Documentation record
Registered dimensions (L × B × D)36.0 ft × 16.0 ft × 5.3 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUENEME BOAT WORKS · PORT HUENEME, CA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 13 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
16 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8375903
22 May 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8131873
20 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7938931
18 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690994
17 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7479592
30 September 2021
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7323852
15 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225911
29 June 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6990893
19 September 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6816206
4 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6702635
9 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6410043
29 March 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6113890
15 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908543
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2026
Resolved
Each lifejacket must be approved under approval series in subpart 160.055 in part 160 of this chapter. The vinyl dip coating of 44 lifejackets were cracked and foam beginning to separate, exposing buoyant material to the environment. Vessel is not to carry passengers until lifejackets have approved repair or are replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2026
Resolved 18 June 2026
Resolution: Vessel replaced 44 lifejackets. Inspected by MI at the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2026
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with 160.050 in subchapter Q of this chapter.All exposed materials must be resistant to oil or oil products, salt water and anticipated weather conditions encountered at sea. The vinyl coating on the life ring had cracks, exposing buoyant materials to the environment. Vessel is not to carry passengers until ring life buoy has approved repair or is replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2026
Resolved 18 June 2026
Resolution: Vessel received a new ring life buoy. Inspected by MI at the vessel
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2026
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. The portable fire extinguishers for the accommodation space was found undercharged. Vessel is not to carry passengers until fire extinguisher has been recharged or is replaced.
46 CFR 181.30-5
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2026
Resolved 18 June 2026
Resolution: Vessel received a new portable fire extinguisher. Inspected by MI at the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication;Coast Guard Light List...
MI observed outdated copies of the aforementioned publications, o/o is to ensure these items are updated and available on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 17 June 2025
Resolution: recieved pictures of updated charts
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
MI observed expired and insufficient quantities of items. O/o is to ensure the first aid kit is replenished and meets the inventory requirements per ISO 18813.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 17 June 2025
Resolution: recieved pictures of updated first aid kit
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 May 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of ...fixed gas fire extinguishing system to check for excessive corrosion and general condition.
Crew stated they did not know how to test fixed "fireboy" fire extinguishing system in engine space and were unable to test during the inspection. The annual servicing report also stated the indicator alarm "failed".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 17 June 2025
Resolution: witnessed test and recieved video attesting to proper operation of the fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2019
Resolved
Bilge line for electrical submersible pump has a leak. A flexible tube or hose may be used, but must be of good quality and substantial construction. Replace bilge hose. 46 CFR 182.520 (f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 17 June 2019
Resolution: Installed new bilge pipe
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2019
Resolved
Retroreflective tape on adult lifejackets worn. Each lifejacket must be marked with Type 1 retroreflective material. Replace all worn retroreflective tape on lifejackets. 46 CFR 185.604 (h).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 17 June 2019
Resolution: Replaced retroreflective tape on lifejackets
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Alcohol test strips expired. Alcohol testing of each individual must be conducted within two hours of when the SMI occured. Replace with new alcohol test strips. 46 CFR 4.06.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 17 June 2019
Resolution: Replaced expired alcohol testing strips with new ones.