Records from 1991 to 2025. Most recent: inspection, 28 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
28 May 2025
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106648
28 May 2024
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922794
30 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684310
1 June 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412302
9 April 2021
Hull Examination · COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7171971
8 October 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073853
7 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6999955
4 June 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690442
8 June 2018
Annual Inspection · DAPI Audit · MARPOL Annex VI Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429948
7 July 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6206475
7 June 2017
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142932
31 May 2017
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6229525
30 March 2016
Spot Check · Drydock Extension · Examination of Repairs · Plan Review "T" Boat · Administrative Inspection · Deficiency Check · Internal Structural Exam · Special · DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5844454
9 June 2014
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4872281
27 May 2012
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4319791
6 January 2009
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3389378
26 April 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2910463
1 February 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2581684
2 April 2005
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2295370
4 May 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2059917
29 March 2004
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022916
17 February 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2008079
29 March 2003
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1757044
14 May 2001
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1063388
5 July 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823516
10 June 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 678657
14 April 2000
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458750
10 April 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 91578
10 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 231566
10 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816948
29 June 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080705
14 May 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372645
27 May 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126388
20 May 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471505
30 April 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394731
24 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086367
16 May 1996
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374604
15 June 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420984
12 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356684
22 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 187269
8 September 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399912
8 March 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835087
17 December 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1135896
2 September 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 958287
14 June 1991
Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 936813
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024
Resolved
46CFR182.460(e)
Exhaust blower switches must be of the type interlocked
with starting switch and the ignition switch so that the
blowers are started before the starter motor circuit or
engine ignition is energized. Noted there was no
interlock between blower and ignition switch, vessel was
able to operate without blowers being energized. Prove
proper operation within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 27 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2021
Resolved
Prove proper servicing of installed fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: Reviewed servicing report, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019
Resolved
Ring Buoy found with deteriorating grab line due to UV degradation. Provide proof of serviceable approved ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 June 2017
Resolved
Ensure the vessel’s current COI is available in the office area. A new COI willl need to be mailed to the vessel. Only the temp COI (expired) was available.
Condition: Invalid
Due 7 July 2017
Resolved 7 July 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 June 2017
Resolved
Ensure a fire retardant foam is installed on the vent closures.
Condition: Design Flaw
Due 14 July 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 June 2017
Resolved
Repair or replace the two spare child PFD’s with bad retro (worn).
Condition: Improper/Lack of Maintenance
Due 7 June 2017
Resolved 7 June 2017
Resolution: Repalced with new PFD's
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 May 2016
Resolved
Install chaffing gear on the outboard engines hydraulic hoses.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 14 June 2016
Resolution: Photo
Construction/Loadline › Hull › Weld
Issued 30 May 2016
Resolved
Prior to operating the vessel in 2017: Permanently weld the small pin hole fracture in port, bow, deck edge area. This area is well above the waterline.
Condition: Design Flaw
Due 15 May 2017
Resolved 7 June 2017
Construction/Loadline › Hull › Hull Plating
Issued 30 May 2016
Resolved
Prior to operating the vessel in 2017: Permanently weld the gouge in the stbd exterior, side of the hull, bow area, above the angle strake.
Condition: Damaged By Earlier Event
Due 15 May 2017
Resolved 7 June 2017
Construction/Loadline › Structures › Rake
Issued 30 May 2016
Resolved
Prior to operating the vessel in 2017: Weld the #5 skip weld on the stbd, bow, exterior, angle strake area.
Condition: Damaged By Earlier Event
Due 15 May 2017
Resolved 7 June 2017
Construction/Loadline › Hull › Transverse Frame
Issued 30 May 2016
Resolved
Prior to operating the vessel in 2017: Weld the port outboard side, interior floor frame, where it intersects with the hull chine. This is the 2nd frame forward of the engine room bulkhead. The frame was not completly welded.
Condition: Improper Installation
Due 15 May 2017
Resolved 7 June 2017
Engineering › Bilge Water Management System › Pump
Issued 30 March 2016
Resolved
Prove proper operation of the fwd (cabin bilge pump).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2016
Resolution: Pump was removed and cleaned of debris (sand and grit). The pump operated normally.
Engineering › Bilge Water Management System › Not Operational
Issued 2 April 2005
Resolved
Prove proper operation of high level bilge alarm. (46 CFR 182.530)
Due 2 May 2005
Resolved 15 May 2005
Resolution: High level bilge alarm operational.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 2 April 2005
Resolved
Wire power ventilation system into automatic fire extinguishing system. (46 CFR 181.420(3))
Due 2 May 2005
Resolved 15 May 2005
Resolution: Ventilation system tied into fire extinguishing system shutdown.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 April 2005
Resolved
Provide flame screens for fuel tank vent pipe (30x30 mesh). 46 CFR 182.450(e)).
Due 2 May 2005
Resolved 15 May 2005
Resolution: Ventilation screens applied.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 April 2005
Resolved
Renew hand bilge pump hose. (46 CFR 182.510)
Due 2 May 2005
Resolved 15 May 2005
Resolution: Hand bilge pump hose replaced.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 2 April 2005
Resolved
Provide portable lights. (46 CFR 183.430)
Due 2 May 2005
Resolved 15 May 2005
Resolution: Lights provided.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 April 2005
Resolved
Provide second life vest donning placard for vest type jackets. (46 CFR 185.516)
Due 2 May 2005
Resolved 15 May 2005
Resolution: Vest type jacket placard provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 March 2004
Resolved
Make Fireboy extinguishing system automatically shut off ventilations and engines. 46CFR181.410(b)(11). Complete prior to the carriage of passengers. LEGACY COMPONENT DESC: Operating Controls
Due 29 April 2004
Resolved 4 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 March 2004
Resolved
Provide tourniquet for first aid kit. 46CFR184.710.
Due 29 April 2004
Resolved 4 May 2004
Lifesaving › Lifejacket/PFD (General)
Issued 29 March 2004
Resolved
Post life jacket donning placard. 46CFR185.516. Complete prior to carrying passengers.
Due 29 March 2004
Resolved 4 May 2004
Operations/Management › Vessel Safety Management
Issued 29 March 2004
Resolved
Provide emergency check off list for area in which vessel operates. 46CFR185.510. Complete prior to carring passengers. LEGACY COMPONENT DESC: Emergency Preparedness
Due 29 March 2004
Resolved 4 May 2004
Engineering › Bilge Water Management System
Issued 29 March 2004
Resolved
Provide 5gpm hand bilge pump. 46CFR182.520. Compete prior to carrying passengers. LEGACY COMPONENT DESC: Pump
Due 29 March 2004
Resolved 4 May 2004
Construction/Loadline › Penetrations
Issued 29 March 2004
Resolved
Make hole under operating station that leads into the engine space vapor tight. Complete prior to carrying passengers.
Due 29 March 2004
Resolved 4 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 29 March 2004
Resolved
Provide one portable B-II fire extinguisher with approved bracket for engine space. NFPA 10. Complete prior to carrying passengers.
Due 29 March 2004
Resolved 4 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 29 March 2004
Resolved
Provide approved bracket for other two portable fire extinguishers. NFPA 10. Complete prior to carrying passengers. LEGACY COMPONENT DESC: Mounting Bracket
Due 29 March 2004
Resolved 4 May 2004
Lifesaving › Lifebuoys
Issued 29 March 2004
Resolved
Make ring buoy readily available. 46CFR180.70(b)(2). Ring buoy was fastened to the bracket and not available to be rapidly cast loose. LEGACY COMPONENT DESC: Stowage
Due 29 April 2004
Resolved 4 May 2004
Lifesaving › Lifebuoys
Issued 29 March 2004
Resolved
Provide lanyard of at least 3 feet in length for the floating waterlight with clip. 46CFR180.70(d). Complete prior to carrying passengers. LEGACY COMPONENT DESC: Self-igniting Lights
Due 29 March 2004
Resolved 4 May 2004
Lifesaving › Lifebuoys
Issued 29 March 2004
Resolved
Renew lifeline. 46CFR180.70(c). Complete prior to carrying passengers. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 29 March 2004
Resolved 4 May 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 May 2003
Resolved
Provide lifeline and float light for Ring Buoy. 46 CFR 180.70 Complete prior to the carriage of passengers.
Condition: Unknown
Due 3 June 2003
Resolved 9 June 2003
Fire Fighting › Miscellaneous Items
Issued 3 May 2003
Resolved
Wire fume detector so alarm sounds when detector is activated/functions. 46 CFR 182.480 Complete prior to the carriage of passengers. LEGACY COMPONENT DESC: Fume Detector
Condition: Improper Installation
Due 3 June 2003
Resolved 9 June 2003
Fire Fighting › Ventilation Systems
Issued 3 May 2003
Resolved
Provide vent closures for all engine room vents 46 CFR 182.460 To be completed prior to the carriage of passengers LEGACY COMPONENT DESC: Vent Closures
Condition: Unknown
Due 3 June 2003
Resolved 9 June 2003
Documentation › Markings/Placards
Issued 3 May 2003
Resolved
Provide name on vessel IAW 46 CFR 67.123 & 185 Complete prior to vessel operations. LEGACY COMPONENT DESC: Vessel Name/Hailing port
Condition: Unknown
Due 3 June 2003
Resolved 9 June 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 May 2003
Resolved
Provide First Aid Kit for vessel IAW 46 CFR 184.710 LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Due 3 June 2003
Resolved 9 June 2003
Engineering › Gasoline Engine (propulsion)
Issued 29 March 2003
Resolved
Install fuel filter drip-pans with flame screens (30 x 30 mesh) under the fuel filters. Complete prior to Certification. 46 CFR 182.455 LEGACY COMPONENT DESC: Drip Pans
Condition: Unknown
Due 29 April 2003
Resolved 3 May 2003
Construction/Loadline › Hull
Issued 29 March 2003
Resolved
Repair one crack on the transverse deck frame-port side. 46 CFR 176.700 LEGACY COMPONENT DESC: Weld
Condition: Improper/Lack of Maintenance
Due 29 April 2003
Resolved 3 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 29 March 2003
Resolved
Label forward emergency exit. 46 CFR 185.606 LEGACY COMPONENT DESC: Emergency Exit Placard
Condition: Unknown
Due 29 April 2003
Resolved 3 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 March 2003
Resolved
Provide new fixed fire fighting system with a capacity of at least 383 cubic feet. 46 CFR 181.420 LEGACY COMPONENT DESC: Halon Safe Gas
Condition: Improper Installation
Due 29 April 2003
Resolved 3 May 2003
Navigation › Collision/Grounding Avoidance
Issued 29 March 2003
Resolved
Provide navigation light for vessel that meet COLREGS for vessels more than 12 meters. LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Due 29 April 2003
Resolved 3 May 2003
Fire Fighting › Miscellaneous Items
Issued 29 March 2003
Resolved
Move and lower fume detector-installed in forward part of the engine room/compartment near the fuel tank. 46 CFR 182.480 LEGACY COMPONENT DESC: Fume Detector
Condition: Improper Installation
Due 29 April 2003
Resolved 3 May 2003
Engineering › Fuel Oil Service System › Hose
Issued 29 March 2003
Resolved
Install fire sleeves over current REDLINE fuel hoses (from fuel pump to carbs) on all engines. 46 CFR 182.720
Condition: Improper Installation
Due 29 April 2003
Resolved 3 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 29 March 2003
Resolved
Provide one B-I and two B-II fire extinguishers for the vessel. The B-I should be placed at the operation station. One B-II to be placed near the engine room. And the other B-II someplace in the accommodation space. 46 CFR 181.500 (table).
Condition: Unknown
Due 29 April 2003
Resolved 3 May 2003
Fire Fighting
Issued 14 April 2000
Resolved
Provide copy of 2000 service record on Halon and prove engine shutdown works.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 14 April 2000
Resolved
Provide vapor detector operation placard at control station. Permanently mount alarm unit.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Construction/Loadline
Issued 14 April 2000
Resolved
Replace wasted plywood boards in storage space.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 14 April 2000
Resolved
Provide cut outs in deck over portside fuel cutoff valves.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Lifesaving
Issued 14 April 2000
Resolved
Randomly test at least 50% of the marine employees each year. No ramdom drug testing was done during 1999.
Condition: Unknown
Due 14 April 2000
Resolved 9 May 2000
Construction/Loadline
Issued 14 April 2000
Resolved
Provide a louder bilge high level alarm and permanently mount alarm unit.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Lifesaving
Issued 14 April 2000
Resolved
Provide lifejacket donning placard.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 14 April 2000
Resolved
Provide power ventilation warning sign at operating switch. "OPERATE_x001C_ BLOWER FOR X MINUTES PRIOR TO STARTING"
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 10 April 2000
Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVE PROPER OPERATION OF PORT MAIN ENGINE.
Condition: Unknown
Due 29 April 2000
Resolved 29 April 2000
Navigation
Issued 10 April 2000
Resolved
PRIOR TO OPERATING WITH PASSENGERS MORE THAN 1000 YARDS FROM YOUR DOCK, PROVE / DEMONSTRATE PROPER OPERATION OF VESSEL'S VHF RADIO.
Condition: Unknown
Due 29 April 2000
Resolved 29 April 2000
Documentation
Issued 14 May 1999
Resolved
Provide documentation on membership in drug testing program.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Provide orange smoke distress devices.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Provide splint in first aid kit.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Provide retro-reflective tape on life-ring.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Provide water light for life ring(no night runs until light is onboard).
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999
Resolved
Provide chains at entry way.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Engineering
Issued 20 May 1998
Resolved
Repair water leak at exhaust manifold on center engine.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Electrical
Issued 20 May 1998
Resolved
The vessel is not to be operated after dark until the fixed lighting in passenger seating area is repaired.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Electrical
Issued 20 May 1998
Resolved
Properly install wiring for loud hailer.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Engineering
Issued 20 May 1998
Resolved
Repair/replace crushed fuel vent on starboard side.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Documentation
Issued 16 May 1996
Resolved
COMPLETE CHEMICAL TESTING PROGRAM AUDIT FORM (B) AND ENSURE COMPLIANCE WITH46 CFR PART 16. RETURN FORM (B) TO MSD BATON ROUGE.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Documentation
Issued 12 May 1994
Resolved
PREPARE AND POST AN EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46CFR 185.25-1 & 46CFR 185.25-5.
Condition: Unknown
Due 12 June 1994
Resolved 18 June 1994
Lifesaving
Issued 2 September 1992
Resolved
MAKE AVAILABLE FOR UNDERWAY OBSERVANCE OF OPERATIONS AREA BY MARINE INSPECTOR, TO DETERIMINE OPERATOR VISIBILITY AND HANDLING CHARACTERISTICS.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Documentation
Issued 2 September 1992
Resolved
CONDUCT A SIMPLIFIED STABILITY TEST.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Construction/Loadline
Issued 2 September 1992
Resolved
PROVIDE A GAS AND WATERTIGHT FORWARD ENGINE SPACE BULKHEAD.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Accommodation/Occupational Safety
Issued 2 September 1992
Resolved
PROVIDE RAILING AROUND COMPLETE PASSENGER AREA IN ACCORDANCE WITH 46CFR177.35.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992