PRINCE OF WALES

PRINCE OF WALES is a 2001 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 2001, most recently in July 2026, along with 49 deficiencies, 2 operational controls and 11 casualty investigations between 2002 and 2020.

Records from 2001 to 2026. Most recent: inspection, 7 July 2026.

Built
2001
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968351 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG2845
Flag
UNITED STATES
369062000 (licence lapsed)
Maury page id
psix-36456

Inspections, by type

…with no type recorded8
Years with a record 25 calendar years (2001–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)172.5 ft × 52.8 ft × 17.4 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)172.5 ft × 52.8 ft × 17.4 ft
ITC tonnagegross 2,309 / net 1,083
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES, WA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOLLIS, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
2309 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
1083 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA6378MMSI 369062000 · expired · compulsorily equipped · granted 30 November 2001, cancelled 4 February 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

7 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8431880
11 March 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8323274
14 January 2026 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8296928
24 November 2025 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8274095
18 August 2025 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8212756
26 June 2025 Security Breach · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8168371
8 April 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8106828
8 April 2025 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8110254
16 September 2024 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8003521
19 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7884527
11 January 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7857993
3 July 2023 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7735097
22 May 2023 Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7694386
20 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7654384
2 December 2022 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7603404
28 November 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7600685
4 February 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7390891
12 January 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7379557
28 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7209085
1 April 2021 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7167619
23 March 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7161430
22 May 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6959956
22 May 2020 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6965812
25 March 2020 Administrative Inspection · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6931607
3 February 2020 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6902429
20 November 2019 In-Service Inspection · Administrative Inspection · Plan Review (Other than "T") · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6859556
24 October 2019 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6841151
9 April 2019 In-Service Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6660025
5 February 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6621339
15 January 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6610711
13 July 2018 Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6478020
13 July 2018 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6481806
24 June 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6468500
10 April 2018 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6389668
21 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6358752
10 January 2018 In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6336628
25 April 2017 COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6137613
24 March 2017 In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6112306
31 March 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5975343
16 November 2015 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5764518
30 October 2015 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5756552
6 June 2014 In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4909815
29 May 2014 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4873813
6 July 2012 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4370231
15 May 2012 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4312236
25 February 2011 Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3952397
13 January 2011 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3926173
1 December 2010 Construction Oversight
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3902109
16 January 2010 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3665992
12 January 2010 In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3662962
9 July 2009 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3529019
20 April 2009 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3456927
16 April 2008 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3185384
7 December 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3111434
18 October 2007 Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3083161
23 June 2007 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2984432
8 May 2007 COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2925149
29 March 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2897930
9 January 2007 Hull Examination · Internal Structural Exam · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2853156
20 September 2006 Liferaft Servicing
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2782981
4 May 2006 Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2644201
20 January 2006 Annual Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2570355
6 January 2006 Hull Examination · Internal Structural Exam
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2563568
13 September 2005 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2615917
19 January 2005 Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2277239
19 December 2004 Deficiency Check · Examination of Repairs
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2265268
18 December 2004 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2265222
15 November 2004 Periodic Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2252198
24 August 2004 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2176277
14 July 2004 MTSA Verification
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2132711
9 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2021441
23 February 2004 Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2011821
6 January 2004 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1988995
25 September 2003 Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1913114
7 February 2003 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1763946
26 November 2002 Administrative Inspection
Administrative · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1711325
7 November 2002 In-Service Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1713928
4 September 2002 Damage Survey
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1670892
26 June 2002 COI Inspection · Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1637363
28 January 2002 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1487007
15 January 2002 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1485739
26 December 2001 Hull Examination · COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1482688

Deficiency record · 49

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 April 2025 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Identified designated E lights were inoperable. Identified there was no E light in the forward gear locker on the car deck and within the steering compartment. Repair E lights and demonstrate operation to attending Marine Inspector(MI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 April 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable. Unable to verify satisfactory operation of automatic fire dampers. Install inspection ports or provide proof of satisfactory damper operation to attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 April 2025 Resolved
Each vessel must be provided with a visual/audible alarm at the operating station to indicate a high water level in each space with a non-watertight closure , such as a space with a non-watertight hatch on the main deck. Cardeck flooding alarms found inoperable. Repair cardeck alarms and demonstrate operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2025
Resolution: Sensors replaced and proper function restored (Greenwell)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 March 2024 Resolved
A vessel must carry adequate and up to date charts. Master was unable to show when the electronic charts were last updated. Demonstrate that charts have been updated in the last 6 months. 46 CFR 121.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 March 2024 Resolved
Generators operating in parallel must meet the standards of 46 CFR 111.12-11(f). Each generator arranged for parallel operation must have reverse-power. The #2 Generator reverse power relay failed to operate. Repair or replace the relay and until such time, parallel operation is not permitted. Demonstrate proper operation to attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 22 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 March 2024 Resolved
A door must be capable of operation from either side by one person. The door from the galley to the weather deck required excessive force to open/close and dog down. Ensure the hinges and dogs are able to operate effectively and secure closed to meet the requirements for an A class fire boundary. 46 CFR 116.435(b)(2) & (c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 18 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 19 March 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The lever to deploy the MES is located well above the weather deck and requires crew to stand on a ladder in order to deploy the system. This arrangement puts the crew member well over the railing height and in danger of falling overboard in rough weather. Within 30 days, provide a plan to mitigate the risks currently associated with deploying the MES or a plan to replace the current system. Subchapter K requires a marine evacuation system used for embarkation of survival craft to meet 46 CFR 160.175 standards. That standard is no longer listed in the CFR. Without clear guidance on the requirements for the MES, the OCMI will attempt to use good marine practice proposed by the operator to address the above safety issue. 46 CFR 115.800(a) 46 CFR 117.150(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2023 Resolved
Generators operating in parallel must meet the standards of 46 CFR 111.12-11(f). Each generator arranged for parallel operation must have reverse-power. The #2 Generator reverse power relay failed to operate. Repair or replace the relay and until such time, parallel operation is not permitted. Demonstrate proper operation to attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2023
Resolved 22 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 December 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of th hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations: Currently the number 3 generator inoperable directly affecting the ability to use the ships bow thruster. Make repairs to the generator to the satisfaction of the attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 3 December 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Minimum requirements)
Issued 29 November 2022 Resolved
Every person assigned duty as officer in charge of navigational watch or engineering watch, or duty as ratings forming part of a navigational or engineering watch muct receive a minimum of 10 hours of rest in any 24 hour period. The hours of rest required may be divided into no more than two periods in any 24 hour period, one of which must be at least 6 hours in length. All crew members exceeded their working hours without rest. The master shall ensure crew members receive adequate rest prior to returning to passenger operations. 46 CFR 15.1111
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 May 2021 Resolved
Vessel must carry at least one operating rescue boat in the cradle. Repair the passenger grab lines and demonstrate lowering, running and recovery of the rescue boat. 46 CFR 117.210
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2021
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 May 2021 Resolved
Prior to carrying passengers demonstrate a man overboard and abandon ship drill to the satisfaction of attending CG Marine Inspector. 46 CFR 122.520
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 February 2019 Resolved
In accordance with 46 CFR 118.400 (e)(1) your vessel is required a smoke actuated fire detecting system of a type approved by the Commandant that is installed in accordance with 46 CFR 76.35. While conducting tests it was noted that your silence actuating button was not functioning properly on your fire detecting system. Make repairs within the 90days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2019
Resolved 9 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 July 2018 Resolved
Prior to carrying of passengers repair the #1 steering system and demonstrate to attending CG Marine Inspector. In addition, provide technicians report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2018
Resolved 14 July 2018
Engineering › Steering Gear System › Actuator
Issued 10 April 2018 Resolved
The #2 Steering system motor control when in local does not allow the pump to swing to the port, when in emergency mode. However, the steering system functions in all modes from the bridge including emergency mode with both pumps. Repair emergency local steering for #2 pump and demonstrate to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 16 May 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 January 2018 Resolved
Repair the exhaust fan shut-down device and re-test the suppression system to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 March 2018
Resolved 7 February 2018
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 May 2014 Resolved
Repair oil content meter, prove proper operation of OWS.
Action required: 705 - Other - as specified
Due 29 May 2015
Resolved 12 June 2015
Fire Fighting › Automatic Sprinkler System › Piping
Issued 15 May 2012 Resolved
Replace anti-freeze in sprinkler system.
Due 15 June 2012
Resolved 19 July 2012
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 15 May 2012 Resolved
Make sprinkler tank open for inspection.
Due 15 June 2012
Resolved 19 July 2012
Engineering › Steering Gear System › Follow-up Assembly
Issued 16 January 2010 Resolved
Prove proper operation of #1 steering system in follow up mode. Repair to be completed no later than 23 January 2010.
Action required: 705 - Other - as specified
Due 23 January 2010
Resolved 19 January 2010
Resolution: The poteniometers were adjusted back into range.
Fire Fighting › Fire Main › Valves
Issued 18 October 2007 Resolved
Replace/install overboard discharge valve in fire main system.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 19 October 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Shell
Issued 8 May 2007 Resolved
Conduct hydrostatic test on both ships heating boilers.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 31 October 2007
Communications › Audible Communications › SPD (Other)
Issued 20 January 2006 Resolved
Repair weather deck talk stations to audible condition.
Due 4 February 2006
Resolved 29 March 2007
Fire Fighting › Means of Escape › Doorways
Issued 20 January 2006 Resolved
Adjust port weather door in forward viewing area to prevent from sticking.
Due 27 January 2006
Resolved 29 March 2007
Electrical › Electric Generation Source (service) › Generator
Issued 19 December 2004 Resolved
Governor actuator plug was missing its retainer clip and vibrated loose causing generator prime mover shut down. Vessel shall make repairs to plug to ensure it is unable to vibrate free.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 December 2004
Resolved 19 December 2004
Resolution: Installed retainer clip and tested genset. All Sat.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 15 November 2004 Resolved
Remove all flammable paints, solvents, etc from boatswains (bosun) compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 January 2005
Resolution: Vessel removed all flammable materials from bosun compartment.
Documentation › Certificates/Documents
Issued 22 January 2004 Resolved
Provide elevator certification and post as required. System shall be locked out until item cleared by attending MI.
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 23 February 2004
Resolution: [name withheld] co. completed annual servicing with cert provided.
Construction/Loadline › Structures
Issued 6 January 2004 Resolved
Prove proper operation of port and starboard side passenger deck amidships doors. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 13 February 2004
Resolved 26 January 2004
Resolution: Door closure devices replaced and adjusted to close properly.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2004 Resolved
Prove proper operations of bow thruster & steering gear room light location indicators items installed must operate as designed. LEGACY COMPONENT DESC: Receptacle Outlet
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 26 January 2004
Resolution: Bulb replaced for bow thruster room light and properly wired both lights fixtures.
Fire Fighting › Grease Extraction Hood
Issued 6 January 2004 Resolved
Provide annual servicing certificate for unit. Servicing rep unavailable prior to inspection date therefore system secured till completion.
Due 6 February 2004
Resolved 24 January 2004
Resolution: Equipment annual servicing completed with certification provided on this date. Notified O/O that servicing required prior to anniversary date.
Accommodation/Occupational Safety › Cooking Systems
Issued 6 January 2004 Resolved
Prior to operation of stove have area clean and ready for inspection. Cleanliness must be to the satisfaction of the attending CGMI.
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 23 January 2004
Resolution: Attended vessel and witnessed the satisfactory cleanliness of stove area. Follow-up inspection shall be periodic due to second issuance of this requirement. KPB
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 6 January 2004 Resolved
Flush system until discharged fluid is meets system required Propylene glycol level as required in system design as well as NFPA 25. Flush shall be sufficient to eliminate any corrosion/ foreign matter in branch lines.
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 24 August 2004
Resolution: Chief Engineer [name withheld], indicated this task completion date of about March-April 2004 time frame & recorded, sat.
Fire Fighting › Automatic Sprinkler System › Test Valves
Issued 6 January 2004 Resolved
Identify required system maintenance and testing procedures, with demonstration of implement schedule as required by manufacture and NFPA 25.
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 24 August 2004
Resolution: Done. C/E produced a scheduled maintenance inspection as per NFPA 25, sat.
Operations/Management › Lifesaving
Issued 26 November 2002 Resolved
Upon temporary removal of one of your MEC unit vessels total person count shall be limited to 120 persons until completion of annual servicing & replacement of unit on vessel. This process shall be completed prior to the anniversary servicing date for units. KPB LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Due 11 January 2004
Resolved 1 April 2003
Resolution: Starboard unit replaced on 03MAR03, and port unit 01APR03 with all certs on board. KPB
Engineering › Shafting/Propeller Arrangements
Issued 4 September 2002 Resolved
Prove proper operation of the starboard CPU system prior to conducting commercial operations. Coast Guard Marine Inspector must clear this requirement. LEGACY COMPONENT DESC: Propeller (controllable pitch)
Due 4 September 2002
Resolved 15 September 2002
Resolution: Main breaker power requirement analysis complete with replacement in kind and further proper perimeters set. Cabling found bad and also replaced all with sat results, arrangement approved and working as designed and installed. KPB
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 4 September 2002 Resolved
Submit proposal for repair or replacement of CPU controlling system to this office for approval. KPB
Due 13 September 2002
Resolved 15 September 2002
Resolution: Due to current arrangement approved and tested satisfactory this requirement is here by rescinded. Vessel o/o intends to submit plans ASAP for spring installation. KPB
Engineering
Issued 4 September 2002 Resolved
Provide data required for failsafe feature of automated system.
Due 13 September 2002
Resolved 15 September 2002
Resolution: Received MSC ltr dated 01/25/02 however OCMI verification of FMA not documented completion therefore this office has scheduled to complete verification process during annual reinspection scheduled for Jan 03. KPB
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 26 June 2002 Resolved
Apply required marking at enterance to space containing bottles. KPB
Due 26 June 2002
Resolved 26 June 2002
Resolution: Inspected sat.
Operations/Management › Drills/Instruction
Issued 26 December 2001 Resolved
Conduct fire drill LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2002
Resolved 11 June 2002
Resolution: Completed satisfactory emergency drills. KPB
Operations/Management › Drills/Instruction
Issued 26 December 2001 Resolved
Conduct abandon ship drill LEGACY COMPONENT DESC: Abandon Ship
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Completed emergency drills. KPB
Operations/Management › Passenger Operations
Issued 26 December 2001 Resolved
Ensure vessels passenger safety bill is posted LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Observed posted inst. KPB
Operations/Management › Drills/Instruction
Issued 26 December 2001 Resolved
Ensure emergency instructions are posted LEGACY COMPONENT DESC: Emergency instructions
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Observed posted inst. KPB
Operations/Management › Navigation Safety
Issued 26 December 2001 Resolved
Ensure all required navigation publications are on board in accordance with 46 CFR 121.420 LEGACY COMPONENT DESC: Carriage of Charts and Publications
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: All pubs on board and current. KPB
Deck/Cargo › Mooring/Anchoring
Issued 26 December 2001 Resolved
Prove proper operation of anchoring system LEGACY COMPONENT DESC: Winch
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Tested of system completed by crew sat. KPB
Accommodation/Occupational Safety › Heating
Issued 26 December 2001 Resolved
Properly insulate steam pipe on heater unit in crew head LEGACY COMPONENT DESC: Radiator
Condition: Improper Installation
Due 31 January 2002
Resolved 23 January 2002
Resolution: Cover installed. KPB
Accommodation/Occupational Safety › Cooking Systems
Issued 26 December 2001 Resolved
Properly install sea rails on coffee maker
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Rails installed. KPB
Lifesaving › Rescue Boat
Issued 26 December 2001 Resolved
Install retro-reflective tape on rescue boat LEGACY COMPONENT DESC: Markings
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Inspected rescue boat all equipment and marking sat. KPB
Fire Fighting › Ventilation Systems
Issued 26 December 2001 Resolved
Properly label vehicle ventilation shut-downs with name of space protected LEGACY COMPONENT DESC: Damper Labels
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Inspected sat. KPB
Operations/Management › Drills/Instruction
Issued 26 December 2001 Resolved
Ensure vessel safety bill is posted LEGACY COMPONENT DESC: Safety Orientation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 11 January 2002
Resolution: Emergency bill posted and used during drills. KPB

Casualty record · 11

15 January 2002Routine · role: Involved in a Marine Casualty · activity 1485739
28 January 2002Routine · role: Involved in a Marine Casualty · activity 1487007
13 September 2005Routine · role: Involved in a Marine Casualty · activity 2615917
21 December 2005Routine · role: Involved in a Marine Casualty · activity 2622570
23 June 2007Routine · role: Involved in a Marine Casualty · activity 2984432
22 October 2009Routine · role: Involved in a Marine Casualty · activity 3620608
28 October 2009Routine · role: Involved in a Marine Casualty · activity 3627130
3 January 2013Routine · role: Involved in a Marine Casualty · activity 4513993
3 February 2013Routine · role: Involved in a Marine Casualty · activity 4528074
13 July 2018Routine · role: Involved in a Marine Casualty · activity 6481806
22 May 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6965812
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.