MAURY USCG vessel records Sign in
← All vessels

BONITO

BONITO is a 1987 tank ship. The Coast Guard has recorded 24 inspections since 1991, most recently in May 2008, along with 13 deficiencies — 6 with no resolution recorded — and 1 operational control.

Records from 1991 to 2008. Most recent: operational control imposed, 20 May 2008.

Built
1987
Last inspected
12 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8615552 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
365000
Flag
MARSHALL ISLANDS
—
Maury page id
psix-365000

Inspections, by type

…with no type recorded16
…past their stated due date6
Years with a record 10 calendar years (1991–2008)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it43406 - Simplified, Gross Ton
43406 - Convention (Subpart B), Gross Ton
26562 - Convention (Subpart B), Net Ton
83987 - Dead Weight, Ton
98885 - Displacement, Ton
26562 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

IB 923 Tank Barge · MISLE 41436 · 24 January 1993 · activity 106689BIG SAM Towing Vessel · MISLE 130323 · 24 January 1993 · activity 106689

Inspection history · 24

12 May 2008 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3199930
11 May 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3203836
7 April 2004 MTSA/ISPS Verification · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2039152
3 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291498
3 July 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1454966
9 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 715655
1 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 143217
1 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382185
22 July 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280219
22 July 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821414
25 January 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 412189
23 January 1998 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368563
4 November 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 384274
14 April 1994 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1167029
24 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 106689
14 January 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 355706
14 January 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 538818
13 January 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 355639
13 January 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 355707
13 January 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134883
25 January 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355843
27 September 1991 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 346296
13 July 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 344856
13 July 1991 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 939695

Deficiency record · 13

Deck/Cargo › Cargo Stowage › General
Issued 12 May 2008 No resolution recorded
1140 cubic meters of gas condensate from the #6 port side cargo tank has leaked into the #6 port side ballast tank.
Action required: 15 - Rectify deficiencies by next port
Due 14 May 2008 — due date passed with no resolution recorded
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 12 May 2008 No resolution recorded
Fire control plan indicates cargo control room is enclosed by an 'A' boundary. The door leading to the accommadation passage from the CCR is not self closing.
Due 14 June 2008 — due date passed with no resolution recorded
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 12 May 2008 No resolution recorded
An air conditioning unit has been mounted on the wall dividing the cargo control room, and gymnasium, with only a particle board and laminate enclosure serving as the boundary protection for the two spaces. SOLAS 74 (Amended), '92 Consolidated, II-2/47.1
Due 14 June 2008 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 12 May 2008 No resolution recorded
Ship has a steam leak in purifier room adjacent to oil purifiers.
Due 14 June 2008 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Tank
Issued 12 May 2008 No resolution recorded
Cascade tank foundation is wasted.
Due 14 June 2008 — due date passed with no resolution recorded
Deck/Cargo › Cargo Stowage › General
Issued 11 May 2008 No resolution recorded
Your vessel has a breach in the #6 port cargo tank which is discharging cargo into #6 port ballast tank. 19MAY08-The Port of Houston has reviewed and approved the vessel discharge and repair plan of DNV report survey report #15330 (CC-101).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2008 — due date passed with no resolution recorded
Electrical
Issued 3 July 2001 Resolved
LIGHT IN CARGO CONTROL ROOM FOR THE LOW OVERBOARD SEA VALVE (VI8-4) IS NOT OPERATIONAL.
Condition: Unknown
Due 3 August 2001
Resolved 7 April 2004
Construction/Loadline
Issued 1 April 2001 Resolved
The vessel's crew used emergency ballast procedures to ballast the number 4cargo tanks in violation of 33 CFR 157.35 in order to trim the vessel for cargo ops. Highly suspect this led to oil spill of Jet A-1 fuel discoveredaround and underneath vessel.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 4 November 1995 Resolved
PRIOR TO DEPARTING PORT, HAVE ATTENDING CLASS SOCIETY (DNV) CONFIRM THAT BALLAST SYSTEM CAN BE OPERATED SAFELY WITH THE TEMPORARY PATCHES.
Condition: Unknown
Due 4 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 4 November 1995 Resolved
PRIOR TO DEPARTING PORT, HAVE ATTENDING CLASS SOCIETY (DNV) CONFIRM PROPER OPERATION OF THE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 4 November 1995
Resolved 6 November 1995
Documentation
Issued 13 January 1993 Resolved
PROVIDE COPIES OF NEW LOADLINE AND SAFETY CONSTRUCTION CERTIFICATES ON 15JAN93.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Unknown
Issued 13 July 1991 Resolved
VESSEL FAILED TO NOTIFY COTP THAT ECHO DEPTH SOUNDER WAS INOPERATIVE._x001C_
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Navigation
Issued 13 July 1991 Resolved
VESSEL'S ECHO DEPTH SOUNDER WAS INOPERATIVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993

Ownership record