ROYAL PRINCESS

ROYAL PRINCESS is a 1991 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in November 2025, along with 49 deficiencies, 1 operational control and 1 casualty investigation in 2018.

Records from 2016 to 2025. Most recent: inspection, 8 November 2025.

Built
1991
Last inspected
8 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDL5921
362521
Flag
UNITED STATES
Maury page id
psix-362521

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)115.3 ft × 26.0 ft × 8.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)115.3 ft × 26.0 ft × 8.1 ft
ITC tonnageNot recorded
BuilderU.S. ADMIRAL INC · MORGAN CITY, LA, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GCS 135 Tank Barge · MISLE 46419 · 18 April 2018 · activity 6394726

Inspection history · 30

8 November 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8265921
23 June 2025 COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8165469
11 June 2025 Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8157656
22 April 2025 Inclining Experiment
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8118579
22 November 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038458
5 December 2023 Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833937
29 August 2023 Inclining Experiment
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7808837
27 June 2023 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7725376
25 May 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7700261
14 March 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7650627
23 February 2023 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7641539
9 June 2022 In-Service Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472965
18 March 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414119
30 November 2021 DAPI Audit · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7357019
17 November 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7352861
17 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008507
18 June 2020 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6974046
24 June 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6780951
16 April 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760958
1 April 2019 Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760831
23 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6566311
11 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6440699
19 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394505
19 April 2018 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394534
18 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394726
16 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6338223
21 December 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6331467
15 May 2017 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6146258
20 March 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6107774
13 June 2016 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5906247

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2025 Resolved
Vsl was missing structural fire protection in the overhead of the engine room by the switch board and distribution panel. Renew the structural fire protection with an approved type to the satisfaction of the attending marine inspector. 46 CFR 177.10-5(a) 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: installed new SFP.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2025 Resolved
Vsl had dry engine exhaust piping that was not insulated. Install lagging/insulation over those unprotected exhaust pipes to the satisfaction of the attending MI. 46 CFR 177.10-5(b) 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 8 November 2025
Resolution: new lagging installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2025 Resolved
Bridge and galley portable fire extinguishers were not mounted properly. Properly mount all fire extinguisher to the satisfaction of the attending MI. 46 CFR 181.30-10 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: mounted properly
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2025 Resolved
Port side main deck amidships wooden door was worn at the bottom. Replace/install an approved fire door for that space to the satisfaction of the attending MI. 46 CFR 177.10-5(a) 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 8 November 2025
Resolution: wooden door repair with metal kick plate.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 17 September 2025 Resolved
Emergency lighting was missing from the secondary means of escape in the bridal suite and the galley. Install proper emergency lighting for secondary escape means to the satisfaction of the attending MI. 46 CFR 184.30-4 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: E light installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 June 2025 Resolved
Vsl was missing all charts and publications (coast pilot, light light, tide tables, currents, etc). Provide all necessary charts and publications to the vsl and route to the satisfaction of the attending MI. 46 CFR 121.420 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 18 September 2025
Resolution: electronic charts and pubs, SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2025 Resolved
Vsl could not preform bilge suction from any space using the fixed installed system. Vsl is required to show that the fixed bilge system (with 02 pumps) is capable of draining/dewatering all watertight compartments for the satisfaction of the attending MI. 46 CFR 182.25-1 701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Verified proper operation
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2023 Resolved
A Certificate of Inspection is obtained or renewed by making application on Form CG 3752, “Application for Inspection of U.S. Vessel,” to the Coast Guard OCMI of the marine inspection zone in which the inspection is to be made. The vessel's routes and conditions dot not permit the carriage of passengers in the Sector Jacksonville OCMI zone. Vessel to submit CG-3752, application for inspection, to local OCMI. Prior to the carriage of passengers the vessel must complete a New-To-Zone COI inspection to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: COI completed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 March 2023 Resolved
Based upon MSC letter issued on July 13, 2022, vessel must complete either a deadweight survey or incline test to verify lightship characteristics. A stability test procedure must be submitted to MSC for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 August 2023
Resolution: Inclining Experiment was conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2023 Resolved
Vessel has onboard SeaKeeper not approved for operation. Owner/operator must submit electrical plans for Seakeeper to MSC for review and approval prior to use.
Action required: 705 - Other - as specified
Resolved 1 June 2025
Resolution: Vessel submited/received approved updated stability letter.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 March 2023 Resolved
Observed improper installation of overhead longitudinal frame in compartment above where SeaKeeper is installed. Make proper repairs to overhead longitudinal frame.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Observed repair of overhead frame.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2023 Resolved
Provide sign and donning instructions for lifejackets on main deck. 46CFR117.78 46CFR122.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 25 May 2023
Resolution: Donning instructions provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 February 2023 Resolved
Update DER, conduct EAP and drug awareness training. 49CFR40.3 46CFR16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 25 May 2023
Resolution: Records updated.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2023 Resolved
Renew aft port corner broken glass window. 46CFR 116.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2023
Resolved 15 March 2023
Resolution: MI attended vessel and witnessed satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 February 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Bilge system strainer in steering compartment was severely obstructed by mud and marine growth. Clean bilge strainer in steering compartment and check all others. 46CFR119.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Witnessed satisfactory test of new bilge suction from forward peaktank with new bilge strainer install.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 February 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Man hole covers for oil tanks in E/R were removed to use space for storage. Re-install all man hole covers in engine room. 46CFR116.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Hatch covers installed to maintain watertight integrity of bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 February 2023 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. One if the lifebuoys on board is missing grab line. Provide three ring buoys in satisfactory condition. 46CFR117.70(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Vessel equipped with 3 life buoys in serviceable condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2021 Resolved
All wiring shall be suitable for marine service. Remove all rope-style lights from the interior of the vessel. 46 CFR 183.10-20
Action required: 10 - Deficiency Rectified
Resolved 30 November 2021
Resolution: Rope-style lights removed in presence of marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 November 2021 Resolved
The power fire pump shall be fitted with a pressure gauge. The pressure gauge does not work. 46 CFR 181.10(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
Resolution: Operations manager sent picture of new gauge.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 30 November 2021 Resolved
Each vessel must meet applicable requirements of subchapter S. According to stability letter, only 75 passengers are authorized on the upper deck. 46 CFR 177.13-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
Resolution: Operations manager sent picture of passenger upper deck limit.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 November 2021 Resolved
Vessel's COI is invalid due to over due annual inspection. Vessel is prohibited from the carriage of passengers until a satisfactory annual inspection is completed. 46 CFR 176.500(1)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 July 2020 Resolved
Vessels operated soley within 20 nautical miles of land msut be equipped with a VHF-DSC radiotelephone installation. Both the port and starboard VHF radios could not send or recieve radio signal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2020
Resolution: witnessed via video installation and proper operation
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 June 2019 Resolved
Remote fuel shut off valve pull cable has failed, repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2019
Resolution: The cable and pull handle was replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2019 Resolved
Provide a cover for the battery box fwd engine room stbd side.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019 Resolved
Removed the dish rack from the front side of the electrical distribution panel in the the galley. The dish rack is preventing the distribution panel from being able to be opened.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 June 2019 Resolved
The galley exhaust fans have oil accumulation of the motor creating a fire hazard, clean.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Complete
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 April 2019 Resolved
Bottom plate between the keel cooler is corroded. Provide a repair proposal and conduct repairs.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 18 June 2020
Resolution: Attending marine inspectors verified satisfactory repairs completed as per previously approved repair proposal.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 October 2018 Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0) and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 September 2025
Resolution: New AIS installed. AIS broadcasting properly.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 June 2018 Resolved
All vessels bilge high water level alarms were inoperable. Vessel is to prove proper operation to CG Marine Inspector. 46 CFR 119.530. PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Vessel repaired high level alarms.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 June 2018 Resolved
Vessel was unable to provide several documents upon request. Vessel is prove full compliance with DAPI to CG Marine Inspector. 46 CFR 16. PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2018
Resolution: Vessel provided documents to prove complaince with DAPI
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2018 Resolved
Vessel is to provide CG approved first aid kit. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel had an approved first aid kit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 June 2018 Resolved
Vessel's waterlight lanyard on bridge life buoy is too long. vessel needs to correct length. 46 CFR 117.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel provided waterlight lanyard of correct length
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 11 June 2018 Resolved
Vessels raw water pump for cooling port engine is leaking excessively. Vessel needs to repair. 46 CFR 119.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Raw water pump was repaired and no longer leaking.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 June 2018 Resolved
vessel needs to provide guard for lighting fixture located in the engine room. 46 CFR 120.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: A guard was installed on lighting fixture.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 June 2018 Resolved
Vessel has a 3 amp ground while connected to shore power. Vessel must make a means to eliminate potential for creating a ground. 46 CFR 120.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 19 June 2018
Resolution: Vessel no longer had a ground.
Construction/Loadline › Hull › Side Shell
Issued 19 April 2018 Resolved
Vessel must submit approved tow plan to USCG MI prior to movement from Chelsea Pier.
Action required: 10 - Deficiency Rectified
Due 13 June 2018
Resolved 13 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 19 April 2018 Resolved
Vessel must submit technician report and have USCG Marine Inspector witness safe operation of machinery and vessel maneuvering (sea trials) prior to carrying passengers, operating main engines, or any movement in addition to the single tow plan voyage.
Action required: 10 - Deficiency Rectified
Due 13 June 2018
Resolved 27 April 2018
Construction/Loadline › Hull › Side Shell
Issued 19 April 2018 Resolved
Vessel must submit repair plan to USCG for approval for side shell damage prior to repairs. Vessel must have USCG inspect repairs prior to carrying passengers, operating main engines, or any movement in addition to the single tow plan voyage.
Due 13 June 2018
Resolved 13 June 2018
Engineering › Bilge Water Management System › Pump
Issued 15 May 2017 Resolved
1. Prove proper operation of vessels bilge system.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 15 May 2017 Resolved
2. Properly repair identified exhaust leak in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 May 2017 Resolved
3. Properly repair identified port shaft seal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 May 2017 Resolved
4. Prove proper operation of watertight door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2016 Resolved
Repair port MDE exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Flex hose replaced.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 June 2016 Resolved
Repair generator exhaust leak
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Hose clamp replaced.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 June 2016 Resolved
Provide ground detection
Condition: Improper/Lack of Maintenance
Due 13 July 2016
Resolved 17 June 2016
Resolution: Amp meter replaced and operational. Ground lights operating.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 13 June 2016 Resolved
Provide means to inspect/test air receiver.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: System tested.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2016 Resolved
Provide DSC on VHF radios (MMSI #)
Condition: Improper/Lack of Maintenance
Due 13 July 2016
Resolved 17 June 2016
Resolution: DSC provided
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 13 June 2016 Resolved
Provide post casualty drug and alcohol testing procedures.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: Procedures emailed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 June 2016 Resolved
Provide march 2016 MIS report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2016
Resolution: MIS report submitted.

Casualty record · 1

18 April 2018Routine · role: Involved in a Marine Casualty · activity 6394726
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.