MAURY USCG vessel records Sign in
← All vessels

GLOBAL HEIDI

GLOBAL HEIDI is a 1991 research vessel. The Coast Guard has recorded 59 inspections since 1991, most recently in August 2026, along with 53 deficiencies and 1 operational control.

Records from 1991 to 2026. Most recent: inspection, 5 August 2026.

Built
1991
Last inspected
5 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8977807 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF4766
364141
Flag
UNITED STATES
367455610, 368475070
Maury page id
psix-364141

Inspections, by type

…with no type recorded11
Years with a record 31 calendar years (1991–2026)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)147.3 ft × 30.0 ft × 10.5 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)147.3 ft × 30.0 ft × 10.5 ft
ITC tonnagegross 285 / net 85
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
285 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
85 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9878MMSI 368475070 · active · compulsorily equipped · granted 20 May 2026, expires 20 May 2036
WDF4766MMSI 367455610 · active · compulsorily equipped · granted 2 June 2020, expires 5 June 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDB7812MMSI 366511000 · cancelled · compulsorily equipped · granted 15 May 2004, cancelled 4 March 2010 · licensed under a name not among this hull’s recorded names (not shown)
WBB5795MMSI 366511000 · cancelled · compulsorily equipped · granted 29 October 1998, cancelled 25 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

5 August 2026 Vessel Attendance · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8456894
21 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8022100
22 August 2023 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7790499
9 August 2023 Deficiency Check · Hull Examination · In-Service Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7764270
8 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7683983
4 January 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375300
20 July 2021 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7261500
13 July 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7255224
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108430
16 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7076131
15 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6750438
28 June 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6728401
15 August 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6531464
17 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482967
13 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6443480
17 September 2017 Administrative Inspection · Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6268384
1 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6162100
24 May 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6154597
8 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6084671
12 July 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5938609
22 January 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3932536
8 January 2011 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 3923826
9 September 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3845565
8 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3448863
13 March 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3163864
6 February 2007 Re-Inspection · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2885067
14 September 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2778101
16 November 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2536130
14 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2334031
28 January 2005 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2282457
3 November 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2233731
25 August 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1888774
24 March 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1761868
22 August 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1664816
13 August 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466798
20 March 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379337
22 August 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433715
25 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410156
28 April 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460288
18 August 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469202
20 August 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442617
3 April 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418147
16 January 1997 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1101427
9 January 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 134137
29 August 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445116
16 January 1996 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759740
15 December 1995 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 196320
6 September 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374391
28 March 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405683
6 September 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422412
24 September 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 516495
22 September 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 661583
20 September 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 169098
20 September 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 225344
7 September 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403677
17 March 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410781
9 September 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393869
27 September 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265583
17 September 1991 Initial Construction-Excluding Oversight · Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244818

Deficiency record · 53

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2024 Resolved
Each buoyant apparatus shall be fitted with a life line and shall be equipped with a water light and painter. Two (02) water lights connected to life floats were non-functioning.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2024
Resolved 21 October 2024
Resolution: Batteries replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Machinery Guards on Air compressors are wasted and not secure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Guards replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port #2 Engine jacket water pipe leaking. #2 Port Engine junction box was damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Items corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Crack present in galley space lighting fixture. Lacked inline junction box leading to the stern light and two (02) deck lights. #2 Port Engine junction box was damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Light replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 August 2023 Resolved
Oceans T boats on warm water route required 100% life float. 02 life floats were found to have wasted life lines as the pennants were frayed and able to be torn from the life line. Vessel is restricted to 72 passengers until the life floats are repaired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2024
Resolution: Pennants were in good condition at time of this inspection. This appeared to be an old def that was not cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2023 Resolved
Gears, couplings, flywheels, and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Guards were not installed on rotating machinery belts on all 6 mains.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 31 August 2023
Resolution: Witnessed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2023 Resolved
Protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe. #6 main exhaust and all main engine turbos had no insulation/ protection installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 12 September 2023
Resolution: Witnessed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Lifefloat lifeline and pendants must be as furnished by the manufacturer with the approved life float. Lifeline and pendants were dry rotted from sun exposure. Passenger count reduced by 36 to 60 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Lifefloat pendants and lifelines replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Lifefloat painter must be stowed so that it may run out freely; painter was not installed to allow the stbd side lifefloats to float free.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: Spliced painter so that life floats could float free.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 January 2022 Resolved
Lifefloat light must be as approved under approval series 161.010; battery in port side waterlight for lifefloat was dead.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: Replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Ring life buoy on a vessel must be approved in accordance with 160.050; grab line was missing beckets, so line was slack and loose on pilot house ringbuoy
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Beckets replaced, picture evidence received.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material; stbd side ring life buoy retro tape was peeling, needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Retro tape replaced, picture evidence received.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 January 2022 Resolved
Engine exhaust piping must be properly supported by non-combustible hangars or blocks; #3 engine exhaust piping, #5 MDE piping were each missing bolts
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Received photo evidence of all hanger bolts in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2020 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station." Multiple jacket water discharge temperature gages were found to be inoperable. Vessel shall fix or acquire temperature gauges and clear discrepancy with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2020 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with §181.450." Two modular smoke detectors found to be inoperable. Smoke detector operability shall be demonstrated to marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 21 October 2020
Resolution: cleared to satisfaction of MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2020 Resolved
Where pressure-indicating gauges are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. Both of the A/C receivers pressure gauges were inoperable in their ability to determine the pressure. Fix or acquire pressure gauges and demonstrate operability to marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satisfaction of MI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2020 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel." MI noted the following electrical hazards; 1. Electrical connection made outside junction box for port A/C compressor. 2. Both port & starboard side MDE starter batteries were exposed and not in protective boxes/covers. 3. Starboard A/C cutoff switch was exposed. 4. Overhead light was exposed in engine room 5. High voltage dead end wires exposed in engine room from previous fire damage and system replacement. 6. Electrical control box mount missing for FWD gen. All items above shall addressed and corrected by the master within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2020 Resolved
Switchboards shall be fitted with driphoods and non-conducting hand rails. Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. Inadequate electric matting found in from of switchboard. Matting must be ASTM Type II. Vessel shall correct deficiency and clear the deficiency with the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2020 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. Bulkhead penetration was open on the FWD bulkhead in aux space. Clear deficiency with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2020 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel in suitable for the vessel and its operation and that the auxiliary machinery is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. No. 3 main engine lube oil plug was broken and the port generator jacket water head tank hoses were wasted. Port generator Murphy switch needs to be reinstalled. These deficiencies shall be corrected and cleared with the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satifaction of MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2020 Resolved
The Rules concerning shapes shall be complied with by day. Vessel did not have the necessary day shapes to comply. Obtain two black day shape balls and clear deficiency with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satifaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 July 2019 Resolved
Batteries in water-lights on life-rings and life-floats were expired as of August 2016. VSL replaced batteries during the inspection. 46 CFR 180.70(d) / 180.175
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 16 July 2019
Resolution: Batteries in waterlights replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2019 Resolved
Machinery Guards on MDE 4 and 6 are missing. Guards shall be in place while machinery is running for safety of crew. Install guards in accordance with manufacture instructions. 46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: Machinery Guards on MDE 4 and 6 installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2019 Resolved
AFFF is expired. Product has a shelf life for 20 years. Replace Bottles with non expired product. 49 CFR 176.315
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: New AFFF Bottles purchased and onboard the VSL
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2019 Resolved
Shaft seals on # 3 and # 6 MDE are leaking. Secure leak on shaft seals. 46 CFR 179.350
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: Gasket replaced on shafts, securing leak.
Documentation › Certificates/Documents › Permit, Other
Issued 17 September 2017 Resolved
Have space certified safe for worker by a certified Marine Chemist and do not to clean or move anything until inspected by a USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2017
Resolved 13 June 2018
Resolution: Vessel no longer requires cert
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 September 2017 Resolved
Submit Repair to local OCMI for approval and make repairs to the satisfaction attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2017
Resolved 13 June 2018
Resolution: Vessel submitted approved plans
Lifesaving › Lifefloat › Painter
Issued 17 September 2017 Resolved
During preparations for abandon ship damage, to a life float and the line connecting 1 of the floats parted.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2018
Resolution: Vessel has new painter for life floats on board
Lifesaving › Lifefloat › Paddle
Issued 17 September 2017 Resolved
Replace 2 paddles lost during preparations for abandon ship.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2018
Resolution: Vessel has new paddles on board
Lifesaving › Line-Throwing Appliances › Water Resistant Casing
Issued 8 February 2017 Resolved
Provide boathooks, ships medicien chest and medical aid at sea book, and line throwing gun blank cartridges IAW 33CFR143.405 Prior to operation as stand by vessel.
Action required: 705 - Other - as specified
Resolved 7 March 2017
Resolution: Vessel provided photos of equipment aboard vessel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 12 July 2016 Resolved
#1 and #6 Shaft seals are leaking raw water excessively, approximately 1 gallon per hour each.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 14 July 2016
Resolution: Shaft seals were properly adjusted to stop leaking.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 9 September 2010 Resolved
Port outboard MDE fuel supply valve leaking. Repair or renew supply valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2010
Resolution: Valve repaired and no leaks present
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 9 September 2010 Resolved
Backing nuts not provided on shaft collars. Provide backing nuts.
Due 9 October 2010
Resolved 10 September 2010
Resolution: Vsl rep replaced all bolts and added backing nuts.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 9 September 2010 Resolved
Interlock bar was removed from switchboard panel. Provide properly installed interlock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2010
Resolution: Interlock properly installed and operable
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 September 2010 Resolved
Port Fuel Return Valve leaking. Repair or replace.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2010
Resolution: Fuel leak repaired
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 9 September 2010 Resolved
Properly outfit all fuel vents with flame screens.
Condition: Improper Installation
Due 9 October 2010
Resolved 10 September 2010
Resolution: All fuel vents properly outfitted with Flame screens
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 September 2010 Resolved
Vsl not properly outfitted with Fuel transfer procedures and fuel manifold diagram. Provide transfer procedures and diagram for vsl and diagram at transfer station.
Condition: Invalid
Due 9 October 2010
Resolved 10 September 2010
Resolution: Vsl outfitted with trasfer procedures and fuel diagram.
Construction/Loadline › Hull › Side Shell
Issued 13 March 2008 Resolved
6'' fractured on STBD side IWO midship.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2008
Resolution: fracture drill stopped, gouge and weld both sides of side shell
Construction/Loadline › Hull › Bracket
Issued 13 March 2008 Resolved
Several fractures in transom steering compartment
Condition: Damaged By Earlier Event
Due 27 March 2008
Resolved 13 March 2008
Resolution: Fractures gouged and welded
Construction/Loadline › Structures › Deck Plating
Issued 13 March 2008 Resolved
Fracture IWO #5 STBD MDE mount.
Condition: Unknown
Due 27 March 2008
Resolved 13 March 2008
Resolution: MDE mount gouged and welded
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 March 2008 Resolved
Updated tables, light list not present.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2008
Resolution: Vessel supplied with up to date charts and pubs
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 March 2008 Resolved
First aid kit had several expired medicines
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 March 2008
Resolution: First aid kit re-supplied with up to date medicines
Stability › Watertight Integrity › General
Issued 14 September 2006 Resolved
Renew OVBD discharge handle for washing machine.
Due 14 October 2006
Resolved 14 September 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 September 2006 Resolved
Resucure water fountain in main passage way.
Due 14 October 2006
Resolved 14 September 2006
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 14 September 2006 Resolved
Clean all generator armatures.
Due 14 October 2006
Resolved 14 September 2006
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 14 September 2006 Resolved
Install flame screens on Port & stbd engine lube tanks.
Due 14 October 2006
Resolved 14 September 2006
Documentation › Markings/Placards › Warning Signs
Issued 14 September 2006 Resolved
Label rudder room watertight door
Due 14 October 2006
Resolved 14 September 2006
Stability › Watertight Integrity › General
Issued 14 September 2006 Resolved
Verify adjustments to all loose watertight doors
Due 14 October 2006
Resolved 14 September 2006
Engineering › Compressed Air System (control) › Valve
Issued 16 November 2005 Resolved
The relief valve on the #1 air receiver failed to lift at the designated pressure of 150 psi.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2005
Resolution: Further testing revealed that the pressure gauge on the #1 air receiver was off by over 20-psi. The gauge was changed out and the relief valve was re-tested and lifted at 150-psi.
Lifesaving › Buoyant Apparatus
Issued 22 August 2002 Resolved
RENEW FOUR LIFEFLOAT PADDLES. LEGACY COMPONENT DESC: PADDLES
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 22 August 2002
Lifesaving › Buoyant Apparatus
Issued 22 August 2002 Resolved
RENEW ONE LIFEFLOAT FLOAT LIGHT. LEGACY COMPONENT DESC: FLOAT LIGHT
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 22 August 2002
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2002 Resolved
WELD CRACK IN PORT MACHINERY ROOM IWO BIT.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 22 August 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 August 2002 Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON MAIN ENGINES AS DISCUSSED. LEGACY COMPONENT DESC: FLEXIBLE HOSES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2002
Resolved 22 August 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.