MAURY USCG vessel records Sign in
← All vessels

SILVER LAKES

SILVER LAKES is a 1986 freight ship. The Coast Guard has recorded 34 inspections since 1991, most recently in July 2009, along with 54 deficiencies and 8 operational controls.

Records from 1991 to 2009. Most recent: inspection, 24 July 2009.

Built
1986
Last inspected
24 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8503072 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
363506
Flag
BELIZE
—
Maury page id
psix-363506

Inspections, by type

…with no type recorded28
Years with a record 13 calendar years (1991–2009)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12351 - Convention (Subpart B), Net Ton
17835 - Convention (Subpart B), Gross Ton
32329 - Displacement, Ton
23929 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

24 July 2009 COE-Offshore
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3544788
18 November 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3365268
17 November 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3364790
10 February 2003 Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1742754
9 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1742126
9 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1742351
6 January 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1726599
2 December 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1714308
2 December 2002 Damage Survey · Passenger/Freight Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1723327
26 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1734610
11 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1697582
9 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1687684
7 October 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1686013
13 November 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295477
7 November 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 641364
30 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293402
29 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101324
28 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287551
2 June 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 278435
13 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 723284
23 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 432004
16 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431738
9 August 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 155910
7 October 1998 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 422501
30 September 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 420858
17 September 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 420656
8 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 403394
7 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 394109
24 May 1996 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 391558
15 September 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 382492
3 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 378856
12 October 1993 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 361521
5 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357361
28 May 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 344060

Deficiency record · 54

Personnel › Certificates/Documents/Licenses
Issued 10 February 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 13 February 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Lubricating Oil Service System
Issued 10 February 2003 Resolved
The NO.1 generator has a temporary patch on the inlet side of the cooling water piping to the lube oil cooler. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 13 February 2003
Resolution: Inspected new repairs to piping. All satisfactory.
Engineering › Diesel Engine (propulsion-electric)
Issued 10 February 2003 Resolved
The main engine has a spraying leak on the rear of the NO.7 cylinder head piping at the fitting/head. LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 13 February 2003
Resolution: Inspected repairs to fitting, all satisfactory.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 February 2003 Resolved
The main engine has oil leaks on the aft turbocharger, at the flanges. LEGACY COMPONENT DESC: Turbocharger
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 13 February 2003
Resolution: Inspected repairs to turbocharger, all satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 10 February 2003 Resolved
The bunker fill piping has a rubber hose connecting it to the distribution manifold. Class to attest to the arrangement of the piping prior to any bunker transfer. LEGACY COMPONENT DESC: Cargo Manifold
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 13 February 2003
Resolution: Inspected manifold, hose has been removed and blank flanged.
Accommodation/Occupational Safety › Potable Water System
Issued 17 December 2002 Resolved
Prove proper operation of auxiliary heating boiler which provides hot water for the crew IAW ILO 147.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2003
Resolution: Observed satisfactory operation of hot water heating boiler.
Fire Fighting › Fire Pumps
Issued 17 December 2002 Resolved
Repair seal leaks in No. 2 firepump and "harbor" pump IAW SOLAS 74 (ammended) Chapter II-2, Regulation 4.3.3.4. LEGACY COMPONENT DESC: Pumpshaft
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2003
Resolution: Observed satifactory operational test.
Construction/Loadline › Markings
Issued 17 December 2002 Resolved
The load line and draft marks are not painted in a contrasting color IAW ICLL Annex I, Chapter 1 Regulation 8. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2003
Resolution: Observed markings painted in a contrasting color.
Personnel › Training › Fire Fighting Basic
Issued 5 December 2002 Resolved
Ship's officers and crew incompetent to carry out fire drill duties.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2002
Lifesaving › Launching Appliances › Winch
Issued 5 December 2002 Resolved
Starboard life boat winch not in working order.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2002
Lifesaving › Launching Appliances › Davit
Issued 5 December 2002 Resolved
Life boats unable to gravity launch. Discrepancy not reported to owner.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Fire Fighting › Miscellaneous Items
Issued 5 December 2002 Resolved
Fire alarm at entrance to emergency generator room was inoperative.
Action required: 705 - Other - as specified
Resolved 5 December 2002
Fire Fighting › Miscellaneous Items
Issued 5 December 2002 Resolved
Ship's communication system equipment inoperative.
Action required: 705 - Other - as specified
Resolved 14 December 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 5 December 2002 Resolved
#1 SSDG has a water leak to the lube oil cooler.
Action required: 705 - Other - as specified
Resolved 14 December 2002
Engineering › Freshwater Generation System
Issued 5 December 2002 Resolved
Evaporator producing fresh water is inoperative.
Action required: 705 - Other - as specified
Resolved 14 December 2002
Resolution: Repair verified in conjunction with ISM Audit.
Operations/Management › Equipment Service/Testing
Issued 3 December 2002 Resolved
Inspection of the vessel reveals substantial discrepancies in routine maintenance and upkeep. Complete a satisfactory audit of the Safety Management System with an approved recognized organization.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2002
Resolution: ISM audit completed, see narrative for details.
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 3 December 2002 Resolved
The vessel does not maintain a log of casualty maintenance notification to ship owner or results of repairs. Vessel reps could not provide proof of notification for damaged generators. Complete an ISM Audit in presence of USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2002
Resolution: ISM audit completed, see narrative for details.
Navigation
Issued 30 August 2001 Resolved
Rudder post filled with cement and has metal plates with cracked welds. Provide Class report approving this arrangement prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
The #1 generator has major fuel oil leaks on the #4 and #6 injectors on cylinder heads. Repair to the satisfaction of Class prior to the operation of engine in U.S. waters.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
Numerous minor leaks found on all generators. Repair all fuel oil leaks prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
Oil was found in oily water separator dicharge line after the sampling point for 15ppm monitor and at flange at overboard valve. Provide Class report proving proper operation of oily water separator and monitor prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
The #2 start air compressor is not operational. Provide Class report approving this arrangement prior to departure. Class issued COC to repair compressor by 30SEP01.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Engineering
Issued 30 August 2001 Resolved
Automatic 3 way valve for oily water separator 15ppm did not work for 7 times. Valve did not fully move because of excessive water in control air lines. Provide Class report proving proper operation prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
The #1 generator has excessive F/O leaks on #5 injector at cylinderhead andon #3 F/O injection pump High pressure outlet pipe. Repair leaks to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Navigation
Issued 30 August 2001 Resolved
Excessive oil leaking from both #1 and #2 steering pump mechanical seals. Repair to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Lifesaving
Issued 30 August 2001 Resolved
Excessive fuel and oil found on all generators, oil tank containment areas,and engine room decks. Thoroughly clean all generators and engine room of all standing fuel and oil by next U.S port.
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Engineering
Issued 30 August 2001 Resolved
The #3 generator has fuel misting from F/O injection pumps #1,2,4,and #5. Repair all leaks to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Engineering
Issued 30 August 2001 Resolved
The #3 generator has excessive F/O leaks on the F/O supply duplex filters. Repair to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Accommodation/Occupational Safety
Issued 30 August 2001 Resolved
Sewage overboard valves found open and treatment plant was secured. Secure and lock all valves immediately.
Condition: Unknown
Due 30 August 2001
Resolved 3 September 2001
Accommodation/Occupational Safety
Issued 30 August 2001 Resolved
Marine sanitation device treatment tank is holed , wasted and leaking at several places. Repair all wasted sections.
Condition: Unknown
Due 5 September 2001
Resolved 10 September 2001
Lifesaving
Issued 30 August 2001 Resolved
Oil found in port pipe tunnel and water found in starboard pipe tunnel. Remove all oil and water to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Fire Fighting
Issued 30 August 2001 Resolved
One breathing apparatus mask lens is cracked. Repair or replace to the satisfaction of Class prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Navigation
Issued 30 August 2001 Resolved
Excessive oil found in steering compartment and on steering machinery. Remove all oil prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Lifesaving
Issued 30 August 2001 Resolved
Purifier room has excessive fuel oil in bilges and on piping. Clean and remove all fuel oil prior to departure.
Condition: Unknown
Due 30 August 2001
Resolved 10 September 2001
Lifesaving
Issued 28 February 2001 Resolved
Repair or replace hydrostatic release on port and stbd liferafts. The current arrangement will not work. SOLAS 74 III/15. Correct prior to departure.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Navigation
Issued 28 February 2001 Resolved
Repair inoperable gyrocompass prior to departure. 33 CFR 164.35.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Documentation
Issued 2 June 2000 Resolved
Update various manuals and signs from German language to the language of the crew. To be corrected prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Fire Fighting
Issued 2 June 2000 Resolved
Upgrade instructions to CO2 manifold where actuation is not clear. solas 74 I/11. To be corrected prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Documentation
Issued 2 June 2000 Resolved
Upgrade oil transfer procedure. 33 CFR 155.750. To be correct prior to any petroleum transfers.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Engineering
Issued 2 June 2000 Resolved
Provide mechanical means to close drains to discharge containment. 33 CFR 156.120. To be corrected prior to any petroleum transfers.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Documentation
Issued 2 June 2000 Resolved
Provide last and next dry dock dates. To be corrected prior to departure.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Construction/Loadline
Issued 23 August 1999 Resolved
DRAFT AND PLIMSOL MARK TO BE PAINTED PRIOR TO NEXT US PORT.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Navigation
Issued 7 October 1998 Resolved
VSL HAS A 8 DEGREE ERROR IN IT'S GYRO COMPASS. A TEMPORARY_x001C_ GYROCOMPASS WAS INSTALLED ON BOARD AND A LETTER OF DEVIATION WAS GRANTED.
Condition: Unknown
Due 10 October 1998
Resolved 10 November 1998
Navigation
Issued 7 October 1998 Resolved
VSL FAILED TO HAVE REQUIRED MARINE CHARTS ON BOARD.
Condition: Unknown
Due 7 October 1998
Resolved 12 November 1998
Engineering
Issued 24 May 1996 Resolved
VESSEL DID NOT HAVE MECHANICAL CLOSURE DEVICES FOR DISCHARGE CONTAINMENT AROUND FUEL VENTS AND HEADERS. VESSEL CREW WAS USING WOOD PLUGS TO PLUG DRAINS IN CONTAINMENT.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Lifesaving
Issued 3 June 1995 Resolved
Provide a smoke float & light arrangement for the ring buoys on the bridge wings. Current ones expired in 31APR95. Provide at next U. S. port call per SOLAS Chpt III Reg 7 (1.3).
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Navigation
Issued 3 June 1995 Resolved
Existing copy of Western United States Coast Pilot was published in 1975. At next U.S. port call, provide up to date Coast Pilot for applicable geographic area.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Lifesaving
Issued 3 June 1995 Resolved
Provide three lifeboat (GMDSS) radios on the vessel prior to return to a U.S. port per SOLAS Chpt III Reg 6 (2.1.1).
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Engineering
Issued 3 June 1995 Resolved
Make permanent repairs to the wasted engineroom piping prior to return to U.S. per SOLAS Chpt II-1 Reg 26(1). Reference PSNS for detailed locations.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Lifesaving
Issued 3 June 1995 Resolved
Make a general cleaning of the oil covered areas in the engineroom bilges and the heavy fuel oil heating piping & deck (port side, fwd, lower level) prior to return to a U. S. port per SOLAS Chpt II-2 Reg 2(1).
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Navigation
Issued 28 May 1991 Resolved
CHART # 18521 NOT ON BOARD. (33CFR164.30)
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Navigation
Issued 28 May 1991 Resolved
CHART # 18523 NOT ON BOARD. (33CFR164.30)
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Navigation
Issued 28 May 1991 Resolved
CHART # 18524 NOT ON BOARD. (33CFR164.30)
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Navigation
Issued 28 May 1991 Resolved
INLAND NAVIGATION RULES NOT ON BOARD. (33CFR88.05)
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.