Certificate
Issued 24 March 2005
Resolved
Annual survey was not conducted. Required ABS survey and endorsement to certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2005
Communications › Radio Communications › EPIRB
Issued 24 March 2005
Resolved
Registration for EPIRB was not current
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 March 2005
Resolved
Repair port side engine room bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 March 2005
Resolved
Repair stern navigation light and make repairs to navigation light panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 March 2005
Resolved
Required updated copy of Tidal and Current tables.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2005
Lifesaving › Hand Flares › Storage
Issued 24 March 2005
Resolved
Required storage container for "distress signals" not on board and properly marked.
Action required: 705 - Other - as specified
Due 24 April 2005
Resolved 25 April 2005
Communications › Alarms/Indicators › General Alarm
Issued 24 March 2005
Resolved
Repair rotating red light in port side engine room used for the general alarm system.
Due 24 April 2005
Resolved 25 March 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 24 March 2005
Resolved
Repair starboard side bow ramp winch.
Due 24 April 2005
Resolved 29 March 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 March 2005
Resolved
Employer required to provide proof of crewmembers enrollment in a drug testing program
Due 24 April 2005
Resolved 29 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 June 2004
Resolved
Provide proof of servicing of all portable extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 9 June 2004
Resolution: Service completed, new ext to replace out of date hydro.
Operations/Management › Lifesaving
Issued 8 June 2004
Resolved
Prove service of Inflatable raft. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 9 June 2004
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 8 June 2004
Resolved
Repair hole in Fuel vent containment at aft stabd main deck fuel vent. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2004
Resolved 22 April 2009
Fire Fighting › Ventilation Systems
Issued 19 August 2003
Resolved
REPAIR P/S FWD ER SUPPLY AND AFT ER NATURAL VENT CLOSURES TO CLOSE PROPERLY. LEGACY COMPONENT DESC: Duct Hatches
Due 18 September 2003
Resolved 19 September 2003
Resolution: Vents repaired & operate correctly
Electrical › Electrical Distribution System (service)
Issued 19 August 2003
Resolved
REMOVE OR REPAIR ELECTRICAL CABINET ON PORT MAIN DECK. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 18 September 2003
Resolved 19 September 2003
Resolution: Cabinet removed
Electrical › Electrical Distribution System (service)
Issued 19 August 2003
Resolved
PROVIDE CAPS FOR STUFFING TUBES AT PORT ER HATCH & SHORETIE PLUG. LEGACY COMPONENT DESC: Shore Connection Box
Due 18 September 2003
Resolved 19 September 2003
Resolution: Capped
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 19 August 2003
Resolved
RECONNECT DRYER DUCT BEFORE USING LEGACY COMPONENT DESC: Laundry
Due 19 September 2003
Resolved 19 September 2003
Resolution: Tagged out/OOC
Stability › Watertight Integrity
Issued 19 August 2003
Resolved
ADJUST STBD LAUNDRY HATCH DOGS LEGACY COMPONENT DESC: Hatch
Due 18 September 2003
Resolved 19 September 2003
Resolution: Adjusted
Documentation › Logs/Records
Issued 19 August 2003
Resolved
PROVIDE PRE-EMPLOYMENT RESULTS FOR JOHN DEACON LEGACY COMPONENT DESC: Drug Test Records
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2004
Resolution: Individual no longer working.
Documentation
Issued 18 June 2001
Resolved
Provide valid Loadline certificate on board.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Lifesaving
Issued 18 June 2001
Resolved
Replace 2 deteriorated ring buoys.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Navigation
Issued 18 June 2001
Resolved
Install chaffing gear hydraulic hoses in lazarette.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Electrical
Issued 18 June 2001
Resolved
Remove dead end wire aft weather deck.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Fire Fighting
Issued 18 June 2001
Resolved
Replace door for aft fire hose locker.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Fire Fighting
Issued 18 June 2001
Resolved
Provide diagram in area of pump to show operation of fire system.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Lifesaving
Issued 18 June 2001
Resolved
remove door stop on heater in galley.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Fire Fighting
Issued 18 June 2001
Resolved
Provide smoke detector in engineers stateroom.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Deck/Cargo
Issued 18 June 2001
Resolved
Properly repair hydraulic line in lazarette for aft anchor winch.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Documentation
Issued 18 June 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 18 June 2001
Resolved
Replace plastic dryer vent hose with metal duct.
Condition: Unknown
Due 22 June 2001
Resolved 26 June 2001
Documentation
Issued 10 May 2000
Resolved
CONDUCT ANNUAL LOADLINE SURVEY BY CLASS. LIMITED TO INSIDE BOUNDARY LINE UNTIL COMPLETE.
Condition: Unknown
Due 17 May 2000
Resolved 20 June 2000
Construction/Loadline
Issued 10 May 2000
Resolved
DOUBLE CLAMP ALL RAW WATER FLEX HOSE FITTINGS.
Condition: Unknown
Due 18 May 2000
Resolved 20 June 2000
Documentation
Issued 10 May 2000
Resolved
PROVIDE CURRENT DRUG PROGRAM CONTRACT.
Condition: Unknown
Due 18 May 2000
Resolved 20 June 2000
Fire Fighting
Issued 10 May 2000
Resolved
PROVE PROPER OPERATION OF FIRE/SMOKE DETECTION SYSTEM, (4 DETECTORS)
Condition: Unknown
Due 18 May 2000
Resolved 20 June 2000
Lifesaving
Issued 10 May 2000
Resolved
CONDUCT U/W DRILLS
Condition: Unknown
Due 18 May 2000
Resolved 20 June 2000
Fire Fighting
Issued 10 May 2000
Resolved
REPLACE SUICIDE NOZZLES WITH DUAL PURPOSE NOZZLE ON ALL 3 STATIONS.
Condition: Unknown
Due 18 May 2000
Resolved 20 June 2000
Engineering
Issued 25 June 1999
Resolved
Install proper f/o hosing for hot water boiler.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Electrical
Issued 25 June 1999
Resolved
Repair or remove overhead florescent light in laundry room.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Construction/Loadline
Issued 25 June 1999
Resolved
Permanently seal port ventilation void cover.
Condition: Unknown
Due 27 June 1999
Resolved 2 July 1999
Deck/Cargo
Issued 25 June 1999
Resolved
Conduct annual crane inspection/certification.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Construction/Loadline
Issued 13 April 1998
Resolved
Remove flammable bulkhead penetration filler material & replace with non- flammable material. Penetration in fwd bulkhead of e/r on port side (at eyelevel). Replacement to make bulkhead watertight.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Documentation
Issued 13 April 1998
Resolved
Provide valid Certificate of Documentation.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Lifesaving
Issued 14 May 1997
Resolved
Provide evidence that the master is enrolled in chemical testing program prior to 30MAY97.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Engineering
Issued 13 May 1995
Resolved
Provide test data from qualified 3rd party or test engine room compressed air receiver relief valve in presence of Coast Guard marine inspector.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Engineering
Issued 13 May 1995
Resolved
Provide hard piping system for forward deck generator fuel day tank supply and overflow. Do not use the flexible hose system which is installed.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Deck/Cargo
Issued 13 May 1995
Resolved
Provide crane testing as per 46 CFR 91.37 for 2 forward cargo cranes. Do_x001C_ not use cranes until testing is approved.
Condition: Unknown
Due 26 June 1995
Resolved 28 June 1995
Construction/Loadline
Issued 13 May 1995
Resolved
Install suitable strainer on lazarrette bilge suction. Size to be not less than 3 times the area of the pipe.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Electrical
Issued 13 May 1995
Resolved
Install proper circuit protection for forward deck generator 24VDC electricfuel transfer pump in engine room. Provide electrical plan of system for approval. Plan to include wire size, wire type, length of conductor, circuit protection and load. Do not use until system has been approved.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Lifesaving
Issued 13 May 1995
Resolved
Provide proper storage for paint and miscellaneous flammables in heating boiler room and starboard bow storage locker.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Construction/Loadline
Issued 13 May 1995
Resolved
Repair high bilge level audible alarm on bridge.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Documentation
Issued 13 May 1995
Resolved
Provide FCC operators permit for SSB radio.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Electrical
Issued 13 May 1995
Resolved
Provide permanent electrical wiring system for forward deck generator battery charger.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Electrical
Issued 13 May 1995
Resolved
Provide permanent electrical wiring system for starboard electric submersible bilge pump in engine room.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Navigation
Issued 13 May 1995
Resolved
Provide up to date tide and tidal current tables.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Engineering
Issued 13 May 1995
Resolved
Provide approved fuel hose and fittings for forward deck generator fuel return to day tank. Do not use generator until approved hose is installed.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Documentation
Issued 13 May 1995
Resolved
Provide waste management plan and log.
Condition: Unknown
Due 5 June 1995
Resolved 6 June 1995
Construction/Loadline
Issued 11 May 1995
Resolved
Make permanent repairs to bottom shell and internal structural members in way of aft (main) starboard fuel tank to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Electrical
Issued 6 July 1994
Resolved
REPLACE MISSING 24VDC EMERGENCY LIGHT IN ENGINE ROOM.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Lifesaving
Issued 6 July 1994
Resolved
PROVIDE 90' OF LINE ON TWO RING BOUYS.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Electrical
Issued 6 July 1994
Resolved
PROVIDE NONCORROSIVE TRAYS FOR LEAD-ACID BATTERIES IN ENGINE ROOM.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Fire Fighting
Issued 6 July 1994
Resolved
PROVIDE A DISCHARGE PRESSURE GAUGE FOR THE FIRE PUMP.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Deck/Cargo
Issued 6 July 1994
Resolved
RECONNECT AFT ANCHOR TO CABLE.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Electrical
Issued 6 July 1994
Resolved
PROVIDE GLOBES AND GUARDS ON LIGHTS IN DECK STORAGE COMPARTMENTS, ENGINE ROOM AND STEERING COMPARTMENT.
Condition: Unknown
Due 20 July 1994
Resolved 12 July 1994
Documentation
Issued 6 July 1994
Resolved
POST CERTIFICATE OF INSPECTION AND STABILITY LETTER UNDER GLASS IN THE PILOT HOUSE.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Navigation
Issued 6 July 1994
Resolved
PROVIDE CURRENT (UP TO DATE) TIDES/CURRENT TABLES, COAST PILOT AND REQURIEDPUBLICATIONS. THIS ITEM IS TO BE CORRECTED PRIOR TO VESSEL SAILING.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Lifesaving
Issued 6 July 1994
Resolved
PROVIDE 1 ADDITIONAL ADULT LIFE JACKET AND LIGHTS FOR ALL IMMERSIONS SUITS.
Condition: Unknown
Due 6 July 1994
Resolved 12 July 1994
Electrical
Issued 6 July 1994
Resolved
PERMANENTLY AND PROPERLY WIRE THE FORWARD WATER PUMP, REMOVING THE TEMPORARY CIRCUIT.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Fire Fighting
Issued 6 July 1994
Resolved
PROVIDE MARINE BRACKET AND MOUNT THE FIRE EXTINGUISHER IN THE LOWER BUNK ROOM.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Lifesaving
Issued 6 July 1994
Resolved
PROVIDE ADEQUATE RELIEF PIPING FOR THE HOT WATER TANK RELIEF VALVES.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Engineering
Issued 6 July 1994
Resolved
MAKE TIGHT THE FLAME SCREEN ON THE MAIN STARBOARD FUEL OIL TANK.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Lifesaving
Issued 6 July 1994
Resolved
PROVIDE AND ATTACH AN ACCEPTABLE WATER LIGHT TO TWO RING BOUYS. (CG APP NO. 160.010 REQUIRED)
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Lifesaving
Issued 6 July 1994
Resolved
PROVE VESSEL SYSTEMS WITH THE VESSEL UNDERWAY TO THE SATISFACTION OF THE ATTENDING INSPECTOR.
Condition: Unknown
Due 6 July 1994
Resolved 12 July 1994
Accommodation/Occupational Safety
Issued 6 July 1994
Resolved
PROVIDE AN ACCEPTABLE RELIEF VALVE ON THE AIR RECEIVER IN THE ENGINE ROOM.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Accommodation/Occupational Safety
Issued 6 July 1994
Resolved
PROVIDE A SHUT OFF VALVE ON THE OUTLET OF THE AIR RECEIVER.
Condition: Unknown
Due 24 July 1994
Resolved 12 July 1994
Accommodation/Occupational Safety
Issued 6 July 1994
Resolved
ADJUST THE CUTOUT POINT OF THE AIR COMPRESSOR TO SHUT THE COMPRESSOR OFF BELOW THE MARKED WORKING PRESSURE ON THE AIR RECEIVER.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Fire Fighting
Issued 6 July 1994
Resolved
CONNECT FIRE HOSES TO FIRE STATIONS AND PROVIDE SPANNER WRENCHES ON EACH HOSE STATION.
Condition: Unknown
Due 6 July 1994
Resolved 12 July 1994