Records from 2000 to 2010. Most recent: inspection, 21 December 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 September 2010
Resolved
Update first-aid-kit.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Documentation › Certificates/Documents › FCC SSL
Issued 9 September 2010
Resolved
Provide updated FCC Station License.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 September 2010
Resolved
Show that floating water light for life float is stored in a float free arrangement and 18" of line is attached to the float.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Lifesaving › Lifefloat › Serviceable
Issued 9 September 2010
Resolved
Service life float IAW MFG recommendations.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2010
Resolved
Show proper operation of stern light.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2010
Resolved
Repair/replace aft high water indicator (light) at operating station.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 November 2010
Engineering › Bilge Water Management System › Not Operational
Issued 30 December 2009
Resolved
In the presents of a USCG Marine Inspector show operation of the following: A) fixed bilge system. B) Engine shut down for fixed fire extinguishing system. C) Main Engine operation U/W test. D) Emergency steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 December 2009
Resolved
In the presents of a USCG Marine Inspector show proper drills while U/W(fire/man overboard and steering).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 30 December 2009
Resolved
Provide name of vessel on P/S bow and name and hailing port on stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Documentation › Certificates/Documents › FCC SSL
Issued 30 December 2009
Resolved
Provide onboard FCC Radiotelephony Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 30 December 2009
Resolved
Provide emergency broadcast placard at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 December 2009
Resolved
Update first-aid-kit IAW 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 December 2009
Resolved
Provide 02 lifejackets for total of 24 (type I, USCG approved).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 December 2009
Resolved
Mount terminal blocks under lower operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 December 2009
Resolved
Make repairs to ladder going down to head.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 30 December 2009
Resolved
Provide 3/4 level indicator on MSD tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Lifesaving › Lifefloat › Serviceable
Issued 30 December 2009
Resolved
Service life float IAW MFG instructions and IAW 46 CFR 180.175 and ensure the following: A) 4ft floating paddles are replaced. B) Retro tape is replaced. C) Name of vessel and capacity of life float is re-marked on float. D) Repair/painting of life float are IAW MFG Instructions. E) Provide 18 ft of line for floating water light on life float. F) Make water light float free. Make all available fo
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 30 December 2009
Resolved
Provide notification to USCG once MDE is back in service and show proper operation to USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 December 2009
Resolved
Submit to Annual Exam, prior to the carriage of passengers. Vessel found overdue for annual 4 months and 3 days (Anniversary date is 20May09 and drop dead date is 20Aug09).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2009
Lifesaving › Buoyant Apparatus › Capacity
Issued 16 May 2008
Resolved
Provide proof of capacity for life float and install proper sized weak link.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Lifesaving › Buoyant Apparatus › Serviceable
Issued 16 May 2008
Resolved
Repair worn/cracked areas on life float per manufacturers recommendation.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 16 May 2008
Resolved
Properly install retro-reflective tape to underside of life float.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 16 May 2008
Resolved
Replace worn grab lines on life float.
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 23 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2008
Resolved
Prove proper operation for bilge high level alarm indicators at upper operating station for fwd compartment and engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2008
Resolved 21 May 2008
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 7 April 2008
Resolved
Replace worn strut bearing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 7 April 2008
Resolved
Resurface or replace damaged propeller.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Construction/Loadline › Structures › Deck Plating
Issued 7 April 2008
Resolved
Replace missing bolts on dive platform
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 April 2008
Resolved
Properly store adult and child lifejackets seperate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Engineering › Steering Gear System › Rudder
Issued 7 April 2008
Resolved
Install rudder stops IAW 46 CFR 182.610(e)
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 20 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2008
Resolved
Remove or properly terminate deadend wires on bow prop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2008
Resolved
Make repairs to aft bilge high level alarm for upper operating station indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Communications › Audible Communications › Horn/Whistle
Issued 7 April 2008
Resolved
Provide sound producing device for upper operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 April 2008
Resolved
Make repairs to life float water light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 7 February 2008
Resolved
Conduct satisfactory installation and operational test of vessel machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2008
Resolved 11 April 2008
Lifesaving › Hand Flares › Quantity
Issued 17 August 2006
Resolved
Provide 3 more flares or smokes onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Lifesaving › Lifebuoys › Serviceable
Issued 17 August 2006
Resolved
Re-new life ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 August 2006
Resolved
Provide two working flashlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 August 2006
Resolved
Provide 3 more adult PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Engineering › Bilge Water Management System › Pump
Issued 17 August 2006
Resolved
Prove proper operation of bilge pump system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Lifesaving › Lifefloat › Serviceable
Issued 17 August 2006
Resolved
Renew 6' pendants and retro tape on lifefloat prior to operating beyound 3 miles.
Due 17 September 2006
Resolved 27 February 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 August 2006
Resolved
Provide replacement license ( damaged).
Due 17 September 2006
Resolved 27 February 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 17 August 2006
Resolved
Provide replacement Marine Radio operator permit ( damaged).
Due 17 September 2006
Resolved 27 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 August 2006
Resolved
Provide complete first aid kit.
Due 17 September 2006
Resolved 27 February 2007
Lifesaving › Lifefloat › Float Free
Issued 29 March 2006
Resolved
Remove excessive items from lifefloat.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 31 March 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 29 March 2006
Resolved
Replace reflective tape on lifefloat
Action required: 705 - Other - as specified
Resolved 31 March 2006
Lifesaving › Lifefloat › Markings
Issued 29 March 2006
Resolved
Make lifefloat international orange prior to next annual exam dated APR2006
Action required: 705 - Other - as specified
Resolved 30 August 2007
Resolution: onboard
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2006
Resolved
Properly weld handrails on starboard side located near the deck
Action required: 705 - Other - as specified
Resolved 30 August 2007
Resolution: onboard
Engineering › Shafting/Propeller Arrangements › Strut
Issued 29 March 2006
Resolved
Reapir/Replace starboard trim tab. Repair.Replace hydrolic pump controlling trim tab.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 29 March 2006
Resolved
Starboard fuel oil tank vent cover is damaged
Action required: 705 - Other - as specified
Resolved 31 March 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006
Resolved
Repair port side amidship holes at the gunnel located above the rubrail
Action required: 705 - Other - as specified
Resolved 31 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2006
Resolved
Patch exposed fiberglass located near sea suction screen.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006
Resolved
Retab corner crack on starboard side box.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2006
Resolved
Repair 01 crack and 01 hole on starboard side near bow. Properly scarf hole at 12:1 radius.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2006
Resolved
Resin at the bow thruster propeller behind gear box.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Fire Fighting › Fire Hydrants › Condition
Issued 29 March 2006
Resolved
Replace Type II fire extinguisher located at the lower navigation consul.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 March 2006
Resolved
Battery terminals heavily corroded in engine compartment. Clean battery terminal
Action required: 705 - Other - as specified
Resolved 31 March 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 March 2006
Resolved
Prove watertight integrity of deck hatches.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 April 2005
Resolved
Renew reflective material on noted lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 29 March 2006
Lifesaving › Lifejacket/PFD (Type V) › Retroreflective Material
Issued 14 April 2005
Resolved
Renew ring buoy and life float reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 29 March 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 April 2005
Resolved
Post emergency instruction placards.
Condition: Improper/Lack of Maintenance
Due 18 April 2005
Resolved 29 March 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 April 2005
Resolved
Replace missing adult life jacket prior to carrying more than 23 passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2005
Resolved
Provide inspection certificate for fixed fire system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 18 April 2005
Engineering › Bilge Water Management System › Valve
Issued 14 April 2005
Resolved
Develop plan proposal to install access to submersible bilge pump hull penetrations valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 29 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2005
Resolved
Provide proof of vessel FCC station license.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2005
Resolved 18 June 2005
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 14 April 2005
Resolved
Renew or replace anchor chain and line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 29 March 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2005
Resolved
Weld aft port rail stanchion and install safety chain starboard side to dive ladder.
Condition: Improper/Lack of Maintenance
Due 16 May 2005
Resolved 29 March 2006
Engineering › Diesel Engine (propulsion-electric)
Issued 17 March 2004
Resolved
Replace exhaust hose in engine compartment. LEGACY COMPONENT DESC: Piping (exhaust)
Due 2 April 2004
Resolved 23 March 2004
Construction/Loadline › Penetrations
Issued 17 March 2004
Resolved
Repair/Replace thru-hull valve for sewage system.
Due 19 March 2004
Resolved 18 March 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 March 2004
Resolved
Repair cracked weld on aft handrail on starboard side of transom.
Due 2 April 2004
Resolved 29 March 2006
Construction/Loadline › Hull › Side Shell
Issued 17 March 2004
Resolved
Repair gunwale on port side aft in way of rub rail.
Due 17 April 2004
Resolved 14 April 2005
Construction/Loadline › Structures
Issued 5 May 2003
Resolved
Provide closing device for E/R weathertight hatch LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper Installation
Due 5 May 2003
Resolved 9 June 2003
Construction/Loadline › Structures
Issued 5 May 2003
Resolved
Provide securing device for aft weathertight hatch LEGACY COMPONENT DESC: Manhole
Due 15 May 2003
Resolved 9 June 2003
Engineering › Bilge Water Management System
Issued 5 May 2003
Resolved
Provide positive shut-off valve at the hull penetration for the electric submersible pump LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 15 May 2003
Resolved 9 June 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 May 2003
Resolved
Distribute lifejackets throughout vessel. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 15 May 2003
Resolved 9 June 2003
Lifesaving › Buoyant Apparatus
Issued 5 May 2003
Resolved
Replace lifeline pendant LEGACY COMPONENT DESC: Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2003
Accommodation/Occupational Safety
Issued 13 March 2001
Resolved
Replace/Renew Aft. Stbd. seats and railing.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Lifesaving
Issued 13 March 2001
Resolved
Provide donning instructions for jacket type PFD's.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Construction/Loadline
Issued 13 March 2001
Resolved
Provide high water alarms on flybridge operating station.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Navigation
Issued 13 March 2001
Resolved
Provide emergency tiller.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Accommodation/Occupational Safety
Issued 13 March 2001
Resolved
Provide loud hailer.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Lifesaving
Issued 13 March 2001
Resolved
Update emergency check off list.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Documentation
Issued 30 March 2000
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 30 April 2000
Resolved 18 May 2000
Documentation
Issued 30 March 2000
Resolved
PROVIDE VALID FCC STATION LICENSE
Condition: Unknown
Due 30 April 2000
Resolved 18 May 2000
Documentation
Issued 30 March 2000
Resolved
PROVIDE FCC SAFETY CERTIFICATE
Condition: Unknown
Due 30 April 2000
Resolved 18 May 2000