MAURY USCG vessel records Sign in
← All vessels

EASY DIVER

EASY DIVER is a 1991 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1991, most recently in June 2022, along with 188 deficiencies — 1 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2013.

Records from 1991 to 2022. Most recent: inspection, 16 June 2022.

Built
1991
Last inspected
16 June 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ2033
363079
Flag
UNITED STATES
367555140
Maury page id
psix-363079

Inspections, by type

…with no type recorded2
Years with a record 28 calendar years (1991–2022)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
7 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDN7882MMSI 367555140 · active · compulsorily equipped · granted 6 May 2023, expires 6 May 2033
WDG6263MMSI 367555140 · expired · compulsorily equipped · granted 4 December 2012, cancelled 4 February 2023
WCZ2033MMSI not assigned · expired · voluntarily equipped · granted 14 April 1999, cancelled 20 June 2009
WAX7046MMSI not assigned · expired · compulsorily equipped · granted 18 June 1997, cancelled 7 October 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

16 June 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7479383
8 March 2021 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7148051
6 November 2020 Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7114897
15 September 2020 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7023501
15 November 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6855825
28 August 2018 Deficiency Check · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6496709
12 December 2017 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6325052
4 October 2016 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6015646
27 September 2016 Drydock Exam · Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6013425
8 January 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5793479
25 February 2012 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 4251441
19 December 2011 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4212775
1 December 2011 Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4199436
16 December 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3911787
23 September 2010 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3855621
19 September 2008 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3327981
31 January 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2865582
31 May 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2666043
16 May 2006 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2650618
11 August 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2456171
18 February 2005 Hull Examination · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2292352
19 July 2004 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2134183
5 May 2004 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2058668
7 October 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1950335
8 July 2003 Administrative Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1856698
13 May 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1792124
13 August 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1661033
17 April 2002 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1598957
8 May 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1065057
1 May 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406920
13 April 2000 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1451539
3 March 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1448087
13 April 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421642
22 May 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1128722
21 May 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1127803
29 April 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 793378
9 December 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113531
14 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 774691
7 August 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1118473
14 May 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775121
7 May 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1095715
3 July 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1088583
22 May 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1083418
17 April 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1079853
17 May 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926377
17 April 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850095
10 May 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 859190
12 April 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1168142
30 June 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1155072
24 November 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1141345
13 August 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957311
8 July 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262985
9 October 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 936376
3 July 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1248558
28 June 1991 Deadweight Survey · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1247086

Deficiency record · 188

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 June 2022 No resolution recorded
Vessel failed to conduct an Annual Inspection within 90 days before or after its anniversary date and was issued a prior to carrying passenger deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2021 Resolved
Fire boy system is not functioning properly to provide override function as well as audible and visual alarms. Ensure that fireboy system is properly functioning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2021 Resolved
Both the automatic bilge pumps and the high water alarms need to be repaired. Pumps must function in coordination with float switch and have a visual indicator at the operating station. High water alarms must have both an audible alarm and a visual indicator at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 March 2021 Resolved
Tiller for the emergency steering is inadequate. Ensure that vessel is able to be maneuvered with emergency tiller arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021 Resolved
Vessel's engine noise prevents clear communication between master and deck hand during recovery of persons overboard and or emergency steering scenareo. Provide means for effective communication between crew members in case of emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 September 2020 Resolved
Vessel has significant structural damage to the deck from delamination and wood rot of structural members. Deck must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2020
Resolved 8 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2020 Resolved
The port and starboard fuel tanks are encased in fiberglass. The visible sections of the tank show significant corrosion. Make entire tanks available for inspection, pressure test,or replace tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2020
Resolved 19 January 2021
Resolution: new approved tank installed in vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019 Resolved
Repair/replace lifefloat, L/F is faded and no longer orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 November 2019 Resolved
Preengineered fixed firefighting system once discharged must allow for the vessels engine to restart. During the test oft he FIREBOY the engine was unable to restart after the simulated discharge and continued to read as discharged. Perform successful test in the presence of the local Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2019
Resolution: Oprationally tested, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 November 2019 Resolved
Ring Buoy must meet the specifications listed in 46 CFR 160.050 and must be fitted with a 5/16 buoyant life line at least 60ft in length that is non-kinking breaking strength of at least 1124 lbs and of dark color. Ring Buoy did not meet the above specifications. Replace, ring buoy and line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2019
Resolution: New ring buoy added.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 November 2019 Resolved
Floating water light must have a 3 ft lanyard with a corrosion resistant clip to allow for quick disconnect. Replace line and install a clip on ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Lanyard provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 November 2019 Resolved
Battery for water-light attached to ring buoy was not marked with an expiration date. Due to lack of expiration date the battery must be replaced. All batteries are to be replaced every 2 years at a minimum.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Battery replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 November 2019 Resolved
COI and Stability letter must be posted. Post COI in passenger area and the Stability letter near the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Documents provided and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2019 Resolved
01 Adult life jacket torn and condemned. Replace and properly mark 01 new Adult Life Jacket. Passenger count limited to 21.
Action required: 705 - Other - as specified
Resolved 18 November 2019
Resolution: New PFD provided.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 15 November 2019 Resolved
First Aid kit must contain the contents identified in 46 CFR 160.041. Ammonia Inhalants were expired or no longer marked with expiration date. Replenish First aid kit contents with non expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 November 2019 Resolved
Conduct man overboard and fire drill in the presence of a Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 November 2019 Resolved
Vessel must have adequate and up to date publications on board. Vessel did not have a Coast Pilot, light list and tide tables. Vessel did not have the required publications on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2019 Resolved
Electrical installations must conform to Sub-chapter T. Fuses under the operating station were not of the required cartridge type , numerous dead end wires were not properly terminated or removed and the use of alligator clamps in the overhead by the radio are not authorized. Replace fuses with the appropriated type fuses, properly terminate or remove dead end wires and make all electrical connections are permanent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 18 November 2019
Resolution: Wiring corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2019 Resolved
Replace submersible bilge pump in lazarette space with pump that meets requirements of UL 1113.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Provide securing devices, new gasket, and hinges or device to secure hatch to vessel to prevent its loss for Engine Room hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Hatches secured and gasket applied.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Provide device to secure hatch to vessel to prevent its loss for lazarette and battery compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 November 2019 Resolved
Watertight hatches must have means to be secured to deck, lazarette and battery compartment have the capability to be secured but tool is not currently on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Latches secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2019 Resolved
Join fuel tank fill pipe to fuel tank with a conductor (wire) on both tanks for the protection against generation of static charge when fueling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Bonding wires provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2019 Resolved
Remove excess oil from bilge in forward compartment
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Oil removed
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2019 Resolved
Repair engine oil leak, engine is leaking oil at the top rear of cylinder head
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Oil cleaned up and hose clamp applied to blowoff valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 November 2019 Resolved
Repair/replace exhaust lagging (insulation) in way of cooling water injection
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 November 2019 Resolved
Provide a mast and stern navigation light that meet visibility requirements set forth in 33 CFR 83.22, vessels over 12 meters shall have a stern and mast light independent of the all-around white light (rule 23). Day time operations only.
Action required: 705 - Other - as specified
Resolved 26 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2019 Resolved
Replace hose clamp on raw water intake hose in way of impeller pump on engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Clamp replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2019 Resolved
Close all bulkhead penetrations in engine room, space protected by fixed fire extinguishing equipment (fireboy) shall be able to contain fire agent and not leak into other compartments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 26 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2018 Resolved
Draw shaft and conduct run out test with dial indicator. Provide results to local OCMI, to include the maximum reading recorded from the gauge.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Shaft run out results were .010, vessel owner replaced shaft in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 September 2018 Resolved
Install 6 inch coaming on weather deck at entrance to forward compartment to ensure watertight integrity.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: 6" coaming installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018 Resolved
Repair/replace steel rudder post frame; framing is wasted and no longer structurally sound for supporting the steering system.
Action required: 705 - Other - as specified
Resolved 27 September 2018
Resolution: Rudder post frame completely replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018 Resolved
Repair/replace diesel engine port aft motor mount; mount is wasted with large amount of scaling rust.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All 4 mounts replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018 Resolved
Replace sea valve for raw water pickup for engine cooling located in the port-side of engine room. Valve was unable to move to the closed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 27 September 2018
Resolution: Valve repaired and is functioning properly, photos attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2018 Resolved
Replace screw down stop valve on port overboard discharge pipe for submersible bilge pump located in battery compartment. Valve is wasted and unable to be moved.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: valve replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 September 2018 Resolved
Repair/replace port side longitudinal deck beam in lazarette space. 2x4 is rotted, submit repair proposal to local OCMI prior to conducting repairs.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All deck beams aft of engine room were replaced and deck from engine room deck hatch aft was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2018 Resolved
Clean and make ready for inspection all fuel hose fittings. Fittings at emergency shut offs, fuel strainer and fuel tank were heavily rusted and may not be serviceable.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Fuel lines cleaned and remain serviceable.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 September 2018 Resolved
Sand down areas on weather deck identified by inspector and have ready for re-inspection. Soft spots on weather deck may be a result of de-laminating FRP.
Action required: 705 - Other - as specified
Resolved 21 September 2018
Resolution: Vessel made area available for inspection. New 835v issued to remove entire aft deck and replace to original strength.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 September 2018 Resolved
Seal/close all bulkhead and deck penetrations in Engine Room to ensure agent for per-engineered fixed gas fire extinguishing system does not escape protected area in the event of a manual or automatic activation.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: All penetrations in bulkheads have been sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 September 2018 Resolved
Remove "[name withheld]" from under deck and deck beams in Engine Room and make available for inspection.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Beams cleaned up and remain serviceable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Remove all dead-end wiring in vessel (Battery compartment).
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Wiring cleaned up and dead-ended wires have been removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Removal all oily waste from bilge, excessive accumulation observed in battery and engine room bilge.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: bilges cleaned and free of oily residue.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Conduct underway sea trails with attending Marine Inspector to observe proper operation of steering and propulsion systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2018
Resolution: Satisfactory sea trials conducted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2018 Resolved
Equip vessel with 03 fire buckets 2.5 gallons, labeled fire bucket with attached line
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: aquired 3rd bucket, drilled holes at 2.5 gallon mark and attached lanyards
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2018 Resolved
demonstrate proper operation of preengineered fire extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: properly operated the fireboy system
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 August 2018 Resolved
have updated charts of large enough scale aboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: new updated paper charts onboard
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 August 2018 Resolved
replace line from life float to waterlight/bouy light
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: replaced line to water light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 August 2018 Resolved
attach lifefloat to float free link
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: attached lifefloat to floatfree link
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2018 Resolved
post COI and Stability letter
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Documents posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 August 2018 Resolved
post life jacket donning procedures
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Donning instructions posted.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 28 August 2018 Resolved
post emergency instructions
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2018
Resolution: Emergency Instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 28 August 2018 Resolved
replace hydrostatic release on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2018
Resolution: replaced hydrostatic release on EPIRB
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 August 2018 Resolved
Aft deck is of sandwich construction with foam core after a previous replacement. Forward deck is intact and serviceable with original glass over marine grade plywood. Remaining aft (foam core) deck around cut out for deck beams has core separation and must be removed and replaced as original (glass over marine grade plywood) from transom to engine room bulkhead. Must be repaired prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2018
Resolved 5 November 2018
Resolution: Deck replaced from engine room hatch cover to transom.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 December 2017 Resolved
Remove oil from bilge and port battery boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Excess oil was removed from bilge and battery boxes.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 December 2017 Resolved
Make doors and penetrations in engine room bulkhead vapor tight. Area currently exceeds coverage area of Fire Boy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Openings in engine room have been made vapor tight.
Lifesaving › Lifefloat › Serviceable
Issued 12 December 2017 Resolved
Make repairs to life float in accordance with manufacturers instructions. Vessel restricted to operating no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Life float repaired in accordance with manufacturers instructions.
Construction/Loadline › Structures › Deck Plating
Issued 12 December 2017 Resolved
Make repairs to deck in way of fuel tank compartment.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Repaired deck.
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2017 Resolved
Provide means to secure fuel from starboard fuel tank.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Changed configuration of valve handle to allow valve to be closed.
Engineering › Bilge Water Management System › Pump
Issued 12 December 2017 Resolved
Provide proper operation of automatic bilge pumps and high level alarms. Excessive oil in bilge prevented testing.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Proved proper operation of pumps and alarms.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 December 2017 Resolved
Make engine room hatch watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Engine room hatch was gasketed and screwed in place.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2017 Resolved
Make repairs to deck rails.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Reinforced stanchions at deck connection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 December 2017 Resolved
Provide required amount of portable extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 15 December 2017
Resolution: Owner provided an additional B-I portable fire extinguisher.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 December 2017 Resolved
Make collision bulkhead watertight.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Reinstalled cover on access opening.
Lifesaving › Lifefloat › Paddle
Issued 12 December 2017 Resolved
Lash paddles to life float.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Paddles are lashed to lifefloat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2017 Resolved
Replace battery in life ring light. Vessel restricted to daylight operations.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 12 December 2017
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 December 2017 Resolved
Renew reflective tape on all PFDs.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Replaced reflective tape on all PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 December 2017 Resolved
Renew 03 child size PFDs.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Provieded 03 new child size PFDs
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2017 Resolved
Properly support all electrical cables throughout vessel.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Bundled and supported cables.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 December 2017 Resolved
Label indicators for high level and automatic bilge pumps.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Labeled indicators.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2017 Resolved
Life ring light must have lanyard 3' to 6' secured around body of life ring.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Replaced lanyard.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 12 December 2017 Resolved
Repair oil leaks on engines.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 26 December 2017
Resolution: Repaired oil leaks.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 December 2016 Resolved
Remove oil from all bilges
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2016
Resolution: All oil was removed from bilges
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 December 2016 Resolved
Provide audible alarm for FireBoy
Action required: 705 - Other - as specified
Due 12 December 2016
Resolved 12 December 2016
Resolution: Installed Fireboy switch
Engineering › Bilge Water Management System › Not Operational
Issued 5 December 2016 Resolved
Prove proper operation of automatic bilge pump in holding tank space
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 18 January 2017
Resolution: Owner proved operation of bilge pump.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 December 2016 Resolved
Prove proper operation of visual indicator of v berth automatic bilge pump
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 18 January 2017
Resolution: Owner proved proper operation of indicator of automatic bilge pump.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 December 2016 Resolved
Vessel must have complete first aid kit at all times
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 30 December 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 5 December 2016 Resolved
Label all high water alarms
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 18 January 2017
Resolution: All high water alarms (03) labeled.
Electrical › Electric Supply System (service) › Cable
Issued 5 December 2016 Resolved
Remove all dead ended wire from under console
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 18 January 2017
Resolution: Dead ended wiring has been removed.
Engineering › Fuel Oil Service System › Hose
Issued 5 December 2016 Resolved
Provide documentation that fuel hoses and fittings meet SAE J1942 and SAE J1475
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: Documentation provided.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2016 Resolved
Post COI/Stability Letter
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: COI/Stability Letter posted
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 September 2016 Resolved
Remove FRP from both fuel tanks to allow visual inspection of tank prior to the carriage of passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2016
Resolution: Installed new fuel tanks
Engineering › Fuel Oil Service System › Suction Strainer
Issued 29 September 2016 Resolved
Install marine type fuel strainer to the satisfaciton on attending marine inspector
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 3 November 2016
Resolution: Installed marine type strainer
Communications › Radio Communications › VHF Radiotelephone
Issued 27 September 2016 Resolved
Connect VHF-DSC to GPS input
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 8 March 2017
Resolution: New VHF installed with integrated GPS.
Communications › Radio Communications › EPIRB
Issued 8 January 2016 Resolved
EPIRB hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 19 January 2016
Resolution: New Hydrostatic release had been installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 January 2016 Resolved
Vessel did not have valid alcohol test strips on board. Limited to within 1 hour from the dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 19 January 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 8 January 2016 Resolved
Vessel must provide proof of marine radio operators permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 January 2016 Resolved
Lifering Bouy was not properly configured with line and light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Resolution: Added second line with corrosion resistant clip for floating water light.
Lifesaving › Hand Flares › Quantity
Issued 8 January 2016 Resolved
Vessel had only 6 of required 12 approved flares on board
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2016
Resolved 19 January 2016
Resolution: 6 additional flares acquired.
Documentation › Certificates/Documents › FCC SSL
Issued 19 December 2011 Resolved
Acquire valid FCC radio station license.
Due 31 December 2011
Resolved 19 December 2011
Lifesaving › Hand Flares › Quantity
Issued 19 December 2011 Resolved
Acquire 02 Flares
Due 22 December 2011
Resolved 19 December 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 December 2011 Resolved
Life ring buoy must have 3-6 ft of 5/16 line attached to strobe & 60 ft of 5/16 line attached to ring buoy.
Due 22 December 2011
Resolved 19 December 2011
Engineering › Bilge Water Management System › Interface Detector
Issued 19 December 2011 Resolved
Forward high water level alarm must be operational & visual/audible when alerting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2011
Resolved 19 December 2011
Stability › Watertight Integrity › General
Issued 19 December 2011 Resolved
Deck hatches must be attached to deck openings
Due 22 December 2011
Resolved 19 December 2011
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 19 December 2011 Resolved
Replace sanitation suction hose off MSD
Due 22 December 2011
Resolved 19 December 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 December 2011 Resolved
Install battery box covers on 03 engine batteries.
Due 22 December 2011
Resolved 19 December 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 December 2010 Resolved
Compass light must have the ability to be illuminated during nightime operation. Vessel is restricted to daylight operation until cleared.
Due 23 December 2010
Resolved 18 December 2010
Resolution: New compass illuminates properly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 December 2010 Resolved
Segregate child PFD's from adult PFD's.
Due 23 December 2010
Resolved 17 December 2010
Resolution: Child PFD''s placed in a bag seperate from adult.
Documentation › Certificates/Documents › Stability Letter
Issued 16 December 2010 Resolved
Post stability letter in a conspicuous place onboard.
Due 23 December 2010
Resolved 17 December 2010
Resolution: Stability letter posted along with COI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 December 2010 Resolved
Secure vessel passenger seating area properly to deck.
Due 23 December 2010
Resolved 18 December 2010
Resolution: Passenger seating area secured to deck.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 16 December 2010 Resolved
Engine room doors must be secured during operation of vessel.
Due 23 December 2010
Resolved 17 December 2010
Resolution: Door latch repaired and secured.
Communications › Radio Communications › EPIRB
Issued 16 December 2010 Resolved
Register EPIRB with NOAA.
Due 23 December 2010
Resolved 23 December 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 December 2010 Resolved
Repair fractures in passenger seating area. (rails)
Due 23 December 2010
Resolved 23 December 2010
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 16 December 2010 Resolved
Install new flame screens on fuel vents.
Due 23 December 2010
Resolved 18 December 2010
Resolution: New flame screens installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 December 2010 Resolved
Replace expired medication in first aid kit.
Due 23 December 2010
Resolved 18 December 2010
Resolution: Expired medication replaced in first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 16 December 2010 Resolved
Replace lifefloat and painter line prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2010
Resolved 18 December 2010
Resolution: Lifefloat and painter line replaced.
Lifesaving › Lifefloat › Paddle
Issued 16 December 2010 Resolved
re-label lifefloat paddles.
Due 23 December 2010
Resolved 17 December 2010
Resolution: Paddles re-labeled.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 September 2008 Resolved
Prove proper operation of the bilge high level audible and visual alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2008
Resolved 24 September 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 September 2008 Resolved
Properly mount portable fire extinguishers.
Due 1 October 2008
Resolved 30 September 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 September 2008 Resolved
Label remote fuel shutoff valve locations.
Due 1 October 2008
Resolved 30 September 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 September 2008 Resolved
Post lifejacket donning placards.
Due 1 October 2008
Resolved 30 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 September 2008 Resolved
Label location, type and quantity of lifejackets.
Due 1 October 2008
Resolved 30 September 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 September 2008 Resolved
Make proper repairs to the starboard side deck rail as discussed.
Due 1 October 2008
Resolved 30 September 2008
Construction/Loadline › Structures › Manhole
Issued 19 September 2008 Resolved
Install tether on engine room hatch.
Due 1 October 2008
Resolved 30 September 2008
Engineering › Steering Gear System › Rudder
Issued 19 September 2008 Resolved
Demonstrate and provide training on emergency steering arrangements.
Due 1 October 2008
Resolved 30 September 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 September 2008 Resolved
Vessel failed to have a valid USCG COI on board vessel, < 1600 GT. COI expired without renewal examination being conducted and the vessel operated with passengers during that time.
Due 25 September 2008
Resolved 30 September 2008
Communications › Alarms/Indicators › High Water Alarm
Issued 8 June 2006 Resolved
Provide visual indicators at operating station for high water level bilge alarm.
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 June 2006 Resolved
Provide life line to ring lifebouy IAW 46 CFR 180.70(c)(6).
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2006 Resolved
Provide lanyard for ring lifebouy waterlight IAW 46 CFR 180.70(d)(2).
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Lifesaving › Visual Distress Signals (General) › Expired
Issued 8 June 2006 Resolved
Provide (03) red distress signal flares and (05) orange distress signal flares IAW 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2006
Lifesaving › Lifefloat › Paddle
Issued 8 June 2006 Resolved
Label lifefloat paddles with vessel name IAW 46 CFR 180.175(f)(2)
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Lifesaving › Lifefloat › Lifeline
Issued 8 June 2006 Resolved
Replace grablines on lifefloat IAW 46 CFR 180.175(e)(1).
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Lifesaving › Lifefloat › Serviceable
Issued 8 June 2006 Resolved
Repair lifefloat with manufactorer's repair kit.
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 9 June 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 June 2006 Resolved
Replace retro-reflective tape for lifefloat where specified by Marine Inspector IAW 46 CFR 164.108.
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 9 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 June 2006 Resolved
Replace retro-reflective tape on (03) child size lifejackets IAW 46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 June 2006 Resolved
Provide proof of annual servicing on all fire fighting equipmement IAW 46 CFR 176.810(a)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 June 2006 Resolved
Provide lifejacket donning placard IAW 46 CFR 185.516(a).
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 11 July 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 8 June 2006 Resolved
Replace emergency steering tiller IAW 46 CFR 182.620(a)(3)(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2005 Resolved
Complete Emergency Broadcast Placard with proper information.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 13 July 2018
Resolution: Item completed prior to completion of inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 July 2004 Resolved
Ensure that all Portable Fire Extinguishers are serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: New extiguishers were purchased.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 19 July 2004 Resolved
Ensure that fixed fire extinguisher is serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 20 July 2004
Resolution: Service invoice indicates work performed on 10/23/03.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 July 2004 Resolved
Mark both Emergency Fuel Shut-Off valves.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 8 September 2004
Resolution: New lettering installed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 19 July 2004 Resolved
Remove all oily water from bilges.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 19 July 2004
Resolution: All oily water was removed so that bilge pumps may be tested
Engineering › Bilge Water Management System › Interface Detector
Issued 19 July 2004 Resolved
Ensure proper operation of all bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: Service technician arrived at vessel as exam was completed. During deficiency check all alarms were operational.
Engineering › Bilge Water Management System › Pump
Issued 19 July 2004 Resolved
Ensure proper operation of all bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: All bilge pumps were satisfactorily tested once oily water was removed from the bilge.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 July 2004 Resolved
Provide a battery cover for port engineroom battery bank.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 19 July 2004
Resolution: A wooden cover was fabricated and installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 July 2004 Resolved
Submit a repair proposal for wasted area on starboard fuel tank IWO fuel return line connection. Once approved make repairs in accordance with approved plan.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: Requirement was cleared and re-issued as MR10 during deficiency follow-up.
Stability › Watertight Integrity › General
Issued 19 July 2004 Resolved
Provide a latching mechanism to engineroom cover or by other means ensure that cover remainswatertight while passengers are on board.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: Screws for the engine compartment hatch were installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 July 2004 Resolved
Repair or replace wasted starboard fuel tank. Prior to repare or replacement, owner must submit plans for approval. Repair or construction of fuel tank shall be monitored by the cognizant OCMI. Vessel may operate during construction or prior to repair only if starboard tank is empty of fuel and isolated.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 8 September 2004
Resolution: Successfully hydro-tested repairs to fuel tank.
Communications › Radio Communications › EPIRB
Issued 13 May 2003 Resolved
Renew battery and hydrostatic release for EPIRB prior to carrying passengers beyond 3NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 3 June 2003
Resolution: Received a faxed copy of the receipt for purchase of a new battery and hydrostatic release.
Operations/Management › Drills/Instruction
Issued 13 May 2003 Resolved
Provide Emergency Broadcast Placard and affix near operating station not later than 13Jun03 LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 8 July 2003
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 13 May 2003 Resolved
Install a corrosion resistant clip to life-light lanyard to life ring buoy not later than 30Jun03. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 8 July 2003
Resolution: Corrected.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 May 2003 Resolved
Ensure both B-II portable fire extingushers are serviced prior to carrying passengers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2003
Resolved 14 May 2003
Resolution: Received fax copy of the envoice for the purchase of two new B-II portable fire extinguishers.
Communications › Alarms/Indicators
Issued 18 April 2002 Resolved
Repair engine room high level alarm. LEGACY COMPONENT DESC: High Water Alarm
Condition: Unknown
Due 18 May 2002
Resolved 16 July 2002
Resolution: Resolved.
Lifesaving › Buoyant Apparatus
Issued 18 April 2002 Resolved
Repair or replace 15 person life float. If repairing, use manufacturer's approved patch kit.
Condition: Improper/Lack of Maintenance
Due 18 May 2002
Resolved 16 August 2002
Resolution: Corrected. Replaced old life raft with new.
Communications › Alarms/Indicators
Issued 18 April 2002 Resolved
Install/connect visual and audible high level alarms at operating station. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Due 18 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Construction/Loadline › Structures
Issued 18 April 2002 Resolved
Install mesh or netting between aft railing so that no space is greater than 4 inches from the top most chain, to the main deck.
Condition: Improper Installation
Due 18 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Engineering
Issued 1 May 2001 Resolved
Replace raw-water intake hose for main engine & repair/renew cooling hose from the main engine JABSCO Pump.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Construction/Loadline
Issued 1 May 2001 Resolved
Provide lanyard for # 2 compartment watertight hatch.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 1 May 2001 Resolved
Replace ring buoy.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 1 May 2001 Resolved
Make L/F float free & provide paddles.
Condition: Unknown
Due 1 May 2001
Resolved 7 May 2001
Lifesaving
Issued 1 May 2001 Resolved
Replace retro-reflective tape on 3 child and 1 adult PFD(s).
Condition: Unknown
Due 1 May 2001
Resolved 7 May 2001
Fire Fighting
Issued 1 May 2001 Resolved
Provide receipt for portable & fixed fire system servicing, including checkof auto-shutdown, alarm, & override.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 13 April 2000 Resolved
Properly affix ring buoy with 60' line, 3-6' line to waterlight and replacename.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Lifesaving
Issued 13 April 2000 Resolved
re-name & replace retro on L/F.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 13 April 2000 Resolved
Mark emergency fuel shutoff location.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Construction/Loadline
Issued 13 April 2000 Resolved
Re-route wiring and close bulkhead between engineroom and generator room.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Lifesaving
Issued 13 April 2000 Resolved
Develop/start log for drills & monthly inspection of L/S equipment-EPIRB Testing.
Condition: Unknown
Due 13 April 2000
Resolved 14 April 2000
Lifesaving
Issued 13 April 2000 Resolved
Develop and post emergency procedures IAW 46 CFR Part 185.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Fire Fighting
Issued 13 April 1999 Resolved
Install fixed fire fighting system prior to 30APR99.
Condition: Unknown
Due 30 April 1999
Resolved 7 May 1999
Construction/Loadline
Issued 13 April 1999 Resolved
Install high water alarms system prior to 30APR99.
Condition: Unknown
Due 30 April 1999
Resolved 7 May 1999
Lifesaving
Issued 13 April 1999 Resolved
Vessel is to conduct emergency drills in presence of Marine Inspector.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Lifesaving
Issued 21 May 1998 Resolved
AFFIX NEW LINE ON LIFE RING BUOY.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Construction/Loadline
Issued 21 May 1998 Resolved
REPAIR/REPLACE AFT BILGE PUMP.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Lifesaving
Issued 7 May 1997 Resolved
Renew all 6 red hand held flares.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 7 May 1997 Resolved
Renew paddles for lifefloat.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Documentation
Issued 7 May 1997 Resolved
Renew FCC Radio Safety Cert.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Electrical
Issued 22 May 1996 Resolved
Replace all defective electrical gauges for installed service generator._x001C_ (ammeter, voltmeter, frequency meter)
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Lifesaving
Issued 17 April 1995 Resolved
Replace 3 outdated orange smoke signal flares prior to operation with passengers.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Replace ring life buoy and 60' line.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
Replace defective amp meter and frequency meter on Ship Service AC Gen.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Replace paddles and lash them to the lifefloat.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Fire Fighting
Issued 17 April 1995 Resolved
Replace or have serviced B-II fire extinguisher prior to the carriage of passengers.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Navigation
Issued 17 April 1995 Resolved
Repair VHF-FM radio prior to the carriage of passengers.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Construction/Loadline
Issued 8 July 1992 Resolved
REPLACE MSD SEA WATER HOSE WITH WIRE REINFORCED TYPE.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Documentation
Issued 8 July 1992 Resolved
POST EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Construction/Loadline
Issued 8 July 1992 Resolved
REPLACE SEA STRAINER TO GENERATOR.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Navigation
Issued 8 July 1992 Resolved
REPAIR PORT SIDELIGHT.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Accommodation/Occupational Safety
Issued 3 July 1991 Resolved
PROVIDE MINIMUM 36" HIGH RAILINGS WITH MAXIMUM OF 12" HORIZONTAL COURSES FOR PROTECTION OF PASSENGERS AND CREW AT BOW.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Accommodation/Occupational Safety
Issued 3 July 1991 Resolved
PROVIDE 36" HIGH RAILINGS ACROSS STERN. (MEASURED FROM DECK)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1991
Resolved 17 October 1991
Documentation
Issued 3 July 1991 Resolved
POST STABILITY LETTER, CERTIFICATE OF INSPECTION AND FCC CERTIFICATES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1991
Resolved 17 October 1991
Documentation
Issued 28 June 1991 Resolved
PERMANTLY MARK VESSEL'S OFFICIAL NUMBER IN A CLEARLY VISIBLE INTERIOR PART OF HULL PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Documentation
Issued 28 June 1991 Resolved
POST STABILITY LETTER UPON RECEIPT FROM MARINE SAFETY CENTER NOT LATER THAN28JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Construction/Loadline
Issued 28 June 1991 Resolved
INSTALL CAPTIVE CHAINS ON DECK HATCHES PRIOR TO CARRYING PASSENGERS AND NOTLATER THAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Lifesaving
Issued 28 June 1991 Resolved
STENCIL PFD LOCKERS PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Electrical
Issued 28 June 1991 Resolved
PROVIDE NAME PLATE FOR GENERATOR STATING CAPACITY HAS BEEN DERATED TO 80% OF FULL LOAD IAW 46 CFR 183.10-5 PRIOR TO CARRYING PASSENGERS AND NOT LATERTHAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Electrical
Issued 28 June 1991 Resolved
DEMONSTRATE PROPER OPERATION OF OIL PRESSURE & WATER TEMP GAUGES AND VOLT METER (DC) FOR S/S GENERATOR PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Construction/Loadline
Issued 28 June 1991 Resolved
PROVIDE ADDITIONAL FREEING PORT AREA TO OBTAIN A MINIMUM OF 136 IN 2, IAW 46 CFR 171.150 PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 05JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Documentation
Issued 28 June 1991 Resolved
PROVIDE FCC CERTIFICATE. VESSEL LIMITED TO NOT MORE THAN 1000 FT FROM SHORE UNTIL COMPLETED. TO BE COMPLETED NOT LATER THAN 28JUL91.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991

Casualty record · 1

6 March 2013Routine · role: Involved in a Marine Casualty · activity 4549235
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.