REEFDANCER is a 1991 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1991, most recently in August 2023, along with 114 deficiencies and 1 casualty investigation in 2023.

Records from 1991 to 2023. Most recent: inspection, 9 August 2023.

Built
1991
Last inspected
9 August 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9759
363329
Flag
UNITED STATES
367751890
Maury page id
psix-363329

Inspections, by type

…with no type recorded9
Years with a record 29 calendar years (1991–2023)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.6 ft × 13.0 ft × 7.6 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN RIVER MANUFACTUR · RANCHO CORDOVA CA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9759MMSI 367751890 · active · compulsorily equipped · granted 23 August 2016, expires 23 August 2026
WCW8815MMSI 367138820 · expired · compulsorily equipped · granted 9 September 2006, cancelled 26 November 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEAVIEW Passenger (Inspected) · MISLE 363390 · 1 November 1993 · activity 60986

Inspection history · 85

9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770042
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7789788
24 January 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7626000
2 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7390712
26 January 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7385124
13 December 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7382175
21 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7127246
5 March 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6925695
26 February 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6916476
27 January 2020 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6897496
15 January 2019 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6610873
19 September 2018 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6544455
10 January 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6335611
23 October 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6294565
4 October 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6015870
5 January 2016 Examination of Repairs · Internal Structural Exam · In-Service Inspection · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5788594
4 August 2015 DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5192778
20 October 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5008742
5 December 2011 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4201903
9 October 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3341578
11 December 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3113525
1 October 2007 Examination of Repairs · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3081114
26 October 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2808684
6 September 2005 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2492702
29 August 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2479064
11 April 2005 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2331617
30 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2250460
14 November 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1947859
14 October 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1927406
8 September 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1900036
11 December 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717737
6 December 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1715097
20 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1711321
4 October 2002 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1684740
6 December 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077407
3 December 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077406
20 September 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384882
28 September 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822842
14 September 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382057
22 October 1999 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378842
30 September 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1115881
27 September 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 110946
27 September 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1352945
12 January 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365006
8 September 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1413407
3 December 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 778282
6 November 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 783335
20 September 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383671
8 September 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383673
16 May 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1116540
17 October 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371561
5 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388039
1 May 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353920
4 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360468
3 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367690
5 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355709
3 November 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414539
28 September 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355515
20 April 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387765
12 January 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1175730
28 October 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 371954
5 October 1994 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358554
7 July 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359853
2 February 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1162676
7 January 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370761
8 December 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 689951
29 November 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 689950
3 November 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396009
1 November 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 60986
1 November 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 62016
16 September 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362856
18 June 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 827301
6 April 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 838222
9 October 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 933772
31 March 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958902
22 October 1991 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1247894
9 October 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 933908
13 September 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1243709
26 August 1991 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936842
25 July 1991 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1245248
28 June 1991 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 933941
22 May 1991 Initial Construction-Excluding Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1222774
3 May 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918297
27 March 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1224481
25 March 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 911267

Deficiency record · 114

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 January 2023 Resolved
A vessel must comply with the structural design requirements for aluminum hull vessels. Courtesy lights along exterior of vessel above the waterline are wired into the interior of the vessel are no longer in use. Fittings that hold the lights are dissimilar metals to aluminum hull and are causing corrosion. Remove lights and fittings, crop and renew holed areas where lights are currently located. Complete at next drydock. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 29 November 2023
Resolution: Vessel destroyed in Lahaina wildfire, deficiency now moot.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 26 January 2022 Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Neither of the two masters onboard had a valid radio operator permit. 47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 21 March 2022
Resolution: MROP Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems must meet SAE J-1942. New fuel hose installed on starboard fuel system. Fuel hose not marked as J-1942. Provide proof that fuel hose meets J-1942. 46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 25 February 2022
Resolution: CG approved hoses provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2022 Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. New ZF Controller installed on vessel. QFA and DVTP not provided and test not completed Provide QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP. 46 CFR 184.620
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 29 March 2022
Resolution: DVTP provided. Tested microprocessor power failure and control head potentiometer failure. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 January 2022 Resolved
The arrangement of a vessel must allow the safe operation of the vessel in accordance with the COI for a seaworthy hull. 02 half inch holes port and starboard on main deck fwd. Make permanent repairs to holes. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 25 February 2022
Resolution: Holes repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2021 Resolved
Valid FCC Safety Radio Certificate not on board. Provide valid FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 22 January 2021
Resolution: FCC Cert Provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2021 Resolved
List of employees not present for means of drug and alcohol testing. Provide list of covered employee list of current employees.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 22 January 2021
Resolution: Employee list provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2021 Resolved
Ring buoy line not 60 ft in length. Provide synthetic UV protected line over 60 ft in length.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 8 February 2021
Resolution: Line provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 January 2021 Resolved
Life jacket and emergency escape markings missing. provide both life jacket and emergency escape markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 8 February 2021
Resolution: Markings provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 January 2021 Resolved
Audible alarm for engine room bilge high water not operational. Provide audible alarm for engine room bilge high water alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2021
Resolution: Bilge high water alarm operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 January 2021 Resolved
Starboard engine raw water hose showing cracks and crushed. Replace starboard engine raw water hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 8 February 2021
Resolution: Hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 February 2020 Resolved
The vessels lifebuoy was unserviceable. Replace in accordance with 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 12 March 2020
Resolution: Replacement lifebuoy purchased and installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2020 Resolved
The engine space centerline high water alarm was not functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 5 March 2020
Resolution: Centerline high water alarm repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 January 2020 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Reinstall all hand rails. Carrying passengers is prohibited until this deficiency has been rectified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2020
Resolution: Newly installed railings satisfactorily inspected by MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2020 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. At the conclusion of all necessary repairs and prior to carrying passengers conduct sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2020
Resolution: Satisfactory seatrial conducted.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 September 2018 Resolved
Engine compartment high water alarm was not functional.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2018
Resolution: Alarm repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 September 2018 Resolved
3 adult PFDs failed inspection. Vessel limited to 42 persons total.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2018
Resolution: PFDs provided.
Electrical › Electric Supply System (service) › Cable
Issued 4 August 2015 Resolved
Properly secure wire runs in engine room.
Due 4 September 2015
Resolved 5 January 2016
Engineering › Fuel Oil Service System › Hose
Issued 4 August 2015 Resolved
Replace STBD MDE fuel supply and return hoses with CG approved hoses. Also replace PORT MDE fuel supply to filter with CG approved hose.
Due 4 September 2015
Resolved 5 January 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2014 Resolved
Ensure first aid kit is properly outfitted and maintained.
Due 20 October 2014
Resolved 20 October 2014
Resolution: New first aid kit was brought on board.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 December 2007 Resolved
POST POLICY STATEMENT AND HOTLINE #.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 20 December 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 December 2007 Resolved
PROVIDE ALCOHOL TESTING DEVICES ON BOARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 20 December 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 December 2007 Resolved
PROVIDE EAP 1 HOUR TRAINING FOR SUPERVISOR OF PROGRAM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 20 December 2007
Deck/Cargo › Towing › Tackle
Issued 1 October 2007 Resolved
Renew fwd tow bit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Engineering › Bilge Water Management System › Piping
Issued 1 October 2007 Resolved
Renew wasted plug for bilge piping located in engine compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Engineering › Bilge Water Management System › Pump
Issued 1 October 2007 Resolved
Renew wasted nipple in bilge line located in engine compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Side Shell
Issued 1 October 2007 Resolved
Grind out fractured weld adjacent to aft bulkhead located in port A/C flat. Make proper repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 October 2007 Resolved
Make proper repair to fractured to stanchion base located in port aft ballast tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Bottom Plating
Issued 1 October 2007 Resolved
Make proper repiar to fracture in hull adjacent to drain hole located in stbd ballast tank aft of fuel tank space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 1 October 2007 Resolved
Submit repair plan for hole located in fwd center tank fwd of collision bulkhead. A minimum 18 x 18 insert required. Provide NDT method for CG approval.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 10 October 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 October 2006 Resolved
Provide current and corrected charts of large enough scale for the AOR that the vessel operates in.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2006
Resolved 26 November 2006
Lifesaving › Lifebuoys › Serviceable
Issued 26 October 2006 Resolved
Renew as original all life rings on the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2006
Resolved 26 November 2006
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2006 Resolved
Check all flexible hose in the engine space, specifically looking at the hoses attached to the generator, and replace as needed all worn hose to meet the SAE J-1492 standard.
Action required: 705 - Other - as specified
Due 26 November 2006
Resolved 26 November 2006
Construction/Loadline › Hull › Hull Plating
Issued 29 August 2005 Resolved
Found crack IWA starboard rub rail. Required to repair crack and investigate possible corrosion from watering being trapped in the space between the rub rail and the hull.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 9 September 2005
Resolution: Corrected
Construction/Loadline › Hull › Weld
Issued 29 August 2005 Resolved
Found 3 fractured welds IWA the forward part of the A/C void. Renew stringer and welds as needed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2005
Resolved 9 September 2005
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 29 August 2005 Resolved
Renew all broken and missing light covers in passenger spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 26 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 November 2004 Resolved
Provide safety mousing on all tack welded life line connection points on deck stantions.
Due 30 December 2004
Resolved 29 March 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 November 2004 Resolved
Provide an current addition of the coast pilot and CG light list.
Due 30 December 2004
Resolved 29 March 2005
Construction/Loadline › Penetrations › Gasket
Issued 30 November 2004 Resolved
Renew gaskets on all weather hatches.
Due 30 December 2004
Resolved 29 March 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 November 2004 Resolved
All life line connection points to be 100% welded at 30 SEP 05 credit drydock. Securing points are tack welded and have shown a history of breaking at the welds.
Due 30 September 2005
Resolved 29 March 2005
Engineering › Fuel Oil Service System › Filter
Issued 30 November 2004 Resolved
Provide plugs for fuel service racor filters in engine room.
Due 30 December 2004
Resolved 29 March 2005
Electrical › Electrical Distribution System (service)
Issued 14 October 2003 Resolved
Properly repair or remove dead end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 1 November 2003
Resolved 14 November 2003
Documentation › Logs/Records
Issued 14 October 2003 Resolved
(EAP) Provide proof of 60 minutes of training for supervisory postions. LEGACY COMPONENT DESC: Drug Test Records
Condition: Improper/Lack of Maintenance
Due 1 November 2003
Resolved 14 November 2003
Operations/Management › Lifesaving
Issued 14 October 2003 Resolved
Provide log for livesaving maintenanance. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Condition: Improper/Lack of Maintenance
Due 1 November 2003
Resolved 14 November 2003
Navigation › Piloting/Steering
Issued 14 October 2003 Resolved
Provide tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Improper/Lack of Maintenance
Due 1 November 2003
Resolved 14 November 2003
Construction/Loadline › Structures
Issued 14 October 2003 Resolved
Provide vent covers for fuel tank space/engine room spaces. Total (4). LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 1 November 2003
Resolved 14 November 2003
Navigation › Piloting/Steering
Issued 20 November 2002 Resolved
Provide US Coast pilot IAW 46CFR184.320. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 20 November 2002 Resolved
Properly repair #1 stanchion stbd side IAW46FCR177.900. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 20 November 2002 Resolved
Remove or properly repair dead end wires located in engine room IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Lifesaving › Buoyant Apparatus
Issued 20 November 2002 Resolved
Replace battery for water light on lifefloat IAW 46CFR185.700. LEGACY COMPONENT DESC: water light battery
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 6 December 2002
Construction/Loadline › Structures
Issued 20 November 2002 Resolved
Provide proper repairs for fractures in conning tower IAW 46CFR179.320. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Engineering › Bilge Water Management System
Issued 20 November 2002 Resolved
Prove proper operation of bilge pump located in engine room and visual alarm located at operating station. LEGACY COMPONENT DESC: Pump
Condition: Placed in Improper Service
Due 4 December 2002
Resolved 6 December 2002
Engineering › Sea-water System (primary cooling)
Issued 20 November 2002 Resolved
Double clamp hoses for vital piping IAW 46CFR182.410. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Engineering › Steering Gear System › Bracket/Clamp
Issued 20 November 2002 Resolved
Properly repair fracture in steering ram bracket IAW 46CFR182.610.
Condition: Unknown
Due 23 November 2002
Resolved 22 November 2002
Documentation › Certificates/Documents
Issued 20 November 2002 Resolved
Provide FCC Station license and FCC Safety permit IAW 46CFR184.420. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 4 December 2002
Resolved 6 December 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 October 2002 Resolved
Replace broken transmission cable for port engine prior to carrying passengers. LEGACY COMPONENT DESC: Transmission cable
Condition: Unknown
Due 4 October 2002
Resolved 4 October 2002
Lifesaving
Issued 3 December 2001 Resolved
Provide signaling devices IAW 46CFR180.68.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2001
Resolved 12 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Provide a complete first aid kit IAW 46CFR184.710.
Condition: Unknown
Due 7 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 3 December 2001 Resolved
Provide an additional B-II fire extinguisher IAW 46CFR176.810.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2001
Resolved 12 December 2001
Electrical
Issued 3 December 2001 Resolved
Prove proper operation of fuse holder IAW 46CFR183.200.
Condition: Unknown
Due 7 December 2001
Resolved 12 December 2001
Navigation
Issued 3 December 2001 Resolved
Prove proper operation of navigation lights IAW 46CFR183.420.
Condition: Unknown
Due 7 December 2001
Resolved 12 December 2001
Lifesaving
Issued 3 December 2001 Resolved
Prove compliance with 46CFR185.420 by completing drills and providing [name withheld] with record on a monthly basis for a three month period. A complete training log is required to be provided to [name withheld] at the end of this three month period.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 March 2002
Resolved 12 December 2001
Construction/Loadline
Issued 14 September 2000 Resolved
Repair/ replace gaskets on all watertight hatches in accordance with 46 CFR176.802/ 171.124.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Construction/Loadline
Issued 14 September 2000 Resolved
Prove proper operation of bilge operating indicator in accordance with 46 CFR 182.520.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Accommodation/Occupational Safety
Issued 14 September 2000 Resolved
Replace missing stanchion for aft railing in accordance with 46 CFR 177.900._x001C_ _x001C_
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Lifesaving
Issued 14 September 2000 Resolved
Maintain adequate lifesaving maitenence logs in accordance with 46 CFR 185.702.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Electrical
Issued 14 September 2000 Resolved
Remove dead end wires in engine room and distribution panel in accordance with 46 CFR 183.340.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Navigation
Issued 14 September 2000 Resolved
Provide navigation publications in accordance with 46 CFR 184.420.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Lifesaving
Issued 14 September 2000 Resolved
Provide a non-corrosive clip for ring lifebuoy waterlight in accordance with 46 CFR 180.70.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Lifesaving
Issued 14 September 2000 Resolved
Provide an operable waterlight for ring lifebuoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 21 September 2000
Resolved 2 October 2000
Electrical
Issued 22 October 1999 Resolved
Remove all dead end wires.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 22 October 1999 Resolved
Provide 3 fire buckets.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 22 October 1999 Resolved
Provide 5gpm portbl blg/fire pump.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Engineering
Issued 27 September 1999 Resolved
Starboard outdrive has been removed from vessel. Do not operate vessel with passengers until repairs effected. Complete appropriate repairs to thesatisfaction of the attending Marine Inspector NLT 03OCT99 IAW 46CFR177.100.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Documentation
Issued 8 September 1998 Resolved
FCC Safety Certificate was expired. Provide proof of FCC Safety certificate and complete satisfactroy operational test of VHF radio in presence of USCG marine inspector.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 8 September 1998 Resolved
Electrical wire was disconnected from E/R bilge high level alarm. Repair high level bilge alarm in E/R.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 8 September 1998 Resolved
Raw water intake hose for the port engine was not of an approved type and asoft spot was noted in the hose. Replace water intake hose to prot engine.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Engineering
Issued 8 September 1998 Resolved
(2) of (4) fuel tank vents did not have flame screens. Provide flame screens for fuel vents.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Fire Fighting
Issued 8 September 1998 Resolved
Fire extinguishers had not been serviced by an approved facility, nor had they been weighed by company personnel. Provide proof of fire fighting servicing report.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Lifesaving
Issued 20 September 1997 Resolved
Label all personal flotation devices with vessel name.
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997
Construction/Loadline
Issued 20 September 1997 Resolved
At next scheduled drydock, gauge hull, and be prepared to crop and renew asnecessary due to corrosion/pitting.
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997
Fire Fighting
Issued 20 September 1997 Resolved
Provide proof of firefighting servicing report.
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997
Construction/Loadline
Issued 20 September 1997 Resolved
At next scheduled drydock, remove all ballast from vessel, to include concrete ballast suspended from hull.
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997
Electrical
Issued 3 April 1996 Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Provide passenger count lists in accordance with 46 CFR 185.504.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Fire Fighting
Issued 3 April 1996 Resolved
Conduct and log fire fighting drills and training in accordance with 46 CFR185.524.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log abandon ship and man overboard drills and training in accordance with 46 CFR 185.520.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 5 March 1996 Resolved
Provide proper flame shields with proper metallic threaded retention bolt and nut for all racor fuel filters.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 5 March 1996 Resolved
Provide a bilge pump operation indicator lights at the bridge steering and an audible bilge high level alarm in addition to the visual alarm at the console to comply with the new subchapter T regulations.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
Repair or install 30x30 mesh flame screens for all fuel tank vents.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
Make permanent repairs to the sea water inlet sea valve spool piece for thestarboard main engine. Spool piece and valve threaded connection is brokenand the valve is now connected with a rubber hose using double clamp connections on both ends.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
Provide machinery guards on the forward ends of both main engines in way ofthe belt drives.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996 Resolved
Fuel system, either replace the rubber hoses with the original metallic piping or change out hoses and replace with an approved type for a commercial vessel. Hoses must comply with SAE J1492. Hoses which meet theSAE J1527 standard are for recreational vessels only.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Lifesaving
Issued 5 March 1996 Resolved
Replace the ring buoy.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Fire Fighting
Issued 5 March 1996 Resolved
Renew the Bridge B-I fire extinguisher. Provide documentation for the lastservicing for all other portable fire extinguishers. Portable fire extinguishers are required to be serviced annually and must have a tag indicating last servicing date.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Electrical
Issued 5 March 1996 Resolved
Provide proper circuit breakers or fuse protection for the macro commander circuit and properly mount on off switches in a metal enclosure.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 20 April 1995 Resolved
Prior to carrying passengers for hire, complete satisfactory engine trials to the masters satisfaction.
Condition: Unknown
Due 20 April 1995
Resolved 4 May 1995
Documentation
Issued 20 April 1995 Resolved
Complete and submit a CG-2692 for engine casualty 19 April 95.
Condition: Unknown
Due 20 April 1995
Resolved 4 May 1995
Documentation
Issued 20 April 1995 Resolved
Upon receipt of Certificate of Inspection, post on vessel.
Condition: Unknown
Due 25 April 1995
Resolved 4 May 1995
Engineering
Issued 5 October 1994 Resolved
REPAIR OR REPLACE AS PER ORIGINAL, GUARDS FOR PULLEY SYSTEMS ON THE PORT AND STARBOARD MAIN DIESEL ENGINES, IN ACCORDACNE WITH 46 CFR 177.35-15.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
PROVE PROPER OPERATION OF VESSEL EMERGENCY LIGHTING, IN ACCORDANCE WITH 46 CFR 184.30-5.
Condition: Unknown
Due 3 November 1994
Resolved 9 November 1994
Documentation
Issued 5 October 1994 Resolved
SHOW COMPLIANCE WITH REFUSE RECORDKEEPING LOG REQUIREMENTS, IN ACCORDANCE WITH FEDERAL REGISTER VOL.59 NO.75.
Condition: Unknown
Due 3 November 1994
Resolved 9 November 1994
Engineering
Issued 5 October 1994 Resolved
REPAIR OR REPLACE AS PER ORIGINAL, 2 FLAME SCREENS, IN ACCORDANCE WITH 46 CFR 182.20-135.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Lifesaving
Issued 5 October 1994 Resolved
REPAIR OR REPLACE AS PER ORIGINAL, ONE RING LIFE BUOY, IN ACCORDANCE WITH 46 CFR 180.30-5.
Condition: Unknown
Due 3 November 1994
Resolved 9 November 1994
Engineering
Issued 5 October 1994 Resolved
REPAIR OR REPLACE AS PER ORIGINAL, TURBO CHARGER AIR FILTER ON THE PORT MAIN DIESEL ENGINE, IN ACCORDANCE WITH 46 CFR 176.30-1.
Condition: Unknown
Due 3 November 1994
Resolved 9 November 1994
Electrical
Issued 3 November 1993 Resolved
PROVIDE COVERS FOR THE ELECTRICAL OUTLETS LOCATED FORWARD ON THE PORT SIDE.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Engineering
Issued 3 November 1993 Resolved
RELABLE FUEL SHUTOFF VALVES TO INDICATE PROPER OPERATING INSTRUCTIONS.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Electrical
Issued 3 November 1993 Resolved
MAKE OPERATIONAL THE LIGHTING SYSTEM IN THE HEAD SPACE, OR PROVIDE AN ALTERNATE SOURCE OF LIGHTING.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Electrical
Issued 3 November 1993 Resolved
REFURBISH ENGINE SPACE ELECTRICAL WIRING TO SECURE DANGLING WIRES, LOOSE SWITCHES, AND LOOSE JUNCTION BOARD.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Construction/Loadline
Issued 22 October 1991 Resolved
REMOVE TEMPORARY SAND BALLAST AND REPLACE WITH PERMANENT SOLID BALLAST IN THE SAME LOCATION OR PROVE VESSEL CAN OPERATE WITH ACCEPTABLE STABILITY WITHOUT THE BALLAST
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Accommodation/Occupational Safety
Issued 22 October 1991 Resolved
UPGRADE MSD SYSTEM BY INSTALLING A RECIRC SYSTEM WITH SUFFICIENT CAPACITY FOR A FULL DAYS USE.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Documentation
Issued 22 October 1991 Resolved
PROVIDE HYDROSTATIC TABLES (OR CURVES OF FORM) AND COMPLETE DEADWEIGHT SURVEY REPORT WHICH PROVES ESTIMATE OF VESSEL WEIGHT AND VERTICAL CENTER OFGRAVITY FOR STABILITY CALCULATIONS IS VALID.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991

Casualty record · 1

9 August 2023Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7789788
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.