Records from 2000 to 2012. Most recent: operational control imposed, 3 January 2012.
Inspection history · 10
3 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4217256
1 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4217467
17 August 2011
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4118483
5 July 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2986623
15 May 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2931253
13 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2929047
4 January 2007
ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2850227
3 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2849614
18 September 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 822850
12 September 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282042
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 3 January 2012
Resolved
03 Jan 2012- Vessel experienced a loss of rudder angle indicator while attemtping to transit outbound Port Of Houston. Prior to departure vessel must submit proper documentation form the certificate issuing authority atttesting to the repair and proper operation of the rudder angle indicators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2012
Resolution: Vessel submitted documentation from class stating rudder angle indicator is operational.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 17 August 2011
Resolved
IGC 83 13.6.6
Did not have span gas on board and was not able to be tested.
Due 23 September 2011
Resolved 30 August 2011
Resolution: Received class report.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 17 August 2011
Resolved
IGC 83 5.2.11
Vessel's #1 Starboard tank top bypass valve was found leaking vapor due to a crack at the valve stem base.
Due 23 September 2011
Resolved 24 August 2011
Resolution: Vessel submitted class report stating that the defective valve has been removed and properly secured and blanked off from the system. Condition of class issued until valve is replaced.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 August 2011
Resolved
74 SOLAS REG. 41.8.12
All 25 lifeboat food rations were not in air-tight packaging.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2011
Resolved 24 August 2011
Resolution: Vessel submitted shipping reciept for 25 new pieces of 10,000KJ life boat food rations.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 January 2007
Resolved
Earth detection system on 220 v distribution panel inoperable.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2007
Resolution: Received tech report attesting to repairs and proper operation of the 220v earth detection
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2007
Resolved
Due to inability to test 220 V electrical system for grounds, vessel must ensure 220 v is in compliance with safety construction certificate.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2007
Resolution: Received class report attesting to repairs and the proper operation of the 220v ground detection system
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 January 2007
Resolved
Class "A" fire door to engine room does not self close and latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2007
Resolved 15 May 2007
Resolution: Recieved a survey statement from class attesting to the repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2007
Resolved
Explosion proof light fixtures located in motor room and airlock are cracked. IGC 10.2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2007
Resolution: Received class report attesting to repairs of the explosion proof lighting glass.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 4 January 2007
Resolved
Vessel must ensure safety relief valve settings for deck cargo tanks are set in accordance with Sub "O".
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2007
Resolution: Received Class report stating that the "deck tanks are not for loading cargo. They have no discharge lines or pumps to discharge them. They are for loading cooling down cargo before loading cargo tanks."
Deck/Cargo
Issued 12 September 2000
Resolved
AIR LOCK DOOR INOPERABLE - IGC 3.6.2
Condition: Unknown
Due 19 September 2000
Resolved 18 September 2000