Inspection history · 20
11 February 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8071490
6 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907703
22 January 2024
Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7851357
5 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662843
26 March 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7680367
15 May 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7565242
5 April 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7429041
21 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7416001
21 March 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7416860
4 January 2022
Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7375484
10 September 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7309482
30 March 2021
DAPI Audit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7169984
22 March 2021
Deadweight Survey · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7160494
7 January 2020
Plan Review "T" Boat · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6884130
13 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6683449
23 July 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6488052
1 February 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6346652
4 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6230066
14 March 2017
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6111239
7 April 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5853242
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following:Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Starboard shroud clevis pin at deck level found with crack.
46 CFR 176.802(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 21 February 2025
Resolution: Operator replaced clevis pin in-kind to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 February 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. 02 aft bulkhead penetrations in engine room found not vapor tight.
46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 21 February 2025
Resolution: Operator repaired vapor tight integrity to the satisfaction of the Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] on forward hatch exterior is worn.
46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 21 February 2025
Resolution: Operator replaced label to the satisfaction of the Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; and Coast Guard Light List. The vessel did not have a hard copy of the U.S. Coast Pilot or Coast Guard Light List on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 10 May 2024
Resolution: Vessel rep provided evidence of Coast Pilot and Light List.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The vessel was missing 01 portable lights located at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 10 May 2024
Resolution: Vessel rep provided satisfactory evidence of portable light onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023
Resolved
Owner shall submit for approval to the cognizant OCMI plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: On sailing vessels; masts including integration into the ships structure and rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions and connections of the standing rigging. Vessel's Preventative Maintenance plan was from 2018 and no longer applicable. Crew was completing inspections and basic maintenance. Ensure Preventative Maintenance is created and submitted in accordance with NVIC 02-16.
46 CFR 177.202(b)(12(i)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 15 May 2023
Resolution: Recieved satisfactory PMP.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 April 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Certificate onboard was valid until 2024 however call signs did not match Ship Station license or COI. Renew Radiotelephony Certificate to harmonize call sign.
47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 22 May 2023
Resolution: FCC certificate renewed successfully.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 April 2023
Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure was observed to be approximately 30 psi. Submit proposal to repair/install satisfactory fire pump.
46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 27 April 2023
Resolution: MI researched fire pump requirements and located special note which lowers the length overall of the vessel to less than 65 feet, vessel will continue to have installed fire suppression system, fire buckets and garden hose onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Duty MI notified by vessel operator of loss of steering event while underway.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2022
Resolution: Repairs made. MIs ran operational steering test. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
The selection of crewmembers for random drug testing shall be made by a scientifically valid method, such as a random number table or a computer-based random number generator that is matched with crewmembers' Social Security numbers, payroll identification numbers, or other comparable identifying numbers. Operator hand selects members for chemical testing based on who hasn't been tested recently. Operator must utilize a scientific based method for the selection of random crewmembers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 27 August 2021
Resolution: Operator demonstrated scientifically based method of random selection for enrolled members within the chemical testing program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers [name withheld] program established by employer. Create an EAP program to the satisfaction of the Coast Guard Marine Investigator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 27 August 2021
Resolution: Operator EAP program created and required training and awareness was demonstrated to CG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 March 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material. Port and Starboard buoys did not have retro tape installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 6 April 2021
Resolution: Operator installed retro tape on buoys. See documents tab under deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 March 2021
Resolved
Each collision bulkhead must be fitted with penetrations that are located as high and as far inboard as practicable and have a means to make them watertight. Starboard penetration in collision bulkhead not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 25 March 2021
Resolution: Operator provided pictures of sealed penetrations in bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 July 2018
Resolved
Owner had no life saving maintenance log onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 23 August 2018
Resolution: Owner corrected a comprehensive life saving maintenance log.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2018
Resolved
Vessel had no Coast Pilot [name withheld], or tide tables for the local area.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 23 August 2018
Resolution: Owner provided up to date nav publications.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2018
Resolved
Vessels EPIRB had expired NOAA registration and had an expired hydrostatic release. Vessel is limited to L/B/S's until EPIRB deficiencies are rectified.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 27 July 2018
Resolution: Owner sent pictures of newly installed hydrostatic release and updated NOAA registration on the EPIRB. Vessel is able to operate on limited coastwise as approved by COI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 July 2018
Resolved
Exposed hot wire located on the 01 deck, amidships, port side, in horizontal sliding storage compartment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 27 July 2018
Resolution: Installed correct approved heat shrink tubing.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 23 July 2018
Resolved
Electronic winch controls have damaged rubber covering, exposing electrical components to the conditions. 46 CFR 183.210
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: Owner manufactured rubber covers to protect the electric winch controls from the elements.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 July 2018
Resolved
Child life jacket placard in starboard head had inaccurate count of number of life jackets in space. Sign now says "8" Child PDF's, should be "20"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 24 July 2018
Resolution: Installed placard indicating correct number of child PFD'S.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 23 July 2018
Resolved
Vessel needs to install placards indicating hatches on main deck are emergency exits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 24 July 2018
Resolution: Installed 02 emergency exit placards on main deck.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2018
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space- vessel lacked labels of specific spaces covered by alarms.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2018
Resolved 24 July 2018
Resolution: Labeled each bilge alarm with the correct space.
Sail Rigging › Deck Hardware › Shackles
Issued 1 February 2018
Resolved
Provide Preventative maintenance plan for sail rigging in accordance with NVIC 2-16. 46CFR176.802
Due 1 March 2018
Resolved 7 March 2018
Resolution: Reviewed draft of vessel's PMP.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 August 2017
Resolved
Collision bulkhead has exposed 1/2" pentratration that must be made watertight (see DOCUMENTS tab). 46 CFR 171.085 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 7 August 2017
Resolution: Operator provided proof of satisfactory collision bulkhead repair.