LUCKY STRIKE

LUCKY STRIKE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 28 deficiencies and 4 casualty investigations between 2010 and 2022.

Records from 2010 to 2026. Most recent: inspection, 23 April 2026.

Built
1985
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDA6742
363975
Flag
UNITED STATES
Maury page id
psix-363975

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)39.0 ft × 14.0 ft × 3.7 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builder#1 BOAT MFG INC · KEY WEST, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLITTLE RIVER, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 27 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 22

23 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8352967
7 January 2026 Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8291613
11 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8107945
17 April 2024 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7895427
31 January 2024 Hull Examination · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7858664
7 April 2023 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7664426
27 December 2022 Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7613740
26 April 2022 Administrative Inspection · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7443832
26 April 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7449788
4 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7406032
21 December 2021 Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7371060
26 April 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7182793
25 February 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7146025
20 April 2020 Deficiency Check · Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6941575
13 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6682766
1 February 2019 Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6618196
16 April 2018 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6391033
1 December 2017 Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 6316896
20 March 2017 Internal Structural Exam · Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6107760
6 March 2017 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6099414
17 May 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5875010
4 February 2016 Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5812272

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2026 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Generator fuel filter fitted with a plastic bowl and does not have a flame shield.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 4 May 2026
Resolution: Installed an approved type filter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2026 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard is worn and unreadable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 4 May 2026
Resolution: Replaced with new donning placard
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 April 2026 Resolved
An interconnected detection and alarm system must: Contain an independent power source. Detectors were found with the batteries removed.
Action required: 10 - Deficiency Rectified
Due 23 April 2026
Resolved 23 April 2026
Resolution: Installed batteries and tested.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have an FCC Station License. The operator was unable to provide proof of same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2025
Resolved 22 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 April 2025 Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date charts and publications. The vessel was not provided with a chart, additionally, the Coast Pilot and USCG Light List were not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 22 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2025 Resolved
Each life jacket must be approved in accordance with 46 CFR 160.002., 160.005, or 160.055. The reflective material on (4) life jackets was deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2022 Resolved
At least one ring life buoy must be fitted with a lifeline in accordance with 180.70(c); the existing lifeline is deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 22 March 2022
Resolution: Master replaced line
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 March 2022 Resolved
The marine employer must have a drug program in place in accordance with 46 CFR 16.113; the deckhand has not had pre employment testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 21 March 2022
Resolution: DH is enrolled in company DAPI
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2022 Resolved
A pre engineered fixed gas fire extinguishing system must have a audible and visual alarm at the operating station; the existing alarm is not operational.
Action required: 10 - Deficiency Rectified
Due 21 March 2022
Resolved 8 March 2022
Resolution: Repaired and tested while onboard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 March 2022 Resolved
A vessel of less than 12 meters must be equipped with a sound signaling device; the vessel is not so equipped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 21 March 2022
Resolution: Master procured new handheld horn
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 April 2021 Resolved
The vessel must have issued an FCC Safety Radio Certificate upon completion of an inspection by the FCC Technician; the existing certificate is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 April 2021 Resolved
The vessel must carry a first aid kit, approval number 160.041; the aspirin in the existing kit are expired.
Action required: 10 - Deficiency Rectified
Resolved 26 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2021 Resolved
If the handle for the fuel shutoff valves are located within the machinery space, the handles must be protected/shielded from flames by some non-combustible material; the existing material has deteriorated and bears replacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2020 Resolved
The vessel is required to have three portable fire extinguishers as indicated on the COI; the vessel currently has two fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 May 2019 Resolved
The aft bilge alarm is not operational; repair or replace as needed.
Action required: 10 - Deficiency Rectified
Resolved 15 May 2019
Resolution: Repaired prior to MI's departure.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2019 Resolved
The fixed fire fighting system did not function properly upon initial test and was intermittent on subsequent tests, the system eventually tested satisfactory. The issue is due to corrosion of the wire connections; clean the connection terminals and insure proper operation.
Action required: 10 - Deficiency Rectified
Resolved 15 May 2019
Resolution: Once the sensor wires were making good contact the system tested satisfactorily.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2019 Resolved
The first aid kit does not contain a complete inventory of supplies; provide for missing supplies as needed or replace the kit with an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: The first aid kit is updated IAW CFR.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 May 2019 Resolved
The shielding surrounding the remote fuel shut-off valves is deteriorated; repair or replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: New shielding and insulation has been installed and valves were re-tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019 Resolved
There are dead-end wires in the engine compartment and under the operating station; remove or properly terminate the wires in question.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Dead end wires have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019 Resolved
There are electrical wires under the operating station which are spliced together with wire nuts; remove wire nuts and make connection crimp on type connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Wire nuts have been removed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2019 Resolved
The US Coast Pilot and the USCG Light List are not current, provide the vessel with up-to-date copies of the navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
Resolution: Updated Nav-pubs are now onboard.
Lifesaving › Lifefloat › Painter
Issued 8 March 2017 Resolved
Replace the painter on the life float due to deterioration.
Due 22 March 2017
Resolved 20 March 2017
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2017 Resolved
Provide the vessel with an updated navigation chart.
Due 22 March 2017
Resolved 20 March 2017
Engineering › Bilge Water Management System › Pump
Issued 8 March 2017 Resolved
Replace the existing electric submersible bilge pumps with a "UL" approved type.
Due 22 March 2017
Resolved 20 March 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 May 2016 Resolved
Provide in date alcohol test strip for crew, minimum 2.
Due 17 June 2016
Resolved 31 May 2016
Resolution: Two in date test strips were provided onboard vessel.
Communications › Radio Communications › EPIRB
Issued 17 May 2016 Resolved
Provide NOAA EPIRB registration to match current registration sticker.
Due 17 June 2016
Resolved 19 July 2016
Resolution: Unit received faxed copy of current NOAA EPIRB registration.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 May 2016 Resolved
Provide current excerpts for operating area of the following: Coast Pilot and Light List
Due 17 June 2016
Resolved 31 May 2016
Resolution: Current excerpts were provided onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2016 Resolved
Provide emergency broadcast placard at the operating station.
Due 17 June 2016
Resolved 31 May 2016
Resolution: A laminated vessel specific emergency broadcast placard was onboard.

Casualty record · 4

16 April 2010Routine · role: Involved in a Marine Casualty · activity 3732121
28 June 2011Routine · role: Involved in a Marine Casualty · activity 4069625
16 June 2012Routine · role: Involved in a Marine Casualty · activity 4350779
26 April 2022Routine · role: Involved in a Marine Casualty · activity 7449788
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.