Records from 1991 to 2025. Most recent: inspection, 8 November 2025.
Inspection history · 77
8 November 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8265921
23 June 2025
COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8165469
11 June 2025
Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8157656
22 April 2025
Inclining Experiment
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8118579
22 November 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038458
5 December 2023
Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833937
29 August 2023
Inclining Experiment
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7808837
27 June 2023
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7725376
25 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7700261
14 March 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7650627
23 February 2023
Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7641539
9 June 2022
In-Service Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472965
18 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414119
30 November 2021
DAPI Audit · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7357019
17 November 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7352861
17 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008507
18 June 2020
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974046
24 June 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6780951
16 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760958
1 April 2019
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760831
23 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6566311
11 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6440699
19 April 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394505
19 April 2018
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394534
18 April 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394726
16 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6338223
21 December 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6331467
15 May 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6146258
20 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6107774
13 June 2016
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5906247
21 July 2015
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5197879
23 June 2014
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4896918
23 May 2012
DAPI Audit · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4319164
5 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4268164
10 June 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3232949
24 April 2007
Deficiency Check · MARPOL Annex V Examination · Hull Examination · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2914572
6 June 2006
MTSA Verification · Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2672295
24 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2609274
18 May 2005
Annual Inspection · MARPOL Annex V Examination · Security Plan Review - ASP
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2361041
17 February 2005
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2294775
13 August 2004
MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2164941
10 June 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2094039
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979356
11 June 2003
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2016597
21 March 2003
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1760699
10 September 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1674659
8 May 2002
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1614449
23 April 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1608335
14 March 2002
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1493821
10 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073772
31 August 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1076612
30 May 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1066225
26 April 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1387047
4 April 2001
Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410518
22 March 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441636
19 April 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391016
17 March 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1381507
12 March 1999
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365104
7 May 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1127760
3 April 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788727
7 May 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102272
4 April 1997
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103433
26 March 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1380492
18 April 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861474
11 April 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 851259
7 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170293
18 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151426
25 October 1994
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173238
13 April 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858668
12 May 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834901
19 April 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133100
10 November 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961894
27 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268522
8 April 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261760
10 December 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265540
21 November 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251478
24 May 1991
Plan Review "T" Boat · Initial Construction-Excluding Oversight · COI Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215494
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2025
Resolved
Vsl was missing structural fire protection in the overhead of the engine room by the switch board and distribution panel.
Renew the structural fire protection with an approved type to the satisfaction of the attending marine inspector.
46 CFR 177.10-5(a)
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: installed new SFP.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2025
Resolved
Vsl had dry engine exhaust piping that was not insulated.
Install lagging/insulation over those unprotected exhaust pipes to the satisfaction of the attending MI.
46 CFR 177.10-5(b)
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 8 November 2025
Resolution: new lagging installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2025
Resolved
Bridge and galley portable fire extinguishers were not mounted properly.
Properly mount all fire extinguisher to the satisfaction of the attending MI.
46 CFR 181.30-10
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: mounted properly
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2025
Resolved
Port side main deck amidships wooden door was worn at the bottom.
Replace/install an approved fire door for that space to the satisfaction of the attending MI.
46 CFR 177.10-5(a)
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 8 November 2025
Resolution: wooden door repair with metal kick plate.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 17 September 2025
Resolved
Emergency lighting was missing from the secondary means of escape in the bridal suite and the galley.
Install proper emergency lighting for secondary escape means to the satisfaction of the attending MI.
46 CFR 184.30-4
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: E light installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 June 2025
Resolved
Vsl was missing all charts and publications (coast pilot, light light, tide tables, currents, etc).
Provide all necessary charts and publications to the vsl and route to the satisfaction of the attending MI.
46 CFR 121.420
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: electronic charts and pubs, SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2025
Resolved
Vsl could not preform bilge suction from any space using the fixed installed system.
Vsl is required to show that the fixed bilge system (with 02 pumps) is capable of draining/dewatering all watertight compartments for the satisfaction of the attending MI.
46 CFR 182.25-1
701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Verified proper operation
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2023
Resolved
A Certificate of Inspection is obtained or renewed by making application on Form CG 3752, “Application for Inspection of U.S. Vessel,” to the Coast Guard OCMI of the marine inspection zone in which the inspection is to be made.
The vessel's routes and conditions dot not permit the carriage of passengers in the Sector Jacksonville OCMI zone.
Vessel to submit CG-3752, application for inspection, to local OCMI.
Prior to the carriage of passengers the vessel must complete a New-To-Zone COI inspection to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: COI completed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 March 2023
Resolved
Based upon MSC letter issued on July 13, 2022, vessel must complete either a deadweight survey or incline test to verify lightship characteristics. A stability test procedure must be submitted to MSC for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 August 2023
Resolution: Inclining Experiment was conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2023
Resolved
Vessel has onboard SeaKeeper not approved for operation. Owner/operator must submit electrical plans for Seakeeper to MSC for review and approval prior to use.
Action required: 705 - Other - as specified
Resolved 1 June 2025
Resolution: Vessel submited/received approved updated stability letter.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 March 2023
Resolved
Observed improper installation of overhead longitudinal frame in compartment above where SeaKeeper is installed. Make proper repairs to overhead longitudinal frame.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Observed repair of overhead frame.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2023
Resolved
Provide sign and donning instructions for lifejackets on main deck.
46CFR117.78
46CFR122.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 25 May 2023
Resolution: Donning instructions provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 February 2023
Resolved
Update DER, conduct EAP and drug awareness training.
49CFR40.3
46CFR16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 25 May 2023
Resolution: Records updated.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2023
Resolved
Renew aft port corner broken glass window.
46CFR 116.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2023
Resolved 15 March 2023
Resolution: MI attended vessel and witnessed satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 February 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Bilge system strainer in steering compartment was severely obstructed by mud and marine growth. Clean bilge strainer in steering compartment and check all others.
46CFR119.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Witnessed satisfactory test of new bilge suction from forward peaktank with new bilge strainer install.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 February 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Man hole covers for oil tanks in E/R were removed to use space for storage. Re-install all man hole covers in engine room.
46CFR116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Hatch covers installed to maintain watertight integrity of bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 February 2023
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. One if the lifebuoys on board is missing grab line. Provide three ring buoys in satisfactory condition.
46CFR117.70(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Vessel equipped with 3 life buoys in serviceable condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2021
Resolved
All wiring shall be suitable for marine service. Remove all rope-style lights from the interior of the vessel.
46 CFR 183.10-20
Action required: 10 - Deficiency Rectified
Resolved 30 November 2021
Resolution: Rope-style lights removed in presence of marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 November 2021
Resolved
The power fire pump shall be fitted with a pressure gauge. The pressure gauge does not work.
46 CFR 181.10(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
Resolution: Operations manager sent picture of new gauge.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 30 November 2021
Resolved
Each vessel must meet applicable requirements of subchapter S. According to stability letter, only 75 passengers are authorized on the upper deck.
46 CFR 177.13-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
Resolution: Operations manager sent picture of passenger upper deck limit.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 November 2021
Resolved
Vessel's COI is invalid due to over due annual inspection. Vessel is prohibited from the carriage of passengers until a satisfactory annual inspection is completed.
46 CFR 176.500(1)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 July 2020
Resolved
Vessels operated soley within 20 nautical miles of land msut be equipped with a VHF-DSC radiotelephone installation. Both the port and starboard VHF radios could not send or recieve radio signal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2020
Resolution: witnessed via video installation and proper operation
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 June 2019
Resolved
Remote fuel shut off valve pull cable has failed, repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2019
Resolution: The cable and pull handle was replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2019
Resolved
Provide a cover for the battery box fwd engine room stbd side.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019
Resolved
Removed the dish rack from the front side of the electrical distribution panel in the the galley. The dish rack is preventing the distribution panel from being able to be opened.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 June 2019
Resolved
The galley exhaust fans have oil accumulation of the motor creating a fire hazard, clean.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 April 2019
Resolved
Bottom plate between the keel cooler is corroded. Provide a repair proposal and conduct repairs.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 18 June 2020
Resolution: Attending marine inspectors verified satisfactory repairs completed as per previously approved repair proposal.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 October 2018
Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0) and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 September 2025
Resolution: New AIS installed. AIS broadcasting properly.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 June 2018
Resolved
All vessels bilge high water level alarms were inoperable. Vessel is to prove proper operation to CG Marine Inspector. 46 CFR 119.530. PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Vessel repaired high level alarms.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 June 2018
Resolved
Vessel was unable to provide several documents upon request. Vessel is prove full compliance with DAPI to CG Marine Inspector. 46 CFR 16. PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Vessel provided documents to prove complaince with DAPI
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2018
Resolved
Vessel is to provide CG approved first aid kit. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel had an approved first aid kit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 June 2018
Resolved
Vessel's waterlight lanyard on bridge life buoy is too long. vessel needs to correct length. 46 CFR 117.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel provided waterlight lanyard of correct length
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 11 June 2018
Resolved
Vessels raw water pump for cooling port engine is leaking excessively. Vessel needs to repair. 46 CFR 119.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Raw water pump was repaired and no longer leaking.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 June 2018
Resolved
vessel needs to provide guard for lighting fixture located in the engine room. 46 CFR 120.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: A guard was installed on lighting fixture.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 June 2018
Resolved
Vessel has a 3 amp ground while connected to shore power. Vessel must make a means to eliminate potential for creating a ground. 46 CFR 120.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel no longer had a ground.
Construction/Loadline › Hull › Side Shell
Issued 19 April 2018
Resolved
Vessel must submit approved tow plan to USCG MI prior to movement from Chelsea Pier.
Action required: 10 - Deficiency Rectified
Due 13 June 2018
Resolved 13 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 19 April 2018
Resolved
Vessel must submit technician report and have USCG Marine Inspector witness safe operation of machinery and vessel maneuvering (sea trials) prior to carrying passengers, operating main engines, or any movement in addition to the single tow plan voyage.
Action required: 10 - Deficiency Rectified
Due 13 June 2018
Resolved 27 April 2018
Construction/Loadline › Hull › Side Shell
Issued 19 April 2018
Resolved
Vessel must submit repair plan to USCG for approval for side shell damage prior to repairs. Vessel must have USCG inspect repairs prior to carrying passengers, operating main engines, or any movement in addition to the single tow plan voyage.
Due 13 June 2018
Resolved 13 June 2018
Engineering › Bilge Water Management System › Pump
Issued 15 May 2017
Resolved
1. Prove proper operation of vessels bilge system.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 15 May 2017
Resolved
2. Properly repair identified exhaust leak in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 May 2017
Resolved
3. Properly repair identified port shaft seal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 May 2017
Resolved
4. Prove proper operation of watertight door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2016
Resolved
Repair port MDE exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Flex hose replaced.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 June 2016
Resolved
Repair generator exhaust leak
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Hose clamp replaced.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 June 2016
Resolved
Provide ground detection
Condition: Improper/Lack of Maintenance
Due 13 July 2016
Resolved 17 June 2016
Resolution: Amp meter replaced and operational. Ground lights operating.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 13 June 2016
Resolved
Provide means to inspect/test air receiver.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: System tested.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2016
Resolved
Provide DSC on VHF radios (MMSI #)
Condition: Improper/Lack of Maintenance
Due 13 July 2016
Resolved 17 June 2016
Resolution: DSC provided
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 13 June 2016
Resolved
Provide post casualty drug and alcohol testing procedures.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: Procedures emailed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 June 2016
Resolved
Provide march 2016 MIS report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: MIS report submitted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 June 2014
Resolved
LG01: COI must be posted for observation of passengers.
Due 7 July 2014
Resolved 24 June 2014
Resolution: COI updated and posted for passenger viewing.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 23 June 2014
Resolved
LG02: Correct Station Bill to include emergency categories. Past Station Bill in location in each crew area.
Due 7 July 2014
Resolved 24 June 2014
Resolution: Station Bill was corrected and posted for crew viewing.
Engineering › Pressure Vessel › Weld
Issued 23 June 2014
Resolved
LG03: Air receiver must be hydrostatically or internally inspected prior to use.
Due 7 July 2014
Resolved 24 June 2014
Resolution: Witnessed satisfactory hydrostatic test of air receiver.
Engineering › Pressure Vessel › Relief Valve
Issued 23 June 2014
Resolved
LG04: Replace air receiver relief valve prior to use.
Due 7 July 2014
Resolved 24 June 2014
Resolution: Air receiver relief valve was properly replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2012
Resolved
HA08: Fix broken hand rail as discussed IWO portside entrance door.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel welded broken hand rail. Deficiency cleared.
Engineering › Diesel Engine (auxiliary) › Block
Issued 23 May 2012
Resolved
HA05: Repair crack in jacket water exhaust manifold in forward generator. Prove proper operation (i.e. does not get high temp alarm/shutdown).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Resolution: Vessel installed new exhaust manifold.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 May 2012
Resolved
HA04: Vessel must supply 2 new liferings, 1 with grabline and 1 with waterlight.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel supplied 2 new liferings, 1 with a grabline and 1 with a waterlight.
Construction/Loadline › Hull › Side Shell
Issued 23 May 2012
Resolved
HA07: Vessel has small hole in steering compartment. V-Weld as discussed.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel V-Welded area and there is no longer a hole.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 May 2012
Resolved
HA03: Provide one B-I fire extinguisher on bridge. Current FE is expired.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel has serviceable B-I fire extinguisher on bridge.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 May 2012
Resolved
HA06: Replace fire extinguisher bracket with proper size at top of ladderwell.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel remounted bracket.
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2012
Resolved
HA02: Provide current charts for area of operation.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 7 June 2012
Resolution: Vessel provided acceptable charts for area of operation.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011
Resolved
Vessel failed to submit certification with new AAWPP of 185 lbs. Issued CG-835 reducing total number of persons to 192 (180 passengers).
Action required: 705 - Other - as specified
Resolved 23 May 2012
Resolution: Vessel provided documentation requesting passenger reduction.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 18 May 2007
Resolved
Amidships generator has a pin hole in the coolant reservoir and is leaking. Make permanent repair and prove proper operation of generator to USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Reservoir was welded to repair pin hole leak.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 18 May 2007
Resolved
Double clamp raw water supply flex hose connections on both generators.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2007
Resolved 24 May 2007
Resolution: Additional clamps installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 18 May 2007
Resolved
Double clamp raw water intake flex hose supply for aft generator.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Additional clamp installed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 May 2007
Resolved
Double clamp flex hose wet exhaust supply for starboard exhaust piping (above aft generator).
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Additional clamp installed.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 18 May 2007
Resolved
Secure oil leak on front end of port main engine.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Fitting was tightend to secure leak.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 18 May 2007
Resolved
Replace worn/cut raw water intake hose on starboard main engine.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: New hose installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 May 2007
Resolved
Rescue platform was lost over the side during evolution of man overboard drill. Obtain new rescue platform and conduct man overboard drill in the presence of USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: New platform procured and tested during the man overboard drill that was conducted during the Def Check.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 18 May 2007
Resolved
Permanently mark emergency escape from galley.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Emergency escape marked.
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 May 2007
Resolved
Provide cap for fresh water fill pipe on starboard side.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: New cap procured and installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 18 May 2007
Resolved
Provide three B-II class fire extinguishers onboard to meet 6 required onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2007
Resolved 24 May 2007
Resolution: 3 new extinguishers provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2007
Resolved
Provide one child size life jacket. Number of children allowed onboard is reduced to 25 until this requirement is met.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Extra child sized lifejacket installed.
Lifesaving › Lifebuoys › Stowage
Issued 18 May 2007
Resolved
Repair/replace broken life ring bracket located at pilot house.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: New lifering bracket installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 May 2007
Resolved
Re-stencil life ring buoys with vessel name.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 May 2007
Resolution: Lifering stencilled with the vessels name.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 6 June 2006
Resolved
Install sea rail on stove in galley.
Action required: 705 - Other - as specified
Due 13 June 2006
Resolved 13 June 2006
Resolution: Sea rail installed.
Stability › Weathertight Integrity › General
Issued 6 June 2006
Resolved
Replace cracked windows, port side, aft, second deck and port side amidships.
Action required: 705 - Other - as specified
Due 13 June 2006
Resolved 13 June 2006
Resolution: Both windows replaced.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 May 2005
Resolved
Provide proof of required annual D&A supervisory training.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 May 2005
Resolved
Provide proof of established Employer Drug Policy.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 May 2005
Resolved
Provide proof of required drills IAW 46 CFR 122
Action required: 705 - Other - as specified
Resolved 20 May 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 May 2005
Resolved
Prove proper operation of pilot house controls.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Operations/Management › Drills/Instruction › Fire
Issued 18 May 2005
Resolved
Conduct MOB, Fire drill.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 May 2005
Resolved
Stencil name of life-ring buoy.
Due 19 May 2005
Resolved 20 May 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 18 May 2005
Resolved
Provide proof that all portable fire extingushers have been hydrotested IAW NFPA 10.
Due 27 May 2005
Resolved 20 May 2005
Engineering › Steering Gear System › Rudder
Issued 18 May 2005
Resolved
Prove proper operation of steering system while u/w.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 18 May 2005
Resolved
Prove proper operation of MDE's
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 May 2005
Resolved
Prove proper operation of engine cooling system.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 May 2005
Resolved
Prove proper operation of engine exhaust.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 18 May 2005
Resolved
Prove proper operation of fuel system.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 May 2005
Resolved
Prove proper operation of machinery guards.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 May 2005
Resolved
Ensure that all vital system piping is IAW 46 CFR 119.710
Action required: 705 - Other - as specified
Resolved 20 May 2005
Engineering › Reduction Gearing/Clutches › Line Shaft
Issued 18 May 2005
Resolved
Prove shaft log if free of leaks.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 May 2005
Resolved
Clean engine room bilge of excess oil and water.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 May 2005
Resolved
Place locking device on MSD valve.
Action required: 705 - Other - as specified
Resolved 20 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2005
Resolved
Properly dead end all wire in galley.
Due 27 May 2005
Resolved 31 May 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 June 2003
Resolved
Replace 2nd deck fwd stbd fire screen door.
Due 11 June 2003
Resolved 26 November 2003
Fire Fighting › Structural - A Class Divisions › Windows
Issued 11 June 2003
Resolved
Replace main deck fwd stbd door broken window.
Due 11 July 2003
Resolved 26 November 2003
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 11 June 2003
Resolved
C/R lower frame coaming IWO engine room door.
Due 11 July 2003
Resolved 26 November 2003
Stability › Watertight Integrity
Issued 21 March 2003
Resolved
Make fwd & galley watertight doors watertight (fwd door complete/25Mar03).
Due 8 April 2003
Resolved 11 June 2003
Stability › Watertight Integrity
Issued 21 March 2003
Resolved
Renew gaskets to hatch covers in galley & dish room.
Due 8 April 2003
Resolved 11 June 2003
Electrical › Lighting (service)
Issued 14 March 2002
Resolved
Replace power strip in bar with 4 gang receptacle. LEGACY COMPONENT DESC: Outlet Box
Condition: Design Flaw
Due 4 April 2002
Resolved 23 April 2002
Resolution: Proper electrical receptacle installed.
Electrical › Electric Supply System (service)
Issued 14 March 2002
Resolved
Replace burned out vent blower behind reefer boxes. LEGACY COMPONENT DESC: Ventilation
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 23 April 2002
Resolution: New blower installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 March 2002
Resolved
Prove proper operation of starboard main engine oil pressure and RPM gauges. LEGACY COMPONENT DESC: Gauges
Condition: Unknown
Due 4 April 2002
Resolved 23 April 2002
Resolution: Gauges tested sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 March 2002
Resolved
Replace broken window starboard side on main deck. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 4 April 2002
Resolved 23 April 2002
Resolution: Window replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 March 2002
Resolved
Post hearing protection placard at entrance to engine room. LEGACY COMPONENT DESC: Placard
Condition: Unknown
Due 4 April 2002
Resolved 23 April 2002
Resolution: Placard posted.
Engineering › Compressed Air System (start air)
Issued 14 March 2002
Resolved
Prove proper operation of air receiver relief valve. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 4 April 2002
Resolved 23 April 2002
Resolution: Operational check satisfactory.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 March 2002
Resolved
Replace expired first aid kit medications. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 15 March 2002
Resolution: Received fax confirmation from O/O that expired items were replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 March 2002
Resolved
Provide exit signs for deck #2 doors leading to main deck.
Condition: Unknown
Due 14 March 2002
Resolved 14 March 2002
Navigation
Issued 14 March 2002
Resolved
Provide vessel with up to date charts and Coast Pilot. LEGACY COMPONENT DESC: Charts
Condition: Unknown
Due 21 March 2002
Resolved 15 March 2002
Resolution: Received fax confirmation that listed equipment was replaced.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 March 2002
Resolved
Permanently mount four portable fire extiguishers. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 21 March 2002
Resolved 23 April 2002
Resolution: Extinguishers properly mounted.
Engineering › Compressed Air System (start air)
Issued 14 March 2002
Resolved
Conduct a hydrostatic test of air receiver to 1.25 MAWP in presence USCG marine inspector.. LEGACY COMPONENT DESC: Receiver/Bottle
Due 21 March 2002
Resolved 15 March 2002
Resolution: Received by fax, certification test results as conducted and witnessed.by approved facility.
Engineering
Issued 26 April 2001
Resolved
Renew port shaft key.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 26 April 2001
Resolved
V & weld deck beam in way of entrance to tunnel.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 26 April 2001
Resolved
Crop & renew 18" x 18" insert in way of inset at stbd transom.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 26 April 2001
Resolved
Clad weld 2 holes in forward bulkhead to tunnel
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 4 April 2001
Resolved
Provide incombustible hand rails for stairs.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Accommodation/Occupational Safety
Issued 4 April 2001
Resolved
Renew 01 deck doors at top of Port & Stbd stairs with fire doors that meet 46CFR72.05-25(b).
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Engineering
Issued 4 April 2001
Resolved
Provide 2 sources of power for the Mathers engine controls._x001C_ Plan review not required. Discussed requirements with owner. Installationto include dual batterey banks connencted to standard crossover switch providing distribution to controls.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Navigation
Issued 4 April 2001
Resolved
Remount anchor light so as to be visible from 360 degrees IAW Nav rules.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Construction/Loadline
Issued 4 April 2001
Resolved
Remove carpet from under main deck/01 deck fire doors.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Construction/Loadline
Issued 4 April 2001
Resolved
Provide an appropriate "A" class bulkhead and a fire door between the galley and accommodations spaces.
Condition: Unknown
Due 15 October 2002
Resolved 23 October 2002
Resolution: Examined and verified structural fire protection boundary for stairwell and fire door between galley and accommodation space.
Approved plans and apporved equipment list were used in verifying satisfactory work.
Documentation
Issued 4 April 2001
Resolved
Provide plans for evaluation/approval prior to the installation of the "A" class bulkhead noted in NY07.
Condition: Unknown
Due 1 October 2001
Resolved 8 May 2002
Resolution: Plans approved via NYCMI PR ltr PR-020050.
Construction/Loadline
Issued 17 March 1999
Resolved
v/w port rub rail 4 areas as marked.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 17 March 1999
Resolved
Install bilge strainer forepeak compartment.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 17 March 1999
Resolved
Install bilge strainer in lazarette compartment
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Accommodation/Occupational Safety
Issued 17 March 1999
Resolved
Repair grab rail IWO port entrance.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 12 March 1999
Resolved
REPAIR LATCH ON DOOR TO FORWARD STORAGE AREA
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 12 March 1999
Resolved
MARK FUEL OIL SHUTDOWNS W/1" LETTERING
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Electrical
Issued 12 March 1999
Resolved
PROVIDE PROPER ENCLOSURE FOR KNIFE SWITCH OR REPLACE WITH PROPER SWITCH IWOSTBD ENGINE
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Documentation
Issued 12 March 1999
Resolved
PROVIDE ONBOARD A COPY OF 46 CFR 114 - 122
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Engineering
Issued 12 March 1999
Resolved
INSTALL MACHINERY GUARD ON MAIN ENGINE VIBRATION DAMPER.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Accommodation/Occupational Safety
Issued 12 March 1999
Resolved
PROVIDE STEEL OR EQUIVALENT PIPING IWO GALLEY DECK DRAINS AND GREY WATER TANKS
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 12 March 1999
Resolved
ATTACH 3 FT LANYARD FOR WATER LIGHT ON RING BUOY
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Engineering
Issued 12 March 1999
Resolved
PROVIDE STEEL FLAME SHIELD ON 4 F/O FILTERS FOR MAIN DIESEL ENGINES
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Electrical
Issued 12 March 1999
Resolved
PROVIDE SCHEMATIC FOR KNIFE SWITCH STBD SIDE ENGINE ROOM
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Electrical
Issued 12 March 1999
Resolved
PROVIDE WIRE FASTENERS EVERY 24" IN ENGINE ROOM
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 12 March 1999
Resolved
SEAT TANK TOP OPENINGS FOR SEWAGE AND GREY WATER TANKS.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 12 March 1999
Resolved
REPAIR OR REPLACE DEPTH SOUNDER
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 12 March 1999
Resolved
PROVIDE PROOF OF SERVICING ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 12 March 1999
Resolved
REPAIR BECKETS ON LIFE BUOY
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 12 March 1999
Resolved
PROVIDE SEGREGATION OF CHILD AND ADULT LIFE JACKETS
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Fire Fighting
Issued 12 March 1999
Resolved
PROVIDE PLANS AND INSTALL BULKHEADS, CEILINGS, DUCTING TO MEET STRUCTURAL FIRE PROTECTION REQUIREMENTS IAW 46 CFR 177.10-5 IWO BRIDGE, HVAC SERVICE SPACE, FORWARD STORAGE AREA AND BULKHEAD DECK ACCOMODATIONS SPACE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Unknown
Issued 3 April 1998
Resolved
Mark passenger capacity of upper decks.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998
Resolved
Remove 2 ring bouys from wheelhouse and properly mount about vessel.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 4 April 1997
Resolved
LABEL EMERGENCY ESCAPE HATCH FROM GALLEY
Condition: Unknown
Due 12 April 1997
Resolved 4 April 1997
Electrical
Issued 4 April 1997
Resolved
LABEL ELECTRICAL CONTROL BOXES THOROUGHOUT VESSEL
Condition: Unknown
Due 12 April 1997
Resolved 4 April 1997
Construction/Loadline
Issued 4 April 1997
Resolved
LABEL BILGE MANIFOLD VALVES AS TO COMPT SERVED.
Condition: Unknown
Due 12 April 1997
Resolved 4 April 1997
Construction/Loadline
Issued 4 April 1997
Resolved
Reweld bracket for bilge valve reachrod in peak tank.
Condition: Unknown
Due 12 April 1997
Resolved 4 April 1997
Engineering
Issued 4 April 1997
Resolved
PORT & STBD SHAFTS ARE SEVERELY PITTED AND WASTED AND REQUIRE REPLACEMENT
Condition: Unknown
Due 12 April 1997
Resolved 4 April 1997
Lifesaving
Issued 18 April 1995
Resolved
PROVIDE TWO ADDITIONAL CHILD PFD'S. TOTAL CHILD PFD'S REQUIRED IS 26. AUTHORIZED TO SAIL WITH NOT MORE THAN 24 CHILDREN ON BOARD.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Lifesaving
Issued 11 April 1995
Resolved
PROVIDE & INSTALL A RESCUE BOAT/PLATFORM.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Lifesaving
Issued 18 January 1995
Resolved
VESSEL NOT TO BE OPERATED UNDER THE AUTHORITY OF COI UNTIL SAT COMPLETIONOF CREDIT DRYDOCK EXAMINATION.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Unknown
Issued 19 April 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Construction/Loadline
Issued 21 November 1991
Resolved
REMOVE PRESENTLY INSTALLED CLASS ONE (01) WATERTIGHT DOOR IN WAY OF MTWB_x001C_ LOCATED AT FRAME 28 AND INSTALL AN APPROVED CLASS THREE (03) SLIDING WATER-TIGHT DOOR, OR PROVIDE DOCUMENTATION FROM MARINE SAFETY CENTER (MSC) THAT PRESENTLY INSTALLED DOOR NOT REQUIRED FOR SUBDIVISION PURPOSES.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Unknown
Issued 21 November 1991
Resolved
SATISFY COMMENTS CONTAINED IN COMMANDING OFFICER, MARINE SAFETY CENTER (MSC-1) LETTER 16710/ROYAL PRINCESS, SER H2-10452 ISSUED 3JUN91, SUBJ:_x001C_ STABILITY, GENERAL ARRANGEMENT, STRUCTURAL FIRE PROTECTION.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Electrical
Issued 21 November 1991
Resolved
SATISFY ALL COMMENTS TO COMMANDING OFFICER, G-MSC-2 LETTER 16710/ROYAL_x001C_ PRINCESS, SERIAL: E-10455 ISSUED 12 JUNE 1991, SUBJ: ELECTRICAL INSTALLATIONS.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991