Records from 1990 to 2025. Most recent: inspection, 15 October 2025.
Inspection history · 68
15 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8253100
14 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8135066
17 April 2024
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893300
17 January 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7850571
8 January 2024
Simplified Stability Test · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7846651
23 October 2023
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813134
16 August 2023
Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7770444
12 June 2023
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7714628
7 December 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7600701
15 December 2021
Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7352865
9 September 2021
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7308575
31 August 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7288699
13 November 2020
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7094022
11 December 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6870406
20 August 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6789643
17 January 2019
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6611550
28 November 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6588894
17 April 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6393441
17 April 2018
Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6393672
15 December 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6325034
23 August 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6249699
12 March 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6128417
12 December 2016
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6056555
18 October 2015
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5745055
24 September 2015
Initial Construction-Excluding Oversight · Plan Review (Other than "T")
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5727362
26 August 2015
Examination of Repairs · COI Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5227805
19 September 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4148784
23 August 2011
Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4125023
3 April 2009
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3445655
10 February 2009
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3416192
12 September 2008
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3323266
10 September 2008
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3323184
8 September 2006
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2772834
29 August 2006
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2762737
26 October 2005
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2522767
1 September 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2485355
26 August 2005
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2475453
10 November 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1943656
4 September 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1890854
5 September 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1664262
11 July 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1644764
20 June 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1632040
12 September 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1451755
9 March 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1059719
7 September 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1384544
2 February 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1466653
23 September 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1433533
9 September 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1365355
9 September 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 802601
1 July 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 793481
29 August 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 785035
6 September 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1138358
25 June 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088479
6 September 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875091
29 September 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 90715
13 September 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867570
1 July 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354881
24 March 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1165753
5 October 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1157176
30 June 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846990
16 November 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 176381
24 October 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 94756
12 September 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945833
10 September 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945831
6 April 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1256260
10 October 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1250159
17 September 1991
Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317487
10 October 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 940834
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025
Resolved
"Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the SMI... the alcohol testing of each individual must be conducted within 2 hours of when the SMI occured." Vessel had expired alcohol test kits onboard. Replace alcohol test kits.
46 CFR 4.06-3(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: Test kits provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025
Resolved
"A vessel must be provided with bilge pumps in accordance with Table 182.520(a)." Vessel did not have fixed power pump for forepeak space. Provide a bilge pump or a hand pump.
46 CFR 182.520(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2025
Resolution: video of new electric submersible pump working
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2025
Resolved
"As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts of large enough scale to make safe navigation possible." Vessel did not have a means to confirm date of last chart update. Provide date of last update.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 17 June 2025
Resolution: Vessel provided up-to-date charts.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 May 2025
Resolved
"The name of a vessel must be marked or painted in clearly legible letters and numbers: on each life float and buoyant apparatus." Life floats did not have vessel's name marked. Mark vessel's name or remove from service.
46 CFR 185.604(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: LF's labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 May 2025
Resolved
"The name of the vessel must be marked or painted in clearly legible letters on each life float paddle." Vessel's life floats' paddles did not have vessel name marked. Mark vessel's name or remove from service.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 28 May 2025
Resolution: LF paddle's labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025
Resolved
"Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name." One of the vessel's ring life buoys was not marked. Mark with vessel's name.
46 CFR 185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 9 June 2025
Resolution: Marked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 May 2025
Resolved
"The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection..." Vessel's installed EPIRB did not have a float free arrangement. Install float free arrangement or remove unit from service.
46 CFR 177.100
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 9 June 2025
Resolution: Hydrostatic release installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2024
Resolved
PROVIDE REQUIRED DAPI PROGRAM INFORMATION & ALCOHOL TEST PROCEDURES.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2024
Resolution: O/O provided consortium enrollment & records of testing, etc.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 April 2024
Resolved
CORRECT MULTIPLE NAVIGATION RELATED DEFICIENCIES:
COMPASS BINACLE LIGHT
ANCHOR LIGHT (CORRECTED ON SPOT)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2024
Resolved
SUBMIT ELECTRONIC THROTTLE CONTROL PLANS TO OCMI OFFICE FOR REVIEW (POSSIBLY MSC).
PRIOR TO USE (705-c)
UPDATE: DIRECTED O/O TO SUBMIT TO MSC DUE NEW INSTALL, WITH [name withheld] FOLLOWING MSC APPROVAL.
Action required: 705 - Other - as specified
Resolved 14 May 2025
Resolution: DVTPs completed on annual inspection. Verified Approval letter on board.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 April 2024
Resolved
ENGINE ROOM OVERHEAD INSULATION, RESTORE. OVERHEAD AND BULK-HEAD PENETRATIONS PROPERLY FIRE-STOPPED (ASTM E 84)
[since modified to water / vapor tight)
RE-INSPECTED ON 08MAY24 - OPENING / DEFICIENCIES REMAIN
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Accepted submtd evidence of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2024
Resolved
CABIN - AFT BILGE PUMP WIRING, COMPANIONWAY OUTLET / RECEPTACLE IN CABINET. WIRING PULLING-OUT, REPAIR / REPLACE, W/ PRESSURE-CONNECTIONS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: O/O provided acceptable evidence of re-wired circuit - SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 April 2024
Resolved
FIRE MAIN PIPING ELBOW DISCHARGE FROM PTO PUMP - REPAIR / REPLACE (due corrosion, evidence of leak)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2024
Resolution: O/O provided evidence of sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 April 2024
Resolved
CONDUCT UNDERWAY DRILLS (FIRE & MOB) WITH NEW MOB PLATFORM / STAGE IN PRESENCE OF USCG MI's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: CONDUCTED U/W DRILLS INCL . MOPB W/ USE FO NEWLY INSTALLED STAGE / PLATFORM - O/O INTENDS TO ADD SOME SUPPORT WIRES, BUT DRILL & SERVICEABILITY, ALL SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 April 2024
Resolved
POST NO OVERNIGHT ACCOMODATIONS ACCESS TO PASSENGERS.
(and amend COI w/ required verbiage)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2024
Resolved
RE-LOCATE PORTABLE FIRE EXTINGUISHERS PER REQUIREMENTS, PROVIDE;
10-B:C TO OPERATING STATION
MINIMUM 2-A TO AFT ACCOMODATION SPACE
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2024
Resolution: Accepted evidence of fire ext. re-location.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2021
Resolved
Vessels on coastwise route must have a ring life buoy that is orange in color. The ring life buoy near the wheelhouse has faded and is no longer orange in color. Replace ring life buoy. 46 CFR 180.70 (b)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 23 December 2021
Resolution: new RLB purchased
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2021
Resolved
Excavate extent of wastage to the 4 deck frames on the outboard starboard side of the engine room starting at the aft bulkhead and moving forward. Remove insulation to better see the area, and provide a repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 11 January 2022
Resolution: provided and assessed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2019
Resolved
EPRIB battery is expired and needs replacement. Current battery is still functioning.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 January 2020
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 December 2019
Resolved
Smoke detector in accomdation space is expire past 10 years. Vessel notified to replace.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 January 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 December 2019
Resolved
Aspirin and eye wash solution is expired. Vessel notified to reaplce.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 16 December 2019
Resolution: Provide asiprin and eyewash.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 November 2018
Resolved
Fixed fire fighting controls must be located outside the space protected by the system. The CO2 operated pressure switch for the M/E shutdown is located in the engine room. Pressure switches are considered controls and therefore the pressure switch must be relocated outside the space. Relocation of the switch to be completed by a fire suppression service technician.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 17 January 2019
Resolution: Recieved e-mail photo from vessel rep. showing the pressure switch re-located outside the engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 17 April 2018
Resolved
Vessel must be dry-docked and inspected by a Coast Guard Marine Inspector prior to carrying passengers. This requirement is a result of a collision with a submerged navigation buoy and subsequent survey with a remotely operated underwater vehicle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2018
Resolution: Vessel dry-docked and inspected.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 5 November 2015
Resolved
Repair/replace PS water pump on MDE Pump has a slight leak.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Elbow on water pump replaced. Pump no longer leaking.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 November 2015
Resolved
Replace battery in all floating Lights. Buoy also.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 24 November 2015
Resolution: Battery replaced.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 5 November 2015
Resolved
Install fan heater cover in galley.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Cover installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 November 2015
Resolved
Remove excess Eng room oil containers.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Excess oil containers removed.
Engineering › Fuel Oil Service System › Valve
Issued 5 November 2015
Resolved
Label emergency fuel shut off valves.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Valves labeled.
Engineering › Steering Gear System › Feedback Unit
Issued 5 November 2015
Resolved
Secure auto pilot in steering space.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Auto pilot secured.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 November 2015
Resolved
Seal all bulk head holes. All bulk heads.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Bulkhead sealed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 November 2015
Resolved
Seal wire penetration in fore peak. Deck is staring to rot because of water intrusion.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Wire penetrations sealed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 November 2015
Resolved
Repair ladder STBD side "crew only" Ladder is secure but is cracked.
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Ladder repaired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 November 2015
Resolved
Provide the Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2015
Resolved 24 November 2015
Resolution: COD provided.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 26 August 2015
Resolved
Repair/replace fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 5 November 2015
Resolution: Fuel tank replaced and inspected.
Lifesaving › Lifefloat › Paddle
Issued 19 September 2011
Resolved
Replace broken paddle in life float.
Due 26 September 2011
Resolved 26 September 2011
Resolution: Replaced broken paddle.
Communications › Public Address System › Loudspeaker
Issued 19 September 2011
Resolved
Repair or replace FWD PA Speaker. Rep was able to make speaker functional but wiring and mount were lose.
Due 26 September 2011
Resolved 26 September 2011
Resolution: Properly mounted and wired FWD PA Speaker.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 September 2011
Resolved
Replace markings on emergency.
Due 26 September 2011
Resolved 26 September 2011
Resolution: Properly labeled escape route.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 September 2011
Resolved
Prove operation of smoke detector in FWD berthing.
Due 26 September 2011
Resolved 19 September 2011
Resolution: Rep connected battery smoke detector operational.
Documentation › Certificates/Documents › FCC SSL
Issued 10 September 2008
Resolved
Provide FCC radio station license.
Condition: Unknown
Due 10 October 2008
Resolved 10 February 2009
Resolution: FCC SL provided.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 10 September 2008
Resolved
Replace broken window in pilot house.
Condition: Damaged By Earlier Event
Due 10 October 2008
Resolved 10 February 2009
Resolution: Window replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 September 2008
Resolved
Provide U.S. Coast Pilot and Light List.
Condition: Unknown
Due 10 October 2008
Resolved 10 February 2009
Resolution: Coast pilot and light list provided.
Lifesaving › Lifefloat › Pendant
Issued 10 September 2008
Resolved
Replace pendants on lifefloats (1/4" polypropolene).
Condition: Improper/Lack of Maintenance
Due 10 October 2008
Resolved 10 February 2009
Resolution: Pendants replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 September 2008
Resolved
Remove dead ended cable in galley for old stove.
Due 10 March 2009
Resolved 3 April 2009
Resolution: Cable Removed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 September 2008
Resolved
Remove excess supplies from vessel.
Due 10 October 2008
Resolved 10 February 2009
Resolution: Excess supplies removed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 September 2008
Resolved
Provide access to secondary pulls to CO2 system.
Condition: Placed in Improper Service
Due 10 October 2008
Resolved 10 February 2009
Resolution: Access to secondary pull to CO2 system provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 August 2006
Resolved
Make repairs to Bilge alarm in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2006
Resolution: Alarm Rapaired
Lifesaving › Hand Flares › Quantity
Issued 29 August 2006
Resolved
Provide 6 additional red flares or orange smoke signaling devices prior to operating on a limited coastwise route.
Due 1 September 2006
Resolved 31 August 2006
Resolution: Flares provided
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 August 2006
Resolved
Clean mold and mildew off of all life jackets
Due 1 September 2006
Resolved 31 August 2006
Resolution: Life Jackets Cleaned
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 August 2006
Resolved
Restencil vessels name on life jackets as required
Due 1 September 2006
Resolved 31 August 2006
Resolution: Life Jackets Stenciled
Engineering › Bilge Water Management System › Interface Detector
Issued 29 August 2006
Resolved
Permanently mount bilge pump float switch in Engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2006
Resolution: Switch has been mounted
Stability › Watertight Integrity › General
Issued 29 August 2006
Resolved
Make repairs / secure water intrusion in to the engine room.
Due 1 October 2006
Resolved 1 November 2006
Resolution: Recieved phone call from VSl operator. Repairs completed
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 August 2006
Resolved
Restencil emergency fuel shut off placard.
Due 1 September 2006
Resolved 31 August 2006
Resolution: Fuel Shut off has beene stenciled
Construction/Loadline › Structures › Superstructure
Issued 1 September 2005
Resolved
Replace and renew all Rail caps on Starboard side.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Construction/Loadline › Structures › Superstructure
Issued 1 September 2005
Resolved
Repair water damage to starboard side/passenger compartment
Action required: 705 - Other - as specified
Resolved 20 September 2005
Construction/Loadline › Structures › Superstructure
Issued 1 September 2005
Resolved
Repair water damage to port side passenger compartment.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Construction/Loadline › Structures › Superstructure
Issued 1 September 2005
Resolved
Repair water damaged aft cap rail port side.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 1 September 2005
Resolved
Prove proper operation of Lazarette bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2005
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 1 September 2005
Resolved
Repair/ Remove all electrical grounding cables no longer used.
Due 15 September 2005
Resolved 20 September 2005
Engineering › Fuel Oil Service System › Filter
Issued 30 August 2005
Resolved
Fuel leaking from Racor Filters
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2005
Resolved 20 September 2005
Resolution: Repaired.
Engineering › Bilge Water Management System › Piping
Issued 30 August 2005
Resolved
Remove or replace dead ended piping
Condition: Unknown
Due 15 September 2005
Resolved 20 September 2005
Resolution: Piping Removed or capped
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 30 August 2005
Resolved
Excessive water leakage.
Condition: Unknown
Due 15 September 2005
Resolved 20 September 2005
Resolution: Shafts repacked
Engineering › Bilge Water Management System › Piping
Issued 30 August 2005
Resolved
Screens for Bilge suction heads missing or destroyed
Condition: Unknown
Due 15 September 2005
Resolved 20 September 2005
Resolution: Screens replaced as required
Engineering › Bilge Water Management System › Interface Detector
Issued 30 August 2005
Resolved
Lazarette Bilge alarm inoperable.
Condition: Unknown
Due 15 September 2005
Resolved 20 September 2005
Resolution: Sensor repalced, test sat
Electrical › Lighting (service) › Lighting Fixture
Issued 30 August 2005
Resolved
Light fixture in PORT/FWD Accomodation space damaged
Due 15 September 2005
Resolved 20 September 2005
Resolution: Light fixture replaced
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 30 August 2005
Resolved
Bus bar on Port MDE is exposed
Due 15 September 2005
Resolved 20 September 2005
Resolution: Lexan covers installed
Fire Fighting › Nozzles › Condition
Issued 30 August 2005
Resolved
Missing nozzle for fire hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2005
Resolved 20 September 2005
Resolution: Replaced Nozzle
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 30 August 2005
Resolved
Repair Discharge cage.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Cage repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 30 August 2005
Resolved
Fire extinguisher peridicity lapsed
Condition: Improper/Lack of Maintenance
Due 15 September 2005
Resolved 20 September 2005
Resolution: Fire extinguisher serviced
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 August 2005
Resolved
Thresh hold is rotted out on PORT side aft galley doorway.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Threshold repaired
Personnel › Certificates/Documents/Licenses › License, Master
Issued 30 August 2005
Resolved
Master of the vessel did not have license available.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Provided proof of CAPT license
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 August 2005
Resolved
Various pipes are dead ended thru the bulkheads on the vessel.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Pipes were removed or capped.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 August 2005
Resolved
Remove dead ended wires.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Wires removed
Stability › Watertight Integrity › General
Issued 30 August 2005
Resolved
All of the water tight hatches will not close properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2005
Resolved 26 October 2005
Resolution: Chalk test- SAT
Stability › Weathertight Integrity › General
Issued 30 August 2005
Resolved
Window on the bridge is fractured
Due 15 September 2005
Resolved 20 September 2005
Resolution: Por tlight has been replaced
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 August 2005
Resolved
Smoke detector for Accomodation space inoperable
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2005
Resolution: Replaced Smoke detector
Engineering › Bilge Water Management System › Piping
Issued 30 August 2005
Resolved
Check valve for Forward galley bilge is inoperable.
Due 15 September 2005
Resolved 20 September 2005
Resolution: Check valve repalced
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 August 2005
Resolved
VSL needs to conduct MOB drills with Coast Guard inspector.
Due 1 November 2005
Resolved 26 October 2005
Resolution: U/W MOB drill - SAT
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 September 2003
Resolved
Provide proof of enrollement in employee drug and acohol testing program.
Condition: Unknown
Due 4 October 2003
Resolved 9 September 2003
Resolution: drug and alcohol testing proof provide via fax dated September 9, 2003.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 4 September 2003
Resolved
IAW 46 CFR 183.420 Provide Coast Guard light list.
Due 4 October 2003
Resolved 17 September 2003
Resolution: Provided same.
Lifesaving
Issued 9 September 1999
Resolved
REMOVE COMPARTMENT HEATER FROM STEERING COMPARTMENT OR INSTALL APPROVED MARINE TYPE THAT IS PROPERLY WIRED INTO VESSEL.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Engineering
Issued 9 September 1999
Resolved
PROPERLY MOUNT, WITH METAL BRACKETS ALL FUEL LINES IN ENGINEROOM_x001C_ COMPARTMENT.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Lifesaving
Issued 9 September 1999
Resolved
UPDATE EMERGENCY PROCEDURES TO REFLECT NEW CO2 FIRE SYSTEM.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Lifesaving
Issued 9 September 1999
Resolved
POST EMERGENCY BROADCAST PROCEDURES ON BRIDGE AND LIFE JACKET DONNING PROCEDURES ON MAIN DECK.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Fire Fighting
Issued 9 September 1999
Resolved
MAKE ALL SMOKE DETECTORS ON BOARD OPERATIONAL.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Fire Fighting
Issued 6 September 1995
Resolved
IN ACCORDANCE WITH 46 CFR 181.15-10, PROVIDE A BRONZE OR SIMILAR METAL NOZZLE FOR THE FIRE HOSE.
Condition: Unknown
Due 13 September 1995
Resolved 14 September 1995
Engineering
Issued 6 September 1995
Resolved
IN ACCORDANCE WITH 46 CFR 182.20-35, PROVIDE A 30X30 MESH FLAME SCREEN IN THE FUEL TANK VENT LINE.
Condition: Unknown
Due 13 September 1995
Resolved 14 September 1995
Accommodation/Occupational Safety
Issued 5 October 1993
Resolved
PROVIDE AND PROPERLY POST AN UPPER DECK PASSENGER CAPACITY PLACARD IN ACCORDANCE WITH THE VESSEL'S STABILITY LETTER NO LATER THAN 12OCT93.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Construction/Loadline
Issued 12 September 1992
Resolved
REMOVE APPROXIMATELY 3-4 TONS OF ADDED BALLAST IN LAZARETTE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1992
Resolved 14 September 1992
Engineering
Issued 10 October 1991
Resolved
REMOVE WIRE HARNESS FROM MAIN ENGINE'S JACKET WATER LINE.
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Engineering
Issued 10 October 1991
Resolved
DO NOT OPERATE SMALL AUTOMATIC HOT WATER BOILER UNTIL INSTALLATION, INSPECTION AND TESTING IS CONDUCTED BY A COAST GUARD MARINE INSPECTOR TO ENSURE COMPLIANCE WITH 46 CFR 63.25-3(j)
Condition: Unknown
Due 6 April 1992
Resolved 7 April 1992
Construction/Loadline
Issued 10 October 1991
Resolved
PLUG UNUSED SCUPPER DRAINS THROUGH HULL CONNECTIONS PORT AND STARBOARD._x001C_
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Electrical
Issued 10 October 1991
Resolved
PROVIDE COVERS FOR AC/DC ELECTRICAL PANEL BOXES.
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Accommodation/Occupational Safety
Issued 10 October 1991
Resolved
REPAIR LEAKING HOT WATER LINE IN CREW'S COMPARTMENT.
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Electrical
Issued 10 October 1991
Resolved
DISCONNECT AND DO NOT OPERATE ELECTRIC STORAGE TANK HOT WATER SUPPLY HEATERUNTIL DOCUMENTATION IS PROVIDED SHOWING UNIT IS BUILT IN ACCORDANCE WITH USSTANDARDS 174 0R 1453 46 CFR 63.15.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Navigation
Issued 17 September 1991
Resolved
PROVIDE BELL MADE OF CORROSION RESISTANT MATERIAL AND DESIGNED TO GIVE CLEAR TONE. THE DIAMETER OF THE MOUTH OF THE BELL SHALL NOT BE LESS THAN 200MM (7.9 INCHES)._x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Engineering
Issued 17 September 1991
Resolved
INSTALL FLEXIBLE DIESEL FUEL HOSES TO S/S GENERATOR IN ACCORDANCE WITH_x001C_ 46 CFR 182.20-40 (a)(2)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
INSTALL RAILING FOR STAIRWAY LEADING TO BELOW DECK ACCOMODATIO SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
INSTALL DECK RAILING ON TRANSOM OPENING IN ACCORDANCE WITH 46 CFR 177.35-1.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Documentation
Issued 17 September 1991
Resolved
POST STABILITY LETTER UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL INPILOTHOUSE IAW 46 CFR 185.12-1._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
ALL ESCAPE HATCHES AND OTHER EMERGENCY EXITS SHALL BE MARKED ON BOTH SIDES USING AT LEAST 1 INCH LETTERS: "EMERGENCY EXIT, KEEP CLEAR".
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Documentation
Issued 17 September 1991
Resolved
PREPARE AND POST EMERGENCY CHECKOFF LIST IN A CONSPICUOUS PLACE ACCESSIBLE TO CREW AND PASSENGERS IAW 46 CFR 185.25-1 AND 46 CFR 185.25-5._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Lifesaving
Issued 17 September 1991
Resolved
THE NUMBER OF PERSONS ALLOWED ON EACH BUOYANT APPARATUS SHALL BE CONSPICUOUSLY MARKED OR PAINTED THEREON IN LETTERS AND NUMBERS AT LEAST 1.5INCHES HIGH IAW 46 CFR 185.30-5(b).
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Lifesaving
Issued 17 September 1991
Resolved
LIFE PRESERVER STOWAGE CONTAINERS SHALL BE MARKED "LIFE PRESERVERS" AND THENUMBER CONTAINED WITHIN, IN AT LEAST 1 INCH LETTER AND FIGURES THIS LEGEND SHALL INDICATED THE SEPARATE STOWAGE OF CHILDRENS LIFE PRESERVERS IAW 185.30-10._x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Documentation
Issued 17 September 1991
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION ISSUED BY THE COAST GUARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
PROVIDE PLANS FOR ELECTRIC STORAGE TANK HOT WATER SUPPLY HEATER OR PROVIDE EVIDENCE THAT ELECTRIC WATER HEATER IS LISTED UNDERWRITERS LABORATORIES AS MEETING UL STANDARDS 174 OR 1453._x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Engineering
Issued 17 September 1991
Resolved
DO NOT OPERATE SMALL AUTOMATIC HOT WATER BOILER UNTIL CONSTRUCTION INSTALLATION, INSPECTION AND TESTING IS CONDUCTED BY A COAST GUARD MARINE INSPECTOR TO ENSURE COMPLIANCE WITH 46 CFR 63.10
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Accommodation/Occupational Safety
Issued 17 September 1991
Resolved
FRESH WATER PRESSURE TANKS SHALL BE FITTED WITH SAFETY RELIEF VALVES, SET TO RELIEVE BELOW THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE TANK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Documentation
Issued 17 September 1991
Resolved
PROVIDE AND POST FCC SAFETY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991