Records from 1991 to 2005. Most recent: inspection, 4 January 2005.
Inspection history · 32
4 January 2005
Random ISPS/MTSA/PSC · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2268395
7 December 2004
ISPS II Exam · COC-TVE Renew
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2254738
6 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2257663
26 February 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2013954
23 December 2003
Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968718
20 December 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1970587
13 February 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1744368
29 January 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1736873
29 January 2003
Special Interest Vessel
Type not classified · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1736986
9 January 2003
Special Interest Vessel
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1728208
28 September 2002
Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1681620
1 July 2002
Ballast Water Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1639589
8 May 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1615273
4 May 2002
Type not recorded
No type recorded · USCGC DAUNTLESS (WMEC 624) · Activity 1702237
28 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 480348
30 December 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 273315
6 October 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 433452
3 October 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 433239
14 May 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 482194
13 May 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 428459
9 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412645
11 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 511476
9 January 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 411693
3 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411289
16 June 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 504573
18 September 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 395674
12 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395293
28 December 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 386201
17 September 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 383968
26 September 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 477796
20 August 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 442219
18 July 1991
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255457
Electrical › Electric Generation Source (service) › Generator
Issued 4 January 2005
No resolution recorded
Diesel generators leaking / spraying excessive amounts of oil, this is a long time issue with the vessel, this problem to be addressed by Flag and the Safe Management Company (SMC). Provide all correspondence from flag and from SMC to USCG New York
Action required: 705 - Other - as specified
Due 4 February 2005 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Davit
Issued 7 December 2004
Resolved
Starboard side lifeboat davits will not move from the stowed position. Classs society to address condition prior to vessel departure from Port of NY.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2004
Resolved 9 December 2004
Resolution: ABS Rpt. No. NY-570341 received via fax. Lifeboat davits tested and found satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 7 December 2004
Resolved
All main diesel generators show signs of excessive oil leakage. Indications of oil spray are throughout general area and the small discharge containment under the generators is overflowing. Most temperature gauges are also inoperative. Class Society to address this condition and verify generators are suitable for service by 07 JAN 05.
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 4 January 2005
Resolution: Received copy report from Russian Maritime Register of Shipping showing item has been corrected.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 7 December 2004
Resolved
IG System is not capable of producing gas with an oxygen content below 5%. Vessel cargo authority is restricted to oils with a flashpoint above 60 degrees C (140 F) until Class Society verifies IG System meets SOLAS II-2/62.
Action required: 705 - Other - as specified
Resolved 4 January 2005
Resolution: Received copy report from Russian Maritime Register of Shipping showing item has been corrected.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 7 December 2004
Resolved
IG blower #2 has a temporary patch on discharge side. Since IG system is out-of-service I did not write this on Form B.
Due 7 December 2004
Resolved 7 December 2004
Deck/Cargo › Inert Gas System › IGS Blower
Issued 7 December 2004
Resolved
IG analyzer calibration gas content is not certified. Since IG system is out-of-order I did not write this on Form B.
Due 7 December 2004
Resolved 7 December 2004
Fire Fighting › Nozzles › Type
Issued 7 December 2004
Resolved
Straight stream nozzles were in the engine room, they were swapped for the deck nozzles that were capable of variable stream.
Due 7 December 2004
Resolved 7 December 2004
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 December 2004
Resolved
Tank TT3 fuel oil valve is leaking. The leak is to minor to be written on the Form B but enough to be mentioned here.
Due 7 December 2004
Resolved 7 December 2004
Fire Fighting › Fire Pumps › Gland Sealing
Issued 7 December 2004
Resolved
All three fire pumps had excessive leaking from packing gland. After discharge (light ship) the C/E will renew all. Before I left I had the C/E replace No. 3 FP packing and it was fine, on faith the other two should be done.
Due 7 December 2004
Resolved 7 December 2004
Deck/Cargo › Ballast › Pumps
Issued 7 December 2004
Resolved
#2 Ballast pump in pump room leaks excessively. C/E will change mechanical seal after discharge (light ship).
Due 7 December 2004
Resolved 7 December 2004
Fire Fighting › Structural - A Class Divisions
Issued 23 December 2003
Resolved
Structural fire protection insulation on overhead in starboard forward storeroom damaged. LEGACY COMPONENT DESC: Bulkheads - Store-rooms
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2004
Resolution: Received official report from the Master attesting to the satisfactory repair of insulation.
Communications › Alarms/Indicators
Issued 23 December 2003
Resolved
General alarm bell located on forward portion of the mast located on the forecastle is inoperable. LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 January 2004
Resolution: Received official report from Master attesting to proper operation of general alarm bell located on the forecastle.
Pollution Prevention/Response › Prevention Equipment
Issued 23 December 2003
Resolved
Tank overfill alarm light located on cargo deck inoperable. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2004
Resolution: Received official report from Master attesting to proper operation of tank overfill alarm light.
Navigation › Collision/Grounding Avoidance
Issued 29 January 2003
Resolved
Repair secondary radar display unit. Provide technician's report attesting to the satisfactory repair. Prior to departure. LEGACY COMPONENT DESC: Radar
Due 29 January 2003
Resolved 30 January 2003
Resolution: Received faxed techinician''s report stating radar display has been repaired.
Engineering › Steering Gear System
Issued 28 September 2002
Resolved
Port steering gear pump was found leaking excessively at the high pressure piping to junction box connection. LEGACY COMPONENT DESC: Hydraulic Pump
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2002
Resolved 29 September 2002
Resolution: Received class report stating copper gasket was replaced an pipe realigned. Tested with no leaks.
Engineering › Steering Gear System
Issued 28 September 2002
Resolved
The Starboard steering gear high pressure piping was found with a temporary braze repair. ABS reviewed the repair and deemed it satisfactory . A condition of class was issued to make permanent at the next port of call or 21 NOV 02. Vessel's restriction was rescinded.
LEGACY COMPONENT DESC: Piping
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 November 2002
Resolved 26 February 2004
Resolution: Received report from class attesting to proper repairs.
Navigation › Emergency Steering
Issued 8 May 2002
Resolved
The high pressure supply line from the emergency steering pump to the distribution block has a temporary repair weld.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2002
Resolved 1 July 2002
Resolution: THE HIGH PRESSURE SUPPLY LINE FOR THE EMERGENCY STEERING PUMP HAD BEEN REPAIRED.
Fire Fighting › Structural Fire Protection - General
Issued 8 May 2002
Resolved
Fire detection system for the lower level pump room and main deck workshops bypassed by crew in the alarm panel. LEGACY COMPONENT DESC: Fire Detection Alarms
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 May 2002
Resolved 8 May 2002
Resolution: Electrician corrected alarm panel and alarms tested satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2002
Resolved
ODME inoperable. LEGACY COMPONENT DESC: Cargo Monitor/Control System
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 9 May 2002
Resolved 28 September 2002
Resolution: Vessel installed new ODME Model 5663 MKIII CG Approval #162.050/6003/3.
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2002
Resolved
Vessel entered NEWMS with cargo tanks 1S, 4S, 5S, 7S and 8S Tank Overfill alarms indicating tank level above preset limits. Vessel allowed a one-time discharge and prohibited from loading cargoes that require Tank Overfill alarms in U. S. waters until proper operation is demonstrated to USCG. LEGACY COMPONENT DESC: Overfill Devices
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2002
Resolved 1 July 2002
Resolution: THE OVERFILL ALARMS ON CARGO TANKS 1S,4S,5S,7S,AND 8S WERE REPAIRED AND DEMONSTRATED TO OPERATE CORRECTLY TO USCG.
Construction/Loadline › Structures
Issued 8 May 2002
Resolved
Temporary weld repairs to the scrubber piping. Class issued a condition to make permanent repairs prior to next cargo loading but not later than 05 June 2002. LEGACY COMPONENT DESC: Scupper
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2002
Resolved 1 July 2002
Resolution: TEMPORARY REPAIRS CORRECTED TO PERMANENT AS REQUIRED AND FOUND TO BE CORRECT.
Fire Fighting
Issued 13 May 1999
Resolved
Fire fighting mask straps were cracking and would not retract once they were stretched.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Construction/Loadline
Issued 3 January 1998
Resolved
NUMEROUS WEATHERTIGHT DOORS IMPROPERLY MAINTAINED - DO NOT SEAL PROPERLY.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 3 January 1998
Resolved
NUMEROUS LIGHTS BURNED OUT IN ENGINEERING SPACES.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Fire Fighting
Issued 3 January 1998
Resolved
TEMPORARY REPAIRS MADE TO PIPING FROM #1 FIRE PUMP. NO LEAKAGE NOTED AT THE TIME OF THE EXAM.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 3 January 1998
Resolved
EXCESS OIL THROUGHOUT ENGINEROOM DUE TO POOR HOUSEKEEPING.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Electrical
Issued 3 January 1998
Resolved
STEAM LEAKS ON GENERATOR STEAM TURBINE.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 3 January 1998
Resolved
NUMEROUS COMPRESSED GAS BOTTLES IMPROPERLY STOWED IN IGS ROOM.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Accommodation/Occupational Safety
Issued 3 January 1998
Resolved
UNABLE TO OPEN EMERGENCY EXIT DOOR LOCATED IN THE ENGINEROOM LOWER LEVEL AFT.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Fire Fighting
Issued 3 January 1998
Resolved
EMERGENCY FIRE PUMP INOPERABLE.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Deck/Cargo
Issued 3 January 1998
Resolved
CARGO PIPING NOT TESTED TO 1.5 X MAWP. PIPING WAS TESTED TO 10.5KG ON 07JUL97. MAWP WAS 8KG. VESSEL RESTRICTED TO CARGO PIPING OPERATING PRESSURES AT OR BELOW 7KG.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Deck/Cargo
Issued 3 January 1998
Resolved
FOUNDATION FOR CARGO MANIFOLD CONTAINMENT WASTED.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 3 January 1998
Resolved
NUMEROUS DECK PLATES IN ENGINEROOM DETERIORATED/HOLED.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Documentation
Issued 3 January 1998
Resolved
MISSING POLLUTION PLACARD.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Fire Fighting
Issued 3 January 1998
Resolved
FIREFIGHTING EQUIPMENT NOT STOWED IAW FIRE CONTROL PLAN. EQUIPMENT WAS ON BOARD.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Deck/Cargo
Issued 3 January 1998
Resolved
CARGO TANK OVERFILL ALARMS NOT LABELED ON DECK.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Documentation
Issued 17 September 1995
Resolved
Provide transfer procedures iaw 33 CFR 155.750 prior to cargo transfer.
Condition: Unknown
Due 18 September 1995
Resolved 18 October 1995
Electrical
Issued 17 September 1995
Resolved
Properly electrically bond ships piping systems; cargo, COW, steam, IGS prior to next cargo transfer.
Condition: Unknown
Due 17 September 1995
Resolved 20 October 1995
Engineering
Issued 17 September 1995
Resolved
Make permanent repair to stbd. boiler steam atomizer line prior to 30 SEP 95.
Condition: Unknown
Due 30 September 1995
Resolved 20 October 1995