EAGLE is a 1991 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2026, along with 18 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
1991
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

361706
Flag
UNITED STATES
Maury page id
psix-361706

Documentation record

Registered dimensions (L × B × D)30.0 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE BOAT SHOP · COEUR D'ALENE, ID, UNITED STATES · built 1991
Hull materialWood
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portCOEUR D'ALENE, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

26 May 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8383018
9 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8347286
16 June 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151455
3 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7926583
18 May 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694357
23 May 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7471811
25 May 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7212504
2 February 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134596
15 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001232
6 May 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949192
21 May 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6690033
3 May 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405248
17 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142573
2 August 2016 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5980093
3 May 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5867829
18 February 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816258

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 June 2024 Resolved
The owner or managing operator must provide satisfactory evidence of required servicing for fixed and portable fire extinguishers. Equipment hasn't been serviced since 2022.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 4 September 2024
Resolution: Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024 Resolved
A positive shutoff valve shall be installed at the hull penetration. The bilge pump discharge was found without required valve. Due at next DDX.
Action required: 705 - Other - as specified
Resolved 2 April 2026
Resolution: Received pictures attesting to installation of shutoff valve
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024 Resolved
The ring life buoy was found with improper stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 10 September 2024
Resolution: Def cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 May 2021 Resolved
Label fuel shut off valve locations as required by 46 CFR 185.608.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 14 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2021 Resolved
Provide 03 Fire buckets all with lanyards attached (only 1 fire bucket on board) . 46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 14 June 2021
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 May 2021 Resolved
Complete and log fire, man overboard and abandon ship drills as required for all vessel operators. 46 CFR 185.520 46 CFR 185.524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 14 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020 Resolved
Provide docuementation showing enrollment in Drug and Alcohol testing program in compliance with regulation. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 25 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2020 Resolved
Replace expired flares on board vessel with approved type in quantitiy required. 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 23 July 2020
Resolution: Picture of new flares provided.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 17 May 2017 Resolved
Fume detection system was inoperable. Vessel must prove operation of system to the satisfaction of attending Marine Inspector IAW 46CFR182.480.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Received Video from Vessels Rep [name withheld] proving proper operation of fume detection system.
Engineering › Bilge Water Management System › Not Operational
Issued 17 May 2017 Resolved
Indicator for automatic bilge pump high level alarm was inoperable. Vessel must prove operation of system to the satisfaction of attending Marine Inspector IAW 46CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2017
Resolution: Attended vessel and witnessed proper operation of bilge high level alarm.
Lifesaving › Hand Flares › Expired
Issued 17 May 2017 Resolved
Flares onboard the vessel were expired replace flares IAW 46CFR180.68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Received photo of newly purchased flares from vessel representative [name withheld] with experation dates of August 2020.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2017 Resolved
The stern navigation light was not operable at time of inspection, repair replace IAW 46CFR183.420.
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: Attended vessel and witnessed proper operation of stern navigation light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2017 Resolved
Replace expired contents of first aid kit IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 24 May 2017
Resolution: Received notification that new CG approved first aid kit was purchased and placed into service.
Construction/Loadline › Hull › Hull Plating
Issued 2 August 2016 Resolved
Hull IWO port side fwd was holed causing vsl to flood. Repair to original scantling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2016
Resolution: Hull planking replaced/repaired and vsl tested sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 20 May 2016 Resolved
Fume detection system was found to be inopperable. Vessel must prove proper opperation of fume detection system to the satisfaction of attending Marine Inspector. 46CFR182.480
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2016
Resolution: Failure was a result of the sensor not functioning. Sensor was replaced, Vessels Rep [name withheld] sent video of proper opperation of fume detection system to the satisfaction of attending Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 20 May 2016 Resolved
Automatic Bilge pump indicator light was inoperable. Replace in kind to the satisfaction of attending Maring Inspector. 46CFR182.530
Due 27 May 2016
Resolved 20 May 2016
Resolution: Replaced bulb, proved proper opperation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 May 2016 Resolved
Ring buoy light was found to be inopperable. repair of replace in kind to the satisfaction of attending Marine Inspector.
Due 27 May 2016
Resolved 20 May 2016
Resolution: Replaced battery, proved proper opperation of light.
Lifesaving › Hand Flares › Quantity
Issued 20 May 2016 Resolved
It was found that the vessel had and insufficent number of flares, and those that were onboard were expired. Replace in kind to the satisfaction of attending Marine Inspector.
Due 27 May 2016
Resolved 20 May 2016
Resolution: Vessel Rep was able to produce replacements of proper quantity from company storage.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.