← All vessels
STELLAR DREAM
STELLAR DREAM is a 1991 freight ship. The Coast Guard has recorded 28 inspections since 1991, most recently in March 2007, along with 9 deficiencies and 6 operational controls.
Records from 1991 to 2007. Most recent: inspection, 9 March 2007.
- Built
- 1991
- Last inspected
- 9 March 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9000431 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EUM8
363225
Flag
PANAMA
—
Maury page id
psix-363225
Inspections, by type
…with no type recorded21
Years with a record
16 calendar years (1991–2007)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it44831 - Dead Weight, Ton
19442 - Convention (Subpart B), Net Ton
38844 - Convention (Subpart B), Gross Ton
19442 - Convention (Subpart B), Net Ton
38844 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
9 March 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2885090
24 February 2006
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2591504
29 September 2005
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2504146
17 August 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2466049
5 April 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2563353
3 December 2004
PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2252573
30 November 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2250669
6 November 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2236004
30 August 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2180890
11 February 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2004553
11 December 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1962805
25 March 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 288492
25 July 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 280142
11 September 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 432674
30 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 422019
27 April 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 414894
16 July 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 405194
21 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401704
9 October 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395822
6 December 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385016
1 July 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 379985
6 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 371896
6 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142869
30 August 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 512372
6 January 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 363607
17 August 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 453315
3 September 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 461350
22 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 343911
Deficiency record · 9
Engineering › Sea-water System (primary cooling)
Issued 11 December 2003
Resolved
Leaking temporary patch located at (Inside) elbow in main engine lube oil cooler, port side aft E. R. bottom deck. Repair to the satisfaction flag state surveyor. ILLC 66 ANNEX 1/15 LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 11 December 2003
Resolved
Discharge line on #1 salt water service pump thin/wasted. Replace discharge piping between pump and first valve. (Stbd ER Aft bottom deck) Replace to the satisfaction of flag state surveyor. ILLC 66, ANNEX 1/15 LEGACY COMPONENT DESC: Piping
Fire Fighting
Issued 21 March 1997
Resolved
PROVIDE A GASKET MADE OF SUITIBLE MATERIAL FOR THE INTERNATIONAL SHORE CONNECTION._x001C_ SOLAS 74(AMENDED) II-2/19.4
Fire Fighting
Issued 21 March 1997
Resolved
PERFORM A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74(AMENDED) III/18.3.4-3.9/SOLAS 74(AMENDED) III/18.3.10-3.13
Fire Fighting
Issued 6 December 1995
Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 (AMENDED)II-2/20
Lifesaving
Issued 6 December 1995
Resolved
PROVIDE/POST VESSEL MUSTER LIST IN ENGINE ROOM CONTROL ROOM. SOLAS 74 AMENDED III/8.3
Lifesaving
Issued 6 December 1995
Resolved
Poster or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall: Illustrate the purpose of controls and the procedures for operating the appliance. In accordance with SOLAS 74 III/9.2
Lifesaving
Issued 6 December 1995
Resolved
REPLACE ALL DEFECTIVE LIFERING BUOYS THROUGHOUT VESSEL. SOLAS 74 AMENDED III/19.2
Fire Fighting
Issued 6 January 1994
Resolved
Fire hoses burst when placed under pressure.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.