Records from 2016 to 2026. Most recent: inspection, 9 February 2026.
Inspection history · 18
9 February 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8298598
27 January 2026
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8298585
1 May 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8127036
30 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7904092
20 February 2024
Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7867406
22 May 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694188
14 March 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7411763
4 February 2022
Drydock Exam · Damage Survey · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7391132
22 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7179826
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108421
29 January 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6898694
27 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6650107
6 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6351006
2 February 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6348611
30 March 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6114153
29 March 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116935
4 April 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5846560
31 March 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5844773
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 May 2025
Resolved
Interconnected detection and alarm system must be installed that actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d). Vessel had detectors in all staterooms but no strobe/visual in rooms. Provide evidence system meets regulation intent.
46 CFR 181.450(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 6 May 2025
Resolution: See narrative for full description, all sat.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 1 May 2024
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. Vessel name on port and starboard bow was missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 2 May 2024
Resolution: Vessel name affixed to port and starboard bow of vessel.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 May 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not updated to reflect vessel name change.
Action required: 10 - Deficiency Rectified
Due 1 May 2024
Resolved 1 May 2024
Resolution: Master updated vessel information on emergency broadcast placard before inspection team departed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2024
Resolved
Each battery must be secured to protect against shifting with roll and pitch of the vessel. Engine batteries were not secured to the deck.
Action required: 10 - Deficiency Rectified
Due 1 May 2024
Resolved 1 May 2024
Resolution: Batteries were secured before inspection team departed vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Multiple appliances were plugged into surge protector in accommodation spaces. Junction boxes in engine room not secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 4 May 2024
Resolution: Secured junction boxes.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 May 2024
Resolved
Each class 1 door on a vessel in ocean service must be designed to withstand a head of water. Securing dogs on class 1 watertight door leading to engine room were loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 4 May 2024
Resolution: Tightened dogs on watertight door.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024
Resolved
Portable fire extinguishers must be installed to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher bracket in generator room was loose and not secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 4 May 2024
Resolution: Secured bracket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be effectively insulated and protected. Lagging on port engine exhaust system was not fully secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 1 May 2024
Resolution: Secured exhaust lagging
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Missing flame screens or flame arrestors on fuel tank vent pipes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 10 May 2024
Resolution: Vessel installed appropriate flame screens covering discharge ends of fuel tank vent pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2024
Resolved
With any ships service generating set stopped, the combined capacity of the remaining electric ship's service must be sufficient for the ship's service load. Engines secured when switching generator power.
Action required: 10 - Deficiency Rectified
Due 1 May 2024
Resolved 1 May 2024
Resolution: Owner replaced batteries, tested generators and switched loads. Generators tested sat, engines service load remained sufficient. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2024
Resolved
Standby vessels must have a fire monitor with a minimum flow rate of at least 500 gallons per minute. Vessel fire monitor pump did not energize to produce the minimum flow rate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 2 May 2024
Resolution: Vessel owner provided video of fire monitor operating as designed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 May 2023
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources. Emergency lighting was inoperable.
46 CFR 183.310
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2023
Resolved 24 May 2023
Resolution: MI witnessed e-power come on and all e-lighting was operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2023
Resolved
A fire hose with a nollze must be attached to each fire hydrant at all times. Fire hose nozzle was wasted and needs to be replaced.
46 CFR 181.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 24 May 2023
Resolution: Received pictures and receipts for new fire hose nozzles.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 May 2023
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC stations documents need to be renewed with new owner/operator.
47 CFR 80.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 7 June 2023
Resolution: Received updated FCC certificates with new owner/operator.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 March 2022
Resolved
VESSEL MUST CARRY UP TO DATE CHARTS.
CHARTS FOR VESSELS OPERATING AREA WERE OUTDATED.
46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 29 March 2022
Resolution: Updated charts.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 14 March 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 29 March 2022
Resolution: Replaced expired batteries.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2022
Resolved
INSPECTION OF PIPING, CONTROLS, AND VALVES TO DETERMINE THAT THE SYSTEM IS IN OPERATING CONDITION.
FIRE MAIN VALVE WAS LEAKING.
46 CFR 176.810(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 13 April 2022
Resolution: Vessel rep provided photographic evidence.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2022
Resolved
PUMP OUTLET MUST BE FITTED WITH A PRESSURE GAUGE.
PRESSURE GAUGE ON BILGE PUMP WAS INOPERABLE.
46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 29 March 2022
Resolution: Rep provided video of functional guage.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 March 2022
Resolved
INSPECTION OF EACH PORTABLE FIRE EXTINGUISHER TO CHECK FOR EXCESSIVE CORROSION AND GENERAL CONDITION.
CO2 EXTINGUSHER IN GENERATOR ROOM HAD A COLLAPSED/CRACKED HORN.
46 CFR 176.810(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 29 March 2022
Resolution: Replaced horn/hose for CO2 extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2022
Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED TO AFFORD PROTECTION FROM MACHINERY FAILURE.
CLUTCH ACTUATOR BRACKETS ON #1 AND #4 MDE WERE WORN, EXTRA BOLT ADDED TO TEMPORARILY HOLD IN PLACE.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2022
Resolved 13 April 2022
Resolution: Vessel rep provided photographic evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2022
Resolved
TWO CLAMPS MUST BE USED ON EACH OF THE HOSE.
JACKET WATER PIPING ON THE #5 MDE WAS MISSING THE SECOND CLAMP.
46 CFR 182.410(d)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 15 March 2022
Resolution: Applied second clamp to secure flexible piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 March 2022
Resolved
ALL REQUIRED GUARDS AND PROTECTIVE DEVICES MUST BE IN SATISFACTORY CONDITION.
FIRE PUMP ROTATING MACHINERY GUARD CAME OFF DURING INSPECTION. BELT GUARD ON AIR COMPRESSOR WAS SECURED INPROPERLY.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 15 March 2022
Resolution: Properly secured rotating machinery guards on fire pump and air compresser.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 March 2022
Resolved
EACH CLASS 1 DOOR ON A VESSEL MUST BE DESIGNED TO WITHSTAND A HEAD OF WATER.
BOTH CLASS 1 DOORS FOR ENGINE ROOM WERE LOOSE AND NOT PROVIDED A COMPLETE WATERTIGHT SEAL.
46 CFR 170.270(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 15 March 2022
Resolution: Tightened dogs on doors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2022
Resolved
Vessel overdue for DDX. Conduct DDX to satisfaction of CG.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 February 2022
Resolved 8 February 2022
Resolution: Vsl in drydock, CG inspected, correcting worklist items.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 March 2019
Resolved
Hatch leading to machinary space in laundry room not watertight due to incomplete dogging of door.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 28 March 2019
Resolution: VSL rep replaced bar on hatch, picture uploaded into documents.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 March 2019
Resolved
Plugs for water vents on aft deck missing
New T: 177.115 leads you to
OLD T: 177.20-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 28 March 2019
Resolution: Vsl rep bought and painted plugs for vents picture uploaded into documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 March 2019
Resolved
Check valve on laundry overboard discharge outlet not installed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 28 March 2019
Resolution: Vsl rep installed check valve, picture uploaded into documents.