POSEIDON

Built
1991
Last inspected
13 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9040596
WDK 3553
362965
Flag
UNITED STATES
Maury page id
psix-362965

Documentation record

Registered dimensions (L × B × D)117.5 ft × 30.0 ft × 11.9 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)117.5 ft × 30.0 ft × 11.9 ft
ITC tonnagegross 288 / net 86
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOMER, AK
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
288 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
86 - Convention (Subpart B), Net Ton
264 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

13 May 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8324201
19 February 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8317589
27 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8102921
27 February 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8085355
21 February 2024 Administrative Inspection · Construction Oversight · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7870636
15 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7688672
11 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7689347
22 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7655289
1 February 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7630247
9 June 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7472168
22 December 2020 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7115049
7 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7107648
23 October 2019 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6843818
8 June 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6438153
6 March 2017 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6099366
15 November 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6041250
3 November 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6034813

Deficiency record · 27

01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 9 May 2024 Resolved
Provide tonnage measurement organization (ABS) letter attesting to validity of current tonnage certificate after modifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 26 February 2026
Resolution: Vsl rep worked with CG (HQ) and ABS to confirm no change to tonnage following modifications.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 May 2024 Resolved
Mark emergency escape route (ladder) in forward lower deck stateroom area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 May 2024
Resolution: Escape route marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024 Resolved
Relocate ring lifebuoy with attached lifeline to weatherdeck from wet/dry lab.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 May 2024
Resolution: Life buoy relocated to weather deck.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2024 Resolved
Provide one additional 2-A portable fire extinguisher for science office aft of pilothouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 May 2024
Resolution: Additional 2-A extinguisher added to science office.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024 Resolved
Segregate child lifejackets from adult lifejackets in upper deck lifejacket box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 May 2024
Resolution: Child lifejackets segregated from adult within container.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 March 2023 Resolved
For a fixed gas fire extinguishing system each control valve must be marked to indicate the space served. Control valves were not marked.- 46 CFR 185.612(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2023
Resolved 9 May 2024
Resolution: System labeled.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 March 2023 Resolved
The master must ensure that the Fixed CO2 lockout valve is locked open at all times when system is not being serviced. The lockout valve was not locked in the open position. A satisfactory lock was put into place to lock the valve in the open position.- 46 CFR 181.410(f(7)(iv)
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: A lock was put into place to lock the valve in the open position to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 March 2023 Resolved
Each life buoy must be marked with Type II retroreflective material. Two aft deck life buoys had worn retroreflective material and was satisfactorily replaced. - 46 CFR 185.604(i)
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 23 March 2023
Resolution: Two aft deck life buoys had worn retroreflective material that was replaced satisfactorily to the attending USCG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2019 Resolved
To maintain a valid COI, you must complete your annual inspection within the period specified in 91.27-1(a) and your COI must be endorsed. The anniversary date of the vessel is 22 JUN, the inspection window is between 22 MAR and 22 SEP. Vessel failed to schedule or complete an annual inspection within the required time frame. Vessel must complete an inspection for certification.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2019
Resolved 8 November 2019
Resolution: Completed COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019 Resolved
EACH CARGO VESSEL MUST CARRY THE NUMBER OF LIFEBUOYS SPECIFIED IN TABLE 199.271. LIFEBUOY ON STARBOARD O-1 DECK WAS LEAKING WATER AND NOT SERVICEABLE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Lifebuoy Replaced
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2019 Resolved
THE SIDELIGHTS OF VESSELS OF 20 METERS OR MORE IN LENGTH SHALL BE FITTED WITH MATTE BLACK INBOARD SCREENS AND MEET THE REQUIREMENTS OF § 84.15. SCREENS WERE PAINTED GLOSS BLACK.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Screens painted with matte black
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019 Resolved
WATER LIGHT BATTERIES MUST BE VALID. OBSERVED EXPIRED BATTERIES TO WATER LIGHTS OF LIFE FLOATS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: New batteries purchased and installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2019 Resolved
FUEL SYSTEM SHOULD BE FREE OF ANY LEAKS. PORT MDE F/O SUPPLY IS LEAKING, VSL MUST FIX LEAK.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2019
Resolved 8 November 2019
Resolution: Leaks repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
TYPE II ELECTRICAL SAFETY MATTING IS REQD IN FRONT OF SWBD. VSL DOES NOT HAVE MATTING, VSL MUST PROVIDE MAT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: electrical safety matting installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
NON METALLIC FLEX LINES FOR OIL SYSTEMS SHALL NOT EXCEED 30" IN LENGTH. SEVERAL F/O AND L/O LINES ON BOTH MDE AND SSDG HAD FLEX LINES WHICH WERE TOO LONG. VSL MUST REPLACE WITH SHORTER FLEX LINES.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Piping intalled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
ELECTRICAL CONTROL PANELS MUST PROTECT USERS FROM SHOCK. VSL HAS TWO CONTROL BOXES WHICH HAVE OPENINGS AND EXPOSED CONTACTS. VSL MUST EITHER REMOVE/REPLACE THE CONTROL BOXES.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Panels replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2019 Resolved
INTERNAL COMBUSTION ENGINES MUST BE FREE OF OIL LEAKS. STBD SSDG HAS SEVERAL LITERS OF OIL IN BED PAN. VSL MUST FIX OIL LEAK IN STBD SSDG.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2019
Resolved 8 November 2019
Resolution: SSDG's leaking Governer was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
ELECTRICAL WIRING MUST BE CONTAINED IN A JUNCTION BOX. WIRING FOR MURPHY SWITCH OVER CENTER AUX ENGINE IS EXPOSED. VSL MUST ENCLOSE WIRING IN BOX.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Wiring installed in proper boxes
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2019 Resolved
ELECTRICAL MOTORS MUST BE IN GOOD SERVICEABLE CONDITION. F/O TRANSFER PUMP MOTOR CONTROLLER AND MOTOR HOUSING IS SEVERELY CORRODED DOWN TO THE WINDINGS. VSL MUST REPLACE MOTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: F/O X-fer pump replaced
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 October 2019 Resolved
VSL MUST REMOVE ALL REMINENTS OF OLD INOPERABLE FIXED CO2 SYSTEM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 8 November 2019
Resolution: Old CO2 pull stations rempved from service.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 6 March 2017 Resolved
Doc not current.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: Doc not needed and vessel will not keep one.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 6 March 2017 Resolved
Hydraulic isolation valve missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: Valve replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Silencer
Issued 6 March 2017 Resolved
Air intake piping elbow missing on the port main.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: Rep added new elbow to the air intake piping on the port main.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 6 March 2017 Resolved
All scuppers on the deck containment missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2017
Resolution: New scuppers added to all deck coaming.
Lifesaving › Lifefloat › Serviceable
Issued 6 March 2017 Resolved
One life float unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: A new life float was added in replacement.
Lifesaving › Hand Flares › Not on Board
Issued 6 March 2017 Resolved
Vessel did not have the correct flares onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: Proper flares were added.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 6 March 2017 Resolved
Alarms not acknowledging on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2017
Resolution: Issue corrected. Tested alarms, all sat.