GLOBAL HEIDI

GLOBAL HEIDI is a 1991 research vessel. The Coast Guard has recorded 20 inspections since 2016, most recently in August 2026, along with 31 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 5 August 2026.

Built
1991
Last inspected
5 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8977807
WDF4766
364141
Flag
UNITED STATES
Maury page id
psix-364141

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)147.3 ft × 30.0 ft × 10.5 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)147.3 ft × 30.0 ft × 10.5 ft
ITC tonnagegross 285 / net 85
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
285 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
85 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

5 August 2026 Vessel Attendance · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8456894
21 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8022100
22 August 2023 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7790499
9 August 2023 Deficiency Check · Hull Examination · In-Service Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7764270
8 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7683983
4 January 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375300
20 July 2021 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7261500
13 July 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7255224
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108430
16 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7076131
15 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6750438
28 June 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6728401
15 August 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6531464
17 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482967
13 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6443480
17 September 2017 Administrative Inspection · Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6268384
1 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6162100
24 May 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6154597
8 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6084671
12 July 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5938609

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2024 Resolved
Each buoyant apparatus shall be fitted with a life line and shall be equipped with a water light and painter. Two (02) water lights connected to life floats were non-functioning.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2024
Resolved 21 October 2024
Resolution: Batteries replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Machinery Guards on Air compressors are wasted and not secure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Guards replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port #2 Engine jacket water pipe leaking. #2 Port Engine junction box was damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Items corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Crack present in galley space lighting fixture. Lacked inline junction box leading to the stern light and two (02) deck lights. #2 Port Engine junction box was damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 7 November 2024
Resolution: Light replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 August 2023 Resolved
Oceans T boats on warm water route required 100% life float. 02 life floats were found to have wasted life lines as the pennants were frayed and able to be torn from the life line. Vessel is restricted to 72 passengers until the life floats are repaired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2024
Resolution: Pennants were in good condition at time of this inspection. This appeared to be an old def that was not cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2023 Resolved
Gears, couplings, flywheels, and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Guards were not installed on rotating machinery belts on all 6 mains.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 31 August 2023
Resolution: Witnessed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2023 Resolved
Protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe. #6 main exhaust and all main engine turbos had no insulation/ protection installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 12 September 2023
Resolution: Witnessed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Lifefloat lifeline and pendants must be as furnished by the manufacturer with the approved life float. Lifeline and pendants were dry rotted from sun exposure. Passenger count reduced by 36 to 60 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Lifefloat pendants and lifelines replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Lifefloat painter must be stowed so that it may run out freely; painter was not installed to allow the stbd side lifefloats to float free.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: Spliced painter so that life floats could float free.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 January 2022 Resolved
Lifefloat light must be as approved under approval series 161.010; battery in port side waterlight for lifefloat was dead.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 January 2022
Resolution: Replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Ring life buoy on a vessel must be approved in accordance with 160.050; grab line was missing beckets, so line was slack and loose on pilot house ringbuoy
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Beckets replaced, picture evidence received.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material; stbd side ring life buoy retro tape was peeling, needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Retro tape replaced, picture evidence received.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 January 2022 Resolved
Engine exhaust piping must be properly supported by non-combustible hangars or blocks; #3 engine exhaust piping, #5 MDE piping were each missing bolts
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
Resolution: Received photo evidence of all hanger bolts in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2020 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station." Multiple jacket water discharge temperature gages were found to be inoperable. Vessel shall fix or acquire temperature gauges and clear discrepancy with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2020 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with §181.450." Two modular smoke detectors found to be inoperable. Smoke detector operability shall be demonstrated to marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 21 October 2020
Resolution: cleared to satisfaction of MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2020 Resolved
Where pressure-indicating gauges are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. Both of the A/C receivers pressure gauges were inoperable in their ability to determine the pressure. Fix or acquire pressure gauges and demonstrate operability to marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satisfaction of MI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2020 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel." MI noted the following electrical hazards; 1. Electrical connection made outside junction box for port A/C compressor. 2. Both port & starboard side MDE starter batteries were exposed and not in protective boxes/covers. 3. Starboard A/C cutoff switch was exposed. 4. Overhead light was exposed in engine room 5. High voltage dead end wires exposed in engine room from previous fire damage and system replacement. 6. Electrical control box mount missing for FWD gen. All items above shall addressed and corrected by the master within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2020 Resolved
Switchboards shall be fitted with driphoods and non-conducting hand rails. Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. Inadequate electric matting found in from of switchboard. Matting must be ASTM Type II. Vessel shall correct deficiency and clear the deficiency with the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2020 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. Bulkhead penetration was open on the FWD bulkhead in aux space. Clear deficiency with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 1 November 2020
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2020 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel in suitable for the vessel and its operation and that the auxiliary machinery is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. No. 3 main engine lube oil plug was broken and the port generator jacket water head tank hoses were wasted. Port generator Murphy switch needs to be reinstalled. These deficiencies shall be corrected and cleared with the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satifaction of MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2020 Resolved
The Rules concerning shapes shall be complied with by day. Vessel did not have the necessary day shapes to comply. Obtain two black day shape balls and clear deficiency with marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 30 October 2020
Resolution: Cleared to satifaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 July 2019 Resolved
Batteries in water-lights on life-rings and life-floats were expired as of August 2016. VSL replaced batteries during the inspection. 46 CFR 180.70(d) / 180.175
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 16 July 2019
Resolution: Batteries in waterlights replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2019 Resolved
Machinery Guards on MDE 4 and 6 are missing. Guards shall be in place while machinery is running for safety of crew. Install guards in accordance with manufacture instructions. 46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: Machinery Guards on MDE 4 and 6 installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2019 Resolved
AFFF is expired. Product has a shelf life for 20 years. Replace Bottles with non expired product. 49 CFR 176.315
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: New AFFF Bottles purchased and onboard the VSL
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2019 Resolved
Shaft seals on # 3 and # 6 MDE are leaking. Secure leak on shaft seals. 46 CFR 179.350
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 13 August 2019
Resolution: Gasket replaced on shafts, securing leak.
Documentation › Certificates/Documents › Permit, Other
Issued 17 September 2017 Resolved
Have space certified safe for worker by a certified Marine Chemist and do not to clean or move anything until inspected by a USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2017
Resolved 13 June 2018
Resolution: Vessel no longer requires cert
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 September 2017 Resolved
Submit Repair to local OCMI for approval and make repairs to the satisfaction attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2017
Resolved 13 June 2018
Resolution: Vessel submitted approved plans
Lifesaving › Lifefloat › Painter
Issued 17 September 2017 Resolved
During preparations for abandon ship damage, to a life float and the line connecting 1 of the floats parted.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2018
Resolution: Vessel has new painter for life floats on board
Lifesaving › Lifefloat › Paddle
Issued 17 September 2017 Resolved
Replace 2 paddles lost during preparations for abandon ship.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2018
Resolution: Vessel has new paddles on board
Lifesaving › Line-Throwing Appliances › Water Resistant Casing
Issued 8 February 2017 Resolved
Provide boathooks, ships medicien chest and medical aid at sea book, and line throwing gun blank cartridges IAW 33CFR143.405 Prior to operation as stand by vessel.
Action required: 705 - Other - as specified
Resolved 7 March 2017
Resolution: Vessel provided photos of equipment aboard vessel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 12 July 2016 Resolved
#1 and #6 Shaft seals are leaking raw water excessively, approximately 1 gallon per hour each.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 14 July 2016
Resolution: Shaft seals were properly adjusted to stop leaking.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.