Records from 1991 to 2020. Most recent: inspection, 28 January 2020.
Inspection history · 49
28 January 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6897829
26 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6724466
22 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6452118
6 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6182236
21 February 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6091594
4 February 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6082683
8 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5902091
8 June 2015
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5150160
16 June 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4898016
31 August 2013
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4704775
10 October 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4465257
28 September 2012
Damage Survey · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4452448
26 September 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4454644
22 March 2012
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4269516
9 March 2012
Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4268881
4 January 2010
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3658598
5 July 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3535538
29 June 2009
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3521211
21 October 2008
Annual Inspection · Plan Review "T" Boat
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3628739
12 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3271991
9 July 2008
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3262788
9 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3271744
4 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3267940
25 May 2008
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3217792
25 May 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3219544
21 May 2008
COI Inspection · Construction Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3204589
6 June 2006
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2673274
20 April 2006
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2629145
23 May 2002
Administrative Inspection
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1619808
7 December 2001
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1076929
4 December 2001
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1076510
5 June 2001
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1462975
26 April 2001
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456002
28 July 1998
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1130432
29 December 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 65819
21 August 1997
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120489
14 November 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871751
7 November 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876583
26 August 1994
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1436904
15 September 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837244
22 June 1993
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154028
16 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 963147
16 June 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1135205
7 August 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957978
5 August 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 939871
22 July 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1269113
11 September 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247452
20 August 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945559
7 May 1991
Plan Review "T" Boat · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 906419
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2017
Resolved
Replace battery in Life Ring light (FWD)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 June 2017
Resolution: Received via email pictures of the above deficiency corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 22 March 2017
Resolved
Both Life Ring Buoys have the wrong reflective tape. Renew with SOLAS Retro-reflective tape. Tape completely around life ring X 4.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 June 2017
Resolution: Received via email pictures of the above deficiency corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2017
Resolved
Missing eyewash from First Aid Kit/Replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 June 2017
Resolution: Received via email pictures of the above deficiency corrected.
Electrical › Electric Supply System (service) › Cable
Issued 8 June 2016
Resolved
Extension cord ran from Eng space to Second deck, passing through vent. provide permenant power source to second deck.
Condition: Improper Installation
Due 15 June 2016
Resolved 21 February 2017
Resolution: Properly installed "permanent-style" electrical outlet for the purpose of providing an electrical power source for the second deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 June 2016
Resolved
Light assembly was missing cover, vessel resricted to day light operation only.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 21 February 2017
Resolution: Properly installed cover for the anchor light assembly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 June 2015
Resolved
Hole in deck in the bar area presents an unsafe practice establish means to protect from falls. 46 CFR 176.25-50
Condition: Placed in Improper Service
Due 22 June 2015
Resolved 8 June 2016
Resolution: Vessel repaired and covered hole.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 8 June 2015
Resolved
Windows must be of proper strength to withstand max winds and waves replace cracked port side windows at the operation station. 46 CFR 177.1020
Condition: Improper/Lack of Maintenance
Due 8 July 2015
Resolved 8 June 2016
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 8 June 2015
Resolved
Wood must be suitably insulated from sources of heat. Replace missing insulation over generator. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Due 22 June 2015
Resolved 8 June 2016
Resolution: Insulation has been installed.
Fire Fighting › Fire Hoses › Condition
Issued 16 June 2014
Resolved
Upperdeck Fire Hose had excessive holes and leaking beyond use. Replace with approved UL listed 50'x1.5" hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2014
Resolution: Owner provided a copy of receipt for new hose as well as photo and video prrof of hose in use to the satisfaction of the Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 5 October 2012
Resolved
Vessel not currently in compliance with auxiliary means of steering regulations as starboard engine coupling to newly installed outdrive is inoperable. Vessel is allowed to continue operations until 07OCT12 under the conditions specified in the oowners/operator plan provided to Sector Baltimore on 05OCT12 and owner discretion for favorable operating conditions. After 07OCT12 the vessel shall rema
Action required: 705 - Other - as specified
Due 7 October 2012
Resolved 10 October 2012
Resolution: Replaced both starboard outdrive and coupler. Conducted successful sea trials on outdrive and coupler.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 28 September 2012
Resolved
Vessel not currently in compliance with auxiliary means of steering regulations as starboard engine outdrive is damaged and inoperable. Vessel is allowed to continue operations until 30Sep12 under conditions specified in owners/operator plan provided to Sector Baltimore on 28 Sep 12 and owner discretion for favorable operating conditions. After 30Sep12 the vessel shall remain out of service ..
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 5 October 2012
Resolution: New outdrive installed, however engine coupling not operating properly. New CG-835 issued this date.
Documentation › Certificates/Documents › FCC SSL
Issued 22 March 2012
Resolved
Provide on board a FCC Station License and FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 9 April 2012
Resolved 27 April 2012
Resolution: Received new FCC SafetyCertificate and FCC Station License from O/Op.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 9 July 2008
Resolved
Navigation lights are not in accordance with Inland Navigation Rules 23 and 30 for a vessel under 50 meters in length.
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 9 July 2008
Resolution: Navigation lights are properly installed.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 25 May 2008
Resolved
Permanent repairs are to be made to the stbd engine ensuring transmission will fully engage in fwd & astern gears. Astern propulsion was lost during maneuvering operations. Specific cause is unknown. Repairs are to be made prior to carrying PAX.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2008
Resolution: Tested stbd engine in fwd & astern gear.
Lifesaving
Issued 5 June 2001
Resolved
Mark upper deck for maximum number of passengers permitted IAW 46 CFR 185.602 (g)
Condition: Unknown
Due 12 June 2001
Resolved 13 June 2001
Documentation
Issued 5 June 2001
Resolved
UPDATE CERTIFICATE OF DOCUMENTATION WITH PASSENGER VESSEL ENDORSEMENT.
Condition: Unknown
Due 22 September 2001
Resolved 12 June 2003
Construction/Loadline
Issued 5 June 2001
Resolved
Provide portable bilge pump as required by 46 CFR 182.520 (c)
Condition: Unknown
Due 12 June 2001
Resolved 13 June 2001
Lifesaving
Issued 14 November 1996
Resolved
REPLACE RING BUOY.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Lifesaving
Issued 14 November 1996
Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 7 November 1995
Resolved
PROPERLY SECURE OR REMOVE ALL DEAD-END WIRING UNDERNEATH BOTH UPPER AND LOWER BRIDGE CONSOLES.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Lifesaving
Issued 7 November 1995
Resolved
PROPERLY MARK ALL PERSONAL FLOTATION DEVICE STOWAGE CONTAINERS WITH NUMBER OF ADULT AND CHILD LIFE PRESERVERS.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Documentation
Issued 16 June 1993
Resolved
PROVIDE PAGE 1 OF COI WITH 1992 RE-INSPECTIOIN ENDORSEMENT OR CONDUCT RE- INSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 June 1993
Resolved 24 June 1993
Engineering
Issued 16 June 1993
Resolved
REPAIR/REPLACE AS ORIGINAL STBD OUTDRIVE & BOTHE PROPELLERS. THIS REPAIR TOBE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 June 1993
Resolved 5 July 1993
Navigation
Issued 11 September 1991
Resolved
POST CURRENT COMPASS DEVIATION CARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Documentation
Issued 11 September 1991
Resolved
PROVIDE PROPER DRUG TEST PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Engineering
Issued 11 September 1991
Resolved
PROPERLY SECURE SENDING UNIT TO FUEL TANK.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Accommodation/Occupational Safety
Issued 11 September 1991
Resolved
PROPERLY SECURE COFFEE POT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Documentation
Issued 11 September 1991
Resolved
PROVIDE PROPER FCC STATION LICENSE.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Construction/Loadline
Issued 11 September 1991
Resolved
PROVIDE PROPER SEA-VALVE AT THROUGH HULL FOR MAIN ENGINE COOLING WATER_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Documentation
Issued 11 September 1991
Resolved
PROVIDE AND POST STABILITY LETTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Documentation
Issued 20 August 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Documentation
Issued 20 August 1991
Resolved
CONTACT [name withheld] TO SCHEDULE AND COMPLETE AN INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Lifesaving
Issued 7 May 1991
Resolved
PROVIDE 11 ADDITIONAL ADULT PFD,S. PASSENGER CAPACITY REDUCED TO 38 UNTIL PROVIDED.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Documentation
Issued 7 May 1991
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991