KARAR is a 1991 offshore supply vessel. The Coast Guard has recorded 55 inspections since 1991, most recently in November 2015, along with 74 deficiencies and 2 casualty investigations between 2007 and 2014.

Records from 1991 to 2015. Most recent: inspection, 12 November 2015.

Built
1991
Last inspected
12 November 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9009322 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7881
363465
Flag
UNITED STATES
338505000, 368164000 (licence lapsed)
Maury page id
psix-363465

Inspections, by type

…with no type recorded12
Years with a record 21 calendar years (1991–2015)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it331 - Convention (Subpart B), Net Ton
326 - Regulatory (Subpart C or D), Net Ton
1105 - Convention (Subpart B), Gross Ton
480 - Regulatory (Subpart C or D), Gross Ton
952 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7881MMSI 368164000 · cancelled · compulsorily equipped · granted 18 March 2014, cancelled 11 August 2017
WCW4734MMSI 338505000 · expired · compulsorily equipped · granted 16 September 1998, cancelled 1 July 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEABULK WASHINGTON Offshore Supply Vessel · MISLE 50414 · 4 August 1998 · activity 127266

Inspection history · 55

12 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762521
5 March 2014 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4811152
29 November 2010 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3898369
5 November 2010 MARPOL Annex I Examination · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3884877
14 January 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3663641
1 January 2009 Deficiency Check · Periodic Inspection
Physical examination · Activities Europe · Activity 3403532
12 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3361704
25 October 2008 Hull Examination
Physical examination · Activities Europe · Activity 3351192
3 February 2008 Periodic Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 3138144
21 February 2007 Type not recorded
No type recorded · Activities Europe · Activity 3152931
5 February 2007 Annual Inspection
Physical examination · Activities Europe · Activity 2835778
3 January 2006 Hull Examination · Cargo Tank Internal
Physical examination · Activities Europe · Activity 2538862
4 November 2005 COI Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Activities Europe · Activity 2503502
28 February 2005 Type not recorded
No type recorded · Activities Europe · Activity 2300383
15 February 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2292671
11 January 2005 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 2245748
13 May 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2057912
5 March 2004 Drydock Extension · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Activities Europe · Activity 1896481
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971456
5 May 2003 Type not recorded
No type recorded · Activities Europe · Activity 1902270
7 January 2003 Annual Inspection
Physical examination · Activities Europe · Activity 1680412
5 March 2002 Annual Inspection
Physical examination · Activities Europe · Activity 1483517
10 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 113824
20 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822228
11 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821576
19 July 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820415
13 December 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767038
28 November 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 194960
21 May 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410104
5 October 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472139
4 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 127266
20 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791581
29 April 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125429
24 April 1998 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1123764
17 March 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 175605
3 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119710
31 May 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1107334
25 February 1997 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1099258
15 July 1996 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454350
1 March 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885778
1 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 759434
29 January 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 199484
31 May 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463904
29 November 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177195
26 May 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854225
19 May 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428339
13 May 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353571
22 June 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377000
4 January 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834042
15 September 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389582
8 May 1992 Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260563
25 March 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252953
23 March 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944263
21 August 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353257
11 July 1991 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936904

Deficiency record · 74

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 January 2010 Resolved
Replace/ repair smoke detectors throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2010
Resolution: All smoke detectors functioned as intended.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 January 2010 Resolved
Provide/ Place up to date fire and safety plan fo rthe usSCG approval andplace throughout vessel.
Action required: 705 - Other - as specified
Due 14 March 2010
Resolved 31 December 2011
Resolution: Approved Fire Safety plan posted throughout vessel
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 1 January 2009 Resolved
Proved proof of the annual audit of the SOPEP has been conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2009
Resolved 26 January 2009
Resolution: Received emaill from master advising aduit conducted.
Lifesaving › Launching Appliances › Falls
Issued 1 January 2009 Resolved
Proved proof of the Rescue boat fall being weighted tested
Condition: Improper/Lack of Maintenance
Due 22 February 2009
Resolved 26 January 2009
Resolution: Received email from master advising the Rescue boat fall has been weighted tested
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 October 2008 Resolved
Port and starboard shafts are to be removed during the next hull inspection required by 11/21/2010. The shafts were removed and damage identified. An agreement was made with the class society to allow the vessel to reinstall the shafts and repair them during the next Hull inspection. The bearing tolerances were all sat.
Condition: Damaged By Earlier Event
Due 21 November 2010
Resolved 9 December 2010
Resolution: Shafts were removed, machined in Morgan City and inspected by ABS Class surveyor IAW class rules.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 3 February 2008 Resolved
Install a self closing device on the Engine room door as required for the Fixed Halon system.
Condition: Improper Installation
Due 29 February 2008
Resolved 24 March 2008
Resolution: Received pictures of installed device.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 3 February 2008 Resolved
Provide two Halon cylinders that have been properly tested and Installed.
Condition: Improper/Lack of Maintenance
Due 10 April 2008
Resolved 12 May 2008
Resolution: Cylinders received and placed in service.
Lifesaving › Lifebuoys › Stowage
Issued 5 February 2007 Resolved
Liferings on the aft main deck were found tied to the bracket. Chief officer says they have to tie them down out at sea to prevent them from washing overboard. Install ring buoys or modify brackets in such a manner that they do not need to be tied in place. Extended until next annual based on e-mail from the vessel.
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 3 February 2008
Lifesaving › Lifebuoys › Stowage
Issued 5 February 2007 Resolved
Lifebuoy on the Texas deck, stbd side, is not mounted on a permanent bracket. Vessel has tied the buoy to the rail with line. Install permanent bracket to properly secure the lifebuoy. Extended until next annual based on e-mail from the company.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 3 February 2008
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 5 February 2007 Resolved
Flame screens: properly install flame screens on port side vents for mud tank #3 and ballast tank #6. Extended until next annual based on e-mail from the company.
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 3 February 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 5 February 2007 Resolved
Halon system hydrostatic testing. Provide proof of 5 year external inspection and 12 hydro for flex loop piping in the halon system. Received copy of inspection from 16OCT06. Vessel still needs to hydro flex hose. Extended until 4/7/07.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 14 February 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 February 2007 Resolved
New portable fire extinguishers (type ABC size 2) are too small for the brackets currently onboard. Vessel is to install proper brackets. Items are on order. Extended until 4/7/07.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 3 February 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 February 2007 Resolved
Catwalk to forward Texas Deck (above the Haliburton equipment): Permanently install catwalk ( or remove and install fixed ladder somewhere else). New catwalk is being fabricated in Luanda and waiting shipment. Extended until 4/7/07.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 3 February 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 February 2007 Resolved
Haliburton Engines: Install fuel oil cutoffs in fuel oil lines running from day tanks to Haliburton engines on main deck. 2/26/07: Rcvd e-mail from [name withheld] that Haliburton has reinstalled the fuel cut off valves. Verify at next inspection.
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 3 February 2008
Electrical › Electric Generation Source (service) › Conductor
Issued 5 February 2007 Resolved
Packaged generator power cables: Temp power cable from the package generator is laying on deck on top of the fuel line. Ensure cables remain well clear of fuel line.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 12 February 2007
Resolution: Received e-mail from the vessel that the power lines have been relocated.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 5 February 2007 Resolved
Rescue boat inflation chamber is deflated through leak in one of the seams. Repair the leak iaw manufacturer guidelines. 2/26/07: Rcvd e-mail from [name withheld]. Rescue boat has been repaired at Soyo onboard Johanisturm. Verify at next inspection.
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 3 February 2008
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 5 February 2007 Resolved
Hydro test and inspection of air receivers (due MAR07) could not be tested because vessel did not have strong enough pump and because receivers were installed upside down making it difficult to fix the tanks with water. Vessel is to conduct hydro test in presence of CG inspector at next annual exam.
Action required: 705 - Other - as specified
Due 7 November 2007
Resolved 14 February 2008
Resolution: Test not required by regulation.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Due 19 November 2006
Resolved 30 December 2008
Resolution: VRP #04131 deactivated per correspondence dated 12/19/08
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006 Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization for the LA/Long Beach Captain of the Port zone
Due 19 November 2006
Resolved 30 December 2008
Resolution: VRP #04131 deactivated per correspondence dated 12/19/08
Documentation › Certificates/Documents › Stability Letter
Issued 4 November 2005 Resolved
A new Stability letter is to be onboard to reflex the approved October 2004 Trim & Stability Book.
Condition: Unknown
Due 6 January 2006
Resolved 8 November 2005
Resolution: Received copy of Stability letter as an e-mail attachement. copy placed in Vessel documents.
Lifesaving › Launching Appliances › Falls
Issued 4 November 2005 Resolved
The Rescue boat falls are to be replace and weight test to 1.1 MWL. Report cleared via E-mail dated 22 Nov , Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 24 February 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 November 2005 Resolved
Prove proper operation of the Port Fuel oil day tank reach rod to the fuel shut off valve. Report cleared via E-mail dated 22 Nov, Item remains open until cleared by attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 24 February 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 November 2005 Resolved
Install lagging on both SSGs exposed area of the lower elbow part of the exhaust piping. Report cleared via E-mail dated 22 Nov, Item remains open until cleared by attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 24 February 2006
Engineering › Fuel Oil Service System › Gauge
Issued 4 November 2005 Resolved
Prove proper operation of both SSGs low lube oil alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 24 February 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 11 January 2005 Resolved
Fully manned engine room until proper operation of the engineering automation systems is proven satisfactory by the cognizant OCMI. Received statement from the master attesting completion of the repair and satisfactory operational test. Extended due date until next annual inspection, see activity number 2292671.
Action required: 705 - Other - as specified
Due 13 December 2005
Resolved 7 November 2005
Resolution: Sighted and tested ATP. Issued one def for installing a way to test the Low lube oil alarm on the SSGs.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 January 2005 Resolved
Prove proper operation of the Oily Water Separator to the cognizant OCMI prior to putting the system back into service. Received statement from master attesting completion of repair and satisfactory operational test. Extended due date until next annual inspection, see activity number 2292671.
Due 13 December 2005
Resolved 7 November 2005
Resolution: Confirmed proper operations of the OWS.
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 January 2005 Resolved
Make stbd remote fuel shutdown valve of the engine room readily accessible.
Due 11 March 2005
Resolved 15 February 2005
Resolution: Received e-mail from the company with attached picture and statement from vessel master attesting to the completion.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 January 2005 Resolved
Make repairs to the port side main diesel engine exhaust, leaking.
Due 25 March 2005
Resolved 5 April 2005
Resolution: Received e-mail request to clear last remaining 835 from [name withheld] with attached statement from the master, attesting to the compliance.
Stability › Watertight Integrity › General
Issued 5 March 2004 Resolved
Replace unicellular foam with proper rubber gaskets for all water tight door (WTD) and hatches (particular areas of concern; main deck; aft WTD to accommodation spaces, port storage locker, & starboard rope locker, bridge deck; port and starboard bridge wing WTD)
Due 5 April 2004
Resolved 20 May 2004
Resolution: Corrected. T.G.[name withheld], LT
Stability › Watertight Integrity › General
Issued 5 March 2004 Resolved
Chalk test main deck port side engine room water tight door.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Corrected. T. G. [name withheld], LT
Stability › Watertight Integrity › General
Issued 5 March 2004 Resolved
Seal all electrical wire penetrations (particular areas of concern; forward engine room bulkhead above water tight door)
Due 5 April 2004
Resolved 20 May 2004
Resolution: Corrected. T.G. [name withheld], LT
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2004 Resolved
Remove plastic wire ties and provide metal wire clamps (particular areas of concern; engine room starboard ship service generator)
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 5 March 2004 Resolved
Provide certificates for new (17) shots of chain for port and starboard anchors.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Corrected. T.G. [name withheld], LT
Stability › Watertight Integrity › General
Issued 5 March 2004 Resolved
Replace or gauge wastage found in starboard side hauspipe top .25 meters.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Stability › Incline Test › General
Issued 5 March 2004 Resolved
Provide light ship adjustment and if necessary update stability plan due to modification to number 5 ballast tank to cargo tank modification (as per Tidewater ltr to USCG MSC dated 13FEB04 from [name withheld])
Due 5 April 2004
Resolved 20 May 2004
Resolution: Provided. T.G. [name withheld], LT
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 5 March 2004 Resolved
Provide hydrostatic test with operational pressure (100 psi) to all newly installed cargo piping upon completion of modifications.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Construction/Loadline › Penetrations › Weld
Issued 5 March 2004 Resolved
Provide proof of water tight test (pressure test, dye penetrate, soap test, etc.) to all water tight bulk heads, side shell, bottom plate and main deck penetrations
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 5 March 2004 Resolved
Submit for approval fire and safety plan to include proper location of heat detectors, smoke detectors, portable extinguishers, muster station, emergency lighting, etc.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Provided. T.G. [name withheld], LT
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 5 March 2004 Resolved
Provide original international tonnage certificate onboard
Due 5 April 2004
Resolved 20 May 2004
Resolution: Provided. T. G. [name withheld], LT
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 March 2004 Resolved
Provide hydrostatic testing at DOT approved facility for all portable extinguishers.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Provided. T.G. [name withheld], LT
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2004 Resolved
Replace all expired medication in all first aid kits (particular areas of concern; bridge aspirin, iodine, burn cream and eye dressing)
Due 5 April 2004
Resolved 20 May 2004
Resolution: Corrected. T.G. [name withheld], LT
Communications › Radio Communications › Emergency Source of Power
Issued 5 March 2004 Resolved
Replace inoperative emergency battery for VHF, SSB and general alarm.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Replaced. T.G. [name withheld], LT
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 5 March 2004 Resolved
Remount, replace or remove actuator valves in tunnel space (particular areas of concern; valves located at frame 52 and 64)
Due 5 April 2004
Resolved 20 May 2004
Resolution: Replaced. T.G. [name withheld], LT
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2004 Resolved
Remove dead end electrical cable at frame 57
Due 5 April 2004
Resolved 20 May 2004
Resolution: Removed. T.G. [name withheld], LT
Construction/Loadline › Penetrations › Weld
Issued 5 March 2004 Resolved
Weld aft side of forward steering gear sump suction pipe penetration on centerline aft engine room bulkhead under deck plates.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Repairs completed. T.G. [name withheld], LT
Engineering › Bilge Water Management System › Pump
Issued 5 March 2004 Resolved
Replace inoperative steering gear sump pump
Due 5 April 2004
Resolved 20 May 2004
Resolution: Replaced. T.G. [name withheld], LT
Engineering › Bilge Water Management System › Piping
Issued 5 March 2004 Resolved
Repair cracked steering gear sump piping forward of aft engine room bulkhead
Due 5 April 2004
Resolved 20 May 2004
Resolution: Repairs completed. T.G. [name withheld], LT
Communications › Alarms/Indicators › General Alarm
Issued 5 March 2004 Resolved
Repair inoperative general alarm light located in forward port engine room corner LEGACY COMPONENT DESC: General Alarm
Due 5 April 2004
Resolved 5 April 2004
Resolution: New general alarm light (red flashing light) installed. Installation verified by picture sent from master. T.G. [name withheld], LT
Communications › Alarms/Indicators › General Alarm
Issued 5 March 2004 Resolved
Provide adequate sound level for general alarm in tunnel (adjacent to bow thruster), operating engine room, and steering gear room. LEGACY COMPONENT DESC: General Alarm
Due 5 April 2004
Resolved 5 April 2004
Resolution: Installed new red flashing light. Installation verified by picture sent from master. T.G. [name withheld], LT
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 5 March 2004 Resolved
Prove lube oil shutdown/alarms for all propulsion and generator engines. A pump for this test should be provided per vessel's approved automation procedures.
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed, T.G. [name withheld], LT
Engineering › Steering Gear System › Linkage
Issued 5 March 2004 Resolved
Provide locking nuts for all rudder angle indicator linkages
Due 5 April 2004
Resolved 21 April 2004
Resolution: Completed. T.G. [name withheld], LT
Engineering › Fuel Oil Service System › Valve, Control
Issued 5 March 2004 Resolved
Label emergency shut down switches located outside port engine room escape hatch
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 March 2004 Resolved
Prove proper operation for vessel's oily water separator
Due 5 April 2004
Resolved 20 May 2004
Resolution: Completed. T.G. [name withheld], LT
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 5 March 2004 Resolved
Provide proper size branch circuit breaker for 30 hp motor branch circuit as indicated in USCG MSC letter 16710/P010038/mse note 1 (attached to activity 1896481). LEGACY COMPONENT DESC: Circuit Breaker
Due 30 April 2004
Resolved 20 May 2004
Resolution: Provided. T.G. [name withheld], LT
Deck/Cargo › Cargo Stowage › General
Issued 5 March 2004 Resolved
Provide a means of sounding cargo tank number 5 in accordance with 46CFR56.50-90(a) as indicated in USCG MSC letter 16710/P010038/mse note 2 (attached to activity 1896481).
Due 30 April 2004
Resolved 20 May 2004
Resolution: Provided. T.G. [name withheld], LT
Pollution Prevention/Response › Prevention Equipment
Issued 7 January 2003 Resolved
Ensure Oily water Separator oil content meter and alarm are operational. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached statement that the test procedures are available for the OWS and the visual and audible alarms have been added to the system.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 January 2003 Resolved
Ensure all portable fire extinguishers are within the hydrostatic test dates LEGACY COMPONENT DESC: Service
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached certificate stating all CO2 were hydrostatically tested.
Lifesaving › Rescue Boat
Issued 7 January 2003 Resolved
Ensure rescue boat meets the MIO Europe's policy letter. Rescue boat must be rigid hull. LEGACY COMPONENT DESC: Hull (rigid)
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached statement that a new rescue boat is at Malongo, Angola and will be delivered to the vessel.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 January 2003 Resolved
Ensure port and starboard turbo chargers on the main diesel engines are properly insulated. LEGACY COMPONENT DESC: Turbocharger
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached statement that formed turbo covers have been ordered, awaiting delivery.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 7 January 2003 Resolved
Ensure auxiliary generators have a proper oil drain to the bilges.
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with an attached photograph showing a drain line.
Electrical › Lighting (emergency)
Issued 7 January 2003 Resolved
Provide emergency lighting in way of port and starboard engine room emergency escape hatches.
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached photographs showing intalled emergency lighting.
Operations/Management › Drills/Instruction
Issued 7 January 2003 Resolved
Ensure the vessel crew receives training required by 49 CFR 172.700
Due 8 March 2003
Resolved 6 March 2003
Resolution: Received email from the master with attached instruction from Tidewater Marine Safe Operations System Manual. This instruction is for the purpose of meeting the Hazardous Communications standards.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 March 2002 Resolved
Complete annual servicing.
Due 29 March 2002
Resolved 8 January 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 5 March 2002 Resolved
Replace fire extinguisher in galley with Coast Guard approved fire extinguisher.
Due 29 March 2002
Resolved 25 March 2002
Lifesaving › Embarkation Appliances/Stations
Issued 5 March 2002 Resolved
Provide second embarkation ladder.
Condition: Unknown
Due 29 March 2002
Resolved 8 January 2003
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 5 March 2002 Resolved
Replace flame screen for vent for stbd side fuel tank.
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 25 March 2002
Deck/Cargo
Issued 22 June 1993 Resolved
Make dry bulk tanks available for internal inspection not later than next drydock inspection.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 11 July 1991 Resolved
PROVIDE APPROVAL OF BOTH PRESSURE VESSELS MADE BY MANCHESTER TANK, SERIALS_x001C_#101768 AND 101770 AS REQUIRED BY 46 CFR 54.01-5 (d) AND CORROSION ALLOWANCE AS REQUIRED BY 46 CFR 54.01-35.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Accommodation/Occupational Safety
Issued 11 July 1991 Resolved
PROVIDE APPROVAL FOR INSTALLED TOASTMASTER RANGE AS REQUIRED BY 46 CFR _x001C_ 111.77-3 (a)
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Engineering
Issued 11 July 1991 Resolved
PROVIDE APPROVED PLANS FOR AUTOMATED CONTROL SYSTEM AS REQUIRED BY 46 CFR 91.55-5.
Condition: Unknown
Due 26 August 1991
Resolved 25 November 1991
Fire Fighting
Issued 11 July 1991 Resolved
PROVIDE APPROVED PLANS FOR FIRE DETECTION SYSTEM AS REQUIRED BY 46 CFR 91.20-15.
Condition: Unknown
Due 26 August 1991
Resolved 25 November 1991
Documentation
Issued 11 July 1991 Resolved
PROVIDE CERTIFICATE OF ALTERNATE COMPLIANCE ONBOARD VESSEL AS REQUIRED TO COMPLY WITH ANNEX I, 3 (a) OF USCG NAVIGATION RULES.
Condition: Unknown
Due 11 August 1991
Resolved 25 November 1991
Documentation
Issued 11 July 1991 Resolved
PROVIDE ONBOARD AN FCC RADIOTELEPHONE CERTIFICATE (CARGO SHIP) AS REQUIRED BY 46 CFR 91.60-20.
Condition: Unknown
Due 11 August 1991
Resolved 25 November 1991
Documentation
Issued 11 July 1991 Resolved
PROVIDE O.C.M.I. A COPY OF SHIPS LOG INDICATING SATISFACTORY DRILLS HAVING BEEN CONDUCTED AS REQUIRED BY 46 CFR 97.35-5 (a)
Condition: Unknown
Due 11 August 1991
Resolved 25 November 1991

Casualty record · 2

21 February 2007Routine · role: Involved in a Marine Casualty · activity 3152931
5 March 2014Routine · role: Suspected Pollution Source · activity 4811152
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

WAR ADMIRAL (2007–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.