Records from 1991 to 2002. Most recent: inspection, 5 March 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
5 March 2002
MARPOL Annex I Examination · Passenger/Freight Vessel Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1489393
27 February 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 426025
22 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415001
8 August 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 406515
24 March 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 401893
16 January 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 399292
10 January 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 386498
18 September 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 382999
17 July 1992
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 352311
17 July 1992
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 352564
5 November 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 346854
Personnel › Certificates/Documents/Licenses
Issued 5 March 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2002
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment
Issued 5 March 2002
Resolved
Prove proper operation of Oily Water Separator to the satisfaction of Class Surveyor LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 March 2002
Resolution: Class attended and inspected the ship''s oily water separator system and found it in compliance with MARPOL.
Construction/Loadline › Markings › Load Line Mark
Issued 5 March 2002
No resolution recorded
Loadline and draft markings need to be repainted in a color contrasting the hull color
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Electrical › Electric Generation Source (emergency)
Issued 5 March 2002
Resolved
Emergency generator needs auto-start mechanism LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2002
Resolution: Class attended and inspected the emergency auto-starting system that was found previoulsy inoperable. The system was tested and found satisfactory by Class.
Communications › Internal Communications System
Issued 5 March 2002
Resolved
Ringer on phone between the bridge and engineering spaces is inoperable
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2002
Resolved 10 March 2002
Resolution: Attended and tested phone system on bridge and steering room repaired by Harris Electric on 03/03/02. Found system fully operational.
Deck/Cargo
Issued 22 April 1998
Resolved
PRIOR TO USING IN U.S. WATERS, INSTALL CONTAINMENT AROUND THE STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Navigation
Issued 22 April 1998
Resolved
RESOLVE DISCREPANCY OF TWO (2) DEGREES BETWEEN AFTER STEERING INDICATOR ANDBRIDGE INDICATOR.
Condition: Unknown
Due 22 May 1998
Resolved 4 May 1998
Deck/Cargo
Issued 22 April 1998
Resolved
PROVIDE CARGO SECURING MANUAL.
Condition: Unknown
Due 22 May 1998
Resolved 29 April 1998
Documentation
Issued 22 April 1998
Resolved
PROVIDE WRITTEN INSTRUCTIONS REGARDING VESSEL FAMILIRIZATION AS REQUIRED BYSTCW (AMENDED) I/14.
Condition: Unknown
Due 27 February 1999
Resolved 2 March 1999
Fire Fighting
Issued 22 April 1998
Resolved
EITHER REPLACE FIREMEN'S OUTFITS OR SCBA SO THAT THEY ARE COMPATIBLE WITH EACH OTHER.
Condition: Unknown
Due 27 February 1999
Resolved 2 March 1999
Navigation
Issued 16 January 1997
Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES PRIOR TO DEPARTURE FROM THE PORT OF DUTCH HARBOR, AK.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Documentation
Issued 16 January 1997
Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREWMEMBERS PRIOR TO REENTRY INTO U.S.WATERS.
Condition: Unknown
Due 24 March 1997
Resolved 24 March 1997
Documentation
Issued 16 January 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Fire Fighting
Issued 18 September 1995
Resolved
PROVIDE REPLACEMENT FIRE FIGHTING NOZZEL FOR FORWARD WHEELHOUSE FIRE STATION IN ACCORDANCE WITH SOLAS 74 II-2/21.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 18 September 1995
Resolved
REMOVE SHIP'S STORES FROM HOSPITAL SPACE IN ACCORDANCE WITH ILO 147, II.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Documentation
Issued 18 September 1995
Resolved
PROVIDE COMPLETE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.720.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996