← All vessels
JO CALLUNA
JO CALLUNA is a 1986 tank ship. The Coast Guard has recorded 54 inspections since 1991, most recently in May 2009, along with 10 deficiencies and 8 operational controls.
Records from 1991 to 2009. Most recent: inspection, 9 May 2009.
- Built
- 1986
- Last inspected
- 9 May 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8500604 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAFJ6
363739
Flag
NORWAY
—
Maury page id
psix-363739
Inspections, by type
…with no type recorded25
Years with a record
15 calendar years (1991–2009)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8002 - Convention (Subpart B), Gross Ton
4373 - Convention (Subpart B), Net Ton
12186 - Dead Weight, Ton
16608 - Displacement, Ton
4373 - Convention (Subpart B), Net Ton
12186 - Dead Weight, Ton
16608 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 54
9 May 2009
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3470852
8 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3445327
14 March 2009
MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex I Examination · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3430882
11 March 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3431905
17 February 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3418807
20 June 2008
PII Safety Exam · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3242263
19 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3241738
15 October 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3080106
21 July 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3002301
22 June 2007
COC-CHEM Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2970260
24 January 2007
MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2860429
24 July 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2722920
16 July 2006
COC-CHEM Renew · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2713903
3 March 2006
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2595195
1 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2595187
8 November 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2541167
26 October 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2522636
22 October 2005
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2520011
5 September 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2491141
2 September 2005
ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2490574
31 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2452141
24 July 2005
MARPOL Annex V Examination · COC-CHEM Annual · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2437393
3 June 2005
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2378348
7 April 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2567706
3 April 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2325429
22 November 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2245753
2 August 2004
PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2153166
22 July 2004
PII Safety Exam · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2137902
22 July 2004
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2137943
14 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2007416
23 July 2003
Ballast Water Examination · Letter of Compliance (Initial/Renewal)
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1854802
10 April 2002
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1603352
17 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062516
18 April 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276987
18 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1048561
2 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433369
10 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429520
7 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429415
7 June 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 806037
7 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096439
28 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 26318
18 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 419487
18 June 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 797223
28 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 414423
28 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1445330
23 July 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 845059
25 May 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 358444
7 May 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146572
10 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 485332
5 January 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1133673
4 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464393
13 March 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1438000
12 March 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 463339
13 August 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 936199
Deficiency record · 10
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 20 June 2008
Resolved
Vessel did not have calibration gas for the portable gas detection units. Vessel has 07 days to rectify the deficiency to the satisfaction of the coast guard.
Navigation › Piloting/Steering › Gyro Compass
Issued 8 November 2005
Resolved
Vessel's Gyro Compass inoperable prior to entering the port. In bound deviation was granted on 08NOV05.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 22 July 2004
Resolved
Prior to departure from St. Croix discharge slops ashore.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 22 July 2004
Resolved
Make repairs to the O.D.M.E. Until corrected discharge to the sea to be blocked and slopes retained aboard. To be corrected to the satisfaction of class, flag state surveyor at next U.S. port which has been reported to be Houston, TX.
Engineering › Steam System (main)
Issued 10 April 2002
Resolved
Several Section of insulation for main steam line on deck missing or wasted. In particular, foward of mid-ship area.. Repair as new. Class/Flag report attesting to correction can be accepted. LEGACY COMPONENT DESC: Piping
Deck/Cargo › Cargo Heating
Issued 10 April 2002
Resolved
Insulation missing on Portside line, inside heating room. Class/Flag report attesting to correction can be accepted. LEGACY COMPONENT DESC: Steam Line in heating room
Deck/Cargo
Issued 7 June 1999
Resolved
PRIOR TO LOADING CARGO PROVE PROPER OPERATION OF CARGO OVERFILL AUDIO/VISUAL ALARMS ON DECK.
Navigation
Issued 28 March 1998
Resolved
Repair and prove proper operation of Autopilot/tiller overrule and associated alarm.
Fire Fighting
Issued 23 July 1993
Resolved
SERVICE PORTABLE AND SEMIPORTABLE FIRE EXTINGUISHERS AND PROVIDE SERVICING REPORT TO COGNIZANT OCMI AT NEXT U.S. PORT.
Lifesaving
Issued 23 July 1993
Resolved
PROVIDE REPORT THAT THE SELF CONTAINED BREATHING APPARATUS ONBOARD HAS_x001C_ BEEN PROFESSIONALLY SERVICED WITHIN LAST 12 MONTHS TO COGNIZANT OCMI AT NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.