Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)30.0 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE BOAT SHOP · COEUR D'ALENE, ID, UNITED STATES · built 1991
Hull materialWood
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portCOEUR D'ALENE, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
26 May 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8383018
9 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8347286
16 June 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151455
3 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7926583
18 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694357
23 May 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7471811
25 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7212504
2 February 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134596
15 July 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001232
6 May 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949192
21 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6690033
3 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405248
17 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142573
2 August 2016
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5980093
3 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5867829
18 February 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816258
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 June 2024
Resolved
The owner or managing operator must provide satisfactory evidence of required servicing for fixed and portable fire extinguishers. Equipment hasn't been serviced since 2022.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 4 September 2024
Resolution: Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024
Resolved
A positive shutoff valve shall be installed at the hull penetration. The bilge pump discharge was found without required valve. Due at next DDX.
Action required: 705 - Other - as specified
Resolved 2 April 2026
Resolution: Received pictures attesting to installation of shutoff valve
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024
Resolved
The ring life buoy was found with improper stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 10 September 2024
Resolution: Def cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 May 2021
Resolved
Label fuel shut off valve locations as required by 46 CFR 185.608.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 14 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2021
Resolved
Provide 03 Fire buckets all with lanyards attached (only 1 fire bucket on board) .
46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 14 June 2021
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 May 2021
Resolved
Complete and log fire, man overboard and abandon ship drills as required for all vessel operators.
46 CFR 185.520
46 CFR 185.524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 14 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020
Resolved
Provide docuementation showing enrollment in Drug and Alcohol testing program in compliance with regulation.
46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 25 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2020
Resolved
Replace expired flares on board vessel with approved type in quantitiy required.
46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 23 July 2020
Resolution: Picture of new flares provided.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 17 May 2017
Resolved
Fume detection system was inoperable. Vessel must prove operation of system to the satisfaction of attending Marine Inspector IAW 46CFR182.480.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Received Video from Vessels Rep [name withheld] proving proper operation of fume detection system.
Engineering › Bilge Water Management System › Not Operational
Issued 17 May 2017
Resolved
Indicator for automatic bilge pump high level alarm was inoperable. Vessel must prove operation of system to the satisfaction of attending Marine Inspector IAW 46CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2017
Resolution: Attended vessel and witnessed proper operation of bilge high level alarm.
Lifesaving › Hand Flares › Expired
Issued 17 May 2017
Resolved
Flares onboard the vessel were expired replace flares IAW 46CFR180.68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Received photo of newly purchased flares from vessel representative [name withheld] with experation dates of August 2020.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2017
Resolved
The stern navigation light was not operable at time of inspection, repair replace IAW 46CFR183.420.
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: Attended vessel and witnessed proper operation of stern navigation light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2017
Resolved
Replace expired contents of first aid kit IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 24 May 2017
Resolution: Received notification that new CG approved first aid kit was purchased and placed into service.
Construction/Loadline › Hull › Hull Plating
Issued 2 August 2016
Resolved
Hull IWO port side fwd was holed causing vsl to flood. Repair to original scantling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2016
Resolution: Hull planking replaced/repaired and vsl tested sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 20 May 2016
Resolved
Fume detection system was found to be inopperable. Vessel must prove proper opperation of fume detection system to the satisfaction of attending Marine Inspector. 46CFR182.480
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2016
Resolution: Failure was a result of the sensor not functioning. Sensor was replaced, Vessels Rep [name withheld] sent video of proper opperation of fume detection system to the satisfaction of attending Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 20 May 2016
Resolved
Automatic Bilge pump indicator light was inoperable. Replace in kind to the satisfaction of attending Maring Inspector. 46CFR182.530
Due 27 May 2016
Resolved 20 May 2016
Resolution: Replaced bulb, proved proper opperation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 May 2016
Resolved
Ring buoy light was found to be inopperable. repair of replace in kind to the satisfaction of attending Marine Inspector.
Due 27 May 2016
Resolved 20 May 2016
Resolution: Replaced battery, proved proper opperation of light.
Lifesaving › Hand Flares › Quantity
Issued 20 May 2016
Resolved
It was found that the vessel had and insufficent number of flares, and those that were onboard were expired. Replace in kind to the satisfaction of attending Marine Inspector.
Due 27 May 2016
Resolved 20 May 2016
Resolution: Vessel Rep was able to produce replacements of proper quantity from company storage.