MAURY USCG vessel records Sign in
← All vessels

DELTA PRIDE

DELTA PRIDE is a 1991 freight ship. The Coast Guard has recorded 58 inspections since 1991, most recently in April 2016, along with 40 deficiencies and 1 operational control.

Records from 1991 to 2016. Most recent: inspection, 2 April 2016.

Built
1991
Last inspected
2 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9012381 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
364083
Flag
SOUTH KOREA
—
Maury page id
psix-364083

Inspections, by type

…with no type recorded38
Years with a record 23 calendar years (1991–2016)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25189 - Convention (Subpart B), Gross Ton
25189 - Regulatory (Subpart C or D), Gross Ton
9935 - Convention (Subpart B), Net Ton
9935 - Regulatory (Subpart C or D), Net Ton
38486 - Dead Weight, Ton
46516 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 58

2 April 2016 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5845149
23 October 2014 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5010695
12 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4814530
8 June 2012 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4336462
13 September 2010 PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3848810
12 September 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3847964
14 March 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3433354
9 March 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3430154
8 July 2008 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3261089
23 May 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2938196
8 May 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2643557
7 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2642919
3 August 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2449938
21 January 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2278611
21 January 2005 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2278858
19 January 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277328
18 January 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2276395
16 September 2004 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2197273
2 August 2004 NPV Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153947
15 June 2004 MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2098288
5 January 2004 Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1975705
3 January 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1974452
6 June 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1811823
16 December 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1717254
13 May 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1615468
29 December 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1474423
25 July 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 292266
1 May 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 289744
5 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 286841
1 May 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277472
1 May 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277706
18 November 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274436
18 November 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 434954
19 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 427605
17 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 141110
17 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 427748
24 August 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 419688
10 February 1998 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 413039
30 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 411266
26 December 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 78566
25 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 406192
3 February 1997 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 400148
23 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 46334
19 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 395410
5 February 1996 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 679778
29 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 153439
29 January 1996 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 387254
30 October 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1187023
14 August 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 381778
18 April 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 377711
23 November 1994 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 372593
23 November 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377308
29 March 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166875
28 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1450836
17 November 1993 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 362455
14 September 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 353189
29 January 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 534334
30 July 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 345888

Deficiency record · 40

Engineering › Steering Gear System › Pump
Issued 2 April 2016 Resolved
0936: Each vessel must have a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. The storage tank was found empty during psco's inspection. 74SOLAS(14)II-1/29.12.3
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 2 April 2016
Resolution: Tank was refilled with hydraulic fluid and maintenance issue was addressed by attending class surveyor.
Personnel › Training › Medical Care Provider
Issued 8 June 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2012
Resolution: Role of medical officer was changed from 3rd Officer to 1st Officer on SMS System and approved by Class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 June 2012 Resolved
1499: The machinery & associated piping systems & fittings shall be of a design & construction adequate for the service for which they are intended. The following deficiencies were identified in the ER: Patch on hydraulic valve for ballast, air compressor cooling line leaking, temp probe to M/E air cooler patched & leaking, Eductor line patch, SSDG Cooler lines patch & leaking. SOLAS(97) II-1/26
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2012
Resolution: Class attended vessel and addressed all relevant pipes with associated fittings; upon repair determined to be in satisfactory condition.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 June 2012 Resolved
0999: The fire resistance doors shall be equivalent to that of the division in which they are fitted. The fire doors throughout the house do not close by themselves or latch. SOLAS (97) II-2/47.1
Action required: 705 - Other - as specified
Resolved 5 July 2012
Resolution: The ship’s crew adjusted all doors, and replaced all securing/latching mechanisms, doors working as intended.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 13 September 2010 Resolved
1410-Vessel was unable to change from stop to dead slow astern while in bridge control. Engine was able to achieve dead slow astern when control was given to engine control room . 17 a/b
Due 14 September 2010
Resolved 13 September 2010
Resolution: Received Class report rectifying issue
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 9 March 2009 Resolved
1400- Intermediate shaft bearing is leaking oil. No reports have been sent to the company and the captain was not informed of this. Class must inspect in LA/LB. SOLAS I/11. ISM 9/10. 15 A/C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 14 March 2009
Resolution: Received class report attesting the shaft bearing was found in good order, leak repaired and company was informed. All sat.
Engineering › Thrusters › Tunnel
Issued 9 March 2009 Resolved
1400- Half of the Bow thruster is covered in cement for unknown reason. Class must inspect in LA/LB. 15 A/C
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 14 March 2009
Resolution: Received class report attesting the cement was removed. All sat.
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 9 March 2009 Resolved
1400- Repairs have been made to the forward heater on the emergency generator. Class must inspect in LA/LB. ISM 9/10. 15 A/C
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 14 March 2009
Resolution: Received class report attesting repairs to the Emergency generator were satisfatory.
Engineering › Steering Gear System › Rudder Bearing
Issued 9 March 2009 Resolved
1400-Limit switch on steering gear does not work properly. Only the inside limit switch operates. Class must inspect in LA/LB. ISM 9/10. 15 A/C
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 14 March 2009
Resolution: Received class report attesting the limit switch was repaired and working properly. All Sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 9 March 2009 Resolved
0510- The ventilation located in the forward bosin store which lleads to the bow thruster space is holed. 70 A/B.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2009
Resolution: Received class report attesting holed ventilation replaced with new steel plate. All sat
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2009 Resolved
0371- The medical kit in the Engine Control room was not safe for use. Discussed with the Captain/[name withheld] all kits be checked and outfitted properly. 70 A/B
Due 9 March 2009
Resolved 9 March 2009
Resolution: First Aid kits were checked.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 March 2009 Resolved
0330- The marine sanitation system is not being maintained as per the manufacturer’s requirements. Inspection/check must be carried out as per the manufacturer's requirements and recorded. ILO147. 10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2009
Resolution: Received class report attesting MSD was being maintained according to manufacturers standards. All sat
Lifesaving › Inflatable Liferafts › Container Construction
Issued 2 August 2004 Resolved
Life raft straps that secure container have been removed. This will allow water to leak into the container.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2004
Resolution: Deficiency cleared by local on scene Coast Guard inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 August 2004 Resolved
Two way intake pipe has a patch .
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2004
Resolution: Deficiency cleared by local on scene Coast Guard inspector.
Fire Fighting › Means of Escape › Blocked
Issued 2 August 2004 Resolved
Escape exits are only accessible from inside. The crew intends to modify for enter/exit by using a wing-nut and lock.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2004
Resolution: Deficiency cleared by local on scene Coast Guard inspector.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 2 August 2004 Resolved
EEBD's in engine room are low on air.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2004
Resolution: Deficiency cleared by local on scene Coast Guard inspector.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 June 2004 Resolved
Marine sanitation device has pinhole leak.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2004
Resolution: Crewmembers repaired the leak.
Documentation › Logs/Records › Oil Record Book
Issued 15 June 2004 Resolved
Oil record book entries are improperly entered or are not signed by officers.
Due 15 June 2004
Resolved 15 June 2004
Resolution: Corrected on the spot.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 15 June 2004 Resolved
Embarkation ladder worn and rotting at connection to main deck.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2004
Resolution: Lines on ladders renewed
Lifesaving
Issued 1 May 2001 Resolved
FLAMMABLE LIQUIDS STORED IN THE STEERING FLAT, ENG. ROOM, DECK STORES.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Engineering
Issued 1 May 2001 Resolved
COAT HANGER HOLD BACKS ON MULTIPLE SOUNDING TUBES IN ENGINE ROOM.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Documentation
Issued 1 May 2001 Resolved
SAFTEY EQUIPMENT FORM "E" NOT ON BOARD, NO COPY PROVIDED.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Lifesaving
Issued 1 May 2001 Resolved
FOREWARD LIFERAFT NOT SERVICED WITHIN 19 MONTHS.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Unknown
Issued 1 May 2001 Resolved
FLAME SCREENS ON MULTIPLE VENTS HOLED AND DIRTY.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Electrical
Issued 1 May 2001 Resolved
EMERGENCY GENERATOR FUEL SHUT DOWN CABLE CONDUCT CORRODED NOT PERMITTING PROPER OPERATION OF SHUT DOWN.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Unknown
Issued 1 May 2001 Resolved
VENTILATION IN PAINT LOCKER IS HOLED COMMON TO BOW THRUSTER SPACE AND FORECASTLE.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Documentation
Issued 1 May 2001 Resolved
SOLAS TRAINING MANUAL AVAILABLE TO CREW NOT COMPLETE.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Lifesaving
Issued 1 May 2001 Resolved
PORT LIFEBOAT AFT DAVIT FWD SHEEVE JAMMED.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Navigation
Issued 1 May 2001 Resolved
STEERING GEAR LIMIT SWITCHES DO NOT OPERATE.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Unknown
Issued 1 May 2001 Resolved
POISONOUS COMPRESSED GAS CYLINDER STORED IN STEERING FLAT
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Unknown
Issued 1 May 2001 Resolved
ENGINE ROOM ESCAPE TRUNK LOWER LEVEL LIGHTING EXTINGUISHED.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Lifesaving
Issued 1 May 2001 Resolved
BUNKER STATIONS MISSNG CONTAINMENT CLOSURES FLANGE BOLTS.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Engineering
Issued 1 May 2001 Resolved
MAIN LUBE OIL LINE LEAK AT PLANGE OUT BOARD STB ON MAIN ENGINE.
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Navigation
Issued 25 July 1997 Resolved
The chart 18656 was not up to date.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Engineering
Issued 3 February 1997 Resolved
MAKE PERMANENT REPAIR TO MAIN ENGINE SALT WATER COOLING PIPE WHICH HAD BEENTEMPORARILY REPAIRED. SEE KOREAN REGISTER OF SHIPPING SURVEY REPORT DATE OF04-02-97, REPORT NO. PLD0013-97. ILLC 66 ANNEX I/1.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Navigation
Issued 29 January 1996 Resolved
NOAA CHART 18649 ED.#57, UPDATED TO 24/95. MISSING CORRECTIONS 26 & 30/95. NOAA CHART 18658 ED.#27, UPDATED TO 16/95. MISSING CORRECTIONS 26 & 27/95. NOAA CHART 18656 ED.#50, UPDATED TO 45/94. MISSING CORRECTIONS 48/94 & 26,27,38/95.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Fire Fighting
Issued 23 November 1994 Resolved
Prior to departure from San Francisco Bay, tighten the dripping fire main dressler coupling between No. 4 & 5 cargo hatches.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Lifesaving
Issued 23 November 1994 Resolved
Renew the batteries in the engineroom life preservers water lights.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Engineering
Issued 28 March 1994 Resolved
PRIOR TO DEPARTING SAN FRANCISCO BAY, CALIFORNIA, HAVE VESSEL'S CLASSIFICATION SOCIETY VISIT AND FILE A REPORT TO THE COTP SAN FRANCISCO BAY STATING IF VESSEL IS CONSIDERED FIT FOR INTENDED SERVICE AND ROUTE.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Documentation
Issued 28 March 1994 Resolved
PRIOR TO DEPARTING SAN FRANCISCO BAY, CALIFORNIA, SUBMIT TO THE COGNIZANT COTPAN ACCIDENT FORM CG-2692 FOR LOSS OF MAIN PROPULSION AND GROUNDING INCIDENT ON 27 MARCH 1994.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.