MAURY USCG vessel records Sign in
← All vessels

HALF MOON

HALF MOON is a 1991 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1991, most recently in July 2026, along with 74 deficiencies.

Records from 1991 to 2026. Most recent: inspection, 30 July 2026.

Built
1991
Last inspected
30 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

363820
Flag
UNITED STATES
—
Maury page id
psix-363820

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1991–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Simplified, Net Ton
3 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 44

30 July 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8450486
6 June 2025 COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8150914
12 August 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7981101
15 August 2023 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7768851
18 May 2023 Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7691630
14 July 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7511777
1 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7302714
5 June 2020 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6985051
28 August 2019 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6783642
24 July 2018 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6429508
29 March 2018 Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6379867
14 August 2017 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6236618
1 March 2017 Administrative Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6096917
15 September 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6001324
16 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4209301
12 July 2011 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4140253
6 May 2008 Annual Inspection · Deficiency Check · Hull Examination · DAPI Audit · Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3200143
1 September 2007 Re-Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3261535
22 August 2006 Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2755709
20 June 2005 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2396169
13 September 2004 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2383961
2 September 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1894326
19 June 2003 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1820567
30 September 2002 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1682044
24 August 2001 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1073370
5 July 2001 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1401517
13 July 2000 Deficiency Check · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1468149
16 June 1999 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1451418
24 May 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 799611
11 March 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 810061
14 September 1998 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 798726
26 June 1998 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1402682
16 June 1998 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1458546
27 June 1997 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1437273
11 June 1996 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 877197
15 May 1996 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1462502
5 July 1994 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1177019
29 June 1994 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1403803
14 June 1993 Re-Inspection · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1440711
22 May 1992 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 951382
12 May 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1257252
25 February 1992 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1260551
28 June 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 934226
11 June 1991 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1325644

Deficiency record · 74

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2026 Resolved
Vessel did not have corrosion resistant clip on lifering Add clip to the satisfaction of attending CG Marine Inspector. 46CFR 180.70d3
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 August 2026
Resolved 30 July 2026
Resolution: Vessel added clip.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2026 Resolved
Firebuckets were not labeled "fire bucket". Label bucket to the satisfaction of attending CG Marine Inspector. 46 CFR 181.60
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 August 2026
Resolved 30 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The material coating the life ring was found to be deteriorating. Repair or replace and reinstall life ring in accordance with 46 CFR 180.70.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 September 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 August 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol swabs were found expired. Replace alcohol swabs as required by 46 CFR 185.212 or ensure testing can be conducted within 2 hours of event.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 6 June 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 July 2022 Resolved
Bilge high level alarm did not have an operable visual indicator. Resolve to the satisfaction of a CG Marine Inspector. 46CFR182.530 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 3 August 2022
Resolution: Visual indicator was installed. Test Sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 July 2022 Resolved
Automatic bilge pump did not have a visual indicator to show when it is in operation. Resolve to the satisfaction of a CG Marine Inspector. 46 CFR 182.530 (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 3 August 2022
Resolution: Visual indicator was installed. Test Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 July 2022 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Floating water-light battery was expired. Resolve to the satisfaction of a CG Marine Inspector. 46 CFR 185.726 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 3 August 2022
Resolution: Entire light was replaced. Test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2022 Resolved
Ring life buoy was missing its grab-line. Repair or replace to the satisfaction of a CG Marine Inspector. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 3 August 2022
Resolution: Ring buoy was replaced, marked and stowed properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2022 Resolved
First aid kit contained expired contents. First aid kit did not contain a complete inventory. Outfit first aid kit with unexpired items and contents listed under approval 46 CFR 160.041. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 3 August 2022
Resolution: First aid kit was replaced with a new kit conforming to to 46CFR160.710
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 September 2021 Resolved
During the inspection the owner/operator was unable to provide the inspector with an updated inspection report for the vessels fixed fire extinguishing system and portable fire extinguishers. For fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 9 September 2021
Resolution: received report via email for extinguisher and fireboy servicing
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2019 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessels high water alarm not functioning. Replace or repair per manufacturers instructions to satisfaction condition and to the approval of an attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 19 September 2019
Resolution: Repaired to satisfaction condition and to the approval of an attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit has expired and missing items. Have first aid kid made satisfactory to an attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 19 September 2019
Resolution: First aid kid made satisfactory to the attending Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 24 July 2018 Resolved
Each officer employed on any vessel subject to 46 CFR Subchapter T, must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Vessel operators do not carry original credential while operating vessel. Carry original credential while vessel is in operation and have medical certificates available for examination.
Action required: 10 - Deficiency Rectified
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 July 2018 Resolved
The onboard emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instruction for man over-board (MOB) do not address the actual procedures of the vessel. Make emergency instructions as to the actual procedures of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2018
Resolution: Made emergency instructions as to the actual procedures of the vessel.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 24 July 2018 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drills are not sufficient. Perform MOB drills more frequently and log with firefighting, training and abandon ship drills. Date of drill or rainingand a general description shall be documented. MOB drill will be conducted at next annual (2019) utilizing Coast Guard chosen 02 Masters of the HALFMOON.
Action required: 705 - Other - as specified
Resolved 19 September 2019
Resolution: Satisfactory MOB drill conducted utilizing Coast Guard chosen 02 Masters of the HALFMOON.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2018 Resolved
A vessel of not more than 26 feet in length must carry a minimum of one life buoy of not less than 20 inches in diameter approved in accordance with 46 CFR 160.050. Life buoy grab line was wasted and buoy covering was badly lacerated. Replace/repair life buoy as per manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: Replaced life buoy as per manufacturer specifications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2018 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have life jacket donning placards posted. Vessel must provide life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: Vessel provided life jacket donning placard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 July 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel did not have up-to-date charts for intended voyage. Vessel must provide updated charts for intended voyage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: Vessel provided updated charts for intended voyage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2018 Resolved
A vessel not required to have a power driven fire pump must have three 2.5 gallon buckets, with an attached lanyard, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have fire buckets. Provide fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: Vessel provided fire buckets.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 August 2017 Resolved
CLEAN BILGES TO ENSURE ALL ACCUMULATED OIL HAS BEEN REMOVED AND DISPOSED OF PROPERLY.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 6 September 2017
Resolution: Bilges cleaned, no leak detected.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 14 August 2017 Resolved
PROVIDE COPY OF FULL LICENSE AND EMAIL TO ATTENDING CG MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 6 September 2017
Resolution: Observed
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 September 2016 Resolved
Display vessel homeport on stern.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 3 March 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2016 Resolved
Provide anchor light where it can best be seen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 3 March 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 20 September 2016 Resolved
Provide proper mounting bracket for the forward A-II portable fire extinguisher.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 3 March 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 20 September 2016 Resolved
Remove aft engine cover soundproof insulation that is covering engine space vent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 3 March 2017
Stability › Unintentional Flooding › General
Issued 20 September 2016 Resolved
Prove proper operation of high water bilge alarm, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2016
Resolved 20 September 2016
Resolution: Deficiency corrected prior to departure
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 12 July 2011 Resolved
Perform annual service on portable fire extinguishers and fixed extinguishing system in engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2011
Resolved 12 July 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 July 2011 Resolved
Renew ring buoy light lanyard.
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 12 September 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 July 2011 Resolved
Stencil vessel name on ring buoy.
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 12 September 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 July 2011 Resolved
Replace 03 adult PFDs. COI passenger count reduced to 24 passengers until PFDs replaced.
Action required: 705 - Other - as specified
Resolved 12 September 2011
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 July 2011 Resolved
Replace fuel tank vent and screen.
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 12 September 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2011 Resolved
Renew expired items in first aid kit.
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 12 September 2011
Lifesaving › Lifebuoys › Serviceable
Issued 20 May 2008 Resolved
Provide new ring buoy and properly attach heaving line around body of ring buoy.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Engineering › Bilge Water Management System › Hose
Issued 6 May 2008 Resolved
Make proper repairs to leaking bilge pump hose.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Resolution: Replaced hose
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 May 2008 Resolved
Install new retro tape or replace child size PFD's as needed.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Resolution: Purchased new child size pfd''s.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 May 2008 Resolved
Provide vent clousures for engine box.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 May 2008 Resolved
Provide PFD donning placards.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2008 Resolved
Replenish First Aid kit as needed.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Construction/Loadline › Hull › Keel Plate
Issued 6 May 2008 Resolved
Provide repair proposal for delaminated area at top of keel in bilge forward of engine ivo bilge pump, prior to operating in 2009 season.
Action required: 705 - Other - as specified
Due 1 May 2010
Resolved 11 June 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 22 August 2006 Resolved
complete annual testing of fixed firefighting system (Halon 1301) Carry additional B:C II portable fire extinguisher and make visual check of engine space every 15 minutes until corrected/ Granted a 1 day extension for replacement of cylinder. KPB.
Due 30 August 2006
Resolved 31 August 2006
Resolution: Received fax certification of installation of FE-341 2.5-3 lb bottle with new system status indication light with satisfactory operation of over ride system. New installation good for 75 sqft, with actual requirement of 60 sqft. Updated MISLE data.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 22 August 2006 Resolved
submit MIS report for 2005 to CGHQ G-MOA-1
Due 22 September 2006
Resolved 31 August 2006
Resolution: Received copy of MIS submission and discussed with o/o of requirements receiving report that they are seeking a new consortium.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 20 June 2005 Resolved
Replace leaking fuel pump, upon replacement prove proper operation of propulsion system
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 21 June 2005
Resolution: Witnessed satisfactory replacement of fuel pump and operation.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 June 2005 Resolved
Replace retro reflective material on 3 adult, and replace all child jackets.
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 21 June 2005
Resolution: Received faxed bill for new life jackets adult and child.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 September 2004 Resolved
Replace broken mounting bracket for b1 fire extinguisher.
Due 13 September 2004
Resolved 13 September 2004
Resolution: New bracket on scene and replaced prior to my departure.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 2 September 2003 Resolved
Conduct tests of fixed fire extinguisher with professional servicing and USCG Marine Inspector.
Due 2 October 2003
Resolved 13 September 2004
Resolution: Witnessed satisfactory testing of fixed system and witnessed servicing certificates of all ff equipment.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 September 2003 Resolved
Replace condemned life ring buoy with USCG approved ring buoy.
Due 16 September 2003
Resolved 13 September 2004
Resolution: New ring installed with appropriate marking and retro tape.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 30 September 2002 Resolved
Service fixed fire extringuishing system in engine compartment.
Due 15 October 2002
Resolved 19 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 30 September 2002 Resolved
Provide replacement fire extinguisher bracket.
Due 15 October 2002
Resolved 19 June 2003
Lifesaving
Issued 5 July 2001 Resolved
Aspirin and Eye wash in First Aid kit expired. O/O to correct.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Engineering
Issued 5 July 2001 Resolved
Fuel line chaffing on adjacent filter. Fuel line to be replaced
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 5 July 2001 Resolved
Polyproplene line on Life Ring Buoy was decomposed by sunlight. Line or the Ring Buoy must be replaced
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Engineering
Issued 13 July 2000 Resolved
repair/correct excessive leakage from the raw water pump on front of engine
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Lifesaving
Issued 13 July 2000 Resolved
post emergency procedures (185.510)
Condition: Unknown
Due 13 July 2000
Resolved 14 July 2000
Lifesaving
Issued 13 July 2000 Resolved
mark ring bouy with vessel name (185.604)
Condition: Unknown
Due 13 July 2000
Resolved 14 July 2000
Fire Fighting
Issued 11 March 1999 Resolved
VESSEL NOT TO OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW FIXED FIRE EXTINGUISHING SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Documentation
Issued 16 June 1998 Resolved
Provide evidence of acceptable drug testing program.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Fire Fighting
Issued 16 June 1998 Resolved
Service fire extinguishers stamped with date older than 1998.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 16 June 1998 Resolved
Provide on board emergency instructions checkoff list.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 16 June 1998 Resolved
Provide on board PFD donning instructions.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Electrical
Issued 16 June 1998 Resolved
Provide on board a second flashlight.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 16 June 1998 Resolved
Provide provisions for recording passenger count dockside.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 16 June 1998 Resolved
Provide periodic drill instruction for vessel's crews and document.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 16 June 1998 Resolved
Institute public safety announcements to be recited by vessel captains prior to getting underway.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 15 May 1996 Resolved
Post emergency broadcast placard in accordance with the requirements of 46 CFR 184.505/.510 [NEW T] to the satisfaction of the attending USCG marine inspector.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996 Resolved
Renew to the satisfaction of the attending USCG marine inspector the ring buoy handline.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 15 May 1996 Resolved
Demonstrate to the satisfaction of the attending USCG marine inspector_x001C_ that the vent pipe for the diesel fuel tank has a 30 x 30 mesh flame screenor flame arrester meeting the provisions of 46 CFR 182.20-35(d) [OLD T].
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Unknown
Issued 15 May 1996 Resolved
Provide evidence of compliance with the Drug Testing Program requirements of 46 CFR 16 to the satisfaction of the attending USCG marine inspector.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 29 June 1994 Resolved
40 gallon aluminum diesel fuel tank leaking at fuel tank top access plate as a result of access plate being improperly secured with wing nuts w/o lock washers. Prove to satisfaction of OCMI leak free condition of fuel tank.
Condition: Unknown
Due 29 June 1994
Resolved 12 July 1994
Lifesaving
Issued 29 June 1994 Resolved
Remove diesel fuel and residues in bilge in way of fuel tank.
Condition: Unknown
Due 29 June 1994
Resolved 12 July 1994
Fire Fighting
Issued 29 June 1994 Resolved
Prove to the satisfaction of the attending marine inspector that the fixed fire fighting system halon cylinder is properly charged.
Condition: Unknown
Due 5 July 1994
Resolved 13 July 1994
Documentation
Issued 28 June 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Navigation
Issued 28 June 1991 Resolved
VESSEL MUST HAVE UPDATED CHARTS PRIOR TO OPERATION.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Navigation
Issued 28 June 1991 Resolved
PRIOR TO OPERATION VESSEL MUST HAVE ON BOARD COAST PIOLT, LIGHT LIST,_x001C_ RULES OF ROAD AND TIDE TABLE.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.