← All vessels
TAMAR
TAMAR is a 1973 tank ship. The Coast Guard has recorded 7 inspections since 1998, most recently in October 2000, along with 17 deficiencies and 1 operational control.
Records from 1998 to 2000. Most recent: inspection, 8 October 2000.
- Built
- 1973
- Last inspected
- 8 October 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7302823 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8KI4
362599
Flag
SWEDEN
—
Maury page id
psix-362599
Inspections, by type
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6746 - Dead Weight, Ton
2183 - Regulatory (Subpart C or D), Net Ton
4315 - Regulatory (Subpart C or D), Gross Ton
2183 - Regulatory (Subpart C or D), Net Ton
4315 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
8 October 2000
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1443083
28 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051065
25 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 277168
6 May 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 428249
20 March 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 426548
27 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423783
27 December 1998
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 809464
Deficiency record · 17
Accommodation/Occupational Safety
Issued 25 April 2000
Resolved
TEMP REPAIRS TO SEWAGE PIPE AT HOLDING TANK AFT PUMP PIPING. _x001C_ REPAIR TO SATISFACTION OF CLASS BY 28MAY00.
Engineering
Issued 25 April 2000
Resolved
1" HOLE IN COMING IWO #15 C.T. MAKE TEMP REPAIRS PRIOR TO CONDUCTING CARGOOPS. PERMANENT REPAIRS BY 28MAY00.
Fire Fighting
Issued 25 April 2000
Resolved
INTERNATIONAL SHORE TIE CONNECTION NOT SLOTTED/MISSING GASKETS. _x001C_ CORRECT TO SATISFACTION OF CLASS BY 28MAY00.
Navigation
Issued 25 April 2000
Resolved
STEERING OPERATING SELECTOR VALVES LEAKING. REPAIR TO SATISFACTION OF USCGBY 28MAY00.
Engineering
Issued 25 April 2000
Resolved
PORT & STBD AIR COOLING PIPE FOR MAIN DIESEL HAS (4)TEMP REPAIRS STBD (1)TEMP REPAIR @ PORT VALVE. PROVIDE PERMANENT REPAIRS TO SATISFACTION OF CLASS BY 28MAY00.
Accommodation/Occupational Safety
Issued 25 April 2000
Resolved
STBD LADDER TO SUPPER STRUCTOR BASE BASE WASTED. MAKE REPAIRS TO SATISFACTION OF CLASS BY 28MAY00.
Fire Fighting
Issued 20 March 1999
Resolved
HOLED/WASTED FIRE MAIN PIPING LOCATED ON PORT SIDE IN FRONT OF HOUSE. RENEWWASTED/HOLED PIPE BY 20APR99 TO THE SATISFACTION OF CLASS SOCIETY.
Deck/Cargo
Issued 20 March 1999
Resolved
HIGH LEVEL ALARM LIGHT IS NOT LABLED. PROPERLY LABEL HIGH LEVEL ALARM INDICATOR TO THE SATISFACTION OF USCG INSPECTOR PRIOR TO 20APR99.
Navigation
Issued 20 March 1999
Resolved
SOUND POWERED TELEPHONE IN STEERING SPACE IS UNABLE TO CALL BRIDGE. PROVE PROPER OPERATION OF PHONE TO THE SATISFACTION OF CLASS PRIOR TO 20APR99.
Navigation
Issued 20 March 1999
Resolved
46CFR PARTS 35, 150, AND 153 NOT ON BOARD. OBTAIN CURRENT COPIES OF EACH ONBOARD PRIOR TO 20APR99.
Deck/Cargo
Issued 20 March 1999
Resolved
AUDIBLE ALARM FOR HIGH LEVEL ALARM IS TOO LOW IN VOLUME. PROVE PROPER OPERATION OF ALARM TO THE SATISFACTION OF USCG INSPECTOR PRIOR TO 20APR99
Electrical
Issued 20 March 1999
Resolved
IDENTIFIED 3 EXPOSED ELECTRICAL WIRES IN PAINT LOCKER I.W.O. FORWARD BULKHEAD. REMOVE OR PROPERLY SECURE EXPOSED ELECTRICAL WIRES BY 20APR99 TO THE SATISFACTION OF CLASS SOCIETY.
Documentation
Issued 20 March 1999
Resolved
ORIGINAL COFR NOT ON BOARD, VESSEL HAD VERIFICATION NUMBER BUT HAD NOT RECIEVED DOCUMENT YET. PROVIDE ONBOARD TO THE SATISFACTION OF USCG INSPECTOR PRIOR TO 20APR99.
Fire Fighting
Issued 20 March 1999
Resolved
HOLED/WASTED FIRE MAIN PIPING LOCATED I.W.O. MAIN FIRE PUMP IN E/R. HOLED PIPING IS LOCATED AT FLANGE WHERE FIRE MAIN DISCHARGE PIPE MEETS THE AIR VENT LINE. RENEW TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 20APR99.
Fire Fighting
Issued 27 December 1998
Resolved
WATER TIGHT DOOR TO CO2 ROOM WILL NOT SEAL DUE TO DAMAGE ON THE UPPER KNIFEEDGE.
Electrical
Issued 27 December 1998
Resolved
EXPLOSION PROOF LIGHTS IN PAINT LOCKER ON PORT SIDE ARE DAMAGED.
Electrical
Issued 27 December 1998
Resolved
EMBARKATION LIGHTS AT LIFEBOAT AREA INOPERATIVE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.