← All vessels
VELOS
Freight Ship · Bulk Carrier class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named VELOS
VELOS is a 1991 freight ship. The Coast Guard has recorded 24 inspections since 1991, most recently in July 2007, along with 18 deficiencies and 3 operational controls.
Records from 1991 to 2007. Most recent: inspection, 22 July 2007.
- Built
- 1991
- Last inspected
- 22 July 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8902216 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3GL9
363774
Flag
CYPRUS
—
Maury page id
psix-363774
Inspections, by type
…with no type recorded17
Years with a record
13 calendar years (1991–2007)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it36438 - Convention (Subpart B), Gross Ton
22310 - Convention (Subpart B), Net Ton
77275 - Displacement, Ton
65702 - Dead Weight, Ton
22310 - Convention (Subpart B), Net Ton
77275 - Displacement, Ton
65702 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
22 July 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3003454
26 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2877693
25 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2877164
25 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2906777
22 February 2006
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2587207
23 February 2005
ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2297542
29 June 2004
Random ISPS/MTSA/PSC · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2115672
8 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1717405
26 November 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1711263
26 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1711765
19 February 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1484643
2 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 162682
23 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286446
29 January 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 425098
10 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407681
12 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392207
22 June 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 379499
15 March 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 375877
23 December 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 363280
22 December 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 183821
23 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525563
1 July 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 352393
21 January 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 443045
8 June 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 344333
Deficiency record · 18
Construction/Loadline › Markings › Load Line Mark
Issued 26 November 2002
Resolved
Port and starboard loadline markings are not permanently marked in accordance with the loadline certificate.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 November 2002
Resolved
110 volt feeder panel in engine control room has a dead ground.
Navigation › Collision/Grounding Avoidance
Issued 26 November 2002
Resolved
Secondary marine radar is inoperable. LEGACY COMPONENT DESC: Radar
Navigation
Issued 23 January 2001
Resolved
Line diagram of steering system not posted in steering gear room. Post diagram.
Lifesaving
Issued 23 January 2001
Resolved
Expired medication in ships medical locker. Provide adaquate medical supplies by 27JAN01.
Construction/Loadline
Issued 23 January 2001
Resolved
Craked welds in way of cargo hatchway combing support members. Provide class report attesting to proper repairs.
Construction/Loadline
Issued 23 January 2001
Resolved
Water tight manway hatches for cargo hatches 1,2,3,4 & 6 not in working order. Provide class report attesting to proper repairs.
Navigation
Issued 23 January 2001
Resolved
Clean excess grease and oil from steering gear.
Lifesaving
Issued 15 March 1995
Resolved
Clean up the excessive oil from the steering gear & purifier room decks, prior to next U. S. port, per SOLAS Chpt II-2 Reg 2
Fire Fighting
Issued 15 March 1995
Resolved
Provide an approved extinguishing system to the paint locker, prior to nextU. S. port, per SOLAS Chpt II-2 Reg 18(7).
Fire Fighting
Issued 15 March 1995
Resolved
Make permanent repairs to the two inlet coolers for the main engine jacket water system. The lines have temp welded patches and are wasting through in several locations, complete prior to return to U. S. port, per SOLAS Chpt II-1 Reg 26(1).
Fire Fighting
Issued 15 March 1995
Resolved
Repair/replace the disabled closure devices on the fire doors to the steering gear space and the stbd, upper entrance to the engineroom. Remove hold back devices. Complete all items prior to return to a U. S. port, perSOLAS Chpt II-2, Reg 47(2)
Engineering
Issued 15 March 1995
Resolved
Place proper 1 BBL containment boxes about the port + stbd standard discharge connections (4 total), prior to next U. S. port, per 33 CFR 155.310(a)(1).
Engineering
Issued 23 December 1993
Resolved
33 CFR 155.750 Vessel did not have a lube oil diagram in the oil transfer procedures. Vessel personnel to create diagram prior to next port call._x001C_
Fire Fighting
Issued 23 December 1993
Resolved
Fire plans on the vessel were not labeled or marked. Vessel personnel to label plans prior to next port call._x001C_
Engineering
Issued 23 December 1993
Resolved
33 CFR 156.170(f)(2) Vessel's bunker system piping had not been liquid static pressure tested to 1 1/2 times the MAWP within the last year. Vessel to test prior to next port call._x001C_ _x001C_
Engineering
Issued 23 December 1993
Resolved
33 CFR 155.430 Vessel did not have a standard discharge connection on board. Vessel to acquire connection at next port call.
Accommodation/Occupational Safety
Issued 23 December 1993
Resolved
33 CFR 151.63 Vessel did not have a garbage log or plan to prove the vessel was in compliance with MARPOL V. Vessel's master agreed to create aplan and log prior to next port call._x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.