CTC9102 is a 1991 freight barge. The Coast Guard has recorded 24 inspections since 1991, most recently in January 2010, along with 6 deficiencies and 1 operational control.
Records from 1991 to 2010. Most recent: inspection, 13 January 2010.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)195.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 687 / net 687
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARUTHERSVILLE SHIPYARD · CARUTHERSVILLE, MO, UNITED STATES · built 1991
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it687 - Simplified, Gross Ton 687 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 24
13 January 2010COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661894
15 May 2008Periodic Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3204921
20 July 2007Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2999528
1 August 2006Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2727465
30 June 2006Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2695311
16 June 2005COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2391202
29 July 2004Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2149217
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 14 January 2010
Resolution: USCG Marine Inspector reviewed photos of an acceptable new steel insert (steel plate dimensions 18 in x 18 in x 3/8in) that replaced the 1/2 inch hole IWO No.1 port tank trunk.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 June 2004Resolved
COI amendment with updated ISE, CTIE and DD dates is missing. Provide COI amendment.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 July 2004
Resolution: COI amendment was issued to the vessel. All sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 June 2004Resolved
Centerline bulkhead in open hopper barge has a 5' X 1' hole and 6 hole ranging from 18" X 12" and smaller. Replace centerline bulkhead before any cargo operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 July 2004
Deck/Cargo
Issued 7 June 2001Resolved
Clean cargo tank to inspect damage found during CTI & ISE.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Documentation
Issued 19 July 1993Resolved
PROVIDE VALID SHORE PROTECTION ACT PERMIT FOR THIS OIL-FIELD WASTE BARGE AND DISPLAY VESSEL NUMBER PER 33 CFR 151.1024.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Documentation
Issued 19 July 1991Resolved
PROVIDE PROOF OF CERTIFICATE OF FINANCIAL RESPONSIBILITY FOR THIS VESSEL PRIOR TO PLACING IT INTO OPERATION. TO BE COMPLETED TO THE SATISFACTION OFTHE COGNIZANT OCMI IN NO CASE LATER THAN THE ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.