MAURY USCG vessel records Sign in
← All vessels

THEODORA

THEODORA is a 1991 tank ship. The Coast Guard has recorded 6 inspections since 1991, most recently in March 1998, along with 9 deficiencies.

Records from 1991 to 1998. Most recent: inspection, 19 March 1998.

Built
1991
Last inspected
19 March 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9005338 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
362934
Flag
NETHERLANDS
—
Maury page id
psix-362934

Inspections, by type

…with no type recorded5
Years with a record 2 calendar years (1991–1998)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1460 - Regulatory (Subpart C or D), Net Ton
6550 - Dead Weight, Ton
5000 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

19 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 413917
12 February 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412724
12 February 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460152
9 August 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 345194
16 May 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 344625
16 May 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 915539

Deficiency record · 9

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 March 1998 Resolved
SJO1. INSULATION ON THE VAPOR CONTROL SYSTEM PIPE FORWARD ON DECK REQUIRES REPAIR APPROXIMATELY A 15FT SECTION. REPAIR AT DRYDOCK.
Condition: Unknown
Due 31 December 1998
Resolved 6 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 19 March 1998 Resolved
INSTALL CONTAINMENT FOR LUBE OIL BUNKERING STATION. INSTALL DURING DRYDOCK
Condition: Unknown
Due 31 December 1998
Resolved 6 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 March 1998 Resolved
SJ03. PROVIDE CLASS SOCIETY DOCUMENTATION ATTESTING TO THE CONDITION OF CARGO PUMP ROOM.
Condition: Unknown
Due 31 December 1998
Resolved 6 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Deck/Cargo
Issued 12 February 1998 Resolved
THE VAPOR CONTROL SYSTEM PIPE INSULATION FORWARD ON DECK. REPAIR INSULATION.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998
Documentation
Issued 12 February 1998 Resolved
PROVIDE MARINE CHEMIST GAS FREE CERTIFICATE FOR PUMP ROOMS AND MAKE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998
Deck/Cargo
Issued 12 February 1998 Resolved
PAINT VAPOR COLLECTION CONNECTION POINT WITH RED/YELLOW/RED BANDS. FACILITY VAPOR CONNECTION FLANGE REQUIRES STUD ON FLANGE FACE.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998
Deck/Cargo
Issued 12 February 1998 Resolved
LUBE OIL BUNKERING STATION REQUIRES CONTAINMENT BARRIER.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998
Lifesaving
Issued 12 February 1998 Resolved
RETRO TAPE REQUIRED ON BOTTOM OF LIFE BOAT.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998
Fire Fighting
Issued 12 February 1998 Resolved
PROPERLY LABLE INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 12 February 1998
Resolved 20 March 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.