Records from 1991 to 2022. Most recent: inspection, 2 March 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifeboat › Hull
Issued 22 August 2006
Resolved
Port side lifeboat has a 1/4" breach in hull above waterline at fender. Make proper repairs to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2006
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 June 2006
Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge.
33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Due 26 July 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04444 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 June 2006
Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam COTP zone
Due 26 July 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04444 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 July 2005
Resolved
Repair spliced electrical wiring for radio base station.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2005
Resolved
Electrical wiring in berthing spaces are in an unsafe condition. Wiring are to accomodate portable electronics.
Due 18 July 2005
Resolved 22 November 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 July 2005
Resolved
Ensure all lights attached to life buoys are operatikonal.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 July 2005
Lifesaving › Immersion Suits › General
Issued 13 July 2005
Resolved
Immersion suit adhesive for flotation dried and coming apart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2005
Lifesaving › Inflatable Liferafts › Markings
Issued 13 July 2005
Resolved
Operating instructions not posted for life raft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2005
Engineering › Fuel Oil Service System › Piping
Issued 11 March 2004
Resolved
Repair minor fuel oil leaks around valves and fittings. LEGACY COMPONENT DESC: Valve
Action required: 15 - Rectify deficiencies by next port
Resolved 9 September 2004
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 11 March 2004
Resolved
Remove combustible materials behind electrical panel in control room.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 9 September 2004
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 28 July 2002
Resolved
Properly calibrate the port and starboard bridge wing gyro compass repeaters.
Action required: 15 - Rectify deficiencies by next port
Due 29 July 2002
Resolved 31 July 2002
Resolution: Verified repeaters were properly calibrated prior to the vessel''s departure from port.
Navigation
Issued 16 January 2001
Resolved
Vessel entered Pago Pago Harbor without a properly operating gyrocompass.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Navigation
Issued 16 January 2001
Resolved
The person directing the movement of the vessel did not report or cause to be reported the non-operational status of gyro compass to the nearest Captain of the Port as soon as possible.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Documentation
Issued 16 January 2001
Resolved
The original IOPP Certificate was not onboard the vessel. MARPOL Annex I, Reg. 7.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Documentation
Issued 16 January 2001
Resolved
The SOLAS Safety Radio Certificate did not have the original Form R onboard. SOLAS 74, CH I, Reg. 14.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Lifesaving
Issued 16 January 2001
Resolved
The vessel did not conduct an adequate abandon ship drill. SOLAS 74, CH III, Reg. 18.3.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 16 January 2001
Resolved
The stbd lifeboat releasing gear was inoperable. SOLAS 74, CH III, Reg. 15and 19.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 16 January 2001
Resolved
The stbd lifeboat engine is inoperable. SOLAS 74, CH III, Reg. 41.6.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 16 January 2001
Resolved
Fire extinguisher was missing from the stbd lifeboat. SOLAS 74, CH III, Reg. 11.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Fire Fighting
Issued 16 January 2001
Resolved
The fire pump housing leaked profusely. SOLAS 74, CH II-2, Reg. 4.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Documentation
Issued 16 January 2001
Resolved
SOLAS training manual was not in a language understood by all crewmembers. SOLAS 74, CH II, Reg. 18.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Lifesaving
Issued 16 January 2001
Resolved
Several items from the port lifeboat were missing. SOLAS 74, CH III, Reg. 11.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 16 January 2001
Resolved
Provide documentation the stbd lifeboat capacity has not been reduced because of large box of provisions. SOLAS 74, CH III, Reg. 41.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Unknown
Issued 16 January 2001
Resolved
The vessels Loadline was not marked in contrasting colors on the side of the hull. ICLL Annex I, Reg. 8.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 16 January 2001
Resolved
The Life Rings did not have adequate retroreflective tape.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Navigation
Issued 16 January 2001
Resolved
The Coast Pilot, sailing directions, tide tables and rules of the road weremissing from the vessel.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Lifesaving
Issued 16 January 2001
Resolved
The abandoned ship and fire drills were not being logged. USCG unable to verify if drills were being conducted. SOLAS 74, CH III, Reg. 18.5.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Lifesaving
Issued 16 January 2001
Resolved
Ensure all blocks on the lifeboat davits are operational. SOLAS 74, CH III, Reg. 19.2.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Documentation
Issued 16 January 2001
Resolved
The SOLAS Safety Equipment Certificate did not indicate the proper vessel gross tonnage. SOLAS 74, CH I, Reg. 14.
Condition: Unknown
Due 16 January 2001
Resolved 28 July 2002
Electrical
Issued 24 April 2000
Resolved
Replace light covers throughout ship.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Electrical
Issued 24 April 2000
Resolved
Provide cover for light in starboard engineering workshop.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 24 April 2000
Resolved
Make watertight doors watertight.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Accommodation/Occupational Safety
Issued 24 April 2000
Resolved
Provide grease trap in galley vent.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Accommodation/Occupational Safety
Issued 24 April 2000
Resolved
Provide medicines that are not expired.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 24 April 2000
Resolved
Provide retroreflective tape for port side lifeboat.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 24 April 2000
Resolved
Make quick releasing life rings on bridge quick releasing.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Navigation
Issued 24 April 2000
Resolved
Correct chart for Pago Pago Harbor.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Documentation
Issued 24 April 2000
Resolved
Provide chief officer's license appropriate for size and type of vessel.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Documentation
Issued 24 April 2000
Resolved
Provide evidence of crewmember's certificates.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 24 April 2000
Resolved
Conduct fire drill to satisfaction of USCG marine inspector.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 24 April 2000
Resolved
Prove proper operation of fire/bilge/ballast pump and provide alternate means of providing water to fight a fire if both pumps in engine room were put out of commision.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 24 April 2000
Resolved
Renew wasted port lifeboat releasing hook post.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 24 April 2000
Resolved
Provide air bottles and spare air bottles for fireman's outfit breathing apparatus.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Unknown
Issued 24 April 2000
Resolved
Remove oil from bilge of starboard lifeboat.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Accommodation/Occupational Safety
Issued 7 January 1999
Resolved
Soft patch IWO sea water piping leading to crews head located in accomodation quarters/poopdk.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Documentation
Issued 7 January 1999
Resolved
update fire control plans to reflect correct number of fire control plans o/b.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Documentation
Issued 7 January 1999
Resolved
Vessel missing SOLAS training manual.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 7 January 1999
Resolved
Excessive combustible materials in paint locker.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Deck/Cargo
Issued 7 January 1999
Resolved
Fuel vent fixed containment missing mechanical plugs.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Fire Fighting
Issued 7 January 1999
Resolved
portable fire extinguisher in No.2 winch house not accessible.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Fire Fighting
Issued 7 January 1999
Resolved
Fire screen door leading from engine room into galley unable to close. Repair so it secures.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Electrical
Issued 7 January 1999
Resolved
Missing light covers for light bulbs in galley.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 7 January 1999
Resolved
CO2 room used for storage. Remove all stored boxes.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 7 January 1999
Resolved
Washing machine not properly stored.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 7 January 1999
Resolved
Bridge wings ring life buoys not arranged for quick release.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 7 January 1999
Resolved
All ring life buoys need replacement retro-reflective tapes.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Accommodation/Occupational Safety
Issued 7 January 1999
Resolved
Stair ladder leading from boat deck to fantail heavily corroded; need to berepaired.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Fire Fighting
Issued 7 January 1999
Resolved
One of fireman's outfit loosing fire retard material; repair or replace.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Construction/Loadline
Issued 7 January 1999
Resolved
Seized dogs to No.1 winch house WTD.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Fire Fighting
Issued 7 January 1999
Resolved
Unsat fire fighting drills.
Condition: Unknown
Due 30 January 1999
Resolved 20 March 1999
Fire Fighting
Issued 7 January 1999
Resolved
Missing one fireman's outfit.
Condition: Unknown
Due 30 January 1999
Resolved 20 March 1999
Documentation
Issued 7 January 1999
Resolved
Minimum Safe Manning document invalid for current voyage. Vsl sailed beyond limitations of area of voyage.
Condition: Unknown
Due 30 January 1999
Resolved 20 March 1999
Lifesaving
Issued 7 January 1999
Resolved
Officer in charge of navigation watch lack english proficiency to communicate with multi-national crew o/b vessel.
Condition: Unknown
Due 30 January 1999
Resolved 20 March 1999