MAURY USCG vessel records
← All vessels

TRADEWINDS

TRADEWINDS is a 1991 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in November 2025, along with 42 deficiencies and 2 casualty investigations between 2011 and 2017.

Records from 2011 to 2025. Most recent: inspection, 6 November 2025.

Built
1991
Last inspected
6 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDE2696
364999
Flag
UNITED STATES
Maury page id
psix-364999

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

6 November 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8261361
29 May 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8147126
7 April 2025 Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8106754
4 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7874112
31 October 2023 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7817934
26 October 2023 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814791
9 January 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7618757
12 October 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7575670
9 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7447516
26 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7386134
9 August 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7283486
8 January 2021 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7121498
12 May 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6910967
30 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900134
26 September 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822766
15 January 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6611031
24 April 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6400073
15 March 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368976
6 May 2017 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6198319
19 January 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6070625
3 March 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815281

Deficiency record · 42

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2025 Resolved
Vessel missed window for Annual Inspection due to pending repairs to stern deck. Vessel must complete satisfactory COI inspection prior to operating with passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2025
Resolution: Vessel completed satisfactory COI Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2023 Resolved
Vessel must carry one floating water light, unless it is limited to daytime operation. Vessel found with expired batteries in water light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2023
Resolution: Batteries provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 January 2023 Resolved
Provisions must be made for closing all supply duct cowls or scoops openings for a space protected by a fixed gas extinguishing system. Vessel found with missing ventilation closure or port engine room vent.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2023
Resolution: Closure provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 January 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 March 2024
Resolution: Verified system complies with 46 CFR 181.450; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 May 2022 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. E-pirb was not mounted and registration was not provided.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Epirb was mounted and registration provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 May 2022 Resolved
Provide proof of crew training in accordance with 46 CFR 185.420. Current drill log could not be provided.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Drill log provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 May 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. Battery switch was bypassed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 May 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.808. A/c water pump electrical connections were unsatisfactory.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 9 May 2022
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 January 2022 Resolved
Hull separation noted IWO forward port side passenger accomodation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2022
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 January 2022 Resolved
Crack noted in stringer in aft port side passenger accomodation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2022
Resolution: Suspected crack was a rusted fastener.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2022 Resolved
Remove/replace cutlass bearings due to excessive wear.
Action required: 705 - Other - as specified
Resolved 9 May 2022
Resolution: Bearings renewed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 January 2021 Resolved
Update Nautical Publications to most recent version/edition. (Light List, Coast Pilot, and Tide Tables).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 8 February 2021
Resolution: Provided photographic proof of updated Nautical publications.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 January 2021 Resolved
Provide proof of paddles for life float. Current set are broken and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 8 February 2021
Resolution: Provided photographic proof of newly purchased paddles for Life Float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2021 Resolved
5 PFD's unservicable. Repair, replace, and provide proof of replacements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 8 February 2021
Resolution: Vessel owner provided proof 05 newly purchased PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 January 2021 Resolved
Replace recovery ladder with a sturdier structure. Provide proof of replacement.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 8 February 2021
Resolution: Vessel owner provided photographic proof of newly purchased recover ladder.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 8 January 2021 Resolved
Repair Bridge Window to fix cracking. Complete at Drydock
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 May 2022
Resolved 4 March 2024
Resolution: Verified bridge window has been replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 January 2021 Resolved
Program DSC Radio to properly operate. Provide proof of operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 9 March 2021
Resolution: Vessel owner provided evidence of programmed DSC radio.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 January 2021 Resolved
Properly secure water-tank in Lazerrete. Currently the tank is held by straps to secure tank in place.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 8 February 2021
Resolution: Vessel owner properly secured water tank in the lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2021 Resolved
Seal forward and aft Engine Room penetrations.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 8 February 2021
Resolution: Vessel owner provided proof of Forward and Aft Engine Room penetrations being sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2021 Resolved
Remove Generator Battery Lead. Provide proof of replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 8 February 2021
Resolution: Vessel owner provided proof of replaced Generator Battery lead.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 8 January 2021 Resolved
Secure wooden seats on the Main Deck. The current set are not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 8 February 2021
Resolution: Vessel owner provided proof of wooden seats on the Main Deck being repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2021 Resolved
Soft deck on the Starboard side and bow of vessel. Correct and provide proof. To be completed during Drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2022
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 January 2021 Resolved
Reduce passenger count due to newly acquired Generator held onboard. Passenger count reduced by 3 until discrepancy corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 March 2024
Resolution: Corrected. Generator remains onboard. Pax count reduced 03, COI amended to reflect and Special Note added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 January 2021 Resolved
Replace starboard engine Fire Bowl.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 9 March 2021
Resolution: Vessel owner provided photographic evidence of starboard engine fire bowl being replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019 Resolved
Vsl required to have 1 waterlight that meets 46 CFR 160.050. The waterlight globe to protect light fillament is missing. Vsl to replace waterlight. Vsl limited to daytime operations. 46 CFR 180.70(d)(1) 705c
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 26 September 2019
Resolution: Waterlight was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019 Resolved
Vsl waterlight required to have 3 ft line. Vsl had line less than 3 ft attached to light. Vsl to replace with 3 ft line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced line with 3 ft line.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 September 2019 Resolved
Emergency escape must be marked in letter 1" high EMERGENCY EXIT KEEP CLEAR. Vsl did not have exit marked as required. Vsl to mark exit appropriately. Vsl restricted from carrying passengers overnight until rectified. 46 CFR 177.15 46 CFR 185.30-15 705c
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 2 October 2019
Resolution: The owner intalled a sign that is mounted at top of stairs for passengers to see regardless of which bunk house they are assigned to sleep.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2019 Resolved
Life jackets are required for every person onboard. 1 lifejacket was unservicable. Vsl limited to total of 51 passengers until rectified. 46 CFR 180.71(a) 705c
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 2 October 2019
Resolution: Owner purchased new jacket and outfitted/marked it as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2019 Resolved
Vsl has flammable items stored in accommodation space. Vsl to remove items. 46 CFR 177.800(c) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2019
Resolved 26 September 2019
Resolution: Vsl removed items from accomodation spaces.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 September 2019 Resolved
Vsl to renew emergency fuel shut off markings. 46 CFR 185.30-20 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2019
Resolved 26 September 2019
Resolution: Vsl marked fuel shut offs.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 September 2019 Resolved
Vsl required to have a total of 5 extinguishers onboard. 1 extinguisher found unservicable vsl to replace. 46 CFR 181.500 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2019
Resolved 26 September 2019
Resolution: Vessel had extinguisher serviced.
Lifesaving › Lifefloat › Serviceable
Issued 15 March 2018 Resolved
Repair the straps hold the net on the Life Float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2018
Resolved 23 March 2018
Resolution: Had new strps made and attached to Life float.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 15 March 2018 Resolved
Smoke detector missing from Aft Berthing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2018
Resolved 23 March 2018
Resolution: New smoke detector installed.
Engineering › Fuel Oil Service System › Valve
Issued 19 January 2017 Resolved
fuel shut off valves were inop
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 January 2017 Resolved
Retro needs to be replaced on 9 life jackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: Retro was replaced.
Lifesaving › Lifefloat › Paddle
Issued 19 January 2017 Resolved
Life float oars were not tied down.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Construction/Loadline › Hull › Bracket
Issued 19 January 2017 Resolved
Fiberglass in Forward compartment needs to be replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: Fiberglass was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 January 2017 Resolved
not operable
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: replaced.
Construction/Loadline › Hull › Side Shell
Issued 19 January 2017 Resolved
Aft Upper Deck new cover is needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 January 2017 Resolved
Lights in head need to be replaced
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Construction/Loadline › Hull › Hull Plating
Issued 3 March 2016 Resolved
FIBERGLASS AREA UP FORWARD NEEDS TO BE REPLACED
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Resolution: Fiberglass was repaired
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 3 March 2016 Resolved
Replace cutlas bearings
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Resolution: cutlas bearings were replaced

Casualty record · 2

9 September 2011Routine · role: Involved in a Marine Casualty · activity 4150061
6 May 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6198319
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.