← All vessels
NEHU
NEHU is a 1991 towing vessel. The Coast Guard has recorded 61 inspections since 1991, most recently in February 2026, along with 67 deficiencies.
Records from 1991 to 2026. Most recent: inspection, 18 February 2026.
- Built
- 1991
- Last inspected
- 18 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 67 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
977466
9030773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDN3392
365287
Flag
UNITED STATES
368271250
Maury page id
psix-365287
Inspections, by type
…with no type recorded13
Years with a record
34 calendar years (1991–2026)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)120.2 ft × 30.0 ft × 12.0 ft
Registered tonnagegross 84 / net 59
ITC dimensions (L × B × D)120.2 ft × 30.0 ft × 12.0 ft
ITC tonnagegross 337 / net 101
BuilderHOUMA FABRICATORS · HOUMA, LA, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 16 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it337 - Convention (Subpart B), Gross Ton
84 - Regulatory (Subpart C or D), Gross Ton
101 - Convention (Subpart B), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
84 - Regulatory (Subpart C or D), Gross Ton
101 - Convention (Subpart B), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN3392MMSI 368271250 · active · compulsorily equipped · granted 4 August 2022, expires 4 August 2032
WDH2136MMSI 367594740 · expired · compulsorily equipped · granted 8 November 2013, cancelled 13 January 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDF7572MMSI 367485860 · cancelled · compulsorily equipped · granted 13 April 2011, cancelled 14 April 2014 · licensed under a name not among this hull’s recorded names (not shown)
WDD9627MMSI 367314070 · expired · voluntarily equipped · granted 19 September 2007, cancelled 25 November 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDD9572MMSI 367313260 · expired · voluntarily equipped · granted 13 September 2007, cancelled 18 November 2017 · licensed under a name not among this hull’s recorded names (not shown)
WCX2740MMSI 366757840 · cancelled · compulsorily equipped · granted 29 October 1998, cancelled 16 January 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
18 February 2026
Deficiency Check · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8312458
8 April 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8108495
12 February 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7866316
10 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847946
19 January 2023
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7624125
1 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7548609
28 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7066845
22 May 2019
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6690504
21 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6629861
8 December 2017
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6320560
19 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5946153
6 July 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5932900
9 September 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5718733
5 November 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5018470
27 August 2014
Hull Examination · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4966081
3 April 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4845611
4 October 2013
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4728510
5 June 2013
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 4612662
13 September 2012
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4438924
30 August 2011
Deficiency Check · Annual Inspection · Drydock Exam · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4131126
7 September 2010
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3844542
10 December 2009
DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3644076
18 August 2009
Internal Structural Exam · Examination of Repairs · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3568971
16 December 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3381141
26 September 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3066393
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806558
29 September 2006
Hull Examination · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2789698
15 September 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501191
6 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2198376
16 August 2004
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2167435
16 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1929617
17 July 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1849339
11 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1717478
5 October 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462271
19 September 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446986
14 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101318
22 September 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450344
7 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 672183
5 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 47447
24 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454602
25 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131873
3 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766635
29 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793097
26 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101151
26 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 198558
2 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783524
17 September 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116573
30 January 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102000
25 September 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398544
8 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187971
13 September 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428388
27 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1178241
28 December 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414227
10 September 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451887
1 October 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431165
7 May 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260291
1 April 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957847
8 January 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 950212
24 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268655
5 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 943387
19 September 1991
Initial Certification · Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252352
Deficiency record · 67
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 February 2026
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. The fuel transfer pump is energized by opening the electrical cabinet and manually pushing the motor’s electrical contact button. Repair to operate as designed by the manufacturer to the satisfaction of the attending marine Inspector.
46 CFR 111.01-1(a)(2)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 February 2026
Resolved
Table 1 to § 95.50-10(b) indicates the minimum required number and type of extinguisher for each space listed. Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the requirements of the table. Internal combustion or gas turbine propelling machinery spaces 40-B; 1 for each 1,000-brake horsepower; not less than 2 but not more than 6. Vessel is 4,000 brake horsepower and only has two 40-B hand portable fire extinguishers. Provide two additional 40-B hand portable fire extinguishers to comply with the regulation. To the satisfaction of the attending Marine Inspector.
46 CFR 95.50-10(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 February 2026
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. The five (5) Pro Nautic battery chargers are not installed in accordance with the manufacturer’s requirements due to missing overcurrent, creating an electrical hazard. Install the correct amperage overcurrent protection on the output side of the battery charger in as per the manufacturer to the satisfaction of the attending Marine Inspector.
46 CFR 111.01-1(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 February 2026
Resolved
The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page: A description of each transfer system on the vessel including: A line diagram of the vessel's transfer piping, including the location of each valve, pump, control device, vent, and overflow. Missing the fuel manifold transfer system line diagram. Provide the fuel transfer line diagram to the satisfaction of the attending Marine Inspector.
33 CFR 155.750(a)(2)(i)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 February 2026
Resolved
Gears, couplings, flywheels, and all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. The starboard steering gear pump coupling protective cover is missing. Install protective cover to the satisfaction of the attending Marine Inspector.
46 CFR 58.01-20
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 February 2026
Resolved
Each forced draft fan induced draft fan, blower of an inert gas system, fuel oil transfer pump, fuel oil unit, fuel oil service pump, and any other fuel oil pumps must have a stop control that is outside of the space containing the pump or fan. Attending Marine Inspector could not witness the fuel pump emergency stop due to a faulty pump controller. Repair fuel transfer pump controller and test the emergency stop in the presence of the attending Marine Inspector.
46 CFR 111.103-9(a)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 8 April 2025
Resolved
(a) In General.-A vessel engaged in commercial service that does not carry passengers, shall maintain a video surveillance system.
(c) Placement of Video and Audio Surveillance Equipment.-
(1) In general.-The owner of a vessel to which this section applies shall install video and audio surveillance equipment aboard the vessel not later than 2 years after enactment of the [name withheld] Coast Guard Authorization Act of 2022, or during the next scheduled drydock, whichever is later.
(2) Locations.-Video and audio surveillance equipment shall be placed in passageways on to which doors from staterooms open. Such equipment shall be placed in a manner ensuring the visibility of every door in each such passageway. While reviewing the vessel’s SASH Policy, company removed mattresses to allow for only 09 crew on the vessel. The COI has total persons allowed at 24. Company must install video and audio surveillance equipment in passageways on to which door from staterooms open.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 January 2024
Resolved
a) Fire detection, manual alarm, and supervised patrol systems are not required except in special cases; but if installed, the systems must meet the applicable requirements of 46 CFR, part 76 of subchapter H (Passenger Vessels) of this chapter.
(a) Detectors must be responsive to heat, smoke, or other products of combustion, flame, or any combination of these factors. Smoke detector located in the galley does not work.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2024
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. In addition a mud box or basket strainer shall be fitted in an accessible position between the bilge suction manifold and the pump. There are no strainers for the bilge suction piping.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 10 January 2024
Resolved
Clear instructions must be provided on the vessel that detail the actions each person on board should follow in the event of an emergency. Crew was unable to initially operate bilge suction during test. Need clear instructions for operation and valve alignment.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 February 2023
Resolved
Each vessel must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel outfitted with six hand red hand and six hand orange smoke flares. Vessel restricted from carrying persons other than crew until 12 rocket parachute flares approved under approval series 160.136 are provided. 46 CFR 199.60(c)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 February 2023
Resolved
Each life raft or group of life rafts must be arranged for float-free launching. The arrangement must ensure that the lifer aft or life rafts, when released and inflated, are not dragged under by the sinking vessel. Port side life raft mounted on the deck under the ladder leading to and from the main deck and 01 deck and the 01 deck overhanging superstructure. Relocate life raft to ensure the arrangement is float-free from any surrounding obstructions. 46 CFR 199.130(c)(7)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
All fire hose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 psi. Fire main pressure was recorded to be 80 psi. Provide a test pressure of at least 100 psi to the satisfaction of the the attending MI conduct the fire hose inspection. 46 CFR 91.25-20(a)(4)
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 February 2019
Resolved
Vessel does not have updated notice of intent (NOI), vessel must submit and update NOI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2019
Resolved
Vessel has inacurate rudder angle indicator. Ensure rudder angle indicator operates properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 February 2019
Resolved
Lifefloat weak link was not the appropriate size vessel had 11-20 persons instead of 21 or more. Replace weak link with correct capacity.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 February 2019
Resolved
EPIRB battery and hydrostatic release were both expired. Both need to be replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 February 2019
Resolved
Vessel has multiple navigation lights in-operable. Replace any in-Op lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 February 2019
Resolved
Multiple engine fuel filters are missing plugs. Replace all missing plugs in all fuel strainers.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 December 2017
Resolved
Alcohol test strips onboard were expired. Obtain up to date test strips.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 8 December 2017
Resolved
Tachometer doesn't work when going ahead on port engine.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 December 2017
Resolved
Vessel had not conducted an abandon ship drill since 06/22/17. Provide proof of proper logging of conducted drills.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 December 2017
Resolved
Vessel only had 10 good lifejackets onboard. Restricted to 10 persons onboard until vsl obtains more lifejackets.
Engineering › Fuel Oil Service System › Filter
Issued 8 December 2017
Resolved
Fuel filters missing flame shield. Provide evidence of installed flame sheilds on filters.
Engineering › Steering Gear System › Rudder
Issued 8 December 2017
Resolved
Shaft packing leaking in excess. Tighten shaft packing to prevent leaking.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 8 December 2017
Resolved
Show proper operation of ground indicator on switchboard.
Construction/Loadline › Structures › Door
Issued 8 December 2017
Resolved
Doors on back deck to engine room not weathertight. Tighten doors and proove weathertight.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 July 2016
Resolved
Crew could not prove to MI that they could retrieve somebody from the water, lack of experience and roles and responsibilities.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 July 2016
Resolved
Lagging missing on exhaust.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 July 2016
Resolved
Batteries in the engine room and passageway were not properly secured in boxes that could prevent them from moving.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 July 2016
Resolved
Interlock on switchboard would not work properly because door of switchboard was not properly securied.
Engineering › Pressure Vessel › Pressure Gauge
Issued 19 July 2016
Resolved
Pressure gauges on air recievers were cracked and unreadable.
Communications › Radio Communications › EPIRB
Issued 19 July 2016
Resolved
Provide registration sticker for EPIRB
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 19 July 2016
Resolved
Vessel was noty keeping any logs as required. To be corrected at next annual inspection.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 July 2016
Resolved
Epirb monthly checks not being logged. To be cleared at next annual inspection
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 July 2016
Resolved
Port, Stern and anchor lights not working.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 July 2016
Resolved
Alcohol test strips were expired by 2 years.
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 5 November 2014
Resolved
SHAFT SPEED INDICATORS INOPERABLE AT BRIDGE CONTROLS. PROVE PROPER OPERATION OF SHAFT TACH. CITE: 46 CFR 113.37-5. DUE: 05DEC2014.
Engineering › Pressure Vessel › Shell Plate
Issued 13 September 2012
Resolved
Renew aft air receiver due to wastage behind data plate.
Communications › Internal Communications System › Sound-powered Telephone
Issued 13 September 2012
Resolved
Repair sound power phone ringer from bridge to engine room.
Electrical › Electric Supply System (service) › Cable
Issued 30 August 2011
Resolved
Wire between PORT Engine Room Blower and its control box needs to be replaced with approved marine wiring. Wire sparked when blower was place in on position.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 30 August 2011
Resolved
Battery backup for nav equipment and Bridge Emergency equipment not working properly. Show proper operation of emergency power for navigation/General Alarm/PA.
Engineering › Steering Gear System › Ram
Issued 30 August 2011
Resolved
Steering system only reaching 5 degree hard port and 20 degrees hard STBD. Further investigation revealed improper Ram placed in system. Replace ram and demonstrate proper operation of steering gear.
Engineering › Fuel Oil Service System › Hose
Issued 10 December 2009
Resolved
Renew all flexible hases as marked on both main engines, both generators, and the bow thruster engine (approx 12 hoses).
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 December 2009
Resolved
Provide and install shaft guard on the dirty oil pump.
Communications › Alarms/Indicators › General Alarm
Issued 10 December 2009
Resolved
Provide and install new general alarm light in the Engine Room and provide warning placard.
Construction/Loadline › Structures › Door
Issued 26 September 2007
Resolved
Port Engine room escape vestibule WTD did not seal properly
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 September 2007
Resolved
Vessel had new crew onboard and new operator, had not logged any drills
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 26 September 2007
Resolved
Rudder angle indicator inoperable.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 September 2007
Resolved
Stbd side escape vestibule lighting broke
Engineering › Fuel Oil Service System › Hose
Issued 20 August 2004
Resolved
Renew 2 fuel lines flexible hoses on bow thruster.
Engineering › Fuel Oil Service System › Hose
Issued 20 August 2004
Resolved
Renew 3 fuel oil flexible hoses on starboard main engine and 2 hoses on port main engine.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 20 August 2004
Resolved
Make air receivers ready for visual inspection of accesses to internals of receivers prior to sailing, take thickness measurements on collars and hydro tanks as required by 46 CFR 61.10.
Stability › Watertight Integrity
Issued 16 October 2003
Resolved
Make repairs to port side engine room emergency escape watertight door. LEGACY COMPONENT DESC: Emergency escape watertight door
Engineering › Thrusters
Issued 16 October 2003
Resolved
Renew two marked fuel hoses and repair fuel leak on bow thruster engine. LEGACY COMPONENT DESC: Hose
Engineering › Fuel Oil Service System › Filter
Issued 16 October 2003
Resolved
Provide flame shield on aft generator fuel filter.
Fire Fighting › Miscellaneous Items
Issued 16 October 2003
Resolved
Provide placards for engine room fire station. LEGACY COMPONENT DESC: Placards
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 December 2002
Resolved
PROVIDE CURRENT DEVATION CARD.
Lifesaving › Buoyant Apparatus
Issued 11 December 2002
Resolved
PROVIDE SPACERS BETWEEN LIFE FLOATS. LEGACY COMPONENT DESC: SPACERS
Engineering › Fuel Oil Service System › Hose
Issued 11 December 2002
Resolved
RENEW FORWARD GENERATOR FUEL OIL FLEXIBLE HOSE.
Construction/Loadline › Structures › Door
Issued 11 December 2002
Resolved
ADJUST DOGS ON ALL WATERTIGHT DOORS.
Accommodation/Occupational Safety
Issued 24 September 1998
Resolved
PROVIDE SEWAGE HOLDING TANK 3/4 FULL LEVEL INDICATOR.
Electrical
Issued 24 September 1998
Resolved
PROVIDE EMERGENCY POWER FOR SSB RADIO.
Engineering
Issued 24 September 1998
Resolved
MAKE OPERABLE, REMOTE PROPULSION ENGINE STOPS AT PILOT HOUSE CONTROL.
Accommodation/Occupational Safety
Issued 24 December 1991
Resolved
PROVIDE APPROVAL FOR INSTALLED TOAST MASTER RANGE AS REQUIRED BY 46 CFR 111.77-3.
Electrical
Issued 24 December 1991
Resolved
PROVIDE APPROVED PLANS OF DECK WIRING AS REQUIRED BY 46 CFR 110.25-1.
Engineering
Issued 24 December 1991
Resolved
PROVIDE APPROVAL OF BOTH PRESSURE VESSELS MADE BY MANCHESTER TANK AS REQUIRED BY 46 CFR 54.01-5(D) AND CORROSION ALLOWANCE AS REQUIRED BY 46 CFR54.01-35.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.