Records from 2016 to 2023. Most recent: inspection, 28 February 2023.
Documentation record
Registered dimensions (L × B × D)33.8 ft × 12.3 ft × 6.0 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJUPITER, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
28 February 2023
Administrative Inspection · Examination of Repairs · Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7646100
16 December 2020
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7117790
9 December 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6870234
8 October 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6830375
3 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6827676
8 July 2019
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6741747
28 November 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6588110
5 October 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6554646
29 June 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6190911
30 September 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6025714
3 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5808737
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019
Resolved
Rudder post assemble found wasted and securing bolts for housing found snapped at heads. Entire assembly to be renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: New support installed and bolted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019
Resolved
Sea valve for MSD raw water intake found frozen in the open condition and unable to be closed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 27 July 2019
Resolution: Renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2019
Resolved
Wiring thru out vessel found in disarray with many improperly spliced connections, dead end wires, and improper securing. Vessel in need of rewiring or extensive electrical work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 27 July 2019
Resolution: Vessel rewired in-kind, except wiring for the livewell/tank. Original wiring found to be not approved type.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 July 2019
Resolved
High water alarm in fwd compartment found disconnected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: New panel installed and re-wired. Tested each compartment, found sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 July 2019
No resolution recorded
Wood rot of plywood decking and crossmembers found beneath access hatch to lazarette. Long term proposal to adddress required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2019
Resolved
Flare box found full of water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 27 July 2019
Resolution: New container purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2019
Resolved
Bracket for fwd fire extinguisher found wasted and in need of replacement
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 27 July 2019
Resolution: New extinguisher purchased w/ bracket.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2019
Resolved
Coaming around engine compartment hatch found soft and in need of repair on starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 27 July 2019
Resolution: Repair found sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2019
Resolved
Exhaust lagging on main engine fwd of raw water injection point found wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: New lagging installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 July 2019
Resolved
Aft deck hatch found not watertight and missing retention lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: Gasket cleaned and adjusted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019
Resolved
Auxiliary means of steering (tiller) found wasted and broken.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: New tiller manufactured
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 8 July 2019
Resolved
Overboard discharge valve for type III MSD found not properly secured closed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 26 July 2019
Resolution: Valve closed and handle removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2018
No resolution recorded
Permanently repair raw water cooling leak on intake piping aft part of engine above transmission.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018 — due date passed with no resolution recorded
Resolution: extended requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 October 2018
Resolved
Remvoe or properly terminate dead end wires thru out vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2018
Resolved 27 November 2018
Documentation › Markings/Placards › Oil Discharge Placard
Issued 30 September 2016
Resolved
Provide Oil / MARPOL placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 19 October 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 30 September 2016
Resolved
Provide current Credential for master.
Condition: Improper/Lack of Maintenance
Due 30 October 2016
Resolved 19 October 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 30 September 2016
Resolved
Provide current list of all employees covered in drug testing program.
Condition: Improper/Lack of Maintenance
Due 3 October 2016
Resolved 19 October 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 September 2016
Resolved
Provide ability to list all persons onboard when vessel is underway.
Condition: Improper/Lack of Maintenance
Due 3 October 2016
Resolved 19 October 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 September 2016
Resolved
Prove proper operation of anchor light.
Condition: Improper/Lack of Maintenance
Due 30 October 2016
Resolved 19 October 2016
Lifesaving › Lifefloat › Serviceable
Issued 30 September 2016
Resolved
Provide serviceable lifefloat with floating water light prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Due 30 October 2016
Resolved 19 October 2016
Lifesaving › Lifefloat › Lifeline
Issued 30 September 2016
Resolved
Provide floating line for life float light.
Condition: Improper/Lack of Maintenance
Due 3 October 2016
Resolved 19 October 2016
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 September 2016
Resolved
Provide current copy of Light List and NAVRULES.
Condition: Improper/Lack of Maintenance
Due 30 October 2016
Resolved 19 October 2016