EASY DIVER

Built
1991
Last inspected
16 June 2022
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 June 2022
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ2033
363079
Flag
UNITED STATES
Maury page id
psix-363079

Documentation record

Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
7 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 88 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

16 June 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7479383
8 March 2021 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7148051
6 November 2020 Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7114897
15 September 2020 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7023501
15 November 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6855825
28 August 2018 Deficiency Check · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6496709
12 December 2017 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6325052
4 October 2016 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6015646
27 September 2016 Drydock Exam · Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6013425
8 January 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5793479

Deficiency record · 88

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 June 2022 No resolution recorded
Vessel failed to conduct an Annual Inspection within 90 days before or after its anniversary date and was issued a prior to carrying passenger deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2021 Resolved
Fire boy system is not functioning properly to provide override function as well as audible and visual alarms. Ensure that fireboy system is properly functioning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2021 Resolved
Both the automatic bilge pumps and the high water alarms need to be repaired. Pumps must function in coordination with float switch and have a visual indicator at the operating station. High water alarms must have both an audible alarm and a visual indicator at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 March 2021 Resolved
Tiller for the emergency steering is inadequate. Ensure that vessel is able to be maneuvered with emergency tiller arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021 Resolved
Vessel's engine noise prevents clear communication between master and deck hand during recovery of persons overboard and or emergency steering scenareo. Provide means for effective communication between crew members in case of emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 September 2020 Resolved
Vessel has significant structural damage to the deck from delamination and wood rot of structural members. Deck must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2020
Resolved 8 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2020 Resolved
The port and starboard fuel tanks are encased in fiberglass. The visible sections of the tank show significant corrosion. Make entire tanks available for inspection, pressure test,or replace tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2020
Resolved 19 January 2021
Resolution: new approved tank installed in vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019 Resolved
Repair/replace lifefloat, L/F is faded and no longer orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 November 2019 Resolved
Preengineered fixed firefighting system once discharged must allow for the vessels engine to restart. During the test oft he FIREBOY the engine was unable to restart after the simulated discharge and continued to read as discharged. Perform successful test in the presence of the local Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2019
Resolution: Oprationally tested, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 November 2019 Resolved
Ring Buoy must meet the specifications listed in 46 CFR 160.050 and must be fitted with a 5/16 buoyant life line at least 60ft in length that is non-kinking breaking strength of at least 1124 lbs and of dark color. Ring Buoy did not meet the above specifications. Replace, ring buoy and line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2019
Resolution: New ring buoy added.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 November 2019 Resolved
Floating water light must have a 3 ft lanyard with a corrosion resistant clip to allow for quick disconnect. Replace line and install a clip on ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Lanyard provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 November 2019 Resolved
Battery for water-light attached to ring buoy was not marked with an expiration date. Due to lack of expiration date the battery must be replaced. All batteries are to be replaced every 2 years at a minimum.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Battery replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 November 2019 Resolved
COI and Stability letter must be posted. Post COI in passenger area and the Stability letter near the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Documents provided and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2019 Resolved
01 Adult life jacket torn and condemned. Replace and properly mark 01 new Adult Life Jacket. Passenger count limited to 21.
Action required: 705 - Other - as specified
Resolved 18 November 2019
Resolution: New PFD provided.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 15 November 2019 Resolved
First Aid kit must contain the contents identified in 46 CFR 160.041. Ammonia Inhalants were expired or no longer marked with expiration date. Replenish First aid kit contents with non expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 November 2019 Resolved
Conduct man overboard and fire drill in the presence of a Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 November 2019 Resolved
Vessel must have adequate and up to date publications on board. Vessel did not have a Coast Pilot, light list and tide tables. Vessel did not have the required publications on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2019 Resolved
Electrical installations must conform to Sub-chapter T. Fuses under the operating station were not of the required cartridge type , numerous dead end wires were not properly terminated or removed and the use of alligator clamps in the overhead by the radio are not authorized. Replace fuses with the appropriated type fuses, properly terminate or remove dead end wires and make all electrical connections are permanent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 18 November 2019
Resolution: Wiring corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2019 Resolved
Replace submersible bilge pump in lazarette space with pump that meets requirements of UL 1113.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Provide securing devices, new gasket, and hinges or device to secure hatch to vessel to prevent its loss for Engine Room hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Hatches secured and gasket applied.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Provide device to secure hatch to vessel to prevent its loss for lazarette and battery compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Watertight hatches must have means to be secured to deck, lazarette and battery compartment have the capability to be secured but tool is not currently on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Latches secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2019 Resolved
Join fuel tank fill pipe to fuel tank with a conductor (wire) on both tanks for the protection against generation of static charge when fueling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Bonding wires provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2019 Resolved
Remove excess oil from bilge in forward compartment
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Oil removed
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2019 Resolved
Repair engine oil leak, engine is leaking oil at the top rear of cylinder head
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Oil cleaned up and hose clamp applied to blowoff valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 November 2019 Resolved
Repair/replace exhaust lagging (insulation) in way of cooling water injection
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 November 2019 Resolved
Provide a mast and stern navigation light that meet visibility requirements set forth in 33 CFR 83.22, vessels over 12 meters shall have a stern and mast light independent of the all-around white light (rule 23). Day time operations only.
Action required: 705 - Other - as specified
Resolved 26 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2019 Resolved
Replace hose clamp on raw water intake hose in way of impeller pump on engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Clamp replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2019 Resolved
Close all bulkhead penetrations in engine room, space protected by fixed fire extinguishing equipment (fireboy) shall be able to contain fire agent and not leak into other compartments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2018 Resolved
Draw shaft and conduct run out test with dial indicator. Provide results to local OCMI, to include the maximum reading recorded from the gauge.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Shaft run out results were .010, vessel owner replaced shaft in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 September 2018 Resolved
Install 6 inch coaming on weather deck at entrance to forward compartment to ensure watertight integrity.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: 6" coaming installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018 Resolved
Repair/replace steel rudder post frame; framing is wasted and no longer structurally sound for supporting the steering system.
Action required: 705 - Other - as specified
Resolved 27 September 2018
Resolution: Rudder post frame completely replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018 Resolved
Repair/replace diesel engine port aft motor mount; mount is wasted with large amount of scaling rust.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All 4 mounts replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018 Resolved
Replace sea valve for raw water pickup for engine cooling located in the port-side of engine room. Valve was unable to move to the closed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 27 September 2018
Resolution: Valve repaired and is functioning properly, photos attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2018 Resolved
Replace screw down stop valve on port overboard discharge pipe for submersible bilge pump located in battery compartment. Valve is wasted and unable to be moved.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: valve replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 September 2018 Resolved
Repair/replace port side longitudinal deck beam in lazarette space. 2x4 is rotted, submit repair proposal to local OCMI prior to conducting repairs.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All deck beams aft of engine room were replaced and deck from engine room deck hatch aft was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018 Resolved
Clean and make ready for inspection all fuel hose fittings. Fittings at emergency shut offs, fuel strainer and fuel tank were heavily rusted and may not be serviceable.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Fuel lines cleaned and remain serviceable.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 September 2018 Resolved
Sand down areas on weather deck identified by inspector and have ready for re-inspection. Soft spots on weather deck may be a result of de-laminating FRP.
Action required: 705 - Other - as specified
Resolved 21 September 2018
Resolution: Vessel made area available for inspection. New 835v issued to remove entire aft deck and replace to original strength.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 September 2018 Resolved
Seal/close all bulkhead and deck penetrations in Engine Room to ensure agent for per-engineered fixed gas fire extinguishing system does not escape protected area in the event of a manual or automatic activation.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All penetrations in bulkheads have been sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 September 2018 Resolved
Remove "[name withheld]" from under deck and deck beams in Engine Room and make available for inspection.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Beams cleaned up and remain serviceable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Remove all dead-end wiring in vessel (Battery compartment).
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Wiring cleaned up and dead-ended wires have been removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Removal all oily waste from bilge, excessive accumulation observed in battery and engine room bilge.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: bilges cleaned and free of oily residue.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Conduct underway sea trails with attending Marine Inspector to observe proper operation of steering and propulsion systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2018
Resolution: Satisfactory sea trials conducted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2018 Resolved
Equip vessel with 03 fire buckets 2.5 gallons, labeled fire bucket with attached line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: aquired 3rd bucket, drilled holes at 2.5 gallon mark and attached lanyards
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2018 Resolved
demonstrate proper operation of preengineered fire extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: properly operated the fireboy system
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 August 2018 Resolved
have updated charts of large enough scale aboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: new updated paper charts onboard
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 August 2018 Resolved
replace line from life float to waterlight/bouy light
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: replaced line to water light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 August 2018 Resolved
attach lifefloat to float free link
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: attached lifefloat to floatfree link
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2018 Resolved
post COI and Stability letter
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Documents posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 August 2018 Resolved
post life jacket donning procedures
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Donning instructions posted.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 28 August 2018 Resolved
post emergency instructions
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Emergency Instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 28 August 2018 Resolved
replace hydrostatic release on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: replaced hydrostatic release on EPIRB
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 August 2018 Resolved
Aft deck is of sandwich construction with foam core after a previous replacement. Forward deck is intact and serviceable with original glass over marine grade plywood. Remaining aft (foam core) deck around cut out for deck beams has core separation and must be removed and replaced as original (glass over marine grade plywood) from transom to engine room bulkhead. Must be repaired prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2018
Resolved 5 November 2018
Resolution: Deck replaced from engine room hatch cover to transom.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 December 2017 Resolved
Remove oil from bilge and port battery boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Excess oil was removed from bilge and battery boxes.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 December 2017 Resolved
Make doors and penetrations in engine room bulkhead vapor tight. Area currently exceeds coverage area of Fire Boy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Openings in engine room have been made vapor tight.
Lifesaving › Lifefloat › Serviceable
Issued 12 December 2017 Resolved
Make repairs to life float in accordance with manufacturers instructions. Vessel restricted to operating no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Life float repaired in accordance with manufacturers instructions.
Construction/Loadline › Structures › Deck Plating
Issued 12 December 2017 Resolved
Make repairs to deck in way of fuel tank compartment.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Repaired deck.
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2017 Resolved
Provide means to secure fuel from starboard fuel tank.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Changed configuration of valve handle to allow valve to be closed.
Engineering › Bilge Water Management System › Pump
Issued 12 December 2017 Resolved
Provide proper operation of automatic bilge pumps and high level alarms. Excessive oil in bilge prevented testing.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Proved proper operation of pumps and alarms.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 December 2017 Resolved
Make engine room hatch watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Engine room hatch was gasketed and screwed in place.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2017 Resolved
Make repairs to deck rails.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Reinforced stanchions at deck connection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 December 2017 Resolved
Provide required amount of portable extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Owner provided an additional B-I portable fire extinguisher.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 December 2017 Resolved
Make collision bulkhead watertight.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Reinstalled cover on access opening.
Lifesaving › Lifefloat › Paddle
Issued 12 December 2017 Resolved
Lash paddles to life float.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Paddles are lashed to lifefloat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2017 Resolved
Replace battery in life ring light. Vessel restricted to daylight operations.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 12 December 2017
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 December 2017 Resolved
Renew reflective tape on all PFDs.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Replaced reflective tape on all PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 December 2017 Resolved
Renew 03 child size PFDs.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Provieded 03 new child size PFDs
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2017 Resolved
Properly support all electrical cables throughout vessel.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Bundled and supported cables.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 December 2017 Resolved
Label indicators for high level and automatic bilge pumps.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Labeled indicators.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2017 Resolved
Life ring light must have lanyard 3' to 6' secured around body of life ring.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Replaced lanyard.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 12 December 2017 Resolved
Repair oil leaks on engines.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Repaired oil leaks.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 December 2016 Resolved
Remove oil from all bilges
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2016
Resolution: All oil was removed from bilges
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 December 2016 Resolved
Provide audible alarm for FireBoy
Action required: 705 - Other - as specified
Due 12 December 2016
Resolved 12 December 2016
Resolution: Installed Fireboy switch
Engineering › Bilge Water Management System › Not Operational
Issued 5 December 2016 Resolved
Prove proper operation of automatic bilge pump in holding tank space
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 18 January 2017
Resolution: Owner proved operation of bilge pump.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 December 2016 Resolved
Prove proper operation of visual indicator of v berth automatic bilge pump
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 18 January 2017
Resolution: Owner proved proper operation of indicator of automatic bilge pump.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 December 2016 Resolved
Vessel must have complete first aid kit at all times
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 30 December 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 5 December 2016 Resolved
Label all high water alarms
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 18 January 2017
Resolution: All high water alarms (03) labeled.
Electrical › Electric Supply System (service) › Cable
Issued 5 December 2016 Resolved
Remove all dead ended wire from under console
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 18 January 2017
Resolution: Dead ended wiring has been removed.
Engineering › Fuel Oil Service System › Hose
Issued 5 December 2016 Resolved
Provide documentation that fuel hoses and fittings meet SAE J1942 and SAE J1475
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: Documentation provided.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2016 Resolved
Post COI/Stability Letter
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: COI/Stability Letter posted
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 September 2016 Resolved
Remove FRP from both fuel tanks to allow visual inspection of tank prior to the carriage of passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2016
Resolution: Installed new fuel tanks
Engineering › Fuel Oil Service System › Suction Strainer
Issued 29 September 2016 Resolved
Install marine type fuel strainer to the satisfaciton on attending marine inspector
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 3 November 2016
Resolution: Installed marine type strainer
Communications › Radio Communications › VHF Radiotelephone
Issued 27 September 2016 Resolved
Connect VHF-DSC to GPS input
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: New VHF installed with integrated GPS.
Communications › Radio Communications › EPIRB
Issued 8 January 2016 Resolved
EPIRB hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 19 January 2016
Resolution: New Hydrostatic release had been installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 January 2016 Resolved
Vessel did not have valid alcohol test strips on board. Limited to within 1 hour from the dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 19 January 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 8 January 2016 Resolved
Vessel must provide proof of marine radio operators permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 January 2016 Resolved
Lifering Bouy was not properly configured with line and light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Resolution: Added second line with corrosion resistant clip for floating water light.
Lifesaving › Hand Flares › Quantity
Issued 8 January 2016 Resolved
Vessel had only 6 of required 12 approved flares on board
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Resolution: 6 additional flares acquired.