Records from 2007 to 2026. Most recent: inspection, 30 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
30 May 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8387207
19 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8271525
5 August 2025
Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8243485
4 August 2025
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8208413
11 April 2025
Annual Inspection · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8131921
28 August 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7991810
28 August 2024
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7996009
20 June 2024
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7938805
22 May 2024
COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7915514
4 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7791494
4 August 2023
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7762413
20 June 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7483051
24 February 2022
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7401574
8 September 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7307115
11 June 2021
Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7224722
11 June 2021
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7247009
25 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7158983
29 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7051989
30 May 2019
Deficiency Check · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6698739
26 June 2018
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6392365
13 June 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6174265
2 May 2016
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5867627
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 August 2025
Resolved
Vessel is experiencing vibration issues due to damaging the prop during a recent grounding. Vessel owner/operator shall repair or replace the propeller to ensure safe and proper operation of the vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2025
Resolved 7 August 2025
Resolution: Vessel's prop was resurfaced and the vessel no longer is experiencing vibration issues.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Vessels high water indicating alarm float swith was removed during engine replacement and not re-installed. Make frequent rounds of engine space to ensure no flooding. Repair high water alarm to the satisfaction of attending CG Marine Inspector.
46 CFR 182.530
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 May 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 August 2024
Resolved
Operator notified OCMI after the vessel experienced a loss of propulsion. Vessel reported that the control cable for the reduction gear failed, resulting in the gear being stuck in reverse. Repair to the satisfaction of attending Coast Guard Marine Inspector prior to carrying passengers.
46CFR185.202
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2024
Resolved 29 August 2024
Resolution: New shift cable installed and tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2024
Resolved
Conduct and log man overboard, fire, and abandon ship drills with newly reported crewmembers and every 3 months. Provide Coast Guard Marine Inspector objective evidence (log book) of drills conducted.
46 CFR 185.420&
46 CFR 185.520&
46 CFR 185.524
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 28 May 2024
Resolution: Objective evidence provided (log)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 May 2024
Resolved
Label life jacket stowage under embarkation ladder on starboard side to the satisfaction of attending Coast Guard Marine Inspector.
46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 20 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2024
Resolved
Outfit first aid kit with the contents of 46 CFR 199.175(b)(10).
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 20 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 May 2024
Resolved
Certificate of Documentation is expired. Objective evidence of renewal application submission was provided to marine inspector. Provide a copy of the COD to attending CG Marine Inspector upon receipt.
46 CFR 67
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 20 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2023
Resolved
Vessels Shaft slid from the engine coupling and therefore damaged the shaft. Vessel Owner/Operator shall repair or replace the shaft to esnure proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2023
Resolved 14 September 2023
Resolution: Vessels shaft, bearing and coupling were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021
Resolved
The vessels float light battery was noticed to be expired. The vessel owner/operator shall replace the battery with a new battery of the approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 21 September 2021
Resolution: Vessel operator replaced float light battery with new battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021
Resolved
The forward lifering labeling and refelective tape were found deteriorated. The vessel owner/operator shall replace with Solas type reflective tape and replace the lettering to ensure the vessels name is legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 21 September 2021
Resolution: Vessel Operator replaced the lettering and reflective tape on the life ring with appropriate lettering and reflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021
Resolved
The forward lifering was not supplied with a bracket. The vessel owner/operator should develop a system to hang the lifering to ensure the lifering is always stored in the same location.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 21 September 2021
Resolution: Vessel operator supplied and installed the vessel with a bracket for the lifering.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 September 2021
Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets. Vessel was only supplied with 2 buckets, vessel owner/operator shall supply the vessel and crew with a 3rd fire bucke
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 21 September 2021
Resolution: Vessel operator bought and marked a new fire bucket for the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 June 2021
Resolved
Loss of propulsion control due to a failure of throttle mechanism.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2021
Resolution: Replaced throttle. Op tested new throttle. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2021
Resolved
Machinery and equipment installed on each vessel must be
suitable for the vessel and its operation and for the
purpose intended. All machinery and equipment must be
installed and maintained in such a manner as to afford
adequate protection from machinery failure. While
conducting an inspection of the vessel’s shaft bearing,
it was noted that the bearing was cracked and showing
signs of delamination from the metal housing. Any
cracking and/or delamination found on the rubber part of
the bearing must be replaced prior to the vessel
returning to service. Replace unsatisfactory bearing to
satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2021
Resolution: Replaced unsatisfactory bearing to satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 May 2019
Resolved
A vessel must be provided with an auxiliary means of
steering. Vessel's auxiliary means of steering is their
bow thruster which is operating intermittently.
Auxiliary means of steering must be repaired to the
satisfaction of attending Marine Inspector and
operationally tested while underway. Rectify prior to
the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
Resolution: Auxiliary means of steering repaired to the satisfaction of attending Marine Inspector and operationally tested while underway
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2019
Resolved
A submersible electric bilge pump may be used as a power
bilge pump provided that the pump is listed by an
independent laboratory as meeting the requirements in UL
1113. Submersible electric bilge pump located in void
under galley did not indicate it was UL 1113 listed.
Provide proof of proper UL listing or replace with
satisfactory bilge pump to the satisfaction of attending
Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 28 June 2019
Resolution: Replace with satisfactory bilge pump to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2019
Resolved
Each child size life jacket must be stowed in a location
that is appropriately marked and separated from adult
life jackets so the child size life jackets are not
mistaken for adult life jackets. Life jacket box in bow
is not marked. Satisfactorily mark location of life
jackets in forward stowage box to the satisfaction of
the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 28 June 2019
Resolution: Satisfactorily marked location of life jackets in forward stowage box to the satisfaction of
the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 May 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets, with
an attached lanyard satisfactory to the cognizant OCMI,
placed so as to be easily available during an emergency.
The words “FIRE BUCKET” must be stenciled in a
contrasting color on each bucket. The words “FIRE
BUCKET” were not visible on one bucket. Re-stencil "FIRE
BUCKET" on deficient bucket to satisfaction of Marine
Inspector.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Re-stenciled "FIRE BUCKET" on deficient bucket to satisfaction of Marine
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2019
Resolved
Portable and semi-portable extinguishers must be
inspected and maintained in accordance with NFPA 10.
Debris was found in nozzle to 01 fire extinguisher. Have
extinguisher nozzle maintained as per NFPA 10 and to the
satisfaction of an attending Marine Inspector. Until
serviced and deficiency cleared, have appropriate sized
standby extinguisher on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 28 June 2019
Resolution: Fire extinguisher made satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 May 2019
Resolved
A vessel on a rivers route must carry:three hand red
flare distress signals and three hand orange smoke
distress signals approved in accordance with §160.037 in
subchapter Q of 46 CFR. Hand red flare distress signal
may be substituted for any hand orange smoke distress
signals. Vessel only had 04 hand red flare distress
signals on board. Have satisfactory amount/type of
distress signals on board.
Action required: 10 - Deficiency Rectified
Resolved 30 May 2019
Resolution: Has satisfactory amount/type of distress signals on board.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 30 May 2019
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, upon first being employed and
prior to getting underway for the first time on a particular vessel and at least once every three months,
as to the duties that the crew member is expected to
perform in an emergency. Crew was unaware of location of
port to collision bulkhead for dewatering. Moving
forward drill with all crew on proper dewatering of
collision bulkhead and maintain access so as to not
seize.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 18 September 2019
Resolution: Provided recordeed training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2018
Resolved
A vessel must be provided with bilge pump where the pump
is listed by an independent laboratory as meeting the
requirements in UL 1113. Bilge pump was found to not
meet UL 1113. Please replace with appropriate pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 August 2018
Resolution: O/O replaced with appropriate pump.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 26 June 2018
Resolved
The emergency instructions must be designed to address
the particular equipment, arrangement, and operation of
each individual vessel. Emergency instructions posted
did not follow the actual actions of the ship's crew in
case of a Man Overboard (MOB). Make posted emergency
instructions as to the actual emergency practices of the
vessel and drill procedures of the crew. Make any
changes necessary to express changes in procedure
(tethering/life jacket on Master/not using passengers)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 August 2018
Resolution: Made posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2018
Resolved
Lifejackets must be properly stowed. Two lifejackets (as
required by the vessel's COI) were not properly stowed.
Provide proper stowage of lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2018
Resolution: Provided proper stowage of lifejackets.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 May 2016
Resolved
Provide Consortium contract for 2016 with listing of covered employees.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Contract statement provide on board.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 3 May 2016
Resolved
Provide proof of MIS submission for 2015.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Viewed copy of the 2015 MIS.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 May 2016
Resolved
Provide proof of supervisors / masters completed 1 hr EAP training.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Training completed with signed statements for all crew within vessel's DAPI file.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 3 May 2016
Resolved
Identify Substance Abuse Professional (SAP)with contact information.(49CFR40.289)
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: SAP information provided to each crew member during EAP training as well posted on vessel.
Lifesaving › Lifebuoys › Approval
Issued 3 May 2016
Resolved
Waterlight w/ CRES clip attached around the body of the ring with lanyard 3-6'.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: New water light with lanyard and corrosion resistant clip on board vessel.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 May 2016
Resolved
Mark direction of operation for fuel shut off valves; exercise valves.
Due 3 June 2016
Resolved 21 July 2016
Resolution: Valve painted red, arrow marked IVO and operable.
Documentation › Markings/Placards › Warning Signs
Issued 3 May 2016
Resolved
Post emergency broadcast placard (corrected on spot).
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 May 2016
Resolution: Provided placard which was annotated with vessel number and affixed ivo radio.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2016
Resolved
Provide operable portable lights (corrected on spot).
Due 3 June 2016
Resolved 3 May 2016
Resolution: Operable light provided with an additional spare on charger.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2016
Resolved
Provide chaffing gear for wiring on engine room forward bulkhead.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Looming provided on wiring.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 3 May 2016
Resolved
Provide up-to-date Rules of the Road onboard. (emailed)
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: ROR handbook on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016
Resolved
Provide missing/expired items for first aid kit. (List provided).
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: New first aid kit provided on board with current items; dates marked on inside cover.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 May 2016
Resolved
Replace 1 adult lifejacket. (corrected on spot)
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 May 2016
Resolution: Old jacket destroyed prior to MI's departure with new jacket provided and marked appropriately.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 May 2016
Resolved
Stencil vessel name on life jackets as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 3 May 2016
Resolution: New jacket marked appropriately.
Engineering › Bilge Water Management System › Pump
Issued 3 May 2016
Resolved
Provide bilge pump meeting UL 1113 approval.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 May 2016
Resolved
Provide rubber matting under fire extinguishers.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 21 July 2016
Resolution: Rubber installed on base of mount.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 May 2016
Resolved
Alcohol testing swabs expired, if carried must be current. (removed from vessel)
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Expired testing swabs removed from vessel.