Professional
The full record for this vessel
Behind this panel: 5 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 5
25 May 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6153552
19 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6150076
8 March 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6101118
29 April 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5865471
26 February 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5842334
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 May 2017
Resolved
1400 74SOLAS(2014) I-11(a) 17ac The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship on all respects will remain fit to proceed to sea without danger to the ship or persons on board. Discovered raw water leak in the common discharge pipe for the #1 and #2 engine coolers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2017
Resolution: Sector LA/LB recieved class report attesting to the repair of the cool water piping system.
Engineering › Fuel Oil Service System › Pump
Issued 19 May 2017
Resolved
1420 74SOLAS(2001)II-2/15.2 15ac In which oil fuel is used, the arrangement for the storage, distribution and utilization of the oil fuel shall be as to ensure the safety of the ship and persons on board. Identified fuel oil leaks on the #1 and #2 fuel oil supply pumps.
Action required: 15 - Rectify deficiencies by next port
Due 22 May 2017
Resolved 22 May 2017
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 May 2017
Resolved
1730 MARPOL I/14.1 40ac Any ship of 400 GT and above but less than 10,000 GT shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. The vessel's oily water separator is inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: The defected 10 stranded ribbon cable was replaced and function test(15 ppm alarm and valve
operation) followed which was in order.
Engineering › Lubricating Oil Service System › Piping
Issued 19 May 2017
Resolved
1420 74SOLAS(2001)II-2/15.3 40ac The arrangement for storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. Identified lube oil leaks on the #2 and #3 diesel generators.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Leakage was from the governor for both #2 and #3 diesel generator engine due to the grooving between driveshaft and sealing. The defected driveshaft and oil sealing was replaced and checked while the engine was running. No leakage was observed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 May 2017
Resolved
0750 74SOLAS(2001)II-2/47.1 40ac The resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The class "A-0" door leading from the crew's laundry to the lift service was missing door knob and lock leaving two sizeable through holes in the Class "A" rated door.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: The missing knob and lock was installed/checked and found in order.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 May 2017
Resolved
0750 74SOLAS(2001)II-2/47.1 40ac The resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The self-closing Class "A" door leading into the Galley from the cooridor is not able to fully close.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: The door closure is repaired by Ship's crew and now closing fully.
Construction/Loadline › Markings › Load Line Mark
Issued 19 May 2017
Resolved
1200 ICLL 66, REG 8 40ac The ring, lines and letters shall be painted in white or yellow on dark ground or in black on a light ground. The load line and plimsol marking on the starboard side were the same color as the vessel's hull.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Confirmed that painting of loadline and plimsol marking on the port and staboard was done in white.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 29 April 2016
Resolved
74SOLAS(14) CH I REG 11(B) - 10AC - AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. NUMEROUS SECTIONS OF THE A-CLASS FIRE INSULATION SURROUNDING WIRING WERE MISSING IN MULTIPLE DECKS OF THE PIPING AND DUCK AND ELECTRICAL TRUCK SPACES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: corrected before departure and recieved class approval.