MAURY USCG vessel records
← All vessels

MARINER

Built
1991
Last inspected
15 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9973
363728
Flag
UNITED STATES
Maury page id
psix-363728

Documentation record

Registered dimensions (L × B × D)64.5 ft × 17.5 ft × 9.0 ft
Registered tonnagegross 68 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ & T CUSTOM MARINE, INC · PANAMA CITY, FL, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPROVIDENCE, RI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Simplified, Gross Ton
54 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

15 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8253100
14 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8135066
17 April 2024 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893300
17 January 2024 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7850571
8 January 2024 Simplified Stability Test · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7846651
23 October 2023 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813134
16 August 2023 Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7770444
12 June 2023 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7714628
7 December 2022 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7600701
15 December 2021 Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7352865
9 September 2021 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7308575
31 August 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7288699
13 November 2020 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7094022
11 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6870406
20 August 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6789643
17 January 2019 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6611550
28 November 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6588894
17 April 2018 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6393441
17 April 2018 Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6393672
15 December 2017 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6325034
23 August 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6249699
12 March 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6128417
12 December 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6056555

Deficiency record · 23

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025 Resolved
"Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI... the alcohol testing of each individual must be conducted within 2 hours of when the SMI occured." Vessel had expired alcohol test kits onboard. Replace alcohol test kits. 46 CFR 4.06-3(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: Test kits provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025 Resolved
"A vessel must be provided with bilge pumps in accordance with Table 182.520(a)." Vessel did not have fixed power pump for forepeak space. Provide a bilge pump or a hand pump. 46 CFR 182.520(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
Resolution: video of new electric submersible pump working
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2025 Resolved
"As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts of large enough scale to make safe navigation possible." Vessel did not have a means to confirm date of last chart update. Provide date of last update. 46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 17 June 2025
Resolution: Vessel provided up-to-date charts.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 May 2025 Resolved
"The name of a vessel must be marked or painted in clearly legible letters and numbers: on each life float and buoyant apparatus." Life floats did not have vessel's name marked. Mark vessel's name or remove from service. 46 CFR 185.604(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: LF's labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 May 2025 Resolved
"The name of the vessel must be marked or painted in clearly legible letters on each life float paddle." Vessel's life floats' paddles did not have vessel name marked. Mark vessel's name or remove from service.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: LF paddle's labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025 Resolved
"Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name." One of the vessel's ring life buoys was not marked. Mark with vessel's name. 46 CFR 185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 9 June 2025
Resolution: Marked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 May 2025 Resolved
"The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection..." Vessel's installed EPIRB did not have a float free arrangement. Install float free arrangement or remove unit from service. 46 CFR 177.100
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 9 June 2025
Resolution: Hydrostatic release installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2024 Resolved
PROVIDE REQUIRED DAPI PROGRAM INFORMATION & ALCOHOL TEST PROCEDURES.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2024
Resolution: O/O provided consortium enrollment & records of testing, etc.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 April 2024 Resolved
CORRECT MULTIPLE NAVIGATION RELATED DEFICIENCIES: COMPASS BINACLE LIGHT ANCHOR LIGHT (CORRECTED ON SPOT)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2024 Resolved
SUBMIT ELECTRONIC THROTTLE CONTROL PLANS TO OCMI OFFICE FOR REVIEW (POSSIBLY MSC). PRIOR TO USE (705-c) UPDATE: DIRECTED O/O TO SUBMIT TO MSC DUE NEW INSTALL, WITH [name withheld] FOLLOWING MSC APPROVAL.
Action required: 705 - Other - as specified
Resolved 14 May 2025
Resolution: DVTPs completed on annual inspection. Verified Approval letter on board.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 April 2024 Resolved
ENGINE ROOM OVERHEAD INSULATION, RESTORE. OVERHEAD AND BULK-HEAD PENETRATIONS PROPERLY FIRE-STOPPED (ASTM E 84) [since modified to water / vapor tight) RE-INSPECTED ON 08MAY24 - OPENING / DEFICIENCIES REMAIN
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Accepted submtd evidence of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2024 Resolved
CABIN - AFT BILGE PUMP WIRING, COMPANIONWAY OUTLET / RECEPTACLE IN CABINET. WIRING PULLING-OUT, REPAIR / REPLACE, W/ PRESSURE-CONNECTIONS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: O/O provided acceptable evidence of re-wired circuit - SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 April 2024 Resolved
FIRE MAIN PIPING ELBOW DISCHARGE FROM PTO PUMP - REPAIR / REPLACE (due corrosion, evidence of leak)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2024
Resolution: O/O provided evidence of sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 April 2024 Resolved
CONDUCT UNDERWAY DRILLS (FIRE & MOB) WITH NEW MOB PLATFORM / STAGE IN PRESENCE OF USCG MI's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: CONDUCTED U/W DRILLS INCL . MOPB W/ USE FO NEWLY INSTALLED STAGE / PLATFORM - O/O INTENDS TO ADD SOME SUPPORT WIRES, BUT DRILL & SERVICEABILITY, ALL SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 April 2024 Resolved
POST NO OVERNIGHT ACCOMODATIONS ACCESS TO PASSENGERS. (and amend COI w/ required verbiage)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2024 Resolved
RE-LOCATE PORTABLE FIRE EXTINGUISHERS PER REQUIREMENTS, PROVIDE; 10-B:C TO OPERATING STATION MINIMUM 2-A TO AFT ACCOMODATION SPACE
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2024
Resolution: Accepted evidence of fire ext. re-location.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2021 Resolved
Vessels on coastwise route must have a ring life buoy that is orange in color. The ring life buoy near the wheelhouse has faded and is no longer orange in color. Replace ring life buoy. 46 CFR 180.70 (b)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 23 December 2021
Resolution: new RLB purchased
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2021 Resolved
Excavate extent of wastage to the 4 deck frames on the outboard starboard side of the engine room starting at the aft bulkhead and moving forward. Remove insulation to better see the area, and provide a repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 11 January 2022
Resolution: provided and assessed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2019 Resolved
EPRIB battery is expired and needs replacement. Current battery is still functioning.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 January 2020
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 December 2019 Resolved
Smoke detector in accomdation space is expire past 10 years. Vessel notified to replace.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 January 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 December 2019 Resolved
Aspirin and eye wash solution is expired. Vessel notified to reaplce.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 16 December 2019
Resolution: Provide asiprin and eyewash.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 November 2018 Resolved
Fixed fire fighting controls must be located outside the space protected by the system. The CO2 operated pressure switch for the M/E shutdown is located in the engine room. Pressure switches are considered controls and therefore the pressure switch must be relocated outside the space. Relocation of the switch to be completed by a fire suppression service technician.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 17 January 2019
Resolution: Recieved e-mail photo from vessel rep. showing the pressure switch re-located outside the engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 17 April 2018 Resolved
Vessel must be dry-docked and inspected by a Coast Guard Marine Inspector prior to carrying passengers. This requirement is a result of a collision with a submerged navigation buoy and subsequent survey with a remotely operated underwater vehicle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2018
Resolution: Vessel dry-docked and inspected.

Recorded names · 1

ENVIRO-LAB III (2011–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.